| Sl. No. | Item Description |
| 1 | Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each complete all secified and as directed. |
| 2 | Taking down chowkat with shutter (without taking off shutter from the frame) exc 1.5 Sqm n.exc 4 Sqm each complete all as specified and as directed. |
| 3 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, as per specification complete all as specified and as directed. |
| 4 | S&F Factory made solid panel pvc doorshutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined to-gether with solvent cement as per specification complete all secified and as directed. |
| 5 | S&F 125x60mm pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 6 | S&F 2nd class hardwood plain,solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. |
| 7 | M&L PCC type BO, 1:2:4 (using 12.5mm graded crushed stone aggregate) as in filling of hollow pressed steeldoor framecomplete all secified and as directed. |
| 8 | S&F Factory made solid wire gauzed i.e. panel will be of wire gauze pvc doorshutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Single Side Prelam PVC sheet for top rail, lock rail & bottom rail on either side having one side feathered edge and on other side 10mm 900 bent edge & as gap insert for top rail & bottom rail; i.e. panel will be of wire gauze. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly complete all secified and as directed. |
| 9 | S&F of 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 10 | Dismantling boarding, any description, fixed in any position with nails or screw complete all as specified and as directed. |
| 11 | S&F 25 mm thick Prelaminated particle board, exterior grade, for shutters of cupboard/cabinets and like prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to hinges to timber frame work and other location including decorative beadings on door frames complete all as specified and as directed. |
| 12 | S&F 18/19 mm thick Prelaminated particle board, interior grade, for shelves and partitions of cupboard/cabinets and like, prelaminated one side with decorative choice lamination & otherside balancing white lamination, fixed with screws to timber frame work including decorative lipping complete all as specified and as directed. |
| 13 | S&F 6 mm thick Teak wood lipping fixed on all external edges of cupboard shutter, shelves & partition 25 mm thick with combination of nails and fevicolcomplete all as specified and as directed |
| 14 | S & F 30mm width of flaps Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all secified and as directed. |
| 15 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finishedcomplete all secified and as directed. |
| 16 | M&L for preparing new wooden surfaces of any description, not otherwise described over 10cm width or girth and applyingtwo coats of synthetic enamel paint over pink primer complete all as specified and as directed |
| 17 | S&F 140 mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door complete all as specified and as directed |
| 18 | S&F 32mm bore mild steel Chromium plated curtain rodwith 02 Nos decorative ball type brackets (for each opening) and 02 Nos decorative side stoppers/holders (for each opening) fixed on wall with wooden gutties & screws complete all as specified and as directed |
| 19 | S&F Aluminium ( extruded section) door closer hydraucally regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight bettween 61 to 80 kg and fixed, complete all as specified and as directed |
| 20 | S&F Aluminium, anodised, barrel tower bolts of extruded section of 150 mm long complete all as specified and as directed. |
| 21 | S&F 75 mm aluminium anodised hasp and staple, safety type and fixed with screwscomplete all as specified and as directed |
| 22 | S&F Aluminium handles, cast type, anodised of 150 mm size complete all as specified and as directed. |
| 23 | S&F 100 mm long , Butt hinges, extruded aluminiumalloy with galvanised mild steel hinge pin, anodised and fixed, typeB-21 complete all as specified and as directed. |
| 24 | S&F 250 mm Mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple and fixed complete all as specified and as directed. |
| 25 | S&F Powder coated aluminium frame for doors, windows ventilators and partition with one or more rebates including joining cleat for fixing etc. (minimum thickness of powder coating 50 micron) complete all as specified and directed complete all as specified and as directed. |
| 26 | S&F Powder coated Anodised aluminium for windows/ventilators of side hung/top hung shutters or fixed partition, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, tower bolts 02 Nos, handles 02 Nos in each shutter, hinges, anodised aluminum snap beading screws etc. including provision for cooler/AC/exshaust fan opening as per neccesary direction and complete all as specified and as directed. Note :(i) Glass panes and wire cloth shall be measured & paid separately . (ii) Rubber beading will not be weighed and not to be paid seperately. |
| 27 | S & F Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Stainless steel wire staples complete all as specified and as directed. |
| 28 | S&F Sheet glass 6.3 mm thickselected quality, in squaresexc. 0.5 sq. m each pane fixed in aluminium doors/ window and partitions including jointing cleats, glazing clips, rubber packing, anodised snap beading, screws etc complete all secified and as directed. |
| 29 | S & F 3 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and as directed. |
