| Sl. No. | Item Description |
| 1 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed |
| 2 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed. |
| 3 | Taking down or up 15 mm bore galvanised iron tubing and connection including cleaning for refixing or removal all as specified |
| 4 | Taking down or up 20 mm bore galvanised iron tubing and connection including cleaning for refixing or removal all as specified |
| 5 | Providing and fixing CPVC pipes upto 20 mm outer dia conforming to IS 15778 Class 1 (SDR 11) or Class 2 (SDR 13.5) for hot and cold water supply, complete with all plain CPVC fittings (elbows, tees, sockets, reducers, couplings, end caps,) without metal inserts, solvent welded using one-step yellow CPVC solvent cement or two-step CPVC primer + cement , properly cut and grooved where specified for mechanical couplings, including Cutting chases in brick, stone, concrete block or slab wall pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, securing with CPVC saddles/clips at 1m centres (max 1.5m), true to line and level with minimum 50mm cover from finished wall surface, including cutting, threading/grooving, jointing, and proper testing for any water leakage complete all as specified and directed by Engr in charge. |
| 6 | Supplying brass threaded CPVC fittings upto 20 mm outer dia (FTA - Female Threaded Adaptor, MTA - Male Threaded Adaptor, Brass Elbows, Brass Tees, Unions, Ball Valves, Flanges, Tank Adaptors etc) conforming to ASTM F437/F438/F439 with metal inserts, for connection to taps, showers, fixtures, storage tanks, complete with CPVC solvent cement jointing on pipe side and threaded brass connection complete all as specified and directed by Engr in charge. |
| 7 | Demolition of brick work or stone/boulder masonry, built in cement mortar incl. all quoins arches, pillars etc. but excluding ashlar facing, dressed stone work andprecast concrete articles, complete all as specified and directed. |
| 8 | M&L brick work in CM (1:6) with sub class ‘B’ bricks straight or curved on plane exc 6m mean readius, used in drain, boundary wall, compound wall complete all as specified and directed by engr in charge. |
| 9 | Demolition of concrete is reinforced (Reinforcement cut as required to facilitate demolition)of any description and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge |
| 10 | M & L for Reinforced cement concrete 1:1.5:3 using 20 mm graded aggregate Slabs supported on walls, beams and in kitchen shelves and the like items complete all as specified and directed. |
| 11 | M&L TMT steel bars 6mm to 8mm dia and over cut to length bent shape required, including cranking bending binding with mild steel wire (annealed) not less than 0.9mm dia quality conforming to relevant IS complete all as specified. |
| 12 | M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work to provide smooth finish; not exceeding 200mm thick (Horizontal or sloping) complete all as specified. |
| 13 | Taking down cement plaster including raking out joints hacking for key and scrubbing down with water complete as specified and directed. |
| 14 | M&L for 10mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and smooth without using extra cement all as spfd and directed. |
| 15 | M&L for 15mm thick rendering in CM 1:4 on other than fair faces of brick or concrete surfaces finished even and smooth without using extra cementall as spfd and directed. |
| 16 | M & L for rendering 5 mm thick on ceiling on fair faces ofbrick or concrete surface in CM (1:3) finished even and smooth without using extra cement all as specified |
| 17 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 18 | M & L for 75 mm thick PCC 1:3:6 type C2 as in plinth protection finished even and smooth without using extra cement as specified |
| 19 | Forming Construction joint grade A 30mm deep x 10mm wide filled with sealing compound complete all as specified. |
| 20 | Demolition of cement concrete of any description & in any position not otherwise specially provided foretc complete all as specified & directed. |
| 21 | Disconnecting existing water storage tank up to 500 litre capacity, setting aside/lowering for cleaning or repairs, cleaning and removing all scale, dirt, etc. from tank and mouths of circulating pipes, and after completion hoisting (if required), reconnecting and re-fixing in original position, complete all as specified and as directed by Engineer-in-Charge. |
| 22 | S & F 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top ) including dismantling andhoisted and fixed in position etc completeall as per specified and directed. |
| 23 | S & Fin repair 20 mm bore ball brass valves (Float valve) high pressure with polythene float and fly nut complete screwed to iron pipe or brass ferrule complete all as specified |
| 24 | S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm prelaminate PVC sheet, reinforced with MS square tube fixed in opening with smooth finish complete as per manufacturer\"s specifications and as directed by Engineer-in-Charge |
