| Sl. No. | Item Description |
| 1 | Engaging of 1 No \"C\" Licence Holder (Supervisor)of day to day maintenance of Electricalmaintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, HT/LT Panels , MCBs, MCB DBs, MCCBs, SFUs, FSUs etc., andall types of fans / light fittings,UG cables etc., complete all as directed by the Engineer-in-charge. ( 01 No.) (Qualification: Diploma in Electrical Engineering with 10 years related experience/ITI with 12 years or experience (supervisory) in maintenance job)(Qualification: ITI certificate with 03 years experience in operation of 11KV / 415V Substation and equipment and DG Sets along with valid 11KV /415V Supervisor permit /C- certificate/grade C-License Holder) (Higly Skilled).He is resposonsible to maintain & update the all logbook of preventive maintenace E&M equipment(Substation & DG sets etc...) with respective staff.[1 No \"C\" Licence Holder ( Highly Skilled)]. Note:-1.He is the responsible for maintain the day to day complaint Register, Preperation of Duty Roster, Material Consumption Register, Log Book/Log sheets and to up keep the neat & Tidy of installations with installed plants & machinaries as per the direction of Engineer-in-Charge 2.He is the responsible for HT Metering cubicle to monitor & maintain all parameter readings.3.He is the responsible for timely calibration of LT ACB\"s/MCCBs and Earth Fault Relays and Over Current Relays.4.He is the responsible for HT Panels, Transformers, ACBs, MCCBs,APFC Panels with connected Capacitor Banks,Power Contactors & Relays, Up Keep & maintain records for earth results in the HT & LT installations as per the direction of Engr-in-Charge.5.During Main EB supply failure to monitor the running of stand by DG Sets and maintain the Plant Running Record Book with all parameters.6.To maintain the EB Shutdown Register & obtain the necessary signature from EB authorities . (It should be talley with Stand By DG Set PRRB) |
| 2 | Engaging an Electrician Cum DG Operator cum Panel opearator for day to day operation of Substation, DG sets, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andday to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, UG cables, DG Setetc complete all as directed by the Engineer-in-charge.; andalso Preventive maintenance of above mentioned equipment as per standerd check list and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge.. Skilled (ITI Certificate with 3 Years Experience)- 4 Nos (3 Shift+1 Reliever) |
| 3 | Electrician Cum DG Operator-1 (as detailed above) |
| 4 | Electrician Cum DG Operator-2 (as detailed above) |
| 5 | Electrician Cum DG Operator-3 (as detailed above) |
| 6 | Electrician Cum DG Operator-4 (as detailed above) |
| 7 | Helper toElectrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, in routine operations and preventive/corrective maintenance activities likeAssisting in electrical fault isolation and repair, Supporting maintenance of LTpanels, control wiring, MCCs, etc.Handling tools, material shifting, and cleaning of electrical panels,and Coordinating during shutdowns, emergency operations, and safety drills complete all as directed by the Engineer-in-charge. ( 1 nos Un Skilled) |
| 8 | Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 9 | Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 10 | Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 11 | Supply of 25 mm iron staples/ saddles/ screws |
| 12 | Supply of 25 mm dia. ISI marked, PVC conduit |
| 13 | Supply of 25 mm PVC bends |
| 14 | Supply of 25 mm PVC couplers |
| 15 | Supply of Modular GI box for 4module |
| 16 | Supply of Modular GI box for 6 module |
| 17 | Supply of Modular GI box for 8 module |
| 18 | Supply of Modular GI box for 12 module |
| 19 | Supply of S.P. 5/6 amps, one way modular switch, ISI marked |
| 20 | Supply of S.P. 15/16 amps, one way modular switch, ISI marked |
| 21 | Supply of 3 pin 5/6 amps modular socket outlet, ISI marked |
| 22 | 6 pin 15/16 amps modular socket outlet, ISI marked |
| 23 | Supply of Stepped type Modular Fan regulator (2-module) |
| 24 | Supply of Modular blanking plate |
| 25 | Supply of Modular base & cover plate for 3/4 module |
| 26 | Supply of Modular base & cover plate for 6module Single & Double Row |
| 27 | Supply of Modular base & cover plate for 8module |
| 28 | Supply of SP 5/6A one-way piano switch, ISI marked |
| 29 | Supply of SP 15/16A one-way piano switch, ISI marked |
| 30 | Supply of 3 pin 5/6A piano socket outlet, ISI marked |
| 31 | Supply of 6 pin 15/16A & 5/6A piano socket outlet |
| 32 | Supply of Bell push, piano type |
| 33 | Supply of Call bell/buzzer, single phase |
| 34 | Supply of PVC Batten/Angle Holder |
| 35 | Supply of 6 amps. to 32 amps. ratings , SP MCB, \"C\" curve, 10 KA breaking capacity |
| 36 | 6 A, to 32 A, ratings, SPN MCB, \"C\" curve, 10 KA breaking capacity |
| 37 | Supply of Single pole, Blanking plate |
| 38 | Supply of 63 amps., 4 pole isolator |
| 39 | Supply of 63 amps. rating, 4 pole RCCB, 30mA |
| 40 | Supply of 25 amps. rating, 2 pole RCCB, 30mA |
| 41 | Supply of 20 amps. SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure |
| 42 | Supply of Aluminium lugs for up to 50 sq. mm cable |
| 43 | Supply of Aluminium lugs for70 to 120 sq. mm cable |
| 44 | Supply of GI saddles 19mm x 0.55mm for conduit |
| 45 | Supply of 250 mm X 200 mm H.T. danger notice plate |
| 46 | Supply of 200 mm X 150 mm M.V. danger notice plate |
| 47 | Supply of Coke |
| 48 | Supply of Salt |
| 49 | Supply of 5 Watt/7Watt LED Down lighter (SMD Type/Recessed) (System lumen efficacy ≥ 105 < 120 lm/Watt ) ofPowder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 50 | Supply of 36 watt LED Panel light 2x2 ft. (System lumen efficacy ≥105 1.20 mm)Powdercoateddiecast/Extruded aluminium Body (Thickness > 1.20 mm) |
| 51 | Supplying of 18 Watt LED Recessed/surface Down lighter (Round / square/ Rectangular)LED Down lighter (COB Type) (System lumen efficacy ≥ 105< 120 lm/Watt ) of following body materials.Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 52 | Supplying of 18- 22 watt LED surface mounted Batten light four feet (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.Powdercoateddiecast/Extruded aluminium Body (Thickness > 1.20 mm) Make:Havells/Philips/Crompton/Wipro |
| 53 | Supply of 7W / 9W LED Bulb Make:Havells/Philips /Crompton /Wipro |
| 54 | Supply of 15W LED Bulb Make:Havells/Philips/Crompton/Wipro |
| 55 | Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor 1200mm,BEE 5 star rating, service value≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 56 | Supply AC Exhaust Fan 300mm (12”) Sweep (Light Duty) |
| 57 | Supplyof 300mm Sweep WALL MOUNTING FAN |
| 58 | SupplySurface Box [SupplySURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 3 Module |
| 59 | SupplySurface Box [SupplySURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 6 Module |
| 60 | Supply25A Modular PVC Box type Wall Socket with C-20A/C-25ASingle Pole MCB protected AC socket with Plug TopMake : Havells/orbit/anchor/MK/Legrand |
| 61 | Supply of PVC /cotton tape Role (10 Mtrs) |
| 62 | Supply of Empire tape Role (10 Mtrs) |
| 63 | Supply of 4 Pin LED PL-L-4P Round/squared 18W LED bulb/light suitable for existing panel lights Make: Havells/Philips/Wipro/Crompton |
| 64 | Supply of Base socket for 4 Pin LED PL-L-4P Round/squared 18W LED bulb/light suitable for existing panel lights Make: Havells/Philips/Wipro/Crompton |
| 65 | Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi) |
| 66 | Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals etc., complete (sizes in mm).Make : Hensel/Sadhrish |
| 67 | Supply of 6A, flush type Neon Indicator |
| 68 | Supply of Running capacitor 2.5/3.15/4.0/6.0 μF |
| 69 | Supply of63A, 415V Porcelain Rewireable Fuse UnitMakes: C&S/Standard/HPL/ Sputnik /Million / GoldMedal / GM/Benlo/Anchor |
| 70 | Supply of 100A, 415V Porcelain Rewireable Fuse UnitMakes: C&S/Standard/HPL/ Sputnik /Million / GoldMedal / GM/Benlo/Anchor |
| 71 | Supply of 200A, 415VPorcelainFuse Unitwith Extensionwith extension stripMakes: C&S/Standard/HPL/ Sputnik /Million / GoldMedal / GM/Benlo/Anchor |
| 72 | Supply of 6 SWG Copper Earth Wire (0.16 kg/m) |
| 73 | Supply of 8 SWG Copper Earth Wire (0.1155 kg/m) |
| 74 | Supply of 10 SWG Copper Earth Wire (0.075 kg/m) |
| 75 | Supply of 6-way neutral link, complete with insulated base, suitable for mounting in distribution boards, made of electrolytic grade brass with adequate current-carrying capacity, including all necessary accessories as required. |
| 76 | Supply of 12-way neutral link, complete with insulated base, suitable for mounting in distribution boards, made of electrolytic grade brass with adequate current-carrying capacity, including all necessary accessories as required. |
| 77 | Supply of 5 Amps 3 Pin Top |
| 78 | Supply of 15 Amps 3 Pin Top |
| 79 | Supply of HRC Fuse Link 6A to 35A |
| 80 | Supply ofHRC Fuse Link 45A to 63A |
| 81 | MCB DB SPN, 6 way double door |
| 82 | MCB DB SPN, 8 way double door |
| 83 | MCB DB TPN, 4 way (4+12) double door, Vertical type |
| 84 | MCB DB TPN, 8 way (4+24) double door, Vertical type |
