| 1 | Taking out or downdefective Fire hydrant valve oblique pattern from main line andopening carefully old defective Fire hydrant valveof any description and in any position for and including servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the Fire hydrant valve after repair and refixing the same & testing after installation complete all as specified and directed. Note:- (i) Spare part will be measured and paid for separately as supply onlyunder appropriate items of Schedule ‘A’ |
| 2 | Supply only Gun Metal hydrant coupling 63mm suitable for existing Fire Hydrant valve complete all as specified and directed. |
| 3 | Supply only cast iron Wheel suitable for existing Fire Hydrant valve complete all as specified and directed. |
| 4 | Supply only Gland nut of gun metal suitable for existing Fire Hydrant valve complete all as specified and directed. |
| 5 | Supply only Rubber packing for coupling suitable for existing Fire Hydrant valve complete all as specified and directed. |
| 6 | Disconnecting and taking out carefully old unserviceable MS pipe and Supply & laying in trenchesMS class `C\" (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring,removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required, nominal dia 150 mm dia size including welding, complete all as specified and directed. |
| 7 | Disconnecting and taking out carefully old unserviceable MS pipe and Supply & laying in trenchesMS class `C\" (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring,removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required, nominal dia 100 mm dia size including welding, complete all as specified and directed. |
| 8 | Disconnecting and taking out carefully old unserviceable MS pipe and Supply & laying in trenchesMS class `C\" (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring,removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required, nominal dia 80 mm dia size including welding, complete all as specified and directed. |
| 9 | Disconnecting and taking out carefully old unserviceable butterfly valve and supply & fixing butterfly valve (suitable for test pressure of PN1.6) 150 mm dia both end flange and drilled and fixed by means of bolts, nuts and washers including providing rubber insertion of suitable thickness, complete all as specified and directed. |
| 10 | Disconnecting and taking out carefully old unserviceable butterfly valve and supply & fixing butterfly valve (suitable for test pressure of PN1.6) 100 mm dia both end flange and drilled and fixed by means of bolts, nuts and washers including providing rubber insertion of suitable thickness, complete all as specified and directed. |
| 11 | Disconnecting and taking out carefully old unserviceable butterfly valve and supply & fixing butterfly valve (suitable for test pressure of PN1.6) 80 mm dia both end flange and drilled and fixed by means of bolts, nuts and washers including providing rubber insertion of suitable thickness, complete all as specified and directed. |
| 12 | Supply and fixing Landing Valve, Single Outlet, Stainless steel, SS 304 grade, 75mm/80 mm N.B. Flanged inlet, SS-304 spindle, 63mm female inst. Oblique outlet, complete with ABS blank cap & chain, bearing IS: 5290 marked (type-A), flange O.D. 200mm, PCD 160mm, four 19mdia holes complete all as specified and as directed. |
| 13 | Supply and fixing Landingvalve, double outlet,Stainless steel , SS 304 grade, , with 100mm N.B. flanged inlet, brass spindle, two individuallycontrolled 63mm female inst. outlets, completewith ABS blank caps and chains, bearing IS:5290 marked (type-B), flange O.D. 220mm, PCD 180mm, eight 19mm dia. holes complete all as specified and directed. |
| 14 | Supply, installed, jointing and testing in replacement of unserviceable CI wafer type dual plate check valve (suitable for test pressure of PN 1.6)ofsize 100 mm , with flanges, Nut, bolts & washerscomplete all as specified and directed.Notes:- (i) The cost of Earth work, joints & jointing materials of thenon return valve shall be deemed to be included in the quoted rates. |
| 15 | Disconnecting and taking out carefully old unserviceable sluice valve and supply & fixing sluice valve 150 mm dia with stainless steel spindle CI body class I ISI marked PN 1.6 both end flange and drilled and fixed by means of bolts, nuts and washers including providing rubber insertion of suitable thickness for 150mm dia size, complete all as specified and directed. |
| 16 | Disconnecting and taking out carefully old unserviceable sluice valve and supply & fixing sluice valve 100 mm dia with stainless steel spindle CI body class I ISI marked PN 1.6 both end flange and drilled and fixed by means of bolts, nuts and washers including providing rubber insertion of suitable thickness for 100mm dia size, complete all as specified and directed. |
