| 1 | M&L for Point Wiring using approved colour coding as per IS with Zerohalogen flame reretardent (ZHFR) smoke free non toxic non corrosive with copper cable 1.5 sqmm (nominal area) single core insulated and unsheathed stranded cable 1100 Volts grade and including (ERW) stove enamelled concealed conduit heavy duty ISI marked complete all as specified and directed for one light point controlled by one way switch complete all as specified and directed.Note:- (i) Rate of cutting chasing,Pinning in & making good shall quoted in unit rates. |
| 2 | All as per BOQ srl item No.01 here-in-before but with 2.5 Sqmm for power socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L for submain wiring alongwith earth wire with 3 x 2.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including ERW stove enamelled Steel Conduit heavy duty ISI marked and its all accessories of suitable size concealed complete all as specified and directed by Engr-in-Charge.Note: Three runs of 2.5 Sqmm copper cable and one run of above steel conduit shall be measured as one unit length. |
| 4 | S&F LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 5 | S&F flame proof, heavy duty, metalic body with metalic blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 457mm sweep, 1440RPM, CFM 4000 with lauvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including making hole on wall grouting bolts nuts washers, etc. complete all as speceified and as directed |
| 6 | S&F Flame proof ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star ratedcomplete all as specified and as directed by Engr in Charge.Note : Regulator will be paid separately under respective item of the sch. |
| 7 | S&F Switch flame Proof rotary type with termination box in LM-6 16 A single Pole 240 V complete all as specified and as directed by Engr in Charge. |
| 8 | S&F Switch flame Proof rotary type with termination box in LM-6 25 A single Pole 240 V complete all as specified and as directed by Engr in Charge. |
| 9 | M&L for flame proof weather proof switch socket & plug combined 16 A 250V(2P + earth) complete all as specified and as directed by Engr in Charge. |
| 10 | M&L for flame proof weather proof switch socket & plug combined 25 A 250V(2P + earth) complete all as specified and as directed by Engr in Charge. |
| 11 | S&F flameproof stepped type electronic fan regulator complete all as specified and directed |
| 12 | S&F sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 13 | S&F MCBs 32 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB, complete all as speceified and as directed . |
| 14 | S&F MCBs5 to 40 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB, complete all as speceified and as directed. |
| 15 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth forlaying of cables erection of pole etc and getting out in soft loose soilcomplete all as speceified and as directed |
| 16 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in soil complete all as speceified and as directed |
| 17 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point as in soil complete all as speceified and as directed |
| 18 | M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as speceified and as directed |
| 19 | S&F GI tubing 40 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position all as specified and directed. |
| 20 | Supply and Laying LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 4 core 16 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply, installation, testing & commissioning of outdoor type (IP-65 protection) 10 KVA capacity Servo controlled voltage stabilizer (confirming to BIS 9815, Part-I:1994, reaffirmation 2019 latest version), single phase, 50 Hz, Naturally Oil cooled, unbalanced load and unbalanced input type, copper wound, metallic body duly power coated with lifting hooks two Nos., digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following other specification complete all as specified & directed:-a) Servo Controlled technology.b) Type-Single PhaseC) Cooling-Oil-cooled with first filling of oild) Testing - As per IS: 9815 and IS:2026e) Input voltage-170V-280V (Ph-N)f) Output voltage-240 +/-1% (Ph-N)9) Frequency-50Hz +/-5%h) Metering-Digital Microprocessor basedj) Efficiency - Not less than 98%k) Resporise time - less than 10 mili secondl) Insulation Resistance (IR) - More than 6 Mega ohms at 500 V DCm) Protections Provided-Over load, short circuit Protection, High/low voltage cut off, bypass arrangement.n) Construction - Outdoor-type with IP65 Protection |
| 22 | Supply, installation, testing and commissioning of 10KVA Isolation transformer, Single-Phase, Oil-cooled, outdoor-type with IP65 Protection and with first filling of oil as per IS:335, Primary-240V, Secondary 240 V, Input frequency 50 Hz+/-3%, breakdown strength 1.5 KV for 60 seconds. Insulation to be more than 1000 Mega Ohms, Impedance Voltage-3-4%. Output neutral will be isolated from system neutral complete all as specified and directed. |