| 30 | S&F for GI frame work for ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centreto centre with GI Cleat and steel expansion fasteners with and including ceiling section ( not exc. 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed tothe intermediate channel with connecting clips acrośs the intermediate channelat 45mm ceṇtre including 4mm thick non asbestos fibre cement building E boards fixed or laid/inserted toGI framework with screws for fixing in 600 mm x 600 mm grid, complete all as specified and as directed. |
| 31 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m complete all as specified and as directed |
| 32 | M & L for brick work with sub-class ‘B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) complete all secified and as directed. |
| 33 | M&L for brick work with sub class \"B\" bricks straight or curved on plan to any radius, built in CM 1:4as in half brick thick wall including provision of 02 Nos 8mm TMT bars at every fourth course complete all as specified and as directed. |
| 34 | Demolition of reinforced cement concrete (RCC) in parapet walls, cupboard shelves & walls, RCC water tank and washbasin platform etc or RCC in any description and in any position (reinforcement cut as required to facilitate demolition) for complete all as specified and as directed. |
| 35 | M & L for mild steel TMT bars 10 mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed. |
| 36 | Use and waste of formwork to rough finished flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all secified and as directed. |
| 37 | M & L for reinforced cement concrete (1:2:4), type B-0 (using 12.5 mm graded stone aggregate) slabs supported on walls, beams and column in floors, roofs, landings, balcanies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 38 | M & L for precast reinforced cement concrete (1:2:4), type B-1 (using 20 mm graded stone aggregate) as in man holes cover slab or similar articles with plain faces and set in cement mortar (1:4) complete all as specified and as directed. |
| 39 | Taking down cement plaster on brickor concrete surfaces incl racking out joints hacking for key scrubbing downwith water etc complete all as specified and as directed. |
| 40 | Chipping of loose/ damaged / cracked / previously repaired/ delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor Note: The execution shall be carried out at height varying from ground floor to Ist floor up to roof level approx up to 7 mtr especialy for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scafolding and ladder complete all as specifiedand asdirected. |
| 41 | M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height up to 3rd floor levels, includingfinishingof applied Polymer mortar as per the technical specifications and manufacturer\"s instructions Note: The execution shall be carried out at height varying from ground floor to Ist floor up to roof level approx up to 7 mtr especialy for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scafolding and ladder complete all as specifiedand asdirected. |
| 42 | M&L for weld-mesh of size 50x50x3mm to be wrapped on the exposed surface of rib of beam, on the slab bottometc and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture Sika Plasto creat plus or equivalent make in Fosroc / Themax as per manufacturer\"s instructions as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. The gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer\"s instructions and directionNote: The execution shall be carried out at height varying from ground floor to Ist floor up to roof level approx up to 7 mtr especialy for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scafolding and ladder complete all as specifiedand asdirected. |
| 43 | Providing and fixing water tight centering & shuttering and Scaffolding including bolting, strutting, propping etc.Including removal of form work from column, beam, slab and chajja etc. complete as per site requirement and directionsNote: the execution shall be carried out at height varying from ground floor to Ist floor up to roof level approx up to 7 mtr especialy for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scafolding and ladder complete all as specifiedand asdirected. |
| 44 | Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product : SikaRep Microcrete-4 + adequate coarse aggregate, Yield:approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep Microcrete-4 or equivalent make in Fosroc/Thermax as approved by GE.Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99Note: The execution shall be carried out at height varying from ground floor to Ist floor up to roof level approx up to 7 mtr especialy for external surfaces of walls over/under sunshade/projection of roof/window and like and also inside the walls of utility shaft portion by using necessary scafolding and ladder complete all as specifiedand asdirected. |
| 45 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all secified and as directed.. (Note : WPC shall be measured and paid separately against respective item). |
| 46 | Supply only liquid water proofing compound. |
| 47 | M & L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all secified and as directed. |
| 48 | M&L 15 mm thick rendering in CM 1:6 on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 49 | M&L for applying two coats of distemper oil emulsion over a coat of primer over 3mm wall care putty on newly plastered wall surfaces including preparation of surfaces complete all secified and as directed. |