| 17 | Disconnecting and taking out carefully old unserviceable locking arrangemet and supply and fixing locking arrangement along with lock at fire hose box etc complete all as specified and directed. |
| 18 | Supply and fix in repair Gun metal ball valve ISI markedhigh pressure with iron wheel headscrewed both ends for iron pipe line and fixedproperly of 25 mm dia complete all as specified and directed. |
| 19 | Supply, fixing, testing and commissioning of 2 core annealed tinned copper conductor PVC sheathed, flexible, 2 x 1.5 sq mm armoured cable running through Existing Stove enamelled, black Conduit complete in all respect for Hooter, detector, MCP to Fire Alarm Panel complete all as specified and directed. |
| 20 | Supply and fixing in repair/ replacement ofcontrolled percolation fire hose pipe (as per IS:8423) of 63 mm dia and 15 meter length rated for brust pressure of 38 Kg/sqcm, with coupling made out of brass as per bureau of indian standards including takingdown old unserviceable item complete all as specified and directed. |
| 21 | Supply and fixing brand Delivery Hose Coupling, inst. Pattern, Stainless Steel, pair of male & female parts, 63mm x 63mm size bearing ISI marked IS: 903 complete all as specified and directed. |
| 22 | Supply and fixing brand Branch pipe-short, Stainless Steel, SS-304, 63mm male inst. inlet, male threaded outlet, fitted with 15mm (6/12/20/25 /30) bore nozzle, suitable to fit with standard inst. Type 63mm dia. Coupling ISI marked bearing IS: 903 complete all as specified and as directed. |
| 23 | Supply and fixing Binding of RRL Hose Pipe Coupled with Fire Hose delivery Coupling with Copper / S.S. Wire complete all as specified and as directed. |
| 24 | Supply and fixing Compact type first aid hose reel (36 mtr) complete all as specified and as directed. |
| 25 | Supply and fixing First Aid Hose Reel Drum, swinging wall mounting type complete with 6mm gun metal shut-off nozzle, conforming to IS: 884. ISI marked complete all as specified and directed. |
| 26 | Disconnecting and taking out carefully old unserviceable hose box and Supply & fix hose boxpre fabricated weather proof lockable cabinet of size not less than 0.9 x 0.6 x 0.25 mtr made out of MS sheet of 18 gauge thickness having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside with the letters \"FIRE HOSE\" including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade complete all as specified and directed. The cabinet shall be suitableto accommodate 2 nos. or 4 nos15 mtrlongHose pipe & 2 Nos branch pipe nozzle.(Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer). |
| 27 | Supply and fixing FIRE MAN’S AXE with heavy insulated rubber handle tested to 20,000 volts as per IS: 929 complete all as specified and as directed. |
| 28 | Supply and fixing Inlet Breeching, C.I. Body having Two Gunmetal 63mm male instantaneous inlets conf. to IS:904, fitted with non-return valves, flanged outlet 220mm OD, 180mm PCD, eight holes of 19mm dia., complete with gunmetal 25mm size drain-valve, two rubber blank caps and chains complete all as specified and directed. |
| 29 | Supply and fixing Inlet Breeching, C.I. Body, having Three Gunmetal 63mm male instantaneous inlets conf. to IS:903, fitted with non-return valves, flange outlet 220mm OD, 180mm PCD, eight holes of 19mm dia., complete with gunmetal 25mm size drain valve, three rubber blank caps and chains complete all as specified and directed. |
| 30 | Supply and fixing Gun Metal Draw Out Connection 100 mm size complete all as specified and directed. |
| 31 | Supply and fixing of 4 mm plain glass along with Rubber Beating etc change in FHC complete all as specified and directed. |
| 32 | M&L for painting after cleaning old rusted paint by scrapper andapplying two coats of synthetic enamel paint over a coat of primer on existing pipes, Hose pipe box, Hose reel drum, fire points including nut bolt, stand, buckets and marking water flow direction and panel complete all as specified and directed.Note : Colour code shall be as approved by Engr-in charge. |
| 33 | Taking down the existing unsvfire alarm control panel and supply and fixingin repair of2 LoopControl Panel - SITC of Microprocessor based Net-workable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity from 2 loops to 4 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connectedexpansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unitwhich is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. Approved by LPCB complete all as specified and directed. |
| 34 | Supply, fixing and testing inrepair/ replacement ofDetectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with selfinbuilt intelligence as per IS: 11360with suitable fixing arrangements including takingdown old unserviceable item complete all as specified and as directed. |