| 85 | M&L Wiring for light /fan/exhaust fan /call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core multi stranded cable in surface/recessed medium class PVC conduit, with modular Switch, Modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conduuctor single core multi stranded cable etc., all as required and as directed. (Group \"B\") Note for Item S.No.1 & 2:- 1.GI Modular box, Modular Plate & Modular switches are included in the unit rate. |
| 86 | M&L Wiring for twin control light point with 1.5 sqmm FRLS PVC insulated copper conductor single core multi stranded cable in surface/recessed medium class PVC conduit, with modular Switch, Modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conduuctor single core multi stranded cable etc., all as required and as directed. (Group \"B\") |
| 87 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 2x2.5 Sqmm+1x2.5 Sqmm earth wire. |
| 88 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 2x4 Sqmm+1x4 Sqmm earth wire. |
| 89 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 4x4 Sqmm+2x4 Sqmm earth wire. |
| 90 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 4x6 Sqmm+2x6 Sqmm earth wire. |
| 91 | M&L for Earthing with GI Earth pipe 4.5 mtr long, 40 mm dia including acessories and providing masonary enclosure with cover plate and locking arrangements and water pipe of 2.7 metre long etc, with earth electrode, charcoal and salt all as specified and as directed by the Engr-in- Charge. |
| 92 | S&F including providing and laying earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia GI pipe from earth electrode including crimpting with copper thimble excavation and refilling as required at site on surface or in recess all as specified and as directed by the Engr-in- Charge. |
| 93 | LED Streetlight fixture 36 watt, powdercoatedpressurediecastaluminumbody(Systemlumen efficacy >135 lm/Watt) Supplying,installation,Testing&Commissioningof 50 watt StreetlightLED fixture. |
| 94 | LED Streetlight fixture 50 watt, powdercoatedpressurediecastaluminumbody(Systemlumen efficacy >135 lm/Watt) Supplying,installation,Testing&Commissioningof 50 watt StreetlightLED fixture. |
| 95 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering with suitable HDPEPipe for UG cable laying and refilling the trench etc as requiredand upto 35 sq.mm |
| 96 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering with suitable HDPEPipe for UG cable laying and refilling the trench etc as required. above 35 sq.mm and upto 95 sq.mm |
| 97 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 98 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 99 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB |
| 100 | Numbering of ceiling fan/ exhaust fan/ LED fittings/streetlights, Panels/DBs/Pumps etc...as required. ( paint and labour charges included) |
| 101 | Supply and transportation of 16 Sq mm X 4 core coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLES Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 102 | Supply and transportation of 25 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 103 | Supply and transportation of 35 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 104 | Supply and transportation of 50 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 105 | Supply and transportation of 70 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 106 | Supply and transportation of 95 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 107 | Supply & Fixing of D.O.L. Starter Panel, 415 V, 3-phase, 50 Hz, enclosed, with no-volt coil and thermal overload protection, single-phase preventer, voltmeter, ammeter and indication lamps, complete with all internal wiring, fuses/isolator, terminal blocks, glands, earthing, testing & commissioning, suitable for 5 to 7.5 HP motor. |
| 108 | Supply and fixing of 4.0 KVA 1-phase, automatic Electronic Voltage Stabilizer.Makes:V-Guard / Real Guard / Uni Stab / ITL |
| 109 | Rewinding of 5.0 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material and testing etc. as required make it in perfect working condition. |
| 110 | Servicing and repair of 5 HP /7.5 HP submersible pump including dismantling, cleaning, lubrication, supply and replacement of mechanical seals, impellers or diffusers as required, major overhauling with shaft alignment and balancing, reassembly, testing for flow/pressure and commissioning at site, including labour, hoisting/lowering, transport and handling charges complete as directed. |
| 111 | Taking down the the unserviceable monoblock Submersible pump set alongwith delivery pipes carefully from the Sewage sump of capacity 1.5 HP to 5 HP, 3 Phase and transport to workshop for repairs and after carryout the necessary repairs/rewinding etc…, and duly re-lowering the same after repairs all as directed by the Engineer-in-Charge. |
| 112 | Rewinding of 1.5 upto 5 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material including servicing of impellers, shafts and replacement of bearings etc..,and testing etc. as required make it in perfect working condition. |
| 113 | Taking down the the unserviceable Submersible Pump Set alongwith Column pipes carefully from the Bore well of capacity upto 7.5 HP, 3 Phase and transport to workshop for repairs and after carryout the necessary repairs/rewinding etc…, and duly re-lowering the same after repairs all as directed by the Engineer-in-Charge. |
| 114 | Rewinding & Servicing ofSubmersible Pump Set upto 7.5 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of copper wound rewinding including servicing of impellers, shafts and replacement of bearings etc.., andas required make it in perfect working condition all as directed by the Engineer-in-Charge. |
| 115 | Supply and fixing of 230V/ 275V, 50Hz rating of 20-60 micro farad.Starting capacitor |
| 116 | Supply and fixing of 230V/ 275V, 50Hz rating of 15-36 micro farad.Running capacitor |
| 117 | Supply and charging of fresh refrigerant and testing ofperformance of air conditioner 1.5 / 2.0 TR TR Window/ Split A.C /Cassette |
| 118 | Installation of Split Air Conditioners |
| 119 | Supplyandfixing Supply and filling of R-22 Refrigerant Gas |
| 120 | Removing of existing Split Air Conditioners without damaging to copper pipe. |
| 121 | Repairs and Installation of existing PCB in 1.0 / 1.5 /2.0 Ton Split A.C. Unit |
| 122 | Servicing the Split type 1/1.5/2.0 Ton AC Machine by Cleaning through the water jet pump with condenser cooling Coil etc., by blower and oiling the Fan Motor for the indoor and outdoor units and Cleaning all parts and putting the machine in working condition and charging the refrigeranet gas if required basis only at site all as directed by the Engr-in-Charge.(Note :1. If requirement of refrigerent gas is essential basis will be measured and paid under separate item. ie.for methodologyby weighing the gas cylinder before and after charging for how much gas have been charged.2. Otherwise servicing only accounted for this item). |
| 123 | Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Below 500 A /Above 500A Make: Conzerve/Elmeasure/Meco/HPL/L&T/ socomec: Digital type (96 mm x 96 mm) |
| 124 | Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required : Red/yellow/Green colour |
| 125 | Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required:Blue colour |
| 126 | Supply and fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required.Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL : Non-luminous type |
| 127 | Routine maintenance of 315 KVA transformer, including testing of insulation resistance, oil breakdown strength. Reconditioning / replacement of silica zel,cleaning of transformer and topping upto oil level ifrequired (extra cost will be paid for oil). |
| 128 | Testing of Transformer oil for dielectric breakdown strength. |
| 129 | Supply of new and tested transformer oil as per IS-335 - 1972 (per Ltr) |
| 130 | Filtration of transformer oil as per ISS specifications filters to dielectric strength above 40KV …….at site. (Per Ltr) |
| 131 | Painting to 315 KVA transformer with 2 coats Zinc chromate red oxide duly scraping existing paint followed by 2 coats of hammer ton grey paint etc., complete. |
| 132 | Supply and fixing of 12V 180 AH SMF battery with (36 Months) 3 years warranty, including wire leads, connections etc complete.Makes: Quanta / Racket / Exide. |
| 133 | Supply and Transportation of 5 HP,5star rated submersible motor pumpset, confirming to IS 8034 and motor confirming to IS 9283 with waterproof winding, Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415V ± 10%, Three Phase 50 Hz AC supply etc complete for6\" Bore well.Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi. |
| 134 | Supply Installation Testing and commissioning of self-healing MPP/MP type shunt capacitor Heavy duty Three phase 440 V, 50 Hz capacitor (Bank)conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. |
| 135 | General servicing & preventive maintenance ofupto 7.5 HP electric pump motor including IR test, terminal check, lubrication, alignment verification, cleaning, and test run. In the presence engineer in -charge |