| 50 | M&L 10 mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surfaces, rendering finished even and smooth (without using cement) as in ceilings of rooms/under projected portion of RCC roof slab/ chajjha of windows and doors or similiar work complete all as specified and as directed. |
| 51 | M & L for preparing newly plastered surfaces ceiling and applying three coats of white wash complete all secified and as directed. |
| 52 | M & L for preparing newly plastered surfaces walls and applying three coats of white wash complete all secified and as directed. |
| 53 | M & L for Complete removal of existing treatment of any type from walls and applying 3mm thick wall care putty on walls to obtain a smooth surface including making good any undulations on the surfaces complete all secified and as directed. |
| 54 | M & L for preparing newly applied surface of wall care putty on walls bysand paper , remove spots etc. and applying Two coat of distemper oil emulsion complete all secified and as directed. |
| 55 | M & L for preparing old decorated surface of wall/chajja by brooming down or by steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and applying two coat of cement base paint on surface of wall/chajja complete all secified and as directed. |
| 56 | M&L two coat of white washing on old plastered surfacesof ceiling including preparation of surfaces complete all as specified and as directed. |
| 57 | M&L for complete removal of existing treatment from walls sufaces and two coat of white wash over a coat of chalk whiting primer complete all as specified and as directed. |
| 58 | M&L for treatment of sunken floor slab comprising of the following specifications with and including demolitionof PCC in sunken portion/ floors including removal of the debris outside the MOD land andcomplete all secified and as directed.(i) Demolition of PCCin sunken portion /floors and Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including S& f in repair 40 mm dia , 450 mm long medium grade spout pipeand cutting holes in bricks or RCC wall for the same complete all secified and as directed. (i) Rendering of uneven surfaces atbottom and sides up to floor level with 15 mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in list of makes as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seppage and where dampness / seppage is noticed, nozzles shall be fixed and grouting carried out. (ii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in list of makes as approved by GE. (iii) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (iv) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in list of makes as approved by GE in two coats @ 3kg/sqm to sanwiched with glass fibre reinforcemnt: Sika Fab-1or or equivalent make in list of makes as approved by GE over base coat as per mnaufacturer\"s instruction to bottom and vertical sides up to finished floor level+100mm height.The thickness of two layer shall be 1mm.When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion.(v) Allpipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. (vi)The sunken floor shall be filled with lean concrete 1:5:10, type E2 (40 mm graded aggregate) Note : Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunkenslab shall be maintained.The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all M&L is included in the rates quoted above. |
| 59 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 60 | M & L 15 mm thick in cement mortar 1:4 screed bed or bedding layer of mortar for laying floor finishes complete all secified and as directed. |
| 61 | M&L for non skid ceramic jointless tiles (coloured) 1st quality, 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over complete all as specified and as directed. |
| 62 | M & L rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces as in vertical surfaces for receiving tiles complete all secified and as directed. |
| 63 | M&L for glazed ceramic tiles (coloured) 1st quality, 450X 350X 7mm / 300mm x 450mm x 7mm thick , on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid overcomplete all as specified and as directed. |
| 64 | M & L 18 to 20mm thick green marble (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 65 | Taking down 20mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work complete all as specified and as directed. |
| 66 | S & F 20 mm bore Galvanized Steel tubes, medium grade with all fittings and connection complete for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all secified and as directed. |
| 67 | Taking down 15mm bore steel/ composite/ CPVC water tubing and connection from any position wall /ceiling surfaces or concealed including cleaning for re-fixing or removing from site of work complete all as specified and as directed. |
| 68 | S&F 3- layer PP-R Polypropylene random copolymer) 20mm outer dia concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded fittings polypropylene laid concealed in floor/wall/ceiling complete all secified and as directed.Note : Work will be done under authorised/concerned company\"s supervision. |
| 69 | S&F in repair gun metal globe gate valve 20 mm bore complete all secified and complete all secified and as directed. |
| 70 | S&FRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I (1000 ltr capacity) including 20mm Nipple suitable for HDPE water tank and Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed to 20 mm bore pipe.(Make :- \"Sintex\") inculding dismantling of oldwater Tank complete all as specified and as directed. |
