| 1 | NOTE (Applicable for all parts/items):-The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | SCHEDULE \"A\" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced schedule is given in tender documents. |
| 3 | SCHEDULE \"A\" PART-II (SITE CLEARANCE AND DEVELOPMENT AND EARTHWORK) Details of prepriced Schedule is given in tender documents |
| 4 | SCHEDULE \"A\" PART-III (ROADS/PCC PAVEMENT INTERNAL ) Details of prepriced Schedule is given in tender documents |
| 5 | SCHEDULE \"A\" PART-IV (EXTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents |
| 6 | SCHEDULE \"A\" PART-V (EXTERNAL ELECTRIC SUPPLY ) Details of prepriced Schedule is given in tender documents |
| 7 | SCHEDULE \"A\" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents |
| 8 | SCHEDULE \"A\" PART-VII (AREA DRAINAGE ) Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \"A\" PART-VIII (RETAINING WALL) Details of prepriced Schedule is given in tender documents |
| 10 | SCHEDULE \"A\" PART-IX (FENCING COMPOUND WALL/STEEL GATE) Details of prepriced Schedule is given in tender documents |
| 11 | SCHEDULE \"A\" PART-X (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents |
| 12 | SCHEDULE \"A\" PART-XI (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents |
| 13 | SCHEDULE \"A\" PART -XII (MISCELLANEOUS ITEMS)Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.\" 5 \" signifies this fact only. |
| 14 | Supplying, Installing, testing and commissioning of Monoblock pump set having capacity 5 HP, haed 18m, discharge 13.5LPS, suitable for operation on 3 Phase, 415 Volts ± 10%, 50 Hz, AC Supply complete all as per manufacturer’s instructions, as specified and as directed. Note: The rate quoted shall be deemed to be inclusive of necessary civil work viz. PCC foundation and connected works for installation of Pump Set and its accessories as required at site. |
| 15 | Supplying, installing, testing and commissioning of Monoblock pump DOL startersuitable for 7.5HP motor complete all as specified and as directed. |
| 16 | M&L for PVC insulated & unsheathedround copper cable for monoblock pump- motor 1100V, 4.0 Sqmm nominal area 3 core, incl 20mm dia pvc heavy duty conduit pipe and connections with accessories etc, complete all as specified and as directed. |
| 17 | S & F Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed. |
| 18 | S & F 4 M flush type with starter & 16 Amp plug top with indicator suitable for AC complete all as specified. |
| 19 | S & F Wall mounted Fan, 400mm Sweep, Metal Body, Heavy duty, 230 Volts, AC, 50 Hz, Wall Mounting Type including speed control set and all accessories complete all as specified. |
| 20 | Supply, installation, testing and commissioning cubical type CPRI approved LT feeder pillar panel board of size800mmx500x400mm box type, outdoor type, dust, vermin, weather proof IP65, of suitable size, slopy canopy, factory made fully compartmentalised made out of 3.15 mm thick CRCA sheet steel duly painting with two coats of epoxy powder coated paint over a coat of primer after undergoing a rigerous metal treatment process involving alkaline, descaling in dilute sulphuric acid degreasing, phosphatising etc for load and non load bearing, back door openable with necessary locking arrangement made of 50 x 6mm MS angle iron frame work, legs grouted in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate,totally enclosed with copper bus bar of 200 Amp rated suitable for 4 wire ,415 v ,50Hz ,3 ph ,duly colour code by providing PVC sleeeves and carry out internal wiring of accesssories of suitable size pvc copper conductor and connecting the bus bar to MCCB /MCB through suitable copper conductor cable with thimble /lugs etc, and providing cable gland at cable entry into panel with following: INCOMING : (a) MCCB FP 125 Amp ,415v,50 HZ,25 KA -01 No. OUTGOING: (b) MCCB FP 63 Amp ,415v,50 HZ,16 KA -03 Nos.(c) MCB SPN 40 Amp, 240 Volts, 50Hz AC supply -02 Nos. (d) Digital voltmeter 0-500 volt with selector switch -01 No (e) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (f) Indicator lamp (RYB) LED type - 01 set(g) Street Light Timer- 240 volts, single phase, 20 Amps rating with contactor-01 No. |
| 21 | M&L for pole box made of MS sheet 3 mm thick of size 15cmx10cmx5cm with two nos aluminium terminal bus bar incl 01 no MCB SP 6 amp incl locking arrangement, fix on pole by suitable size of clamp with including two coats of aluminium paint over a caot of primer complete incl electric connection complete all as specified and as directed. |
| 22 | Supply and fixing Soap Dish, Stainless steel of approximate size 160 x 160 x 90 mm with brass screwscomplete all as specified and as directed. |
| 23 | S & F 100mm size Stainless Steel grating for Floor Traps complete all as specified and as directed. |