| 25 | S & F Factory Made Solid PVC Moulded Door Shutter with particle board, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing specified in SSR andas directed by Engineer-in-Charge |
| 26 | S&F, 100 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed , type C-21 complete all as specified and as directed. |
| 27 | S&F 150 mm size aluminium handles, cast type anodised and fixed complete all as specified and as directed. |
| 28 | S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. . |
| 29 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 125 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/lugs/SS dash fasteners of required dia andlength complete as per direction ofEngineer-in-Charge. |
| 30 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 100 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia andlength complete as per direction ofEngineer-in-Charge. |
| 31 | M & L for PCC 1:2:4 type B1 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and |
| 32 | S&F35mm thick factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture roof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 33 | S&F35mm thick factory made single extruded WPC (Wood Polymer Composite) skeleton shutters, open rebated and with SS wire gauze dia 0.63mm and average width of aperture 1.4mm in both side decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture roof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 34 | S & F 200 mm mild steel barrel tower bolts stove enamelled black with bright bolt and fixed complete all as specified and as directed. |
| 35 | S & F 300 mm mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and as directed. |
| 36 | S & F 100 mm size mildsteel butt hinges medium weight cold rolled andfixed with screws or welding where required complete all as specified and as directed. |
| 37 | S & Fmild steel pressed handle 150 mm long oval types stove enamelled black complete all as specified and as directed. |
| 38 | S&F floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring over all length 140mmcomplete all as specified and as directed. |
| 39 | S&F factory made white colour casement UPVC windows(openable) are made of UPVC extruded profile with wall thickness of (2.3mm to 2.5mm), window profile with hollow section with multi chamber, Frame(50mmx30mm), sash (74mmx34mm), mullion profile (one vertical length in between frame and shutter 72mm x32mm), glazed through 5mm thick frosted glass with glazing bead (28mmx26mm) will be metered cut and fusion weldedat all corners, including provision of suitable opening/cut-out for fixing exhaust fan of approved size, providing and fixing stainless steel mosquito wire mesh, drilling of holesfor fixing hardware with handle (150mmx17mm), suitable hinges(75mm) and drainage of water etc making arrangementof fixing of hardware, EPDM gasket(1.mm to 3mm) thick, GI of (1.2mm tto 1.5mm) thick to be inserted in required profile , fame will be fixed by wall with 8mmx100mm long fasteners complete including taking down old window/ventilator any size and making good disturbed portion complete as per manufacture\"s specificationand direction of Engr-in-Charge |
| 40 | S&F factory-made white colour uPVC window with convertible Window-AC provision, made from uPVC extruded profiles having wall thickness 2.3–2.5 mm with hollow multi-chamber sections, comprising uPVC frame 91 mm × 47 mm, divided into upper openable portion and lower sliding AC compartment; upper portion consisting of uPVC openable shutters (60 mm × 34 mm) with one shutter glazed with 5 mm thick tinted glass and one shutter fitted with SS wire mesh, fixed with glazing bead (18 mm × 16 mm) and provided with approved handles, locking arrangement and hinges; lower portion comprising sliding uPVC shutter/panel suitably reinforced with GI reinforcement 1.2–1.5 mm thick, arranged to slide open for installation of Window AC and to close fully when AC is not provided, ensuring rigidity and weather tightness. All profiles to be meter-cut and fusion-welded at all corners, including drilling of holes for fixing hardware, complete with EPDM gasket (1.2–3 mm thick), touch lock where required, roller wheels, water drainage arrangement and all necessary fittings. Frame to be fixed to wall with 8 mm × 100 mm long fasteners, including taking down existing window/ventilator of any size and making good disturbed portions, complete all as per manufacturer’s specifications and directions of Engineer-in-Charge. |
| 41 | Note:- The above item includes S&F mild steel safety grill fabricated from approved MS flats/bars, cut to size, welded, ground smooth and finished, fixed to masonry/RCC or window frame with approved holdfasts/clamps/anchor fasteners, painted with one coat of red oxide zinc chrome primer and two coats of synthetic enamel paint, without affecting smooth operation of UPVC shutters, mesh sash, locking or drainage system, including making good disturbed surfaces, complete all as specified and directed by Engr-in-Charge. No extra claim by the contractor for the same |
| 42 | S & F 15 mm thick colour artificial granite slab/tile over 15 mm thick screed bed as in floors etc and jointed in neat cement slurry and pointed in white or coloured cement to match, including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and as directed. All dismantling/demolished material to be removed from MoD land completely. Rate of removal outside of MoD land deemed to be included in the same item complete all as specified and as directed. . |
| 43 | Rounding to the edge of stone slabs on edge such as cooking platform complete all as specified and as directed. |
| 44 | S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, also including waste coupling and waste pipe complete all as specified. |
| 45 | Note:-Fixing stainless steel kitchen sink of approved make and size, under-mount type, with top level flushed with artificial granite platform, including cutting/making opening in artificial granite stone to required shape and size, fixing sink in position properly embedded and secured using epoxy/approved adhesive and cement mortar, providing and fixing necessary clamps/brackets, sealing all around with approved silicone sealant to make the joint completely leak-proof, complete all as specified and as directed by Engineer-in-Charge. No extra claim for the same |
| 46 | M&L for gunniting to RCC works in column, beams, slabs, chajja, facia, landing, balconies etc by removing/ dismantling of RCC(loose concrete) including plasterand cutting of steel barincluding plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sika top Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing welded steel wire mesh 75mm x75mm with 4mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka.Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcmand applying 25mm to 100 mm thick (avg thickness )gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) with 15 mm thick plastering(1:4) using ordinary port land cement of 43 grade over wherever required at any height, complete all as specified and directed by Engineer-in-Charge.Note:-(i)After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with.(ii)Additional reinforced TMT barswhere incorporated in work and including 20mm thick cement plaster in 1:4 to be included in quoted rate (iii)Work to be carried out as in patches as directed by Engr-in-charge.(iv)Rate for steel scaffolding as directed to be included in quoted rate.(v) All demolished material removed from MOD land completely. |
| 47 | M&L for treatment of sunken portion of slab in bathroom/toilet complete as mentioned below all as spfd and directed:-(i) Taking down carefully existingsunken portion in bathroom/toilet by taking out plaster,concrete/brick bat filling/tiling including plumbingfrom the sunken floor and wall upto RCC slab. Roughing the surface with wire brushingcleaning and washing with water etc and removing the rubbish to a distance exceeding 5mm but not exc 1 km and deposited where directed.(ii) Cleaning the concrete surface of sunken portion of slab as obtained after demolition/taking down of existing sunken portion of slab thoroughly with wire bruses, washed and dried.(iii) checking the sunken slab by ponding test with water till total elimination of leakage/seepage/dampness all as spfd in SSR part-I (after ascertaining location of leakage/dampness carrying out treatment pressure grouting shall be operated at the required locations.(iv) Provide 50mm thick (average) PCC 1:2:4 mixed with water proofing compound as per manufacture instructions shall be provided at the bottom of sunken portion with proper coving on sides and 15mm thick cement plaster 1:4 with water proofing compoundon sides. PCC and plaster shall be carried out at same timeovertwo coats of polyuerthane based chemicaltreatment as per manufactures instructions complete all as spfd(v)After laying of all CI connection and branch pieces etc apply two coatsof polyuerthane based chemical treatment over vertical sides and floo of sunken portion.(vi)All the joints of pipes with the wall shall be sealed properly by chemicalafter these are filled with PCC 1:2:4 miexed with water proofing compound(vii) The sunken portion shall be filled with plain cement concrete 1:2:4 with graded brick aggregate/bat after carrying out required test for CI pipes/joints/water proofingNotes:(i) For payment purpose plan of floor area shall be measured(ii) After coating of water proofing compound ponding test shall be carried out by filling the sunken surface with water for 72 hours and get approved from Engr-in-charge if any leakage/seepage noticed, the contractor withoutany extra payment. |