| 23 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead strip 32 x 6 mm size upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.Note: if desired earth resistance is not found then entire earthing shall be re-done by Contractor without accruing any extra cost to the Govt. |
| 24 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as speceified and as directed |
| 25 | M&L for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.Note :- Thickness of sand cushion after punning down i.e 18 cm shall be measured for payment. |
| 26 | M&L for boring/auguring suitable hole & insertion of 40/50/80mm mm dia GI pipe including supply and inserting pipe not less than 600 mm below existing PCC/road/hard standing complete all as specified and directed. Notes: (a) Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted. (b) GI pipe of suitable size bore will be measured and paid seperately under relevent item of the schedule. |
| 27 | Supply and laying in trenches / under road / fixing on wallsteel water tubing galvanised 50 mm bore medium grade ISI markedwith all fittings complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F GI tubing 50 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position complete all as speceified and as directed |
| 29 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as speceified and as directed |
| 30 | S&F LT Feeder pilllar 3 phase 433 Volts outdoor type made out of 3.15 mm thick M S Sheet with 200 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black)including internal wiring with locking arrangments and angle iron stand of size 40 x 40 x 6mm frame grouted in ground with PCC foundatiuon 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connections,lugs and cable gland including 2 coat of paint over a coat of red oxide primer with following accessories complete all as specified and directed.(a) MCCB TPN 125 Amps 50 Hz, 415 V with rupturing capacity 25 KA - 01 Nos (Incoming)(b) MCCB TPN 63 Amps 50 Hz, 415 V with rupturing capacity 25 KA - 02 Nos (Outgoing)(c) MCB TPN 40 Amps 50 Hz, 415 Vwith rupturing capacity 16 KA - 02 Nos (Outgoing)(d) Voltmeter (Digital type)-01 No,(e) Ammeter CTs (50/5Amps) (Digital type)-01 No,(f) Indicating lamps (RYB) -01 Set(g) PCC Foundation (Civil works) for grouting of panel |
| 31 | S&F copper strip of size 10x3 mm complete with saddles and base insulators (made out of porcelene/PVC) and fixing screws on roof and down side conductors complete all as specified and directed |
| 32 | S&F test point terminal block made of gun metal or phosphorus bronze, size 75x75x25mm drilled and screwed with sheet metal enclosure of size 100x100x100mm made out of steel sheet of thickness not less than 1.6mm 1ncluding 3 Nos 8mm dia 25mm long hezagonal head screw, complete all as specified and directed. |
| 33 | Supply installation testing and commissioning of a set of maintenance free tripod earthing system consisting of 3 No. of copper bonded Earth Rod of 10feet length, 17.2mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x50x6mm for long lasting and connection. Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 5KA Fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriter labouratories confirming to comply with UL467 international standard for grounding and and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed, Resistivity of the earth enhancing compond should be less than 0.05 ohm meter- an international standard for Earth enhancement compound by NABL accredit Lab. Note: the rate for interconnection of tripod earth with copper strip of size 20x3mm and poly carbonate earth pit cover-03Nos shall deemed to be included in the quoted rates. The Earth result should be less than 1ohm and the result will be checked in presence of user rep & MES Rep if desired earth resistance is not found than entire earthing shall be re-done by Contractor without accruing any extra cost to the Govt. |
| 34 | Supply, Installation, testing and commissioning of Monoblock pump centrifugal type of capacity 15KW/20HP three phase 415volts, 50HZ, single stage, head range: Min 30mtrs, Discharge: Min, 18lps, impeller cast itron/Noryl, Insulation: \"F\" class, protection : IP 55, suction/ delivery size: 100mm/80mm, speed Min 2900, Certification/Accreditation: ISI, complete with and including all connected accessories complete all as specified and directedby Engr-In-Charge.Make : Kirloskar KDI series of Model NO. 2050 or of equivalent in KSB Crompton |
| 35 | S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts in any shape or size etc, complete all as specified and directed. Note: Size section and shape of steel sections shall be as directed. by Engr-in-Charge. |