| 35 | Supply, fixing & testing in replacement manual call point(resettable type) with working voltage 24 volts DC, push button, breakable glass, chain, hammer etc painted with red shade including takingdown old unserviceable item complete all as specified and as directed. |
| 36 | Supply, fixing & testing in repair/ replacementof Addressable loop poweredsounder strobe. Dual tone hooter shall be of electronic type and shall give discontinuous/intermittentaudible alarm automatically when ever smoke detector or heat detector operates. Hooter shall be complete with magnetic coil ( sound coil ) and accessories, ready for mounting ( fixing ) complete all as specified and directed. |
| 37 | Supply, fixing & testingin repair/ replacement of Addressable monitor module which Includes a single output, flying leads for easy installation. Electronically addressed, & Vds complete all as specified and directed. |
| 38 | Supply, fixing, testing& commissioning in replacement of remote response indicators, Response indicators shall be housed in a 16 gauge aluminium casing. It shall glow clearly in case the detector to which it is connected gives an alarm signal. The word FIRE shall be clearly written on the visible face of the box. It shall have two numbers of red LED to compensate for fusing of either LED complete in all respect as specified or indicated including testing on completion. |
| 39 | Supply & fixing in replacement of 6 Watt ceiling Speakercomplete in all respect as specified or indicated including testing on completion complete all as specified and directed. |
| 40 | Supplyfixing, testing & commissioning in replacement/ repair of Beam Master detector with Transmitter and receiver (Add power supply units & Module) Complete in all respect as specified or indicated including testing on completion complete all as specified and directed. |
| 41 | S&F in repair/replacement maint free batteries 12 volt, DC 07 AH complete all as specified and etc complete all as specified and directed. |
| 42 | Opening, and disassembling monoblock CF pump with 1400 RPM, Flow 900 LPM, Head 70 Mtr from electric motorincluding shifting, transportation, overhauling shaft metering, welding , brazing and grinding the shaft and replacing of worn out parts and re-assembling and connecting it to the electric motor complete all as specified and directed.Note : (i) The unit rate shall include for minor spares such as bolts, nuts washers, oil seal, gasket, greasing etc as required.(ii) Major spares as required shall be measured and paid for separately. |
| 43 | Supply & fixingin replacementBall bearing of electric motor upto 12.5 HP capacity complete all as specified and directed. |
| 44 | Supply & fixingin replacement Gun metal bushes of pump upto 12.5 HP capacity complete all as specified and directed. |
| 45 | Supply & fixingin replacement MS couplingof pump upto 12.5 HP complete all as specified and directed. |
| 46 | Repair and Servicing of diesel driven fire pump set centrifugal type of head 70 mtr, delivery 2280 LPM, Pressure 3.5 kg/sqcm cleaning of pump outer filling of grease in pump, rectification of alignment of pump and motor, changing of gland packing, bushes and gasket complete all as specified and directed |
| 47 | Supply only Fuel filter element pre for above item No 46 complete all as specified and directed. |
| 48 | Supply only Fuel filter element micro for above item No 46 complete all as specified and directed. |
| 49 | Supply only Lubricating oil filter for above item No 46 complete all as specified and directed. |
| 50 | Supply only Main element for air cleaner for above item no 46 complete all as specified and directed. |
| 51 | Supply only Engine Oil for above item no 46 complete all as specified and directed. |
| 52 | Supply only coolent for above item no 46 complete all as specified and directed. |
| 53 | S & F in replacement MCCB 4 Pole 125A, Adjustable type breaking capacity ICU at 415 (50KA) complete all as specified and directed. |
| 54 | S & F in replacement MCCB 4 Pole 630A, Adjustable type breaking capacity ICU at 415 (50KA) complete all as specified and directed. |
| 55 | Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5mtr in depth and getting out in soft/loose soil for taking out U/S clogged water pipe lines & relaying after cleaning /laying of new pipe lines, complete all as specified and directed. |
| 56 | Returning filling in, including spreading, leveling, watering and well ramming in layers n exc 25 cm thick in soft/loose soil complete all as specified and directed. |
| 57 | Removing surplus excavated soil n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and directed. |
| 58 | M&L cutting PCC/floor/road and taking out pipes and making good, with material as per existing after laying of pipe for including Cement concrete work in pavement/ hard-standing of flexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or lessall as specified and directed size of trench not more than 0.30 x 0.60 cm complete all as specified and directed. |