| 71 | M&L for providing PCC 1:2:4 type B-0 ( using 20mm graded stone aggregate) with maintain the proper roof slope as in bedding, coping and kerb including preparing old surfaces complete all secified and as directed. |
| 72 | 10 mm thick plastering in cement mortar 1:3 mixed with water proofing compound (to be measured seperately) to the roof surface as per manufacturer instructions finished even & smooth complete all secified and as directed. |
| 73 | Supply and apply acrylic based waterproofing and heal reflecting system having following key performance properties complete all secified and as directed.:1. Acrylic polymer dispersion single component liquid applied system.2. Fully reinforced with glass fiber reinforced sika Fab or Equivalent The installation company of roofing system should be trained and authorized by Manufacturer & installation to be carried out as per manufactures approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacture as a part of system. Any component used which is not manufacturer by the roofing manufacturer can only be used with official approval from manufacturer.Application system as sub serial no (a) to (e) as below :-(a) Providing and Applying Primer Coat primer over the prepared surface with Sika® CoolCoatPrimer or Equivalent Consumption @0.2-0.3 kg/m²(b) First coat: sika coolcoat or or Equivalent / Consumption @ 0.75 kg/m²(c) Fiber Reinforcement Make Sika or Equivalent(d)Second coat: sika coolcoat or Equivalent / Consumption @ 0.75 kg/m³(e) Top Coat Sika® CoolCoat Primer or Equivalent Consumption @0.05-0.08 kg/m² |
| 74 | Demolition and breaking of internal dia of pipe 100 mm bore / 75 mm bore pipes of Salt glazed ware, AC or Reinforced concrete set in cement mortar complete all secified and as directed. |
| 75 | S & F 110 mm dia PVC (SWR) pipes,single sockets, in any length with sealant rubber ring joints fixed to wall or in floors and in trenches incl necessary MS flat iron clamps of size (40x4mm) complete all as specified and as directed. |
| 76 | S & F 110 mm dia PVC (SWR) pipes,single sockets, in any length with sealant rubber ring joints in floors and in trenches complete all as specified and as directed. |
| 77 | S&F 100mm bore UPVC SCH - 8 grading pipes as in soil, waste and vent pipes in any length with or without ears, with cement joints incl all fittings, laid in trenches or in floors from Gully trap (GT) up to Ist man holes complete all as specified and as directed |
| 78 | S&Fin repair of 110 mm bore, PVC (SWR) bends of any radius complete all secified and as directed. |
| 79 | S&F in repair PVC (SWR) junction, single, (single T) equal or unequal 110mm bore complete all secified and as directed. |
| 80 | S&F 75mm dia, PVC (SWR) pipes, single socketed, in any length with sealant rubber ring joints fixed to walls including necessary nails, plugs and holder bats etc complete all as specified and as directed |
| 81 | S&F 75mm dia, PVC (SWR) pipes, single socketed, in any length with sealant rubber ring joints in floors and in trenches complete all as specified and as directed. |
| 82 | S&F in repair 75 mm bore, PVC (SWR) bends provided with access door of any radius complete all secified and as directed. |
| 83 | S&Fin repair 75 mm bore PVC (SWR) junction, single, (single T) equal or unequal complete all secified and as directed. |
| 84 | M&L 75 to 100mm diaPVC (SWR) floor trap, plain with grating including jointing with solvent cement as in repairs complete all secified and as directed. |
| 85 | M&L for PVC(SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all secified and as directed. |
| 86 | S & F CP grating 75 to 100 mm dia in repair with or without hole as directed by Engr-in-Charge complete all as specified and directed. |
| 87 | S & F in repairVitreous china wash down water closet (Pedestal), white (EWC) including Plastic seat of same colour of WC, closed patttern with flat bottom, and seat cover with Mild steel chromium plated hinging device complete all secified and as directed. |
| 88 | S& Fin repair 15 mm CP 2-in-1 stop cock/bib tap fancy type for fixing of health faucet or jet spray for the WC and complete all secified and as directed. |
| 89 | S& Fin repair Brass SS Jet Spray with 1 m pvc tube and ccomplete all secified and as directed. |
| 90 | S&F in repairs health faucet 15mm bore with 1.0 m tube & hook (Braded tube) complete all as specified and as directed |
| 91 | S&F in repairs, 10 litres capacity PVC valveless syphonic action type, flushing cistern (ISI marked), low level with inlet, ball valve, float bracket & flush pipe complete all secified and as directed. |
| 92 | S & F in repair Vitreous China wash basin, white, flat back, size 630 x 450mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all secified and as directed. |
| 93 | S& F in repair 32 mm waste fitting, brass, chromium plated for glazed ware sinks, basins, etc. with long scewed shanks and fly-nuts, flange end bedded in read lead cement and other end fixed complete all secified and as directed. |
| 94 | S&F 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all secified and as directed. |
| 95 | S&F 32mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm sq fixed complete for WHB waste water drain to walls,ceilings or in floors etc., including cutting chases, pinning for concealed water tubing and making good, cutting not exc 10 cm girth complete all secified and as directed. |
| 96 | S&F 32mm Bottle trap of PTMT for WHB/Kitchen sink etc.. having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms)complete all secified and as directed. |
| 97 | S&F CP Central Hole Basin Mixer with ‘U’ shape Round Casted Spout with 450 mm Long Braided Hoses in lieu of old u/s pillar tap complete all secified and as directed. |
| 98 | S&F only 600mm x 450mm bevelled edge mirror of sellected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all secified and as directed. |
| 99 | S&Fin repair sheet glass shelf assembly consisting of 5.5mm thick sheet shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all secified and as directed. |
| 100 | S&F in repair 15 mm fancy type, chromium plated with long shank and cup (concealed type) Stop valves, cast copper alloy, screwed down, high pressure screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 101 | S&F in repair brass chromium plated shower roses of size 125mm with or without swivel joints, any size, including shower arm 15mm size, 195mm long bend of 45degree with flange of CP fixing to steel pipe or union complete all secified and as directed. |
| 102 | S&F CP soap dishfixed to plugs with chromium plated brass screws complete all secified and as directed. |
| 103 | S&F corner glass shelf 300mm (with brass brackets) complete all secified and as directed. |
| 104 | S&F in repair Brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all secified and as directed. |
| 105 | S&FSS , premium type , peg set 6.heavy weight complete all secified and as directed. |
| 106 | S&F 15mm bore dia brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed in lieu of old u/s bib taps complete all secified and as directed. |
| 107 | S & F in repairs 15 mm bore chromium plated fancy type bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrulecomplete all secified and as directed. |
| 108 | S&F in repair 15 mm Stop valves/angle stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all secified and as directed. |
| 109 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 110 | S&F of steel work in tubular trusses and tubular post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st-240 including one shop coat of zinc chromate primer paint including preparation of surface complete all secified and as directed. |
| 111 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 112 | M&L preparation of new steel or Iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 113 | M&L one coat of synthetic enamel paint (1st grade quality) to old decorated steel surfaces of girth exc 10cm including preparation of surfaces complete all secified and as directed. |
| 114 | S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all secified and as directed. |
| 115 | S&F of pre painted galvatume aluminium zink coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all secified and as directed. |
| 116 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided complete all secified and as directed. |
| 117 | M & L 75 mm thick plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement complete all secified and as directed. |
| 118 | M&L broken stone or boulders for hard core of guage n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all secified and as directed. |
| 119 | M&L for 75 mm thick cement concrete type D2, 1:4:8 using 40mm graded stone aggregates as sub base to floor, complete all secified and as directed. |
| 120 | M&L forSand filling under floors or in foundations including watering and consolidation ccomplete all secified and as directed. |
| 121 | M&L for Machine pressed precast conctete coloured interlocking paver block any shape and size fixed with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 grade ccomplete all secified and as directed. |
| 122 | M&L PCC type C1, 1:3:6 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, hold fast blocks, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all secified and as directed. |
| 123 | M&L for Machine cut (Mirror Polished) kota stone slab flooring 18-20mm thick of size not less than 0.30 Sqm of each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including 15mm thick screed bed or bedding in cement mortar 1:6 complete all secified and as directed. (Note : Single piece tiles will be placed on the surface of stair case tread area). |
| 124 | M&L for Kota stone slab 15mm thick in riser of bricks steps & riser of staircase , skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in 10mm thick CM (1:3) to receive Kota Stone complete all as specified and directed (Note : Single piece tiles will be placed on the surface of stair case riser area). |
| 125 | Labour only for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situationsomplete all as specified and as directed. |
| 126 | Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduitwith switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed. |
| 127 | M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etcincluding modular press steel with cover plate and frame, complete, all as specified & directed. |
| 128 | All as per item No. 128 (here-in-before)but one Fan/exhaust fan pointcontrolled by one Number one way switch complete all as specified and directed |
| 129 | All as per item No. 128 (here-in-before)but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board. |
| 130 | All as per item No. 128 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board. |
| 131 | AllaspersrlitemNo.128(here-in-before) but for 15 Amp socket out let by using 2.50 sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent boardincluding provn of2.50 Sqmm unsheathed, multi strandedcopper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed. |
| 132 | S&Fmodular type switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed. |
| 133 | S&F modular typeswitch piano flush type, single pole, one way, 15 Amp, 230 Volts. |
| 134 | S&F modulartype socket outletmultipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed. |
| 135 | S&F modulartype socket outletmultipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed. |
| 136 | S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminalswith back plate etc complete all as specified and directed. |
| 137 | S&F in repair of modular type ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed. |
| 138 | S&F LED light fitting 1x40W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. |
| 139 | S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed. |
| 140 | S&F in repair of street light LED light fitting 35 watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. |
| 141 | S&F in repair of MCB single pole, 240 volts, 10 Amps to 32 Amp breaking capacity 10KA complete all as specified and directed. |
| 142 | S&F in repair of M.C.B. SPN, 240 Volts, 40-63 Ampsbreaking capacity 10 KA complete all as specified and directed. |
| 143 | S&F in repair of M.C.B. TPN, 240 Volts,100 Ampsbreaking capacity 10 KA complete all as specified and directed. |
| 144 | S&F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp IP protection 43 having door earthing complete all as specified and directed. |
| 145 | S&F in repair of sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 146 | S&F in repair of sheet metal enclosure MCB DB SPN 6 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 147 | S&F in repair of sheet metal enclosure distribution boardTPN 4 way double door powder coated, protection class IP-42, suitable for mounting MCB,DBs confirming to IS-13032,IS-8632, BS-5484 with min200 amps rating copper bus bar, complete all as specified and directed. |
| 148 | S&F in repair of sheet metal enclosure distribution boardTPN 6 way double door powder coated, protection class IP-42, suitable for mounting MCB,DBs confirming to IS-13032,IS-8632, BS-5484 with min200 amps rating copper bus bar, complete all as specified and directed. |
| 149 | S&F sub main wiring using two single core 10 sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing PVC conduit (as required & directed by Engr-in-Charge) accessories like bends, tee, etc. and connecting to earth dolly and including 4.0 sqmm earth wire, PVC insulated & unsheathed all as directed. |
| 150 | S&F sub main wiring using two single core 4 sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing PVC conduit (as required & directed by Engr-in-Charge) accessories like bends, tee, etc. and connecting to earth dolly and including 6.0 sqmm earth wire, PVC insulated & unsheathed all as directed. |
| 151 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I) including taking out old existing earthing complete all as directed. |
| 152 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades including regulator and deposit to MES store yard of AGE E/M GE Hisar Complete all as specified and as directed |
| 153 | Supply and fixing ceiling fans (Copper winding) complete with blades, down rods and accessories, 230V, 1200mm sweep , min air delivery 210 CFM ,BEE five star rated with brushless direct current motor(BLDC)with remote complete all as specified and directed |
| 154 | Supplying, laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 50 sqmm 3.5 core all as specified and directed.(Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc complete all as specified and directed by Engr-in- Charge. |
| 155 | Excavation in trenches in soft/loose/hard/dense soil n exc 1.50 meter wide and n exc 1.50 meter in depth for foundation of pole,laying cable etc and getting out etc complete all as specified and directed. |
| 156 | Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick etc complete all as specified and directed. |
| 157 | Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point etc complete all as specified and directe. |
| 158 | Supplyand laying double wall corrugated pipe(DWC) confirming to IS 16098 Part -2 of size 50mm outer dia and 38mm inner dia complete all as specified and as directed |
| 159 | S&F down rod suitable for ceiling fans for extension from ceiling of 1meter length complete all as specified and directed by Engr-in- Charge. |
| 160 | Supply and fixing testing metal body exhaust fan of 380 mm sweep heavy duty, double ball bearing 900 RPM, suitable for SP 230/ 250 volt 50 HZ AC Supply) complete with louver shutter including fixing/ grouting of frame in wall & cutting opening complete with covers & connecting with & including 3 Nos 1.5 Sqmm single core, PVC insulated but unsheathed FRLS 1100 Volts grade cable with multi stranded copper conductor from ceiling rose to fan complete Make : Mode No Turbojet SP of Havells or Cat Part No Supreme DLX HD of Bajaj or Cat No Transair of Crompton or equivalent in list of makes. |
| 161 | Taking down hot water geyser of any capacity after disconnecting all necessary electrical/ mechanical connections from MCB Box/ Switch Board/ Wall Nut & Bolts and deposit to MES store yard of AGE E/M GE Hisar complete all as specified and as directed |
| 162 | Supply and fix electric water heater, storage type mild steel body with glass lined coating (Outer Body) with Titanium armour technologyinner tank coating for preventing corrison rusting and heatingelement upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy