| Sl. No. | Item Description |
| 1 | Taking down chowkats or frameswith shutters(without taking offshutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed. |
| 2 | Description all as per item No. 1 above but area exceeding 1.50 square metre and not exceeding 4 square metre each. |
| 3 | Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc.complete,of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer,including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed. |
| 4 | Mild steel, plain, 1.25 mm thick black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed. |
| 5 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed. |
| 6 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 7 | 18/19 mm thick prelaminated particle board (ISI marked), exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timberframe work for kitchen cabinet stand board etc including 6mm thick teak wood beading all around, incl dismentling of old existing shutter, complete all as specified and as directed. |
| 8 | Providing cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates for, filling asin the pressed steel door frame/hold fastcomplete all as specified and as directed. |
| 9 | Machine cut kota stone slab flooring 20-25 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6,complete all as specified and as directed. |
| 10 | Machine cut kota stone 20-25mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for laying wall tiles, complete all as specified and as directed. |
| 11 | Mortice lock with two lever Mild Steel body (vertical type) 100mm length of latch with 3 set of keys fixed in door shutter with proper in position complete all as specified and directed. |
| 12 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief. |
| 13 | Powder coated (not less than 50 micron) anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete, all as specified and directed. |
| 14 | Powder coated Anodised aluminium sliding shutter of window , andventilator openable/louvers fixed /sliding type shutters without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete, all as specified and directed. |
| 15 | Anodised aluminium grill5 to 6 mm dia of mesh Not exc 7.5cm in either direction (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engr- in Charge. |
| 16 | 5mm thick frosted/tinted sheet glassfixed to aluminium section of doors, windows and fixed frame with suitable EPDM rubber packingand powder coated aluminium beading to frame, complete all as specified and as directed. |
| 17 | 12 mm thick prelaminated particle boards, exteriorr grade, prelaminated both side with decorative choice lamination and other side balancingwhite lamination fixed with screws and 6mm thick wooden beading surrounding cut portion of board complete all as specified and directed. |
| 18 | 18/19 mm thick prelaminated particle boards, exteriorr grade, prelaminated bothside with decorative choice lamination and other side balancingwhite lamination fixed with screws and 6mm thick wooden beading surrounding cut portion of board complete all as specified and directed. |
| 19 | Aluminium (Die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weightbetween 61 to 80 kg complete all as specified and as directed. (ISI Mark) |
| 20 | 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed. |
| 21 | Demolition of cement concrete (unreinforced) in any description and in any position not other wise provided for and removing the debris to a distance not exc 500m from site all as specified and directed. |
| 22 | PCC 1:3:6type C1 using 20 mm graded stone aggregrate as in floor, plinth protection , surface channel ,path and all as directed. |
| 23 | Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples complete, all as specified and directed. |
| 24 | Mild steel cold rolled butt hinges mediumweight 100 mm long fixed to steel /angle iron frame by welding, if required complete, all as specified and directed. |
| 25 | 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark) |
| 26 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, 140mm overall length of cover plate complete all as specified and directed.(ISI Mark) |
| 27 | 25 mm stainless steel curtain rod withdecorative Brackets all as specified and as directed. |
| 28 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 29 | 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified. |
| 30 | S & F in replacement WC (Squattpattern ) including cement concrete bedding , size 580 x 440mm including PVC\"P or s trap front and back inlet and with internal foot rests(excluding flushing cistern ) including flush pipeand connector pices of PVC and removed old CIPipe including demolition of PCC upto 450mm depthcomplete all as specified and directed. |
| 31 | Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia, fixed in repairs, complete all as specified and as directed. |
| 32 | Vitreous China urinals, half stall (back or corner wall type) white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), fixed in repairs, complete all as specified and directed. |
| 33 | 10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed. |
| 34 | Demolition and breaking up drain pipes, 100mminternal dia (Salt glazed ware, AC or Reinforced concrete)set in cement mortar, complete all as specified and as directed. |
| 35 | 110mm bore, PVC (SWR) pipes, single or double socketed, in any length with rubber ring joints, fixed to walls/floor with stack clamps, complete all as specified and as directed. |
| 36 | 110 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all specified and as directed. (ISI Marked) |
| 37 | Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed. |
| 38 | Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed. |
| 39 | 20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls andceiling or laid under floors etccomplete all as specified and as directed. |
| 40 | 15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and ceiling or laid under floors etccomplete all as specified and as directed. |
| 41 | Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repairs, complete all as specified and as directed. |
| 42 | PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 43 | Grating doom 100mm dia of PTMT (Minimum weight 25gms)fixed in repairs, complete all as specified and as directed. |
| 44 | Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs,complete all as specified and as directed. |
| 45 | Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrulefor bore of pipe 15 mm fixing in repair, complete all as specified and as directed. |
| 46 | 600mmx450mm beveled edge mirror 5.5mm thick of selected quality glass, mounted on 6mm thickcommercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 47 | Rotational moulded polyethylene water storage tank , three layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight210 gram) etc),incl dismantling existing water tanks, complete all as specified and as directed. |
| 48 | PVC (SWR) floor trap 75mm size, plain with grating including jointing with solvent cement fixing in repairs, complete all as specified and as directed. |
| 49 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed. |
| 50 | 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4 with WPC, finished even andfair, complete all as specified and as directed. |
| 51 | 10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finishedeven and smooth without using extra cement, complete all as specified and as directed. |
| 52 | 5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface fair and even without using extra cement, complete all as specified and as directed. |
| 53 | Complete removal of existing treatment on walls and applying two coats of oil bound distemperon wallsover a coat of 1 mm thick putty and all as specified & directed. |
| 54 | Complete removal of existing treatment on walls and applying two coats of cement base paint on walls all as specified & directed. |
| 55 | Preparing plastered or unplasterednew surfaces of wall and applying three coats of white wash, complete all as specified and as directed. |
| 56 | Preparation new surfaces plastered or unplastered and applyingthree coats of white wash on ceiling, complete all as specified and as directed. |
| 57 | Preparation of new plastered surfaces of walls and applying two coats of cement based paint white or tinted over a coat of chalk whitening primer coat and 1 mm thick puttycomplete all as specified and as directed. |
| 58 | Preparation of newly plastered surfaces and applying two coats of oil bound distemper on walls over a coat of primer over a coat of 1 mm thick puttyall as specified & directed. |
| 59 | Preparation of old decorated surfaces and applying one coat of white wash on ceilings all as specified & directed. |
| 60 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 61 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and Brushing neat cement slurry with 3.0kg of cement per sq. metre, complete all as specified and as directed. |
| 62 | Non skid, coloured ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc,set and jointed in neat cement slurry and pointed incoloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed. |
| 63 | Ultracharged/double chargedVitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed. |
| 64 | Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick plaster in cement mortar 1:4, complete all as specified and as directed. |
| 65 | Glazed coloured ceramic jointfree/rectified tiles 350x 250x 7 mm/ 450X 350X 7mm thickon vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed. |
| 66 | Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all asspecified and directed. |
| 67 | Brick work with old size sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed. |
| 68 | Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and as direceted. |
| 69 | Dismantling existing roof padding existing roof treatment, any thickness/type including removing demolished/ excavated materialand depositing where directed or outside MOD land, complete all as specified and as directed. |
| 70 | 10mm thick cement screed in cement mortar 1:3, including finishing even and smooth with out using extra cement to receive roof treatment, mixed with water proofing compound (ratio of WPC and cement - 2%) over and including a neat cement slurry @ 3 Kg/Sqm over cleaned roof surface, as in grading to RCC roof surface, including taking down existing cement plaster from top of roof, scrubbing down with water etc.any description, complete all as specified.Note -Water proofing compound shall be measured and paid separately. |
| 71 | Supply only Integral water proofing compound,complete all as specified and as directed. |
| 72 | Cement concrete 40 mm thick type B-1 1:2:4 (20mm grade aggregate) over cement concrete, complete all as specified and as directed. |
| 73 | Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm all as specified and as directed by Engr-in-Charge.Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise. |
| 74 | Ball valves of size 20 mm bore dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (Minimum weight not less than 210 gms) screwed for iron pipe and fixedincluding necessary fitting as required at site fixed in repair complete all as specified and directed. |
| 75 | Preparation of new steeland iron surfacesexceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide/zink chrome primer complete, complete all as specified and as directed. |
| 76 | Preparation of old steeland iron surfacesexceeding 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 77 | Pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down, high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as directed. |
| 78 | 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed. |
| 79 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 ABS wall hook including making connections and fixed in position, complete all as specified and as directed. |
| 80 | Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, with chromium plated brass screw in wooden/plastic cleat, fixed in repairs, complete alll as specified and as directed, |
| 81 | Providing, Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges, complete alll as specified and as directed, |
| 82 | Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed. |
| 83 | False ceiling with fibre cement designer tile ivory/white painted (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size 595 x 595 mm and any one of the design (occeanic, lake & hill,cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 12 gms, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length, and 15x32 mm made of 0.30 mm sheet, and cross\"T\" at 600mm c/c to form a grid including, required cutting/making, opening for services like diffusers,grills,light fittings, fixures,smoke detectors etc. Main \"T\" runners to be suspended from ceiling using Gl soffit cleats fixed to existing rafter, purlin, etc with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T- sections shall be centra black pre- painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, and refixed all existing electric wiring and fixture all complete at all heights as per direction of Engineer-in -Charge. |
| 84 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. |
| 85 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings incl ridges,complete all as specified and as directed. |
| 86 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 87 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 88 | Fixing only Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 89 | S&F for 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc, complete all as specified and as directed. |
| 90 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 91 | Steel work in tubular trusses , posts , purlinesincluing special shaped,notched forming holes, without any attachment including drilling, fitting, riveting and or welding or connecting with bolts and nuts (incl rivet or nut and bolts) providing and fitting angle cleats ,Gussete plates etc also for wedging plumbing, truing up and fixing complete washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161 -1979 grade St-240 complete all as specified and as directed. |
| 92 | Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe 410-W (Gde-E- 250) quality-A, complete all as specified and as directed. |
| 93 | Handrails 75 X 60 mmrounded or shaped with splayed faces in straight lengths and fixed complete all as specified and as directed. |
| 94 | Steel rolling shutters, having thickness of laths 1.25mm with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type and one shop coat of red oxide primer complete all as specified and as directed. |
| 95 | Safety lever locks mild steel with 4 leavers for rolling shutters complete all as specified and as directed. |
| 96 | Ball bearing for rolling shutters complete all as specified and as directed. |
| 97 | Old concrete surafecand picking up sweeing cleaning abd washing down with water and removal dust etc for depressions od RCC surface and complete all as specified and as directed. |
| 98 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 99 | Plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate)as in foundations filling and mass concrete complete, all as specified and directed. |
| 100 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A\" on 100 mm thick pcc flooring and complete all as spd and as directed. |
| 101 | Material and loabour for epoxy flooring as under: (a) primimg applying 2 pack epoxy resign primer NITOPRIMER 25 for improved adhesion and corrosion protection on the acceptable substrate @ 5 Sqm /litre. primer to air cure for 24 hours before starting floor coating treatment .it must be tack free .(b) Self smoothing 3 component epoxt enderlyNITOFLOR EU 5 in 2 mm thickness wirh exhibiting following compressive strength > 60 n/mm2 @ 7 daysTensilte strength >11 N/mm 2 in 7 days Tensile modules > 880 N/mm 2 in 7 daysFlexural strength22 N/mm 2 in 7 daysWater absorvtion -NilIntinal hardness - 16 Hours Full Cure : 7 Days Crushing strength -2.2N/mm2 in 7 daysAdhesuve : Greater then the tensile strength ofconcrete(c) Under coat on the primer at a material consumption rate 4.0 Sqm /Litre for Nitrofor EPU Conductive undercoat (d) Top Coat :-2mm Nitroflor EPU conductive system as a measure to control static electricty for provideing dense ,impervious ,coloured and chemical resistant floor ,surface should be hygienic and easy to claen . When laid Nitri flor EPU conductive system provides a seamless smooth ,light reflective surface :-Tectional properties :- Specific gravity approb 1.7 Colume soliods 100% , compressive strength > 50 N/SQm @ 27 degree centrigate7 daysTensilte strength > 7 days 10 N/mm2@ 27 degree centrigrate Flexural strength7 days25 N/mm2 @ 27 degree centrigrate Pot life at 30 degree centrigarte approx :- 30 Min and Curing time at 30 Degree Centigreatefoot traffic after 24 hrs ,Full traffic after 7 days . |
| 102 | Transparent Polycarbonate Honeycomb sheet 12 mm thick with transparenct 40to 80%with specific gravity 1.2gm per cm as in roof covering/cladding to wall,fixed withself tapping screws all as specified and directed.\" |
| 103 | Factory made (box type) mild steel window/ventelators glazed and gauged combined shutter with side hung including box type hinges steel peg stay locking arrangement with glazing and gazing bar dovetailed or welded and one shop coat of red oxide primer complete all as specified NOTE (i) The window /ventelator shall be fabricated as per drg No CEUZ/TD/1302/2009 sheet 1/3 to 3/3(ii) MS fillets,glazing,wire gauges shall be measured and paid for seperately.(iii) One side out to out dimensions shall be measured for payment of combined window (glazed & gauged). |
| 104 | Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 Grade, with topping of cement with imported pigment. Shape shall be approved by Engr-in-Charge. |
| 105 | Sand cushioning under floors including watering and consolidation complete all as specified and as directed. |
| 106 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed. |
| 107 | Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling,floors etc, complete all as specified and as directed. |
| 108 | Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as,LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by engineer in charge. |
| 109 | Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductorwiring in and including PVC concealed casing and caping medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable forswitches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed. |
| 110 | Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor, medium grade (ISI marked)marked down into andincluding PVC concealed conduit with all accessories from terminal box to junction of wall and rest of circuit conductor wire drwan into and including surface PVC rigid non metallic conduit for oneceiling fan point controlled by one switch with also including 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed. |
| 111 | Description all as per item No 108 above but for bell/ buzzerpoint controlled by one push button on independentboard with other switch or independent. |
| 112 | Description all as per item above No. 108 but one 3/5 pin 5 Amp socket outlet on independent board. |
| 113 | All as per description of Serial item No. 108 here-in-before but one 3/5 pin15 Amp socket outlet on independent boardwith PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed. |
| 114 | Description all as per item No. 108 above but one 3/5 pin5 Amp socket outleton the same board with other switch. |
| 115 | All as per description of Serial item No. 108 here-in-before but one 3/5 pin15 Amp socket outlet on independent boardwith PVC insulated, unsheathed FRLS cable 1.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed. |
| 116 | Switch piano flush button single pole one way 5/6 Amp, 240 Volts, complete all as specified and as directed. |
| 117 | Switch socket combination, 2 in 1, 3/5 pin, 5/6Amp flush type, complete all as specified and as directed. |
| 118 | Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed. |
| 119 | Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and as directed. |
| 120 | Ceilling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed. |
| 121 | Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed. |
| 122 | Bell push 6 Amps 230 volts complete all as specified and as directed. |
| 123 | Fan regulator 120W, 230V 50 C/S, flush type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed. |
| 124 | Refixing only slim linear LED light fixture 4/5W, 9/10W, 10/12W and 18/20 Watt,LED batten full base of extruded poly carbonate isolated driver complete making all connection from ceiling rose to fittings, complete all as specified & directed. |
| 125 | Refixing only serviceable high bay LED lighting fixture 90 Watt,complete all as specified & directed. |
| 126 | Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as per the directions of Engr-in-Charge. |
| 127 | Supply and fix Wall/ Column mounted air circulator insulated type Fan heavy duty 750mm (\"30\") air delivery capacity 13066 CFM sweep 1440 RPM, 250 watt steel body, AC single phase, 240V, 3 blade wall/columnmounted with complete accessories all as specified and as directed. |
| 128 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with provision of cable 3 core flexible copper conductor 23/0.0076 from ceiling rose to ceiling fan including fixing and connecting up of fan regulator complete all as specified. |
| 129 | LED lights fitting 1x 20W, 230V, high quality LED batten with Aluminum Extrusion housing with PC diffuser,CRI > ,80 efficacy : 120 Lm/W , IP-20 complete including connecting up with flexible copper wireof suitable size from ceiling rose to LED complete all as specified and as directed. |
| 130 | S&F in replacement environmental friendly, new generation,aesthetically designed, ultra modern, glare-free symmetric light distribution SURFACE mounting luminaire with high efficiency long life LED integral module as light source, 36 Watt 2\"x2\" LED flat Panel luminire with SELV Output electronic LED driver (SMPS based constant current supply) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting: CRCA powder coated(b) Diffuser : High transmittance polystyrene opal diffuser(c) Operating Voltage: 150 V- 270V(d) Operating Temperature : -10 to +45 Degree Centigrade(e) Lumen efficacy : Not less than 100 lm/W(f) System Lumens: Not less than 3600 lm(g) Colour Temperature : Not less than 5700K(h) Surge Voltage Protection: Up to 2KV(j) Ingress protection: IP 20(k) Total Harmonic Distortion (THD) : Not less than 20%(l) Power factor : Not less than: 0.9(m) Line protection: Under/Over voltage Protection (n) Input Frequancy : 50 Hz(o) Dimension of fitting : (600 x600 x 50)mm |
| 131 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to and including4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :-(a) Excavation and earth work for drilling hole for electrodein any type of soil.(b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC coverwith suitablehandle 40 mm thickinPCC1:2:4type B-1,reinforced with welded steel wirefabric weighing notless than 1.87 Kg/Sqm.(d) Funnel with watering pipe of GI20 mm nominal bore medium grade and copper lugs etc all as specified. |
| 132 | Srl item No 130 Contd …(e) 15 mm nominal bore light grade GI protection pipe 7.5 mtrlongforprotectionof earthing lead from mechanical injury or tempering.(f) Requisite quantity of common salt and charcoal.(g) Testing of earthing.Note : On testing after completionof earthing, ifthe desired earth resistanceisnotobtained,theearthingwill bere-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. |
| 133 | VTPN distribution board, vertical including MCCB 250 Amp , 16kA (as incommer) 6 way, with metal door 415Volt grade, double door IP-43 protection, fixed in repairs complete all as specified and directed. |
| 134 | MCCB4 pole, 415 volts 160 Amps with breaking capacity 36 KAwith thermal adjustble, complete all as specified and as directed. |
| 135 | Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V, 50Hz with bus bar,neutral link, Earth bar and Din rail, powder coated double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB andmaking good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed. |
| 136 | Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar,double door typeincluding cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. |
| 137 | Sheet metal enclosures for distribution board when MCB to be used SPN 02 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar,double door typeincluding cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. |
| 138 | Supply and fix Tripple pole & earth enclosure with 3 pin and earth plug and socket complete with TPN MCB 63Amps,240V complete all as specified and as directed. |
| 139 | Supply and fix sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps,240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed. |
| 140 | MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA \"B\" Series including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed. |
| 141 | MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA \"B\" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed. |
| 142 | Isolator Four pole, 100 Amps, 240 V/415V, complete all as specified and as directed. |
| 143 | Energy saving, environment friendly suspened type PDC aluminium housing with PC ilens cover & mounting eye bolt with IP-65 UFO LED highbay light 90 watt(125Lm/W) complete all as specified and as directed. |
| 144 | Energy saving, environment friendly, pressure die casted aluminium housing with toughened glass polted driver with IP-66 LED flood light fittings 90 watt (125Lm/W) with high efficacy & lower power consumption delivers high brightness, fixed in repairs, complete all as specified and directed |
| 145 | M&L for sub main wiring with copper conductor cable (4 runs of cable) multistranded 10 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC rigid concealled conduit not less than 40 mm dia and 2 mm wall thickness ISI marked medium grade , with all conduit accessoriesfrom LT panel to TPN DBs such that GI shadle, GI screw, rowl plug etc. including cutting chasing and 2X10 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire, including taking down old sub main wire,complete all as specified and directedNote:- 4 runs of 10 Sqmm (4x10sqmm ) ,2 run of 10 Sqmm (2x10 sqmm ) cable and one metre of conduit will be measured as one unit. |
| 146 | Sub main wiring with tworuns of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceilingetc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire, including taking down old sub main wire, complete all as specified and directed. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit. |
| 147 | Sub main wiring with tworuns of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceilingetc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire,including taking down old sub main wire, complete all as specified and directed. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit. |
| 148 | Sub main wiring with copper conductor cable (2 runs of cable) multistranded 2.5 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC rigid concealled conduit not less than 25 mm dia and 2 mm wall thickness ISI marked medium grade , with all conduit accessories for round ceiling light/round ceiling light recessed type/ foot lamp/focus light/ 2x2 panel light such that GI shadle, GI screw, rowl plug etc. including cutting chasing and 1x2.5 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire,including taking down old sub main wire, complete all as specified and directed.Note:- 2 runs of 2.5 Sqmm (2x2.5sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit. |
| 149 | Building security light of 35 watt, new generation energy saving and environmental friendly long life made up high pressure die castaluminium housing with modular lens having efficiency with IP-66 including provision of GI tubing bracket of suitable size and fixed on wall including clamps, nuts, bolts, washer for fixing of security light fixed in repairs,complete all as specified and directed. |
| 150 | Supply, laying / fixing and testing in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing,complete all as specified and as directed. |
| 151 | Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, and for laying of cable or pipes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outin any type of soil, complete all as specified and as directed. |
| 152 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed. |
| 153 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed. |
| 154 | Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose. |
| 155 | Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed. |
| 156 | GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed. |
| 157 | ON load change over switch (side handle) 200 Amps 4 polein sheet enclosure 415 Volt, complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail