| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frame nexc 1.5 sqm each with shutters (without taking off shutters from the frame) including accessories complete all as specified and directed. |
| 2 | Taking down chowkhats or frame exc 1.5 sqm but n exc 4.00 sqm each with shutters (without taking off shutters from the frame) including accessories complete all as specified and directed. |
| 3 | S&F powder coated aluminiumfabricated work as in shutters/frames for doors, windows/vents, partition as per manufacturer instruction complete including necessary jointing cleats, anodised aluminium snap beading , rubber neoprane including taking down damage portion of damage doors,windows or taking down complete door/window complete all as specified and directed.Note:Rates are including for necessary new fittings fordoor/window i.e handle, tower bolt, butt hinges , filling of gap between wall and windows by silicon/epoxy sealant etc. complete. |
| 4 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus ofelasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. |
| 5 | S & F factory made 100% solid PVC flush shutter 28 mm thick, made from Co- Extruded three layer rigidPVC foam sheet (singleExtruded) with density not less that 600 kg/cbm outer layer (0.8-1 mm) thick should be of rigid pvc with density of not less than 1400 kg/cum manufactured by an ISO 9001-2015 certified company. Door should be water proof, Termite proof , fire retardant & having good screw holding capacity complete all as specified and directed and Manufacturers drawing. |
| 6 | S&F for factory made 30mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated WiremeshDoor Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm , having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter. For fixing Mosquito mesh and XTN aluminium mesh combinly panel area of door except stiles and rails to be panelled with mesh with self tapping round headed scresws at required distance, scres and edges covered with feathered pvc edge beading all around of mesh and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws complete all as specified and directed. |
| 7 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. |
| 8 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made as per manufacturer instruction complete all as specified and directed. |
| 9 | M&L cement concrete Type B-0, 1:2:4 using 12.5 mm graded stone aggregate as in coping, bed blocks, lintels, cills, steps, seismic and other similer bands, kerbs and like etc complete all as specified and as directed. |
| 10 | S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 11 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperure 1.40 mm and fixedwith stainless steel wire staples fixed complete all as specified and directed.. |
| 12 | S&F 100 mm stainless steel but hinges, extruded ISI marked, complete all as specified and directed. |
| 13 | S&F 150 mm Stainless steelhandles ISI marked, cast type, complete all as specified and directed |
| 14 | S&F 150 mm Stainless steeltower boltsISI marked, extruded section and fixed complete all as specified and directed. |
| 15 | S&F stainless steel ISI marked,300 mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed |
| 16 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 17 | M & L forGranite tile of 15-18 mm thick on vertical surfaces such as skirting, dado, steps, cills, wash basin table top, flooring, kitchen slab,machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing over andincluding rendering 15 mm thick back coatin CM (1:6) complete all as specified and directed. |
| 18 | M&L for size 1200mm x 600 mm (4\" x 2\" ) Machine cut kota stone slab flooring & skirting 20-22 mm thick over cement screed base 15 mm in CM 1:6laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab grinding and mirror polishing complete all as specified and directed. |
| 19 | M&L for non skid ceramic coloured tiles 7mm to 8 mmthick (square /rectangular) joint free area of each tile exceeding 0.11 Sqm, but not exceeding 0.18 Sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified & directed. |
| 20 | M&L for coloured glazed tiles in walls /vertical surface 350 x 250 x 7 mm/ 450X300X7mmthick set and jointed over and including 10 mm thick rendering even and rough in CM 1:4 for backing of tiles, jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed. |
| 21 | M&L for vitrified Ceramic light shade tiles 7 to 8mm thick (square/rectangular) polished, of any shade area of each tiles exc 0.18 sqm but not exceeding 0.36 Sqm, in floors etc having a screed bed 15 mm in CM (1:6) , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 22 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed. |
| 23 | M&L for reinforced cement concrete (nominal mix) using 20mm graded aggregate type B1 1:2:4 on as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajjas and the like complete all as specified and directed. |
| 24 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 25 | M & L PCC 1:3:6, type C1 (using 20 mm graded agg) as in plinth protectionincluding demolition of cement concrete in ground floor and paving n exc 15 cm thickness (below or above ground floor) complete all as specified and directed. |
| 26 | M&L for hardcore of broken stone or boulders of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 27 | M&L PCC 1:4:8 type D2, using (40 mm graded agg) ,75 mm thick asin sub base of flooringincluding demolition of cement concrete in ground floor and paving n exc 15 cm thickness (below or above ground floor) complete all as specified and directed. |
| 28 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 29 | Demolition of brick work, built in Cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 30 | M&L for brick work with sub class ‘B’ (modular size bricks) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 31 | Taking down cement plaster on brick or concrete surfaces, including racking out joint, hacking for key, scrubbing down with water complete all as specified and directed. |
| 32 | S&F for Wire netting of galvanised steel wire 0.71 mm dia fixed with tinned tacks of wire staples size of mesh 12 mm for fixing at junction of wall, beam and columns prior to plastering complete all as specified and directed. |
| 33 | M & L for 15 mm thick ready mix plaster on brick/concrete/stone surfaces including finishing the surfaces fair and even (without using extra cement) and smooth as per manufacturer\"s direction complete all as specificed and directed. |
| 34 | M & L for applying Two coats of Damp proof coarse (Primeless high build water based elastomeric exterior wall waterproof acrylic coating for exterior surfaces) designed with weather resistant acrylate polymers, UV resistant and good hiding and spreading,developing a strong intercoat adhesion with the substrate therefore no separate primer is required, features such as Waterproofing, UV protection, Anti algal resistance, crack bridging of elastic films covering hair line cracks, long term protection, colour variants. Preparation of surfaces by cleaning the surfaces till it is free from dust , grease and flaking paint , any unstable paint to be removed , using high pressure wash or scraper , whichever is appropriate . Algae and fungus on the wall to be removed by using high pressure wash or coir brush and shall be treated with fungicidal solution , all surface cracks upto 5 mm width should be filled up with Crack-X-paste as specified complete all as specified and directed. Note : 1. Application for verticle surface fresh plaster or repainting on old prepared surfaces.2. Use it directly from the container. Stir contents well before use.3. Brush/ roller apply a self priming coat of it on the vertical wall surface in SSD condition, diluting 1 litre with 100 ml clean potable water. Allow it to dry for 4-6 hours.4. Apply a coat of it without dilution as waterproof top coat, either by roller or brush with force coverage at the rate of 3.7- 4.1 Sqm / litre to achieve DFT of 100- 110 microns. Allow it to dry for 4- 6 hours. Lighter shades of white base on the top of dark colours need additional coat for finishing.5. An additional coat should be applied in case of horizontal surfaces like the top of windows, ledges, parapet wall etc. Allow the coating to full air cure for 7 days. |
| 35 | M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification and Two coats on new work complete all as specified and directed. Note: Putty shall be measured and paid for separately under respective item. |
| 36 | Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and applying two coats of oil emulsion distemper,white or tinted over one coat of white cement based putty (where required) complete all as specified and directed.Note: Putty shall be measured and paid for separately under respective item. |
| 37 | M&L for applying 1.00 mm thick wall care putty on wall & ceiling complete all as specified and directed. |
| 38 | M & L for preparation of new surfaces of wall including brooming down or steel wire brushing, and applying three coats of white wash complete all as specified and directed. |
| 39 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beads/aluminium snap beading with neoprane rubber gasket or wire staples etc. fitted to metal/wooden/aluminium surrounds complete all as specified and directed |
| 40 | S & F in repairs stainless steel 20 mm dia drapery/ curtain rod with fancy type brackets/holders for hanging and fixing complete all as specified and directed. |
| 41 | S&F in replacement WHB oval type counter top minimum size 24x14x5 inch including CP waste coupling, PVC waste pipe, PVC connection 600mm long, brass cromium plated pillar tap single lever mixer for hot and cold 300mm long and 15mm dia fixed over existing granite counter and fixed complete all as specified and directed. |
| 42 | S&F in repairs Soap dish, CP fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 43 | S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white(excluding fixing bolts, flushing cistern and flush pipe) and including plastic seat cover with aluminium hinging device complete all as specified and directed. |
| 44 | S&F in repairs vitreous china WC squatting pan \"Orissa Pattern\"size 580mm x 440mm white with integral foot rests, including provn of cement concrete bedding and \"P\" or \"S\" trap as required incl connection to trap , and to flush pipe, anti syphonage pipe, etc. complete including making good to floor complete all as specified and directed. |
| 45 | S&F in repairs 10 ltrs capacityPVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets incl flushing pipe complete all as specified and directed. |
| 46 | S&F in repair Vitreous China Urinal, full stall type,white (excluding flushing cistern, flush pipe and waste pipe) including LDPE pipe 32 mm dia complete all as specified and directed. |
| 47 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed. |
| 48 | S &F in repair for designer bevelled edge frameless looking mirror of selected quality glass of min 6mm thick fixed on wall with screws in any size complete all as specified and directed |
| 49 | S&F in repairs 100mm dia CP grating complete all as specified and directed. |
| 50 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 600 mmfixing complete all as specified and directed. |
| 51 | S&F in repairs PVC (SWR) floor trap plain with grating incl jointing with solvent cement 75mm bore complete all as specified and direcetd. |
| 52 | S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 53 | S&F in repairs for chromium plated shower rose 125 mm with or without swivel joints, with shower arms any size, including fixing to steel pipe or union complete all as specified and directed. |
| 54 | S&F in repairs 15 mm Stop valves (Concealed type), chromium plated fancy type long shank and cup , cast copper alloy, screwed down, highpressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 55 | S&F in repairs bib taps chromium plated 15 mm dia (having weight not less than 0.40 kg as per SSR Part-I clause 18.14.2 ) cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule , complete all as specified and directed. |
| 56 | S&F in repairs stop valves 15 mm bore (having weight not less than 0.40 kg externally threaded as per SSR Part-I clause 18.14.2 ) cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unioncomplete all as specified and directed. |
| 57 | Taking up or down 20 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 58 | S&F 20 mm GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors (Concealed type) complete all as specified and directed. |
| 59 | Taking up or down 15 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 60 | S&F 15 mm GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors (Concealed type) complete all as specified and directed. |
| 61 | M&L for precast cement concreteType B1 1:2:4(20mm graded aggregate) as in landings, cover slabs, precast man hole covers, set in CM 1:4 completeall as specified and directed. |
| 62 | Excavating in trenches n exc 1.5m deep and n exc 1.5 m wide for foundation etc and getting outin any type of soils complete all as specified and directed. |
| 63 | Demolition and breaking up of 150 mm dia of drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 64 | M&L for cement concrete 1:4:8 type D2, concrete bed to drain pipes 150 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested; complete all as specified and directed. |
| 65 | Cutting into existing manholes /septic tanks for connecting new drains, making good to pipes and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for dia 150 mm complete all as specified and directed. |
| 66 | Returning filling in any type of soil including spreading levelling watering and well ramming in layers n. exc 25 cm complete all as specified and directed. |
| 67 | Removingexcavated material exc. 250 m but n exc. 500 m and depositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed. |
| 68 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/floors complete all as specified and directed. |
| 69 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls fixed with MS clamp complete all as specified and directed. |
| 70 | S&F in repair 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 71 | S&F in repair PVC (SWR) bends any radius 110 mm dia complete all as specified and directed. |
| 72 | S&F PVC (SWR) vent cowl 110 mm complete all as specified and directed. |
| 73 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 74 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 75 | Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 Grade St-240 complete all as specified and directed. |
| 76 | Dismantling of asbestos cement (corrugated, semi corrugated etc.) sheets inroof coverings, including ridge complete all as specified and directed. |
| 77 | S&F pre- painted galvalume aluminum zinc coating GI Based corrugated steelsheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas,fixedwith self tapping screws complete all as specified and directed. |
| 78 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 79 | M&L for preparation of new or previously untreated surfaces of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer, complete all as specified and directed. |
| 80 | M & L for preparation of old painted steel surface of any description exceeding 10cm width or girth and applying one coat of synthectic enamel paint of approved tint complete all as specified and directed. |
| 81 | M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 82 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of semi perforated 12mm thick 12mm thick micro tegular Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and Lshape level adjuster of size 85x25x2mm.Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge including dismantling boarding any description, fixed in any position. |
| 83 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 84 | M&L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor -stranded copper conductor1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathedFRLS cable 1100 volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc,ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with sheel metal ms flesh box, white cover plate with frame for fixing modular switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLScable as earth continuity conductor to common earth and connecting to earth dollycomplete all as specified and directed. |
| 85 | All as per item No.84.00 here -in- before butwiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. |
| 86 | All as per item No.84.00 here -in- before butwiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. |
| 87 | All as per item No 84.00 above, one 3 pin socket outlet5 Amps on same board complete all as specified and as directed. |
| 88 | All as peritem No.84.00 above, but 3 pin socket outlet 5 amps on independent board elect wiring 1.5 sq mmcomplete all as specified and directed. |
| 89 | S&F Modular Switch piano, flush type, single pole, one way, 6Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. |
| 90 | S&FModular Socket outlet, 2 module,multipurpose having provision for 2 & 3 pin, 6 Amp flush type,240 volt AC ISI marked complete all as specified and as directed. |
| 91 | S&F in repairs Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. |
| 92 | S&F Modular Switch piano, flush type, single pole, one way, 16Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. |
| 93 | S&FModular Socket outlet, 2 module,multipurpose having provision for 2 & 3 pin, 16 Amp flush type,240 volt AC complete all as specified and as directed. |
| 94 | S & F lamp holderPVC/polycarbonate type with back plate suitable for batten fittingswith 9 Watt LED Bulb complete all as specified and as directed. |
| 95 | Taking down and Supply and fixing BEE 5 stare rated, B/S certified BLDC decorative ceiling fan 1200mm sweep, 230Volt, Min dia delivery 225 CFM, anti dust, aerodynamic aluminium blades & body with advanced brushless technology bosed BLDC copper winding motor with all accessories such as regulator, conneting down rod, clamps, canopy, remote with boost, timer & Sleep mode complete all as specified and as directed.Note:-(i) Cost of taking down old ceiling fan, regulator & deposit to MES Store yard in also include in quoted rate.(ii) Warranty of BLDC ceiling fan for 2 year & 5 Year of BLDC Motor. |
| 96 | Supply and fixing energy saving LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing toughened glass thermal shock and impact resistance and heat resistant complete with powered by integrad electronice driver with out put short circuit protection, surge protection, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete toughened glass, lens IP 66, IK-08 and with system efficacy of 125 lm/W CRI >70 , PF≥0.95 complete all as specified and as directed. |
| 97 | S&F in sheet metal plug & socket, single pole and neutral ISI marked with and including 1 No single pole MCB 20 Amps 240V complete all as specified and directed |
| 98 | Supply and fixingBEE star ratedGeyser with advanced safety featuresmaking all necessary arrangements for connection tocold and hot water pipe lines and testing of storage water heater, 240V, SP, 50 ltrs capacity including PVC hot and cold water pipe connections complete all as specified and as directed.NOTE:New geyser has been taken for building with no provision of geysers. |
| 99 | Taking down old unserviceable sub main wiring of any size and any discription complete all as specified and as directed. |
| 100 | M&L for Sub main wiring with two single core FRLS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn innon metallic rigid PVC conduit of size 25 mm dia ISI marked including PVC insulated unsheathed 6 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified and as directed. |
| 101 | M&L for Sub main wiring with two single core FRLS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn innon metallic rigid PVC conduit of size 25 mm dia ISI marked including PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified and as directed. |
| 102 | S&F LED 20/21Watt tube light fitting (T8 type) ,including LED retrofit tube 20/21 W one side connection type, 240 v, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative patti suitable for surface mounting on wall,complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified and as directed. |
| 103 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 104 | Taking down main switches/MCB DBs of any capacity/type including MCBs complete all as specified and as directed. |
| 105 | S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 08 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. |
| 106 | S & F in repairs MCB SPNsuitable for 240 volts, AC supply32 Amps, C Curve,with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 107 | S & F in repairs MCB TPNsuitable for 240 volts, AC supply40 A to 100A, C Curve,with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 108 | Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) and space forMCCB as incomer, with metal door ( IP-56 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. |
| 109 | S&F MCB SP 240 volts 6 to 32Amps, 10 KA breaking capacity,\"B\" Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 110 | Taking down & Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers ISI Marked complete all as specified and as directed. Note:- Old/unserviceable exhust fans to be deposited at MES Store yard |
| 111 | S&F in repairs LED Ultra slim decorative aluminium casted edge ceiling light, protuded type ceiling mounted LED 2x2, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5sqmm two core complete all as specified and directed. |
| 112 | Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and as directed. Note:- Old/unserviceable meter to be deposited at MES Store yard |
| 113 | S&F Decorative garden light made up of high grade unbreakable polycarbonate material suitable for and including 20W LED lamp B22 base.Mounting pole dia 40/60mm dia, Dimension width 300mm and height 600mm complete all as specified and as directed. |
| 114 | Excavation in trenches nexc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, erection of poles complete all as specified and as directed. |
| 115 | Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 116 | Sand cushioning/sand coveringfor underground cable protection complete all as specified and as directed. |
| 117 | Supplying and laying Class LV, Type I, flat, size 250mm x 150mm x 40mmfor cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed. |
| 118 | Takng down old unservicable cable and Supply and Laying XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16x4 sqmm, laid in trenches/floor or fixed on wall/pole complete all as specified and as directed. |
| 119 | S & F of GI Tubes, \"light grade\" galvanised, with all fitting and laid in floors, under road, pavement or hard standing steel water tubing bore of tube 25 mm complete all as specified and as directed. |
| 120 | Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised iron earth wireof 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 SSR including earth pit in any soil char coal common salt , 15 mm all around earth plate PCC (1:3:6) type culprit, with 40 x40x6 mm angle iron frame and PCC cover (1:2:4) type B1 , water pipe funnel and GI protection pipe light grade 15mm dia upto panel connecting earth lead to panel all as specified and directed. Note : Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate. |
| 121 | Taking up or down steel tubing of 25 mm bore and connection including cleaning for refixing or removal in store complete all as specified and directed. |
| 122 | Supply , fixing & laying in repairs GI tubing of 25 mm bore medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittingsfor laid in trenches/wall/ceiling/ floor/complete all as specified and directed. |
| 123 | Supply , fixing & laying in repairs GI tubing of 20 mm bore medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittingsfor laid in trenches/wall/ceiling/ floor/complete all as specified and directed. |
| 124 | Taking out UNSV Gun metal globe & S&F Gun metal globe or gate valves of 25 mm bore, conf to IS 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position complete all as specified and directed. |
| 125 | Taking out UNSV Gun metal globe & S&F Gun metal globe or gate valves of 20 mm bore, conf to IS 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail