| 1 | Engaging Substaion attendant Cum DG Operator cum Panel opearator for day to day( Gen shift /day) operation of Substation, DG sets, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings,UG cables etc complete all as directed by the Engineer-in-charge.andalso Preventive maintenance of above mentioned equipment as per standerd check list and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge.. Skilled (ITI Certificate with 3 Years Experience)- 1 Nos (01 Operator cum Electrician)Note:(Note for Item No.168,169 &170)1. He will maintain the shut down cum Log book register and duly enter all the parameters.2.During Gen Shift, DG Opr cum Electrician, Electrician & Helper should do the Electrical day to day complaints/maintenance work as per the direction of Engr-in-Charge.3. To attend the emergency complaints as and when required basis beyond the shift hoursas per the direction of Engineer-in-Charge with out claiming any extra amount. |
| 2 | Engaging an Electrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, OH lines, UG cables, DG Setetc complete all as directed by the Engineer-in-charge. (2 No\"s Electrician- Skilled )(ITI Certificate with 3 Years Experience). |
| 3 | Electrician-1 |
| 4 | Electrician-2 |
| 5 | Helper for Electrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, OH lines, UG cables etc complete all as directed by the Engineer-in-charge. ( 3 Nos Helper Un Skilled per day(02 Helper for Electricians+ 01 Helper for DG Opr cum Elect ) |
| 6 | Helper-1 |
| 7 | Helper-2 |
| 8 | Helper-2 |
| 9 | Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 10 | Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 11 | Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 12 | Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 13 | Supply of 20 mm dia. ISI marked, PVC conduit (including elbow, reducer etc) |
| 14 | Supply of 25 mm dia. ISI marked, PVC conduit (including elbow, reducer etc) |
| 15 | Supply of 32 mm dia. ISI marked, PVC conduit (including elbow, reducer etc) |
| 16 | Supply of 20 mm PVC bends |
| 17 | Supply of 25 mm PVC bends |
| 18 | Supply of 32 mm PVC bends |
| 19 | Supply of 20 mm iron staples/ saddles/ screws |
| 20 | Supply of 25 mm iron staples/ saddles/ screws |
| 21 | Supply of 32 mm iron staples/ saddles/ screws |
| 22 | Supply of 20 mm PVC coupler/Junction box/Tee |
| 23 | Supply of 25 mm PVCcoupler/Junction box/Tee |
| 24 | Supply of 32 mm PVCcoupler/Junction box/Tee |
| 25 | Supply of S.P. 5/6 amps, one way modular switch, ISI marked |
| 26 | Supply of S.P. 5/6 amps, two way modular switch,ISI marked |
| 27 | Supply of S.P. 5/6 amps, one way modular switch, with \"Fan\" marking |
| 28 | Supply of S.P. 15/16 amps, one way modular switch, ISI marked |
| 29 | Supply of 3 pin 5/6 amps modular socket outlet, ISI marked |
| 30 | Supply of 6 pin 15/16 amps modular socket outlet, ISI marked |
| 31 | Supply of Modular bell push, ISI marked |
| 32 | Supply of Stepped type Modular Fan regulator (2 module) |
| 33 | Supply of Modular blanking plate |
| 34 | Supply of Call bell/ buzzer, single phase |
| 35 | Supply of PVC Batten/Angle Holder |
| 36 | Supply of Ceiling rose, 3 pin, 5 amps ISI marked |
| 37 | Supply of Modular PVC box for 2 module |
| 38 | Supply of Modular PVC box for 4module |
| 39 | Supply of Modular PVC box for 6 module |
| 40 | Supply of Modular base & cover plate for 2 module |
| 41 | Supply of Modular base & cover plate for 4 module |
| 42 | Supply of Modular base & cover plate for 6module |
| 43 | 20/22 Watts 4 Feet LED Fitting with LED |
| 44 | Supplyandfixing 7W / 9W LED Bulb |
| 45 | Supplyandfixing 15W LED Bulb |
| 46 | LED 36 Watts 2\"x2\" Square type surface/recessed litht fitting (HE) |
| 47 | LED 12/15/18/22 Watts Round type recessed litht fitting (HE) |
| 48 | Supplyandfixing 40W LED Street Light Fitting with LED |
| 49 | Supplyandfixing 72W LED Street Light Fitting with LED |
| 50 | 100W LED Flood Light Fitting with LED |
| 51 | Cable gland 10 Sqmm 2 core |
| 52 | Cable gland 16 Sqmm 2 core |
| 53 | Cable gland 16 Sqmm 4 core/25 Sqmm 3.5 Core |
| 54 | Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals & necessary clamps etc., complete (sizes in mm).Make : Hensel/Sadhrish/Sintex all as required at site and as directed by the Engineer-in-Charge. |
| 55 | Power Cpacitors of any type and model for power factor improvement, 3 phase 415 Volts |
| 56 | S&F Ceiling Fan of size 1200 mm , BLDC, BEE 5 star |
| 57 | S&F Wall Fan of size 450 mm |
| 58 | S&F Pedastal Fan of size 450 mm |
| 59 | S&F Modular Exhaust Fan of size 250 mm |
| 60 | AC Exhaust Fan of size 450 sweep Heavy Duty |
| 61 | Supplyandfixing AC Exhaust Fan 300mm (12”) Sweep (Heavy Duty) |
| 62 | Supplyandfixing MS / Fibre Louvers Shutters arrangements for 300mm AC Exhaust Fan |
| 63 | Supplyandfixing MS / Fibre Louvers Shutters arrangements for 450mm AC Exhaust Fan |
| 64 | 25 Amps motor starter 2 module (HE) |
| 65 | Hylem Sheet 3mm thick |
| 66 | PVC insulation tape |
| 67 | Empire tape |
| 68 | Cable route indicator (LT) duly fixed. |
| 69 | Rotary Handle 63/100 Amps, for MCCB\"s/SFU\"s. |
| 70 | HRC Fuses 63 Amps ISI Marked |
| 71 | HRC Fuses 125 Amps ISI Marked |
| 72 | HRC Fuses 200 Amps ISI Marked |
| 73 | MCB SP 6-32 Amps, 10 KA \"C\" curve |
| 74 | MCB SPN 6-32 Amps, 10 KA \"C\" curve |
| 75 | MCB TPN 6-32 Amps, 10 KA \"C\" curve |
| 76 | Metal clad plug and socket 20Amps, 2 pole |
| 77 | Sheet Steel enclosure for MCB\"s 2 Pole |
| 78 | Sheet Steel enclosure for MCB\"s 4 Pole |
| 79 | RCCB 25 Amps, double pole |
| 80 | RCCB 63 Amps, four pole |
| 81 | 6 Way SPN Double Door MCB DB |
| 82 | 8 Way SPN Double Door MCB DB |
| 83 | MCB DB TPN 4 way, IP-42 |
| 84 | MCB DB TPN 8 way, IP-43 |
| 85 | Digital Voltmeter 3 Phase |
| 86 | Digital Ammeter 3 Phase |
| 87 | Digital multifunctional meter |
| 88 | CT\"s of Ratio 100/5 set of 3 |
| 89 | Selector Switch for Ammeter |
| 90 | Selector Switch for Voltmeter |
| 91 | HT Rubber mat suitable for 11 KV 2 meter x 1 meter |
| 92 | First Aid box with all medicine |
| 93 | Shock treatment chart fixed in glass frame |
| 94 | Hand gloves 11 KV |
| 95 | Fire Extinguiser 2 Kg CO2 type |
| 96 | 1.5 TR Split type AC 5 Star rating |
| 97 | Automatic Voltage Stabilizer 4 KVA |
| 98 | S&F MS stand suitable for outdoor type split AC |
| 99 | Supply & Filling refrigerent gas R-410A |
| 100 | Supply & Fix 50 mm thick AVM pads. |
| 101 | Power Plug & socket 16 Amps 200/250 Volts 2 pole + Earth |
| 102 | Supply of Aluminium lugs for 16 sq. mm cable |
| 103 | Supply of 200 mm X 150 mm M.V. danger notice plate |
| 104 | Supply of Coke |
| 105 | Supply of Salt crystal |
| 106 | Rewirable Kit Kat Fuese Grips with brass contacts of 100 to 200 Amps both male & female set Make: Anchor or equivallent |
| 107 | Rewirable Kit Kat Fuese Grips with brass contacts of 32 to 63 Amps both male & female set Make: Anchor or equivallent |
| 108 | Supplyandfixing 5 Amps 3 Pin Top |
| 109 | Supplyandfixing 15 Amps 3 Pin Top |
| 110 | M&L Wiring for light /fan/exhaust fan /call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core multi stranded cable in surface/recessed medium class PVC conduit, with modular Switch, Modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conduuctor single core multi stranded cable etc., all as required and as directed. (Group \"B\") Note for Item S.No.1 & 2:- 1.GI Modular box, Modular Plate & Modular switches are included in the unit rate. |
| 111 | M&L Wiring for twin control light point with 1.5 sqmm FRLS PVC insulated copper conductor single core multi stranded cable in surface/recessed medium class PVC conduit, with modular Switch, Modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conduuctor single core multi stranded cable etc., all as required and as directed. (Group \"B\") |
| 112 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 2x2.5 Sqmm+1x2.5 Sqmm earth wire. |
| 113 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 2x4 Sqmm+1x4 Sqmm earth wire. |
| 114 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 4x4 Sqmm+2x4 Sqmm earth wire. |
| 115 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 4x6 Sqmm+2x6 Sqmm earth wire. |
| 116 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required for Upto 35 sq. mm.Note: 1.Excavation in any type of soil below ground level 0.30 Mtr (width) x 0.75 Mtr (depth) and upto 1.25 Mtr depth (maximum if required at site).2. Sand cushioning 15 CM on bottom of trench (below the cable) and 08 CM above the cable.( Punned thickness should be of 18 CM).3. Well burnt brick protection perpendicular to the cable all along the trench.4. Returning & filling of soil & Removing of surplus soil all as directed. |
| 117 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall/ surface as required for Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 118 | Supply and transportation of 10Sq mm X 2 coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 119 | Supply and transportation of 10Sq mm X 4 coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 120 | Supply and transportation of 16 Sq mm X 4 core core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 121 | Supply & Fixing cable jointing kit outdoor type with cast resin compound with ferruls for suitable for 4 core 16 Sqmm upto 35 sqmm |
| 122 | Supply & Making heat shrinkable outdoor straight through joint for 4 core × 6/10/16 Sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 123 | Supply & Making heat shrinkable outdoor straight through joint for 3.5core x 25/35/50Sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 124 | Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi) |
| 125 | Supply & Lowering vertical multistage 3 Phase submersible pump set with SS Shaft & CI body suitable for 120 LPM at 250 Mtrs head suitable for 7.5 HP all as directed. Makes: Kirloskar / Crompton / Texmo / CRI /KSB/Lubi/ PSG/ ARYEN VARSHA /Falcon/Prithvi |
| 126 | Supply & Lowering of Open well 3 Phase monoblock submersible pump set with SS Shaft & CI body suitable for 90 LPM at 24 Mtrs head suitable for 1.5/3 HP all as directed. Makes: Kirloskar / Crompton / Texmo / CRI /KSB/Lubi/ PSG/ ARYEN VARSHA /Falcon/Prithvi |
| 127 | Supply & Fix20 mm Nylon rope grit clamping both side all as directed by the Engineer-in-Charge. |
| 128 | Taking down the the unserviceable monoblock open/ submersible Pump Set/ sewage pump set alongwith delivery pipes carefully from the Water sump /Sewage sump of capacity 1.5 HP upto 3 HP, 3 Phase and transport to workshop for repairs and after carryout the necessary repairs/rewinding etc…, and duly re-lowering the same after repairs all as directed by the Engineer-in-Charge.Note:-1.Any repairs including servicing with minor spares deems to be included in the quoted rate. 2. Re-winding including bearings & bushes with complete servicing will be measured and paid separately. |
| 129 | Rewinding of 1.5 HP upto 3 H.P,three phase monoblock open/ submersiblepump set motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material including servicing of impellers, shafts and replacement of bearings & bushes etc..,and testing etc. as required make it in perfect working condition. |
| 130 | Taking down the the unserviceable Submersible Pump Set alongwith Column pipes carefully from the Bore well of capacity 5 HP upto 7.5 HP, 3 Phase and transport to workshop for repairs and after carryout the necessary repairs/rewinding etc…, and duly re-lowering the same after repairs all as directed by the Engineer-in-Charge.Note:-1.Any repairs including servicing with minor spares deems to be included in the quoted rate. 2. Re-winding including bearings & bushes with complete servicing will be measured and paid separately. |
| 131 | Rewinding & Servicing ofSubmersible Pump Set 5 HP upto 7.5 H.P three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of copper wound rewinding including servicing of impellers, shafts and replacement of bearings & bushesetc.., andas required make it in perfect working condition all as directed by the Engineer-in-Charge. |
| 132 | Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with \"E\" class insulation material including replacement of 2 Nos ball bearings of size 6201 &6203 and making connections etc. as required. (New model ceiling fan) |
| 133 | Servicing & Overhauling including greasing and Providing and Replacement of ball bearing of ceiling fan, table fan, pedestal fan, exhaust fan irrespective to the size of fan including replacement of ball bearing of size 6201,6202,6203 &6204 all as required at site . (NBC/ SKF) |
| 134 | Rewinding of Heavy-duty Exhaust fan motor of size upto 300/450 mm sweep including all necessary material, The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with \"E\" class insulation material and making connections etc. as required. |
| 135 | Supply and fixing of 230V/ 275V, 50Hz rating of 20-60 micro farad.Starting capacitor |
| 136 | Supply and fixing of 230V/ 275V, 50Hz rating of 80-150 micro farad.Starting capacitor |
| 137 | Supply and fixing of 230V/ 275V, 50Hz rating of 2.5/3.15 micro farad.Starting capacitor |
| 138 | Supplyandfixing Supply and fixing of water drain pipe line (1” PVC Pipe) 25 mm including all fixing arrangements all as directed. |
| 139 | Supplyandfixing Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines |
| 140 | Supply and Laying of 5/8\" and 3/8\" copper pipe (extra beyond 3 meters suplied with AC Unit) |
| 141 | Supply and Laying of 7/8\" copper pipe (extra beyond 3 meters suplied with AC Unit) |
| 142 | Supply and fixing of MS stand for fixing outdoor unit |
| 143 | Air filter suitable for 1/1.50/2 Ton Split A.C. UnitP.V.C. / NYLON if required at site all as directed by the Engr-in-Charge |
| 144 | Repairs and Installation of existing PCB in1.5 /2.0 Ton Split A.C/ cassette Unitif required at site all as directed by the Engr-in-Charge |
| 145 | Servicing/Overhauling the Split type/Cassette type 1.5/2.0 Ton AC unit by taking down the indoor and outdoor units by pumpdown the refrigerent gas & Overhauling and servicing the Split type 1/1.5/2.0 Ton AC unit by Cleaning through the water jet pump with condenser cooling Coil etc., by blower and oiling the Fan Motor for the indoor and outdoor units and Cleaning all parts and putting the machine in working condition and charging the refrigeranet gas if required basis only at site all as directed by the Engr-in-Charge.(Note :1. If requirement of refrigerent gas in essential basis only will be measured and paid under separate item. ie.for methodologyby weighing the gas cylinder before and after charging for how much gas have been charged as well as with the desired pressue.2. Otherwise servicing only accounted for this item). |
| 146 | Supply & Charging Refrigerent gas R-22/R-134 a |
| 147 | Fabrication, Transportation and supply of 1.0 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. (The design should be approved from field Engineers) including MS flat iron pole brackets with nuts&bolts and painting etc.., all as required at site. |
| 148 | Supply and fixing of 12V 180 AH SMF battery with 3 years warranty, including wire leads, connections etc complete.Makes:Amaran or equivallent make of Quanta / Racket / Exide. |
| 149 | Supplyandfixing 6 Metre Length Single Bracket Pole with Base Plate (250 x250 x6mm)76.10mm OD x 3.65mm Thick x 6000mm Length |
| 150 | Supplyandfixing 6 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length |
| 151 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. Note :-1.Eearth electrode & GI protection pipe, earth links & nuts & bolts required at site are deems to be included in the rate quoted. |
| 152 | Earthing with G.I. earth plate 600mmx600mmx6 mm including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and all as directed by the Engr-in-Charge. Note :-1.Eearth electrode & GI protection pipe, earth links & nuts & bolts required at site are deems to be included in the rate quoted. |
| 153 | Supplying and laying 25x5mm thick GI earth strip at 0.50 meter below ground level as searth electrode, including connection/terminating with nut, bolt, spring, washer etc as required with 2 sets of GI nut bolt & spring washer spaced at 50 mm and all as directed by the Engr-in-Charge. |
| 154 | Supply and fixing of DOL Starter in sheet steel enclosure type MN/ML, AC , 3 Phase, 415 Volts, 50 Hz with Vott meter & Ammeter suitable forUpto 7.5 HP Motor all as required at site and as directed by the Engr-in-Charge. Make:Crompton 9-14 Amps or equivallent make of Havells/L&T |
| 155 | Supply and fixing of DOL Starter in sheet steel enclosure type of contractor rating 16 Amps, AC , 3 Phase, 415 Volts, 50 Hz with shields motors from overloads, short circuits, and faults etc.., suitable forUpto 7.5 HP Motor all as required at site and as directed by the Engr-in-Charge. Make:Havells or equivallent make of Crompton/L&T |
| 156 | Supply and Fix Outdoor type Street light Feeder Pillar Box Panel of size not less than 11 CMx15.3CMx5 CM, suitable for 3 phase, max load 12 KW, MCB Rating 63 Amps TPN, Timer Astronomical, Product code-IHXTS0912A, Make-Havells or equivallent make of CG/Schneider/ legrand all as specified and as directed by the Engineer-in-Charge.Note:- The cost deems to be inclusive of necessary Pillar made up of brick masonary with cement plastering work all as directed at site. |
| 157 | Supply & Fix rubber gasket 3 mm thick |
| 158 | Cotton Waste/ Cleaning cloth |
| 159 | Supply & Fix 3 Pole Power Contactor of of any Make & Type all as directed and as specified. |
| 160 | Supply & Fix Spare Contact kit suitable for Power contactor\"s of any Make & Type all as directed and as specified. |
| 161 | Supply & Fix thermal Over Load Relay of capacity & range 9-45 Amps of any Make & Type all as directed and as specified. |
| 162 | Supply & Fix Spare coil of any make and type all as directed and as specified. |
| 163 | Supply, installation, testing and commissioning of Single Phase Preventer suitable for 3-phase starter panel, designed to protect motor against single phasing, phase reversal and phase unbalance. The device shall operate on 415 V, 50 Hz, automatically disconnecting the motor starter under fault condition and allowing restart only under healthy phase sequence. The unit shall be panel-mounting type with LED indication, suitable for continuous duty, complete with necessary wiring, connections, fixing arrangements, accessories and as directed by engineer In-charge.Make : Minilec / L&T / Siemens / ABB |
| 164 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 165 | Supply and fixing of stored pressure CO2 (Carbandioxide) Type Fire Extinguisher of 4.5 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 166 | Refilling-6 Kg ABC Stored Pressure type Fire Extinguisher IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge |
| 167 | Refilling- 4.5Kg CO2type Fire Extinguisher as per IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge |
| 168 | Supply & Fix MS/GI perforated cable tray painted with powder ocating of size 150x50x1.6 mm including connector, Tee and bend etc..,all as directed by the Engineer-in-Charge. |
| 169 | Supply & Laying HDPE pipe of size 63 mm including all fittings and all as required at site and all as directed by the Engineer-in-Charge. |
| 170 | Material & Labour for Copper Earth elctrode of size 4 mm dia |
| 171 | Material & Labour for 15 MM GI Pipe Medium Grade for protection of earth electrodes. |
| 172 | Material & Labour for 40 MM GI Pipe Medium Grade for cable protection under the road etc all as directed. |
| 173 | Supply & fixing of LED Driver as per IS 15885 (Part 2 / Sec13)..2012including transportationwith input line voltage 120V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12/15/18/20/22 W LED indoor luminaire, with 2 Years Warranty.Makes: As per list of recommended brands. |
| 174 | Supply & fixing of LED Driver as per IS 15885 (Part 2 / Sec13)..2012including transportationwith input line voltage 120V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 36/40 W LED indoor luminaire, with 2 Years Warranty.Makes: As per list of recommended brands. |
| 175 | Supplyandfixing Surface Box [Supplyandfixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 4 Module |
| 176 | Supplyandfixing Surface Box [Supplyandfixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 8 Module |
| 177 | Supplyandfixing Surface Box [Supplyandfixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END] 8 (2 row x 4) Module |
| 178 | LED Post top lantrne/ Gate light fitting of 25 Watts, with 4000K colour temperature, IP 65 with LED Lamp all as directed by theEngineer-in-Charge. Make-Havells Mini Ruby Post Top LED Lamp or equivallent make of Philips/CG |
| 179 | LED Bollard light fitting of 25 Watts, with 4000K colour temperature, IP 65 with LED Lamp all as directed by the Engineer-in-Charge. Make-Havells or equivallent make of Philips/CG |
| 180 | Suppy and Fix Timer Switch 24 Hours programmable switching time |
| 181 | Power Contactor 3 phase 4 pole, 63 Amps |
| 182 | 63A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 183 | 100 A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 184 | 125 A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 185 | 200A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 186 | 250A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 187 | Supplyandfixing Water Tight Bulk Head Fitting suitable for 9-15 Watts LED Lamp with Guard Heavy Type |
| 188 | Carryout routine maintenance and servicing of LT. Cubical panel board having approximately 15 to 22 Nos of switches cleaning with power blower and servicing the contacts with CTC Spray, tightening the connection ofincoming and outgoing cables, and checking the operating mechanism for smooth functioning of switches and putting them in smooth working condition. |
| 189 | Painting to Electrical LT Panels:The work includes complete surface preparation of LT panels by removing rust, dust, grease and loose paint; application of one coat of approved red-oxide primer and two coats of synthetic enamel paint of approved make/shade; repainting of feeder names, danger sign, phase marking; masking/protection of live components; and handing over with a uniform smooth finish. All labour, tools, scaffolding, consumables, and safety precautions included.(Asian/Berger/Nerolac or equivalent) |
| 190 | Painting of 6.0 m street light pole (MS tubular/swaged type) including thorough surface cleaning with wire brush/emery paper to remove rust, dust & loose paint, application of one coat approved anticorrosive metal primer and two coats of approved synthetic enamel paint of specified shade, including thinning, provision of brushes/consumables, and all lead, scaffolding/ladder work, complete as directed by Engineer-in-Charge. |
| 191 | Carrying out minor welding works on existing street light poles/pipes/structure including surface preparation by cutting/grinding, welding with suitable electrodes (E6013 or equivalent) using portable welding set, rectification of cracks, base plate, brackets/fittings as required, finishing the welded portion with grinding, application of primer, and one coat of synthetic enamel paint of approved shade, complete as directed by the Engineer-in-Charge. |
| 192 | Testing of earth pit including measurement of earth resistance using digital 3/4-wire earth resistance tester (fall-of-potential method or clamp/three-wire as applicable), providing site test certificate, signed by authorized technician, and submission of soft/hard copy report, complete as directed by Engineer-in-Charge. |
| 193 | Supply and Fixing of 240/220 V, Red/yellow/Green colour LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required (Set of three) |
| 194 | Supply and Fixing of 240/220 V,Blue colour LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required |
| 195 | Supply and fixing of push button actuators and integral contact block ofdia. 22.5 mm Luminous type including making connection etc. as required.Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL |
| 196 | Supply and fixing of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle |
| 197 | Numbering of ceiling fan/ exhaust fan/ LED fittings/streetlights, Panels/DBs/Pumps etc...as required. ( paint and labour charges included) |
| 198 | Quarterly service / Preventive maintenance of 100 KVA DG set, including checking and cleaning of air filter, fuel filter, oil filter, radiator, battery terminals, belts, hoses, and all electrical connections; checking of engine oil level, coolant, fuel system, and control panel parameters; testing of starting system, load test, and overall health check of DG set; submission of service report of OEM or OEM Authorized etc..complete as directed by the Engineer-in-charge. |
| 199 | Carrying out B-Check service (Material & Labour) for 100 KVA Diesel Generator set, including replacement of engine lube oil, oil filter, fuel filter, cleaning of air filter, checking and tightening of belts, hoses, battery terminals, radiator cleaning, inspection of alternator, checking of electrical connections, calibration of parameters, top-up of coolant, Distilled water, checking of safety shutdowns, trial run of generator under load, and submission of service report, complete all as directed by the Engineer-in-charge. |
| 200 | Old unserviceable C/fans/ Wall fans/exhaust fan/ pedastal fans off sizes obtained from BOQ Items. |
| 201 | Old unserviceable Batteries off sizes obtained from BOQ Item. |
| 202 | Aluminium Scrap obtained from Old unserviceable aluminium wirings, lugs and aluminium Cables & connected items . |
| 203 | Iron Scrap obtained from Old unserviceable items from BOQ Items connected with iron scraps. |
| 204 | Copper Scrap obtained from Old unserviceable items from BOQ Items. |
| 205 | PVC Scraps obtained from Old unserviceable items from BOQ Items. |
| 206 | Old unserviceable light fittings (all types) off sizes obtained from BOQ Items. |
| 207 | Old unserviceable street light fittings (all types) off sizes obtained from BOQ Items. |
| 208 | Old unserviceable MCB\"s (all types) off sizes obtained from BOQ Items. |
| 209 | Old unserviceable MCB\"s DB\"s (all types) off sizes obtained from BOQ Items. |
| 210 | Credit for dismantled materials Electrical Switches/Sockets (Various) |