| 48 | (v)After laying of all CI connection and branch pieces etc apply two coatsof polyuerthane based chemical treatment over vertical sides and floor of sunken portion.(vi)All the joints of pipes with the wall shall be sealed properly by chemicalafter these are filled with PCC 1:2:4 mixed with water proofing compound(vii) The sunken portion shall be filled with plain cement concrete 1:2:4 with graded brick aggregate/bat after carrying out required test for CI pipes/joints/water proofingNotes:(i) For payment purpose plan of floor area shall be measured(ii) After coating of water proofing compound ponding test shall be carried out by filling the sunken surface with water for 72 hours and get approved from Engr-in-charge if any leakage/seepage noticed, the contractor shall rectify withoutany extra payment. |
| 49 | Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc.complete all as specified and as directed. |
| 50 | Dismantling of cast iron drain pipe of 100mm bore jointed in lead joints or cement joints and taking out of under floors if required complete all as specified and as directed. |
| 51 | S & F 100 mm dia cast iron soil waste and vent pipes sand cast in any length with or without laid in trenches or in floor with cement joints complete all as specified and as directed. |
| 52 | All as per item No 48 here in before but fixed to walls complete all as specified and as directed. |
| 53 | S&F in repair of 75 mm bore cast iron drain drain/waste/vent pipes fixed to wall, floor jointed with lead joints incl dismantling of old cast iron drain, waste, vent pipe of any description , jointed with any material complete all as specified and as directed. . |
| 54 | S & F cast iron floor trap with grating of 75 mm size including jointing to waste pipe with cement joints etc complete as directed |
| 55 | S & F cast iron floor trap with grating of 100 mm size including jointing to waste pipe with cement joints etc complete as directed |
| 56 | S & F 100 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured) fitted with access door complete all as specified and directed |
| 57 | S&F in repair ofCast iron branch pieces , tee equal or unequal spigot or socket type or with parallel branches to 100 mm dia pipe fitted with access door complete all as specified by Engineer-in -Charge . |
| 58 | S&F in repair vitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including fixing of tap, waste fitting and union complete all as specified and as directed. |
| 59 | S&Fin repair 15mmdia bore cast copper alloy fancy type mixer pillartap for cold and hot water complete all as spfd and directed |
| 60 | S&F 32 mm bore of pipe low density (LDPE) of pressure rating 6 kg/ sqcm fixed to wall or floor etc including fittings complete all as specified and as directed. |
| 61 | S & F32mm dia waste fitting brass chromium plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 62 | S & F in repair PVC connection 15 mm size with CP nuts of length 600 mm etc complete all as specified. |
| 63 | S&F bib tap long body of CPfancy type with butterfly handle screwed down screwed for iron pipe of 15mm bore fixed in repairs |
| 64 | S&F angle valves CP screwed down high pressureof fancy type chromium plated screwed both ends for iron pipe or for union and fixed with 15mm bore in repairs |
| 65 | S&Ftwo way angle cock CP screwed down high pressureof fancy type chromium plated screwed both ends for iron pipe or for union and fixed with 15mm bore in repairs |
| 66 | S&F in repair of brass chromium plated shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and as directed |
| 67 | S&F in repair of CP soap tray fixed to walls with rubber plugs complete all as specified and directed. |
| 68 | S & F of sink mixer 15mm bore dia cast copper alloy with cap capstone chromium plated screwed down high pressure with or without letter Hot and Cold with long screwed and fly nuts screwed for iron pipe complete all as specified and as directed. |
| 69 | S & F of wall mixer three in one type 15mm boredia cast copper alloy with cap capstone chromium plated screwed down high pressure with or without letter Hot and Coldwith long screwed and fly nutsscrewed for iron pipe complete all as specified and as directed. |
| 70 | S&F in repair brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed. |
| 71 | S&F in repair of PVC bath room cabinet with mirror of size 432 mm x 311 mm complete all as specified and as directed. |
| 72 | S&F in repairs stainless steel curtain rod of dia 25 mm complete all as specified and as directed.. |
| 73 | S&F Stainless steel bracket with finals for holding curtain rods of dia 25 mm as approved complete all as specified and as directed. |
| 74 | S&F for stain less steel kitchen plate rackSize 24 inch x 30 inch size complete asdirected by Engr -in-Charge |
| 75 | S&F in repair vitreous china wash down water closet pal (pedestal pattern) white (excluding fixing bolts flushing cistern and slush pipe) with seat cover with CP screw complete all as specified and as directed. |
| 76 | S & F in repair PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve float and handle etc complete all as specified & directed. |
| 77 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 78 | S & F 110 mm bore of pipe PVC (SWR) pipes double socket in any length with rubber ring joint fixed to walls with MS clamps as directed |
| 79 | S & F 110 mm bore of pipe PVC (SWR) bends with access door of any radius / shoefixed to PVC pipes as directed |
| 80 | S&F in repair of glazed ceramic coloured tiles 7mm thick 450 x 300mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. Etc including 10 mm thick rendering in CM 1:4 including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 81 | S&F non-skid ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm with 15 mm thick Screed bed or bedding layer in CM (1:6) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified. |
| 82 | S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 32 mm bore (Spout pipe for sunken portion) complete all as specified. |
| 83 | Re-baring by drilling holes and fixing nozzle if required in existing concrete/brick work as in column, beams, slabs and foundation etc in any position and any description size of hole 14mm, 16mm & 22mm suitable for dowels of size 10mm, 12mm & 16mm respectively (minimum depth 140mm for 10mm & 12 mm dia bars and 180mm for 16mm dia bar, cleaning the surface properly with blow out pump & round brushes and fixing of dowel bars with epoxy resin (resin+hardner).Make: Sika, Fosroc or concressive 1450 of BASF complete all as specified and directed by Engr-in-charge. Note:-(i)Adequate lap length shall be provided as per IS-456-2000.(ii)Reinforced TMT bars where incorporated in work will be paid under item no 4&5.(iii)The work shall be carried out upto four storied building with scaffolding. |
| 84 | M&L for providing and applying corrosion resistance non-shrink free flow, cementitious one component Micro-concrete with average thickness 75mm having compressive strength (BS 4551-80-60) 50 MPA at 28 days, Tensile strength (ASTM C 348)-2.0 N/mm2 @ 28 days, Flexural strength (ASTM C 348)-9 epoxy bonding agent TM bond EP thermax having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days bond strength (ASTM C 881)- 11 N/mm2 at 7 days, having an over lay time of 3 hrs at 30°C pouring of micro concrete into the formwork using suitable arrangement or if required using pumping device for and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate etc including all tools and tackles as per accepting office, complete all as specified and directed by Engineer-in-Charge. |
| 85 | Dismantling boarding ,any description, fixed in any position with nails etccomplete all as specified & directed. |
| 86 | Supply and fixing 12mm thick pvc ply with suitable fully threaded steel screws etc on the backing of rack, drawer, cupboard, kitchen cabinet under kitchen counter etc all complete as per direction of Engineer-in-charge. |
| 87 | S& F 18/19mm thick ply both side balancing white with 1mm thick lamination, BWP marine grade ply as per IS 710 in partitions, boxes, shelves racks , almirah cupboard, and drawer etc includingnecessary \"L\" SS buttons, nails , screws etc including 2mm thick PVC edge bending tape with hot glueby edge banding machine etc with necessary fittings and fixture complete all as spfd and as directed. |
| 88 | S& F 18/19mm thick ply both side cup board shutter balancing white with 1mm thick lamination one side decorative and other side balancing white , BWP marine grade ply as per IS 710 includingnecessarynails , screws etc including 2mm thick PVC edge bending tape with hot glueby edge banding machine and soft closing hinges etc with necessary fittings and fixture complete all as spfd and as directed. |
| 89 | S & F Brass 4 lever locks, cupboard, grade I, size 50 mm complete all as specified and as directed. |
| 90 | S&F Magnetic catcher for Wardrobe, Cub-boards Etc complete all as specified and as directed. . |
| 91 | Supply and fixing stainless steel fancyGrade 304 handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 92 | Supply and fixing heavy type telescopic drawer channels HETTICH or equivalent 500 mm long with necessary screws etc. complete as per approved and directions of Engineer-in- charge. |
| 93 | S&F 100 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. . |
| 94 | Dismantling of wrought iron orMild Steelwork of any description complete all as specified and directed by EIC complete all as specified and as directed. |
| 95 | S & FISI marked hydraulically regulated door closer die aluminium body type complete suitable for door shutter width of 851 to 1000 mm and weight between 61 to 80 kg all as specified. |
| 96 | Providing and fixing ISI-marked concealed type L-Bihari hinges, 35 mm cup size, heavy-duty, suitable for 19 mm thick plywood shutters, complete with soft-close mechanism, screws and all accessories, including 0° crank for full overlay shutters, 9° crank for half overlay shutters and 18° crank for inset shutters, fixed in position after drilling holes in shutters and carcass, adjusted for smooth operation, complete all as per manufacturer’s specifications and directions of Engineer-in-Charge. |
| 97 | S&F in repair Aluminium door seal width of 1.50 inch with nylon brush fitted with screw complete all as specified and as directed. |
| 98 | M & L for Rolled Steel section (Fe -410, Grade E-250) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. The work may be executed upto four storey bldg and for window chajja upto 15 mtr height. |
| 99 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mapas in chajja/roof covering/cladding to wall, fixed with self-tapping screws to steel frame work, as specified. Note: PPG Sheet shall inserted in wall for window chajja and other at four storey bldg with cutting chasing of brick wall. No extra claim by contractor for same. |
| 100 | Complete taking down/demolition carefully any type of existing roof treatment i.e. mud puska, brick coba, brick tiles, any type of tiles, PCC, plastering, leeping etc. of any type and thickness varying from 20mm to 200mm in roofs including cleaning the surface after removal (removing the rubbish) complete all as specified and as directed.Note:- Rate ofremoval of debris outside from MoD land deemed to be included in the same item. |
| 101 | Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and slurry 1:3complete all as specified and as directed. |
| 102 | M&L for nominal mix of cement concrete Type B0(1:11/2:3) using 12.5mm graded aggregate as in roof for maint the uniform slope all as directed by Engr-in-Charge |
| 103 | Surface preparation and applying cement screed bed of 10 mm thick 1:4 with water proofing compound @ 3% weight of cement as per manufacture instruction with APP modified polymeric membrane centre core of 100 micron HMHDPE, weight not less than 3 Kg/Sqm and clear thickness of membrane not less than 3 mm thickness, on newly prepared surface with overlap while torching shall be 100mm on length side & 100mm on width side of membraneas per manufacturer instruction complete all as specified and as directed with the following description.(a) Apply evenly a coat of bituminous primer conforming to IS -3384 @ 0.40 Kg/Sqm.(b) A coat of bonding bitumen confirming to IS -702 of grade 85/25 @1.20 Kg/Sqm as IInd course.(c) Laying of APP modified polymeric membrane as a IIIrd course. (d) Two coat of aluminium paint and application by brushing @.25 Kg/sqm on APP membrane as a forth course. |
| 104 | Supply only integral water proofing compound ISI Marked complete all as specified and directed by Engr-in-charge. |
| 105 | M & L for preparation of new plastered surfaces of walls and applying two coat of Oil Bound distemper over a coat of 1mm thick wall care putty on wall, complete all as specified. |
| 106 | M&L for preparation of new plastered surface of walls and applying two coat of exterior weather proof water base emulsion paint (APEX) of any color complete all as specified & directed.Note:- Quoted rate shall be deemed to be included for work in buildings/structure upto 15mtr height. |
| 107 | M&L for complete removal of old existing treatmentof walls surfaces and applying a coat of white cement base wall care putty in patches as required and as directed by Engr-in-Charge finished even and smooth with sand paperand applying two coat of exterior weather proof water base emulsion paint (APEX) of any color all as specified & directed.Note:- Quoted rate shall be deemed to be included for work in buildings/structure upto 15 mtr height. |
| 108 | M & L preparation of newly plastered surfaces and applying two coats of distemper oil emulsion with one coat of putty on ceiling incl preparation of surfaces complete all as specified and as directed. . |
| 109 | M&L for preparation of old surfaces including complete removal of old existing treatment of wall surfaces and applying two coat of Oil Bound distemper over a coat of 1mm thick wall care putty on wall, |
| 110 | M & L preparation of new surfaces of steel and iron work of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed. |
| 111 | M&L for preparation of old paintedwooden surfaces over 10 cm width or girth and applying onecoat of synthetic enamel paint etccomplete all as specified and as directed. |
| 112 | M & L preparation of old painted surface of steel and iron work of any description over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and as directed. |
| 113 | Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed. |
| 114 | Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed with all fittings including tees , junction boxes, modular GI gang box & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified & directed by Engineer -In-Charge.Note: 1) Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.2) Rates are deemed to be inclusive of Modular GI gang box & cover plates of any module & Qty as required on site. |
| 115 | For one light point/call bell controlled by one single pole switch & socket complete all as specified and as directed. |
| 116 | For one fan/exhaust fan point controlled by one single pole switch complete all as specified and as directed. |
| 117 | For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm complete all as specified and as directed. |
| 118 | For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size complete all as specified and as directed. |
| 119 | For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size complete all as specified and as directed. |
| 120 | Supply and Fixing in replacement of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 121 | Supply and Fixing in replacement of modular switches 2 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 122 | Supply and Fixingin replacement of modular Socket, 6A - 2/3 pin combined 2 module with shutter, complete all as specified & directed by EIC. |
| 123 | Supply and Fixing in replacement of modular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 124 | Supply and Fixingin replacement of modular Socket 6A/16A - 2/3 pin combined 2 module with shutter, complete all as specified & directed by EIC. |
| 125 | S&F in replacement of Single pole and neutral enclosure with a two pin and earth including plug and socket complete set with one single pole MCB of 20 Amps, complete all as specified and directed. |
| 126 | S&F Fan in replacement of modular fan regulator 4 step, 2 module, complete all as specified & directed by EIC. |
| 127 | S&F in replacement of Modular Bell push 6A 1 module,complete all as specified & directed by Engineer - In-Charge. |
| 128 | S&F in replacement of Ding Dong AC. 230 volts, single pole,complete all as specified & directed by Engineer - In-Charge. |
| 129 | Supply & Fixing in replacement of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge. |
| 130 | Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified.Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. |
| 131 | S&F in replacement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge . |
| 132 | S&F in repalcement of MCB SPN 40 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge . |
| 133 | S&F in replacement of submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ Geyser/ AC plug points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 134 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised iron wire 4sqmm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated complete all as specified and directed. |
| 135 | S&F in replacement of LED retrofit tubelight, 4 ft longof 20 watt,complete all as directed. |
| 136 | S&F in replacement of LED2 ft retrofit tubelight of 10 watt,complete all as directed. |
| 137 | S&F in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. . |
| 138 | S&F LED Bulb 12 watt E-pin, complete all as specified & directed. |
| 139 | S&F in replacement Powder coated pressure die cast aluminium compact LED building light/ street light of 45watt confirming to IP 65, complete all as specified and as directed by Engineer -in-charge. Make: Crompton cat No: LSTS-45-CDL or equivalent Note: Twin core copper wire of 1.5 Sqmm upto 7Rm required for connection of street light fitting is deemed to be included in quoted rates |
| 140 | S&F in replacement of Street light bracket of size 40mm dia light grade GI pipe, including nut, bolts, Fastner etc, complete all as specified & directed. |
| 141 | M&L in replacement of invertor wiring with one single core PVC insulated of size 1.5 Sqmm unsheathed copper conductor FRLS 1100 Volt grade multistandard complete all as specified and directed by Engr-in-charge. |
| 142 | Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings , connections as required at site of size 20 mm bore, complete all as specified and directed. Note: Cost for fixing of GI pipe on wall upto 5 storey building /21mtrs height with heavy duty fastner & clamp, T&P & labour required for same is deemed to included in quoted rates. |
| 143 | All as per Item No 135 Above butBore of pipe 25 mm, complete all as specified and directed. |
| 144 | S&F in replacement of Stop valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size 20 mm bore, complete all as specified and directed. Make- Zoloto, Leader, Sant, Kartar |
| 145 | All as per Item No 137 Above butBore of pipe 25mm, complete all as specified and directed. |
| 146 | S&F in replacement of GI union of 20 mm ISI marked complete all as specified and directed by Engr-in-charge. Make- Unik/Tata/Jindal |
| 147 | All as per Item No 139 Above butBore of pipe 25mm, complete all as specified and directed. |
| 148 | Supply and fixing in replacement of PVC float valve, high pressure (ball cock bady with epoxy coated aluminium rod & HD ball) of size 50 mm dia.including all fittings, complete all as specified and directed. Make- prayag or equivalent make |
| 149 | S&F in replacement single phase Direct on line starter of capacity 2 HP overload relay range 9-14 Amp.Make- L&T Cart part No: CS90319KOAO /Havell\"s/ Seimens/ Schineder or equivalent ISI marked. |
| 150 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed by Engr-in- charge. |
| 151 | Retuning filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge. |
| 152 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall as specified. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail