| 1 | S & F aluminium Anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed by the Engr-in-Charge. |
| 2 | M & L forProviding and fixing Gypsum Board, 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed. |
| 3 | M & L for Preparation of internal ceiling surface of any description and applying two coats of oil bound distemper emulsion over a coat of primer and over one or more coats of wall care putty to a smooth surfacecomplete all as specified and directed. |
| 4 | M&L for preparation of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping etc and applyingtwo coats of oil bound washable distemper over a coat ofprimer including applying one or more coat of wall care putty to get a smooth surface including making good any undulations on the surfacescomplete all as specified and as directed.Note :- (i) Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS(ii) Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer) |
| 5 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc except light fitting. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 6 | Taking down unserviceable main switches, DBs, bus bars chambers any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 7 | Taking down unserviceable sub-main wiring (any numbers of cable) withrigid steelconduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. |
| 8 | M & L for conceledPoint wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type includingmetal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed,for one light/exhaust fan/fan point/call bellcontrolled by one way switch.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 9 | All as per item No.8 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 10 | All as per item No.8 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 11 | All as per item No.8 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLSH (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLSH (ISI marked) as earth lead complete ditto |
| 12 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI / PVC boxes of suitable module including modular white cover plate of suitable module for fixing modular type switchesincluding provision of multistranded 1.5 Sq.mm copper conductorcable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bellcontrolled by one way switch complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 13 | All as per item No.12 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 14 | All as per item No.12 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 15 | All as per item No. 12 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLSH (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLSH (ISI marked) as earth lead complete ditto |
| 16 | All as per item No.12 here in before but for one 15 Amps power point on the independent board for one geyser with two runs of PVC insulated and unsheathed copper conductor cable of size 4.00 sqmm multistrandedFRLSH (ISI marked) and 4.00 sqmm PVC insulated unsheathed solid copper conductor cableFRLSH (ISI marked) as earth lead complete ditto |
| 17 | S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. |
| 18 | S & F Modular socket outlet6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. |
| 19 | S & F Modular socket outlet6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. |
| 20 | S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed. |
| 21 | S & F steped type modular fan regulator ,100/120 W 2 module complete all as specified and as directed. |
| 22 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/ polycarbonate, insolated body complete all as specified and directed. |
| 23 | M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and includingconcealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cableas earth continuity conductor complete all as specified and as directed.(Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 24 | M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and includingconcealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cableas earth continuity conductor complete all as specified and as directed.(Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 25 | M & L for Sub main wiring with 2 runs of Single core 4.00 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and includingconcealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4.00 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cableas earth continuity conductor complete all as specified and as directed.(Note :- (i) Two runs of 4.00 sqmm and one runs of 4.00 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 26 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and includingconcealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cableas earth continuity conductor complete all as specified and as directed.(Note :- (i) Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 27 | M & L for Sub main wiring with 4 runs of Single core 6.00 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and includingconcealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6.00 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cableas earth continuity conductor complete all as specified and as directed.(Note :- (i) Four runs of 6.00 sqmm and one runs of 6.00 sqmm cable as earth wire and one run of conduitshall be measured as one length,(ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 28 | M & L for Sub main wiring with 4 runs of Single core 16.00 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and includingconcealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 16.00 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cableas earth continuity conductor complete all as specified and as directed.(Note :- (i) Four runs of 16.00 sqmm and one runs of 16.00 sqmm cable as earth wire and one run of conduitshall be measured as one length,(ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 29 | M & L for Sub main wiring with 4 runs of Single core 10.00 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and includingconcealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 10.00 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cableas earth continuity conductor complete all as specified and as directed.(Note :- (i) Four runs of 10.00 sqmm and one runs of 10.00 sqmm cable as earth wire and one run of conduitshall be measured as one length,(ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 30 | S & F powder coated sheet steel Distribution Board, TPN 8 Way, vertical , 415V, Double door with IP 43protection, IK 09 complete all as specified and as directed. |
| 31 | S & F Distribution Board, TPN 8 Way, 415V, Double door with IP 43protection, IK 09 complete all as specified and as directed. |
| 32 | S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43protection, IK 09 complete all as specified and as directed. |
| 33 | S & F sheetmetal MCB encloser2 way with 200 amps rated bus bar complete all as specified and as directed. |
| 34 | S & F powder coated sheet steel Distribution Board, TPN 6 Way, vertical , 415V, Double door with IP 43protection, IK 09 complete all as specified and as directed. |
| 35 | S & F Vertical TPN DB double door for provision for four pole MCCB upto 160Aincommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer\"s) |
| 36 | S & F sheetmetal four poleMCB encloserwith and including one four pole MCB of capacity 32 Amps 415 Volt complete all as specified and as directed. |
| 37 | S & F Distribution Board,SPN, 8 way, 415V, Doubledoor with IP 43 protection and 200 amps rated bas bar complete all as specified and as diretcedcomplete all as specified and directed. |
| 38 | S & F Distribution Board,SPN, 12 way, 415V, Doubledoor with IP 43 protection and 200 amps rated bas bar complete all as specified and as diretcedcomplete all as specified and directed. |
| 39 | Supply, fixing, commissioning and testing MCB TPN 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed |
| 40 | Supply, fixing, commissioning and testing MCB TP 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed |
| 41 | Supply, fixing, commissioning and testing MCB SPN 40-63Amps, 240 Volts,10KA, C Curve complete all as specified and as directed |
| 42 | Supply, fixing, commissioning and testing MCB SPN 6 to 32 Amps, 240 Volts,10KA, C curve complete all as specified and as directed |
| 43 | Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed |
| 44 | Supply, fixing, commissioning and testing MCB four pole 20 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed |
| 45 | S & F MCCB 415 Volt, 16 KA, 4 Pole, 160 Amps Capacity with fixed thermal magnetic protection unit complete all as specified and as directed. |
| 46 | S & F MCCB 415 Volt, 16 KA, 4 Pole, 63 Amps Capacity with fixed thermal magnetic protection unit complete all as specified and as directed. |
| 47 | S & F energy efficent, BEE 5 star rating, low noice, wall mountedosciliating fan 450 mm sweep,1350 rpm, AC, single phase 240 Volts, 50 Hz, copper wound , aluminium blades, approved colour,over load protectionwith smooth neck tilting provisioncomplete with all accessories and electric connection complete all as specified and directed |
| 48 | S & F in repair LED tube light fittings ultra-slim economical LED Battens in Extruded PC housing and Square shaped diffuser, 1x20 Watt,220 V,AC and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. |
| 49 | S & F in repairs LED downlight, Recess mounted round, die cast aluminium housing, 15 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specifiedand directed. |
| 50 | S & F in repairs LED downlight, Recess mounted round, die cast aluminium housing, 18 Watt as per the existing cutout, 200-275mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specifiedand directed. |
| 51 | Supply and fixingLED tubelight fitting 4 ft long ,40 watt ,230 volt AC, surface mounting, CRCA housing battens equipped with specially designed extruded aluminium heat sink, milky white PC diffuser and elegantly designed white colored ABS endcapscomplete all as specified and directed.Make : Havells cat no STOUTMINI1200BSGEN40 WLED857SPCWH or equivalent model of make as per list of manufacturer mentioned in PS |
| 52 | M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth lead of 4.00mm dia by means of bolts, nuts,check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect all as shown in electrical plate No. 3 and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion including taking down old onecomplete all as specified and as directed by the Engineer-in-Charge.Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost |
| 53 | S&F in repairs 4mm dia galvanised iron or steel wire Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all specified and directed. |
| 54 | S&F Socket Residual Current Device (SRCD) With Steel Enclosure two pin and earth plug including 20 Amps MCB SP complete all as specified and as directed |
| 55 | Supply and fixing in repair LED Ceiling light fitting 35/36 watt recess type flat panel 600x600 mm fabricated CRCA sheet housing duly powder coated with high efficient LED`s & glare free high efficiancy PMMA diffuser complete with driver, holders & LED lamp and all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specifide and directed. |
| 56 | S & F RCBOs,A Type for ensuring protection from leakage current, short circuit & over load protection 63 Amps ,4 pole, 100 mA , 240 V/415 V, 50 Hz, with 10 kA short circuit capacity conforms to IS 12640-2 & IEC 61009-1 complete all as specified and as directed . |
| 57 | S&FUPVC cable trunking casing and capping of size 50x50 mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed. |
| 58 | S & F20 mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, complete all as specified and as directed. |
| 59 | Taking down the ceiling fan of any size/sweep/make from existing position dismantling blades ,spare parts for cleaning,servicing,oiling and lubricating etc including preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with fillerand marking same MES No. with parmanent marker, refixing the blades and re-hanging the fan in its original position,connecting up etc complete all as directed. |
| 60 | S & FLED outdoor Flood light fittings, 100 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specifiedand directed. |
| 61 | S&F LED building security /street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in triple optics complete with IP 66 protection with and including 1.5 sqmm weather proof 3 core FRLH grade copper conductor and 32 mm dia( or higher size as per manufacturers recommendation)light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr longcomplete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primerand including taking up old light fitting complete all as specified and as directedcomplete all as specified and directed |
| 62 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testingcomplete all as specified and directed. |
| 63 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4.0 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out old cable complete all as specified and directed. |
| 64 | Supply, installation and testing ofTower AC indoor and outdoor unit,4.00 TR capacity , three phase, 415 volt,50 Hz, 100% copper, High energy efficient Dual Rotary Compressor ,inbuilt air ioniser and plama filter with cordless remote control complete all as specified and directed. Make: Blue Star, Voltas, Hitachi.O-General,Daikin, Samsung, LG,Carrier, LLOYD |
| 65 | S&F copper pipe line heavy duty 5/8\" diawith flair nuts and insulation as sunction/ discharge pipe of Tower AC complete all as specified and directed. |
| 66 | All as per item no 65 but 7/8\" dia copper pipe complete all as specified and directed. |
| 67 | S & F MS stand for mounting outdoor unit of Acs of capacity 3 ton complete all as specified and as directed. |
| 68 | S & F Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 4 sqmm complete all as specified and as directed. |
| 69 | S & FUPVC cable trunking casing and capping of size 45x45 mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed. |