| 136 | Sipply &FixingPressure Gauge0-10 Kg/Cm2 with siphon including taking down the old one as directed by Engr-in-Charge. |
| 137 | Painting of 6.0 m street light pole (MS tubular/swaged type) including thorough surface cleaning with wire brush/emery paper to remove rust, dust & loose paint, application of one coat approved anticorrosive metal primer and two coats of approved synthetic enamel paint of specified shade, including thinning, provision of brushes/consumables, and all lead, scaffolding/ladder work, complete as directed by Engineer-in-Charge. |
| 138 | Carrying out minor welding works on existing street light poles/pipes/structure including surface preparation by cutting/grinding, welding with suitable electrodes (E6013 or equivalent) using portable welding set, rectification of cracks, base plate, brackets/fittings as required, finishing the welded portion with grinding, application of primer, and one coat of synthetic enamel paint of approved shade, complete as directed by the Engineer-in-Charge. |
| 139 | Testing of earth pit including measurement of earth resistance using digital 3/4-wire earth resistance tester (fall-of-potential method or clamp/three-wire as applicable), providing site test certificate, signed by authorized technician, and submission of soft/hard copy report, complete as directed by Engineer-in-Charge. |
| 140 | Comprehensive servicing and testing of 1000A LT Air Circuit Breaker (ACB), including dismantling of arc chutes, thorough cleaning of fixed and moving contacts with approved solution, lubrication of mechanical moving parts, checking and adjustment of interlocks and auxiliary circuits, servicing of spring charging motor and ON/OFF mechanism, calibration and relay setting (LSIG / microprocessor-based), insulation and continuity testing, and restoration of the ACB to full serviceable condition with test operation, through manufacturer’s authorized service agency, all as per OEM standards of any make and model and as directed by the Engineer-in-Charge. |
| 141 | Supply, installation, testing and commissioning of digital multifunction meter (MFM) suitable for LT Panel, flush mounting type, accuracy class 0.5 or better, 3 phase 4 wire, CT/PT operated (programmable ratio), with LED/LCD display for V, A, kW, kVA, kVAR, PF, Hz, kWh, demand, THD, etc., having RS-485 MODBUS communication port, including supply of all materials, making cutout in panel door, fixing, wiring, CT/PT integration, termination with ferrules, testing and commissioning complete as directed by Engineer-in-Charge. |
| 142 | Supply and placing of Rubber Mat 2m x 1m suitable for 11 KV installation confirming to IS |
| 143 | Supply and fixing of First Aid Box complete with all First Aid Medicines |
| 144 | Supply and fixing of Shock Treatment Chart fixed in glass frame |
| 145 | Supply and fixing of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle |
| 146 | Supply and fixing of Metallic Danger Board as required by the Electrical Authorities |
| 147 | Refilling of 4.5 kg CO₂ type Fire Extinguisher, including evacuation of existing gas, cleaning and inspection of cylinder, refilling with CO₂ gas confirming to IS 15683, pressure testing, fixing of discharge hose and horn, re-sealing, labeling, and affixing inspection tag complete as directed by Engineer-in-Charge. |
| 148 | Refilling of 6 kg ABC (Dry Chemical Powder) type Fire Extinguisher, including emptying of old powder, internal cleaning, refilling with ABC powder confirming to IS 14609, re-pressurizing with nitrogen, checking of pressure gauge, sealing, and affixing of refill/service tag complete as directed by Engineer-in-Charge. |
| 149 | Refilling of 2 kg ABC (Dry Chemical Powder) type Fire Extinguisher, including emptying of old powder, internal cleaning, refilling with ABC powder confirming to IS 14609, re-pressurizing with nitrogen, checking of pressure gauge, sealing, and affixing of refill/service tag complete as directed by Engineer-in-Charge. |
| 150 | Supply & fixing of Wire mesh 20 gauge |
| 151 | Supply and fixing of Weld mesh for existing Lovers |
| 152 | Supply & Making heat shrinkable outdoor straight through joint for 3.5core x 25/35/50Sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 153 | Supply & Making heat shrinkable outdoor straight through joint for 3.5 core × 70/95/120 Sq.mm sizeof PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 154 | Supply & Making heat shrinkable outdoor straight through joint for 4 core × 6/10/16 Sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 155 | Rewinding of 900/1200 mm sweep ceiling fan motor (starting and running winding) including allnecessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameledwire with \"E\" class insulation material and making connections etc. as required. (New model ceiling fan) |
| 156 | Providing and Replacement of ball bearing of ceiling/exhaust fan as required. (NBC/ SKF) |
| 157 | Providing and Replacement of Gun metal bush of ceiling/ exhaust/cooler fan/ as required |
| 158 | Spray painting of ceiling fan of size 900/1200/ 1400 mm with two coats of white/ brown enameled paint after cleaning with sandpaper. Filling etc. as required. |
| 159 | Fabrication, Transportation, Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting on street light pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required POLE BRACKETS |
| 160 | Fabrication, Transportation and supplyand Fixing of 1.5 Mtr length Double Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe with flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required POLE BRACKETS |
| 161 | Supply and Fixing of Din Rail Terminal Blocks, Copper for UG cables upto 50 sqmm for LT Panels |
| 162 | Supply and Fixing of Phase Changeover in SS Enclosure ( including 3 phase indicators & 200 A Cam operated Rotary swiches for 3 phases) |
| 163 | Supply and fixing of 63 mm diaHDPE pipe for UG XLPE Cabling etc.. As required |
| 164 | Supply and fixing of 38mm/50mm mm diaHDPE pipe for UG XLPE Cabling etc.. As required |
| 165 | Painting to Electrical LT Panels:The work includes complete surface preparation of LT panels by removing rust, dust, grease and loose paint; application of one coat of approved red-oxide primer and two coats of synthetic enamel paint of approved make/shade; repainting of feeder names, danger sign, phase marking; masking/protection of live components; and handing over with a uniform smooth finish. All labour, tools, scaffolding, consumables, and safety precautions included.(Asian/Berger/Nerolac or equivalent) |
| 166 | Servicing, overhauling and repair of existing 5 HP / 7.5 HP starter panel including complete cleaning, tightening of terminals, megger testing, replacement of defective items such as thermal overload relay (TOR) or single-phase preventor (SPP) or control relays; re-fixing, wiring, termination, testing & commissioning; including all labour, consumables, tools & safety items etc. complete. |
| 167 | Supply, installation, testing and commissioning of Single Phase Preventer suitable for 3-phase starter panel, designed to protect motor against single phasing, phase reversal and phase unbalance. The device shall operate on 415 V, 50 Hz, automatically disconnecting the motor starter under fault condition and allowing restart only under healthy phase sequence. The unit shall be panel-mounting type with LED indication, suitable for continuous duty, complete with necessary wiring, connections, fixing arrangements, accessories and as directed by engineer In-charge.Make : Minilec / L&T / Siemens / ABB. |
| 168 | Fabrication, Transportation and supply of 1.0 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. (The design should be approved from field Engineers)POLE BRACKETS |
| 169 | Carryout routine maintenance, servicing and testing of 630A to 1500A L.T.ACB by cleaning fixed contacts, moving contacts and arc chutes including servicing and putting the ACB in perfect working condition after setting all relay and ON, OFF mechanism etc., done with only manufacturing companies |
| 170 | Carryout routine maintenance and servicing of LT. Cubical panel board having approximately 15 to 22 Nos of switches cleaning with power blower and servicing the contacts, tightening the connection ofincoming and outgoing cables, and checking the operating mechanism for smooth functioning of switches and putting them in smooth working condition. |
| 171 | Routine maintenance of transformer, including testing of insulation resistance, oil breakdown strength. Reconditioning / replacement of silica zel, cleaning of transformer and topping upto oil level ifrequired (extra cost will be paid for oil). |
| 172 | Supply and delivery of diesel for 100 KVA DG set at Hosur ESI Hospital, including cost of diesel, loading, unloading, transportation, carriage to site, and filling into the DG set complete all as directed by the Engineer-in-charge. |
| 173 | Quarterly service / Preventive maintenance of 100 KVA DG set, including checking and cleaning of air filter, fuel filter, oil filter, radiator, battery terminals, belts, hoses, and all electrical connections; checking of engine oil level, coolant, fuel system, and control panel parameters; testing of starting system, load test, and overall health check of DG set; submission of service report of OEM or OEM Authorized etc..complete as directed by the Engineer-in-charge. |
| 174 | Carrying out B-Check service for 100 KVA Diesel Generator set, including replacement of engine lube oil, oil filter, fuel filter, cleaning of air filter, checking and tightening of belts, hoses, battery terminals, radiator cleaning, inspection of alternator, checking of electrical connections, calibration of parameters, top-up of coolant, checking of safety shutdowns, trial run of generator under load, and submission of service report, complete all as directed by the Engineer-in-charge. |
| 175 | Providing / conducting complete fire audit Including submission of fire audit report for the whole premises by Certified fire safety auditors / NABH-approved auditors / State Fire Dept (NOC) / Third-party expert agencies. |
| 176 | Supply and fixing of escape signage boards made of rigid photoluminescent (glow-in-the-dark) sheet, with high-intensity luminous properties, including all accessories, fixing materials, supports, and as per approved sample and site requirement. |
| 177 | Supply and fixing of MS angle-fabricated fire bucket stand suitable for 4 buckets as per fire officer standards. |
| 178 | Supply and fixing of ABC stored pressure squeeze grip type fire extinguishers, 9 kg capacity, IS:15683 : 2006, filled with ABC Mono Ammonium Phosphate base powder-90 complete with discharge hose and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure Gauge, which work effectively on all class of fires (A, B, C & Electrical fires) with 5 years warranty Including transportation, all taxes and all labour charges etc complete. |
| 179 | LED Post top lantrne/ Gate light fitting of 25 Watts, with 4000K colour temperature, IP 65 with LED Lamp Make-Havells Mini Ruby Post Top LED Lamp or equivallent make of Philips/CG |
| 180 | Outdoor type Street light Feeder Pillar Box Panel of size not less than 11 CMx15.3CMx5 CM, suitable for 3 phase, max load 12 KW, MCB Rating 63 Amps TPN, Timer Astronomical, Product code-IHXTS0912A, Make-Havells or equivallent. |
| 181 | Earthing with G.I. earth plate 600mmx600mmx6 mm including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and all as directed by the Engr-in-Charge. Note :-1.Eearth electrode & GI protection pipe, earth links & nuts & bolts required at site are deems to be included in the rate quoted. |
| 182 | 63A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 183 | 100 A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 184 | 125 A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 185 | 200A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 186 | 250A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 187 | AMC for Hot & cold RO Plant of capacity 50 LPH of any make & model including Periodical maintenance and replacement of filters once in a year all as directed |
| 188 | Credit for dismantled materials old battery upto 180 AH |
| 189 | Credit for dismantled materials C/Fan/Wall Mount/Pedestal Fan (Old) |
| 190 | Credit for dismantled materialsExhaust Fan (Old) |
| 191 | Credit for dismantled materialsStreet Light Fitting (LED/HPSV – Old) |
| 192 | Credit for dismantled materialsLED Tube Light / Panel Light (Non-working) |
| 193 | Credit for dismantled materials LED Bulb (Non-working) |
| 194 | Credit for dismantled materials CFL Fitting – 2 Pin / 4 Pin (Old) |
| 195 | Credit for dismantled materials Fluorescent Tube Fitting (Old) |
| 196 | Credit for dismantled materials Fan Capacitor (Old) |
| 197 | Credit for dismantled materials Miniature Circuit Breaker (MCB – Old) |
| 198 | Credit for dismantled materials Distribution Board (MCB Box – Old) |
| 199 | Credit for dismantled materials Electrical Switches (Various) |
| 200 | Credit for dismantled materials 5A / 15A Sockets (Old) |
| 201 | Credit for dismantled materials Call Bell / Buzzer |
| 202 | Credit for dismantled materials Old Copper Wiring (Mixed Gauge, Insulated) |
| 203 | Credit for dismantled materials Aluminium Wiring (Scrap) |
| 204 | Credit for dismantled materials PVC Conduits / Flexible Pipes (Scrap) |
| 205 | Credit for dismantled materials Armoured UG Cable (Aluminium Core) – Scrapped |
| 206 | Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings: obtained as old unserviceable Iron Scrap. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail