| 1 | Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each including iron mongrie complete all as specified and directed. |
| 2 | Taking down chowkhat with shutter (without taking off shutter from the frame) and arean.exc 1.50 sqm eachincluding iron mongrie complete all as specified and directed. |
| 3 | S&F anodized 50 micron powder coated aluminium door shutters,with frame of section 100x44x1.60 to1.8 mm thick, aluminium sections for shutter anodised aluminum powder coated shutter, Glazing shall be of 4.8 mm thick sheet glass tinted, fixed with rubber gasket and aluminum glazing clips, section of aluminum shutter of following sizes complete all as specified and directed.(i) Styles 85 x 44.45 x 3 mm thick (ii) Top rail 95.25 x 44.45 x 1.7 mm thick(iii) Middle/lock rail 83.50 x 44.45 x 1.7 mm thick (iv) Bottom rail 114.3 x 44.45 x 2.82 mm thick (v) Glazing clip 0.70 mm thick (vi) Handle: Aluminum handle 100mm girth and as per sample(vii) Tower bolt: 9.90 mm dia sheet and , 200 mm long(viii) Mortic lock: 100 mm size 4 lever. |
| 4 | S&F for powder coated alumium glazed window shutter sliding type using 1.80 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rails 100x44mm.including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodisedaluminium fittings complete and including glazingby using 5mm thick plain sheet glass and stainless steel wire mess of dia 0.36mm and aperture 1.4mm, complete all as specified and as directed. ((Note-glazed shutters glass thickness not less than 5.00 mm and wiremess shutter with SS wiremesh as approved by GE is also included. No extra payment will be made separately) |
| 5 | S&F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodize coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws , including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge |
| 6 | S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides partition fixed with tinted sheet glass Glazing shall be of 4.8 mm thick sheet and 18mm thick pre-laminated partical board both side finished in whitealongwith required EPDM rubber/ neoprene gasket.complete all as specified and directed. |
| 7 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick in cement mortar 1:6 onfair face of brick work of walls, finished even & smooth without using extra cement,complete all as specified and directed. |
| 9 | M&L for rendering 15 mm thick in cement mortar 1:4 onfair face of brick work of walls, finished even & smooth without using extra cement,complete all as specified and directed. |
| 10 | M&L for Preparing of new plastered surface of wall and applying two coats of Oil emulsion distemper (OBD) of approved shade / tint over a coat of primer over a coat of Birla care putty not less than 2.0 mm thick putty complete, all as specified and directed. |
| 11 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of Birla care putty not less than 2.0 mm thickcomplete all as specified and directed. (Note- Primer and emmulsion to be carried out through air less spray machine (Mechanical means) |
| 12 | M&L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed. |
| 13 | M & L brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:6 complete all as specified and as directed. |
| 14 | M&L RCC (1:2:4) type B-1using 20 mm graded Crushed stone aggregate on beams, cantilevers, lintel over 1.5 m Span complete all as specified anddirected. |
| 15 | M&L for TMT bars 10 mm dia and over for reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, and binding with and incl MS wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-415 or Fe-500 complete all as specified and directed. |
| 16 | M&L TMT bars of 6 to 8mm dia as in stirrups/spacers cut to lenth, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.complete all as specified and directed. |
| 17 | M&L for 18-20 mm thick black granite (of any type) work (table rubbed & polished) in steps, jambs, pillars, window-cills, cooking platforms & like, over 20mm thick screed bed in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite, complete all as specified and directed. |
| 18 | M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking plateform incl making hole for gas pipe and other similar situation complete all as specified and directed. |
| 19 | M&L forProviding precast cement concrete 1:3:6 C1type( 20 mm graded crushed stone aaggregate )as in copings. kneelers, apex stones complete all as specified and directed. |
| 20 | Excavating in pol holes (or similar holes) each n exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm, complete all as specified and directed. |
| 21 | M&L PCC (1:4:8) type D-2 using 40 mm crushed stone aggregate as in foundation filling, complete all as specified and directed. |
| 22 | S&F steel workas for post including guset plate of suitable size welded at both ends for anchoring and for fixing of purlin and rafter including special shaped washers etc complete all as specified and directed. |
| 23 | S&Frolled section as in main and cross beams, hip and jack rafters, purlins where connnected to common rafters and running rails and guides for sliding door etc conf to Fe 410- W complete all as specified and directed. |
| 24 | S&F for Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 25 | S&F for Pre-paintedgalvalume aluminum zinc coating GI basedPlainsteelsheet 0.50mmthick( Base metal thickness)ofany colourhavingtensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 26 | M&L for preparation of newly steel surface and applying two coats of synthetic enamel paint over a coat on red oxide on steel surface of any description over 10cm grith or width, not otherwise described, complete all as specified and directed. |
| 27 | Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/ Loose soil complete all as specified and directed. |
| 28 | M&L for hard core broken stone or boulders of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, water and rammed to a true surface complete all as specified and directed. |
| 29 | M&L 100 mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in sub base of floor complete all as specified and as directed. |
| 30 | S&F 60 mm thick, machine pressed rubber moulded, glossy coloured, precast conctete interlocking paver block any shape and size of M-35 grade of approved shade with grey cement and pigment laidcomplete all as specified and directed. |
| 31 | M&L for Sand cushion and filled with fine sand Sandfillingunderfloorsorin foundations including watering and consolidation complete all as specified and directed. |
| 32 | Removing of excavated materials to a distance not exceeding 50 M and deposing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 33 | Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed. |
| 34 | M&L 75mm thick cement concrete type C2, 1:3:6 (40mm graded stone aggregate) as in sub-floors, sub-bases, etc.complete all as specified and directed. |
| 35 | Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases incl with modular sunken boxes in walletc and making good to the disturbed surfaces to match the existing complete all as specified and directed. |
| 36 | All as per serial item No 35 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.complete all as specified and directed. |
| 37 | All as per serial item No 35 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.complete all as specified and directed. |
| 38 | All as per Serial Item No 35 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 39 | S&FSwitch Modular 6A single pole, one way, 1 module complete all as specified and as directed |
| 40 | S&FSwitch Modular 16A single pole, one way, 1 module complete all as specified and as directed |
| 41 | S&FSocket, 6A - 2/3 pin combined 2 module complete all as specified and as directed |
| 42 | S&F Modular White cover plate with frame,8 module complete all as specified and as directed |
| 43 | S&F Modular White cover plate with frame,3 module complete all as specified and as directed |
| 44 | Supply and fixing LED tube light fittings 1200 mm,20 Whigher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed. |
| 45 | Supply and fixingceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm sizecomplete all as specified and directed. |
| 46 | Material and labourfor sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified and directed. |
| 47 | M&L in factory made powder coated distribution board 4 way TPN DB Double door with metal double door (IP-43 protectionIK -09) fabricated of CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, Neutral bar, Standard din rail,earth bar and cable ties for cable management, top and bottom removable gland plates after fixing making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed. |
| 48 | Supply and fixof MCB, SP, AC, 240 volt of 06 to 40 Amp capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed. |
| 49 | Supply and fix in replacement of MCB, TPN, AC, 415 volt of 63 Amp capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed. |
| 50 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipemedium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in RCC 1:2:4 type B1 duly reinforced with Tmt Bars of 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed. |
| 51 | Supply and fixing in replacement LEDBldg security light fitting LED 35 watt with SPD, PF not less or equal0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass& IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed. |
| 52 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4.0 core complete all as specified and directed. |
| 53 | Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as specified and directed. |
| 54 | M&L Returningfilling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and directed. |
| 55 | Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cablefor under ground cable complete all as specified & directed.(Note Punned down thick shall be considerd for mesurement and payment) |
| 56 | M&L Old size sub class \"B\" bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified and directed. |