| 1 | Engaging of 1 No \"C\" Licence Holder (Supervisor)of day to day maintenance of Electricalmaintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, HT/LT Panels , MCBs, MCB DBs, MCCBs, SFUs, FSUs etc., andall types of fans / light fittings,UG cables etc., complete all as directed by the Engineer-in-charge. ( 01 No.) (Qualification: Diploma in Electrical Engineering with 10 years related experience/ITI with 12 years or experience (supervisory) in maintenance job) Note:-1.He is the responsible for maintain the day to day complaint Register, Preperation of Duty Roster, Material Consumption Register, Log Book/Log sheets and to up keep the neat & Tidy of installations with installed plants & machinaries as per the direction of Engineer-in-Charge 2.He is the responsible for HT Metering cubicle to monitor & maintain all parameter readings.3.He is the responsible for timely calibration of HT VCB\"s, LT ACB\"s/MCCBs and Earth Fault Relays and Over Current Relays.4.He is the responsible for HT Panels, Transformers, ACBs, MCCBs,APFC Panels with connected Capacitor Banks,Power Contactors & Relays, Up Keep & maintain records for earth results in the HT & LT installations as per the direction of Engr-in-Charge.5.During Main EB supply failure to monitor the running of stand by DG Sets and maintain the Plant Running Record Book with all parameters.6.To maintain the EB Shutdown Register & obtain the necessary signature from EB authorities . (It should be talley with Stand By DG Set PRRB) |
| 2 | Engaging an Electrician Cum DG Operator cum Panel opearation for day to day operation of DG sets, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andday to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, UG cables, DG Setetc complete all as directed by the Engineer-in-charge.; andalso Preventive maintenance of above mentioned equipment as per standerd check list and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge.. Electrician Skilled (ITI Certificate with 3 Years Experience)- 4 Nos |
| 3 | Electrician Cum DG Operator-1 (as detailed above) |
| 4 | Electrician Cum DG Operator-2 (as detailed above) |
| 5 | Electrician Cum DG Operator-3 (as detailed above) |
| 6 | Electrician Cum DG Operator-4 (as detailed above) |
| 7 | Engaging an Electrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, UG cables, DG Setetc complete all as directed by the Engineer-in-charge. (1 nos Electrician- Skilled)(ITI Certificate with 3 Years Experience). |
| 8 | Engaging Lift operator cum Electrician for day to day ( 1 shift /day in Gen Shift)Lift Operator is responsible for the safe operation of elevators/ lifts.Checking of lift condition, to carry out rescue operation and following up with OEM for PM & Break down calls etc.., to make it in proper working condition etc.., Here are some common duties and tasks associated with this role of Lift Operator is to assist passengers in safely while loading and unloading and to ensure the safety and comfort of passengers during lift operations.Maintenance: Operators maintain the lift area, keeping it clean and organized. They also implement emergency procedures when necessary.Evacuation: In case of disabled lifts or emergencies, Lift Operators evacuate passengers as per established protocols.Qualification of Lift Operator: ITI Electrician with 1Year experience Operation & maintain of Lifts.- 1 Nos (01 Lift Operator cum Electrician For ESIH Salem) |
| 9 | Helper toElectrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, in routine operations and preventive/corrective maintenance activities likeAssisting in electrical fault isolation and repair, Supporting maintenance of LTpanels, control wiring, MCCs, etc.Handling tools, material shifting, and cleaning of electrical panels,and Coordinating during shutdowns, emergency operations, and safety drills complete all as directed by the Engineer-in-charge. ( 1 nos Un Skilled) |
| 10 | Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 11 | Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 12 | Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 13 | Supply of 25 mm iron staples/ saddles/ screws |
| 14 | Supply of 25 mm dia. ISI marked, PVC conduit |
| 15 | Supply of 25 mm PVC bends |
| 16 | Supply of 25 mm PVC couplers |
| 17 | Supply of Modular GI box for 4module |
| 18 | Supply of Modular GI box for 6 module |
| 19 | Supply of Modular GI box for 8 module |
| 20 | Supply of Modular GI box for 12 module |
| 21 | Supply of S.P. 5/6 amps, one way modular switch, ISI marked |
| 22 | Supply of S.P. 15/16 amps, one way modular switch, ISI marked |
| 23 | Supply of 3 pin 5/6 amps modular socket outlet, ISI marked |
| 24 | 6 pin 15/16 amps modular socket outlet, ISI marked |
| 25 | Supply of Stepped type Modular Fan regulator (2-module) |
| 26 | Supply of Modular blanking plate |
| 27 | Supply of Modular base & cover plate for 3 module |
| 28 | Supply of Modular base & cover plate for 6module |
| 29 | Supply of Modular base & cover plate for 8module |
| 30 | Supply of SP 5/6A one-way piano switch, ISI marked |
| 31 | Supply of SP 15/16A one-way piano switch, ISI marked |
| 32 | Supply of 3 pin 5/6A piano socket outlet, ISI marked |
| 33 | Supply of 6 pin 15/16A & 5/6A piano socket outlet |
| 34 | Supply of Bell push, piano type |
| 35 | Supply of Call bell/buzzer, single phase |
| 36 | Supply of PVC Batten/Angle Holder |
| 37 | Supply of 6 amps. to 32 amps. ratings , SP MCB, \"C\" curve, 10 KA breaking capacity |
| 38 | Supply of Single pole, Blanking plate |
| 39 | Supply of 63 amps., 4 pole isolator |
| 40 | Supply of 63 A, rating, 2 pole RCCB, 30mA |
| 41 | Supply of 63 amps. rating, 4 pole RCCB, 30mA |
| 42 | Supply of 20 amps. SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure |
| 43 | Supply of Aluminium lugs for up to 50 sq. mm cable |
| 44 | Supply of Aluminium lugs for70 sq.mm to120 sq. mm cable |
| 45 | Supply of Aluminium lugs for150 Sq.mm 240 sq. mm cable |
| 46 | Supply of GI saddles 19mm x 0.55mm for conduit |
| 47 | Supply of 200 mm X 150 mm M.V. danger notice plate |
| 48 | Supply of Coke |
| 49 | Supply of Salt |
| 50 | Supplying of 18- 22 watt LED surface mounted Batten light Four feet (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.Powdercoateddiecast/Extruded aluminium Body (Thickness > 1.20 mm) Make:Havells/Philips/Crompton/Wipro |
| 51 | Supply of 7W / 9W LED Bulb Make:Havells/Philips /Crompton /Wipro |
| 52 | Supply of 15W LED Bulb Make:Havells/Philips/Crompton/Wipro |
| 53 | Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor 1200mm,BEE 5 star rating, service value≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 54 | Supply AC Exhaust Fan 300mm (12”) Sweep (Light Duty) |
| 55 | Supplyof 300mm Sweep WALL MOUNTING FAN |
| 56 | SupplySurface Box [SupplySURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 3 Module |
| 57 | SupplySurface Box [SupplySURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 6 Module |
| 58 | Supply25A Modular PVC Box type Wall Socket with C-20A/C-25ASingle Pole MCB protected AC socket with Plug TopMake : Havells/orbit/anchor/MK/Legrand |
| 59 | Supply of PVC /cotton tape Role (10 Mtrs) |
| 60 | Supply of Empire tape Role (10 Mtrs) |
| 61 | Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi) |
| 62 | Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals etc., complete (sizes in mm).Make : Hensel/Sadhrish |
| 63 | Supply of 6A, flush type Neon Indicator |
| 64 | Supply of Running capacitor 2.5/3.15/4.0/6.0 μF |
| 65 | Supply of63A, 415V Porcelain Rewireable Fuse UnitMakes: C&S/Standard/HPL/ Sputnik /Million / GoldMedal / GM/Benlo/Anchor |
| 66 | Supply of 100A, 415V Porcelain Rewireable Fuse UnitMakes: C&S/Standard/HPL/ Sputnik /Million / GoldMedal / GM/Benlo/Anchor |
| 67 | Supply of 200A, 415VPorcelainFuse Unitwith Extensionwith extension stripMakes: C&S/Standard/HPL/ Sputnik /Million / GoldMedal / GM/Benlo/Anchor |
| 68 | Supply of 300A, 415VPorcelainFuse Unitwith Extensionwith extension stripMakes: C&S/Standard/HPL/ Sputnik /Million / GoldMedal / GM/Benlo/Anchor |
| 69 | Supply of 6 SWG Copper Earth Wire (0.16 kg/m) |
| 70 | Supply of 8 SWG Copper Earth Wire (0.1155 kg/m) |
| 71 | Supply of 10 SWG Copper Earth Wire (0.075 kg/m) |
| 72 | Supply of 12 Way Neutral Link |
| 73 | M&L Wiring for light /fan/exhaust fan /call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core multi stranded cable in surface/recessed medium class PVC conduit, with modular Switch, Modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conduuctor single core multi stranded cable etc., all as required and as directed.Note for Item S.No.1 & 2:- 1.GI Modular box, Modular Plate & Modular switches are included in the unit rate. |
| 74 | M&L Wiring for twin control light point with 1.5 sqmm FRLS PVC insulated copper conductor single core multi stranded cable in surface/recessed medium class PVC conduit, with modular Switch, Modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conduuctor single core multi stranded cable etc., all as required and as directed. |
| 75 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 2x2.5 Sqmm+1x2.5 Sqmm earth wire. |
| 76 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 2x4 Sqmm+1x4 Sqmm earth wire. |
| 77 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 4x4 Sqmm+2x4 Sqmm earth wire. |
| 78 | M&L for Circuit/Submain wiring along with earth wire with following sizes of PVC insulated FRLS copper conductor , single core and single strand cable in surface/recessed PVC conduit all as directed and required 4x6 Sqmm+2x6 Sqmm earth wire. |
| 79 | M&L for Earthing with GI Earth pipe 4.5 mtr long, 40 mm dia including acessories and providing masonary enclosure with cover plate and locking arrangements and water pipe of 2.7 metre long etc, with earth electrode, charcoal and salt all as specified and as directed by the Engr-in- Charge. |
| 80 | S&F including providing and laying earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia GI pipe from earth electrode including crimpting with copper thimble excavation and refilling as required at site on surface or in recess all as specified and as directed by the Engr-in- Charge. |
| 81 | S&F 2 module GI Box alongwith modular base & cover plate for modular switch/socket in surface/recess etc.., as required at site all as directed by the Engr-in-Charge. (for Geyser) |
| 82 | S&F 3 module GI Box alongwith modular base & cover plate for modular switch/socket in surface/recess etc.., as required at site all as directed by the Engr-in-Charge. (for 5 Amps S/S and 15 Amps S/S) |
| 83 | S&F 4 module GI Box alongwith modular base & cover plate for modular switch/socket in surface/recess etc.., as required at site all as directed by the Engr-in-Charge. (for UPS) |
| 84 | S&F MCB DB, SPN 8 Ways Double Doorwith connections, testing and commissioning etc., as required and as directed. |
| 85 | S&F MCB DB, TPN 4 Ways (4+12) Double Doorwith connections, testing and commissioning etc., as required and as directed. |
| 86 | S&F MCB DB, TPN 8 Ways (4+24) Double Doorwith connections, testing and commissioning etc., as required and as directed. |
| 87 | S&F MCB SP 6 to 32 Amps, \"C\" curve, 10 KA breaking capacity. |
| 88 | S&F MCB SPN 6 to 32 Amps, \"C\" curve, 10 KA breaking capacity. |
| 89 | S&F MCB Isolator 40 Amps, 4 Pole, 415 Volts in the existing MCB DB complete with connections, testing and commissioning etc. as required and all as directed. |
| 90 | S&F RCCB 63 Amps, 4 Pole, 415 Volts, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required and all as directed. |
| 91 | S&F MCB Isolator 63 Amps, 4 Pole, 415 Volts in the existing MCB DB complete with connections, testing and commissioning etc. as required and all as directed. |
| 92 | LED Streetlight fixture 36 watt, powdercoatedpressurediecastaluminumbody(Systemlumen efficacy >135 lm/Watt) Supplying,installation,Testing&Commissioningof 50 watt StreetlightLED fixture. |
| 93 | LED Streetlight fixture 50 watt, powdercoatedpressurediecastaluminumbody(Systemlumen efficacy >135 lm/Watt) Supplying,installation,Testing&Commissioningof 50 watt StreetlightLED fixture. |
| 94 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering with suitable HDPEPipe for UG cable laying and refilling the trench etc as required. above 35 sq.mm and upto 95 sq.mm |
| 95 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 96 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 97 | Supply and transportation of 16 Sq mm X 4 core coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLES Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 98 | Supply and transportation of 25 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 99 | Supply and transportation of 35 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 100 | Supply and transportation of 50 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 101 | Supply and transportation of 70 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 102 | Supply and transportation of 95 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 103 | Supply & Fixing of D.O.L. Starter Panel, 415 V, 3-phase, 50 Hz, enclosed, with no-volt coil and thermal overload protection, single-phase preventer, voltmeter, ammeter and indication lamps, complete with all internal wiring, fuses/isolator, terminal blocks, glands, earthing, testing & commissioning, suitable for 5 to 7.5 HP motor. |
| 104 | Supply and fixing of 4.0 KVA 1-phase, automatic Electronic Voltage Stabilizer.Makes:V-Guard / Real Guard / Uni Stab / ITL |
| 105 | Rewinding of up to 5.0 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material and testing etc. as required make it in perfect working condition. |
| 106 | Rewinding of upto 7.5 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material and testing etc. as required make it in perfect working condition. |
| 107 | Taking down the the unserviceable monoblock pump set alongwith delivery pipes carefully from the sump of capacity 1.5 HP to 7.5 HP, 3 Phase and transport to workshop for repairs and after carryout the necessary repairs etc…, and duly re-lowering the same after repairs all as directed by the Engineer-in-Charge. |
| 108 | Supply and fixing of 230V/ 275V, 50Hz rating of 20-60 micro farad.Starting capacitor |
| 109 | Supply and fixing of 230V/ 275V, 50Hz rating of 15-36 micro farad.Running capacitor |
| 110 | Supplyandfixing Supply and filling of R-22 Refrigerant Gas |
| 111 | Supply and fixing of 12V 180 AH SMF battery with 3 years (36 Months) warranty, including wire leads, connections etc complete.Makes: Quanta / Racket / Exide. |
| 112 | Painting of 6.0 m street light pole (MS tubular/swaged type) including thorough surface cleaning with wire brush/emery paper to remove rust, dust & loose paint, application of one coat approved anticorrosive metal primer and two coats of approved synthetic enamel paint of specified shade, including thinning, provision of brushes/consumables, and all lead, scaffolding/ladder work, complete as directed by Engineer-in-Charge. |
| 113 | Carrying out minor welding works on existing street light poles/pipes/structure including surface preparation by cutting/grinding, welding with suitable electrodes (E6013 or equivalent) using portable welding set, rectification of cracks, base plate, brackets/fittings as required, finishing the welded portion with grinding, application of primer, and one coat of synthetic enamel paint of approved shade, complete as directed by the Engineer-in-Charge. |
| 114 | Testing of earth pit including measurement of earth resistance using digital 3/4-wire earth resistance tester (fall-of-potential method or clamp/three-wire as applicable), providing site test certificate, signed by authorized technician, and submission of soft/hard copy report, complete as directed by Engineer-in-Charge. |
| 115 | Supply and fixing of First Aid Box complete with all First Aid Medicines |
| 116 | Supply and fixing of Shock Treatment Chart fixed in glass frame |
| 117 | Supply and fixing of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle |
| 118 | Supply and fixing of Metallic Danger Board as required by the Electrical Authorities |
| 119 | Refilling of 4.5 kg CO₂ type Fire Extinguisher, including evacuation of existing gas, cleaning and inspection of cylinder, refilling with CO₂ gas confirming to IS 15683, pressure testing, fixing of discharge hose and horn, re-sealing, labeling, and affixing inspection tag complete as directed by Engineer-in-Charge. |
| 120 | Refilling of 6 kg ABC (Dry Chemical Powder) type Fire Extinguisher, including emptying of old powder, internal cleaning, refilling with ABC powder confirming to IS 14609, re-pressurizing with nitrogen, checking of pressure gauge, sealing, and affixing of refill/service tag complete as directed by Engineer-in-Charge. |
| 121 | Refilling of 2 kg ABC (Dry Chemical Powder) type Fire Extinguisher, including emptying of old powder, internal cleaning, refilling with ABC powder confirming to IS 14609, re-pressurizing with nitrogen, checking of pressure gauge, sealing, and affixing of refill/service tag complete as directed by Engineer-in-Charge. |
| 122 | Numbering of ceiling fan/ exhaust fan/ LED fittings/streetlights, Panels/DBs/Pumps etc...as required. ( paint and labour charges included) |
| 123 | Supply & fixing of Wire mesh 20 gauge |
| 124 | Supply and fixing of Weld mesh for existing Lovers |
| 125 | Supply & Making heat shrinkable outdoor straight through joint for 3.5core x 25/35/50Sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 126 | Supply & Making heat shrinkable outdoor straight through joint for 3.5 core × 70/95/120 Sq.mm sizeof PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 127 | Supply & Making heat shrinkable outdoor straight through joint for 4 core × 6/10/16 Sq.mm size of PVC/ XLPE insulated aluminum conductor cable of 1.1 KV grade including cost of ferrules compound, sleeves and other jointing materials etc. as required. |
| 128 | Rewinding of 900/1200 mm sweep ceiling fan motor (starting and running winding) including allnecessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameledwire with \"E\" class insulation material and making connections etc. as required. (New model ceiling fan) |
| 129 | Providing and Replacement of ball bearing of ceiling/exhaust fan as required. (NBC/ SKF) |
| 130 | Providing and Replacement of Gun metal bush of ceiling/ exhaust/cooler fan/ as required |
| 131 | Spray painting of ceiling fan of size 900/1200/ 1400 mm with two coats of white/ brown enameled paint after cleaning with sandpaper. Filling etc. as required. |
| 132 | Supply and charging of fresh refrigerant and testing ofperformance of air conditioner 1.5 TR Window/ Split A.C |
| 133 | Installation of Split Air Conditioners |
| 134 | Removing existing Split AC /Casette Type AC without damaging copper pipe |
| 135 | Repairs and Installation of existing PCB in 1.0 / 1.5 / 2.0 Ton Split A.C. Unit |
| 136 | Overhauling and servicing the Split type 1.5/2.0 Ton A.C. Machine by Cleaning the condenser cooling Coil etc., by blower and oiling the Fan Motor and Cleaning all parts and putting the machine in working condition. |
| 137 | Fabrication, Transportation, Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting on street light pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required POLE BRACKETS |
| 138 | Fabrication, Transportation and supplyand Fixing of 1.5 Mtr length Double Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe with flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required POLE BRACKETS |
| 139 | Supply and Fixing of Phase Changeover in SS Enclosure ( 3 phase indicators & 40A Cam operated Rotary swiches |
| 140 | Supply and Fixing of Phase Changeover in SS Enclosure ( including 3 phase indicators & 63 A Cam operated Rotary swiches for 3 phases) |
| 141 | Supply and fixing of 63 mm diaHDPE pipe for UG XLPE Cabling etc.. As required |
| 142 | Supply and fixing of 38mm/50mm mm diaHDPE pipe for UG XLPE Cabling etc.. As required |
| 143 | Supply and delivery of diesel for 100 KVA DG set at Vellore ESI Hospital, including cost of diesel, loading, unloading, transportation, carriage to site, and filling into the DG set complete as directed by engineer in charge. |
| 144 | Quarterly service / Preventive maintenance of 100 KVA DG set, including checking and cleaning of air filter, fuel filter, oil filter, radiator, battery terminals, belts, hoses, and all electrical connections; checking of engine oil level, coolant, fuel system, and control panel parameters; testing of starting system, load test, and overall health check of DG set; submission of service report of OEM or OEM Authorized etc..complete as directed by engineer in charge. |
| 145 | Carrying out B-Check service for 100 KVA Diesel Generator set, including replacement of engine lube oil, oil filter, fuel filter, cleaning of air filter, checking and tightening of belts, hoses, battery terminals, radiator cleaning, inspection of alternator, checking of electrical connections, calibration of parameters, top-up of coolant, checking of safety shutdowns, trial run of generator under load, and submission of service report, complete. |
| 146 | Charges for providing / conducting complete fire audit Including submission of fire audit report for the whole premises by Certified fire safety auditors / NABH-approved auditors / State Fire Dept (NOC) / Third-party expert agencies. |
| 147 | Supply and fixing of escape signage boards made of rigid photoluminescent (glow-in-the-dark) sheet, with high-intensity luminous properties, including all accessories, fixing materials, supports, and as per approved sample and site requirement. |
| 148 | Supplying and fixing of “FIRE ASSEMBLY POINT” signage board of size 400×300 mm made of 3 mm rigid PVC/FRP with reflective/photoluminescent printing, including GI pipe/wall mounting, screws, clamps, foundation (if required), labour, tools and transportation, complete as per direction of Engineer-in-Charge. |
| 149 | Supply and fixing of 4 Nos. of 9-L capacity round-bottom fire sand buckets, enamel painted (white inside/red outside) with “FIRE” marking, including sand and mounting bracket. |
| 150 | Supply and fixing of MS angle-fabricated fire bucket stand suitable for 4 buckets as per fire officer standards. |
| 151 | Supply and fixing of ABC stored pressure squeeze grip type fire extinguishers, 9 kg capacity, IS:15683 : 2006, filled with ABC Mono Ammonium Phosphate base powder-90 complete with discharge hose and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure Gauge, which work effectively on all class of fires (A, B, C & Electrical fires) with 5 years warranty Including transportation, all taxes and all labour charges etc complete. |
| 152 | Supply and Fixing of Phase Changeover in SS Enclosure ( including 3 phase indicators & 250 A Cam operated Rotary swiches for 3 phases) |
| 153 | Providing Earthing with GI Earth pipe 4.5 mtr long, 40 mm dia including acessories and providing masonary enclosure with cover plate and locking arrangements and water pipe of 2.7 metre long etc, with earth electrode, charcoal and salt all as specified and as directed by the Engr-in- Charge. |
| 154 | Providing and laying earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia GI pipe from earth electrode including crimpting with copper thimble excavation and refilling as required at site on surface or in recess all as specified and as directed by the Engr-in- Charge. |
| 155 | 63A, TPN Switch disconnector Fuse Unit (Panel Mounted Type) with ISI Marked HRC Fuses and fixing bots & nuts etc.., |
| 156 | LED Post top lantrne/ Gate light fitting of 25 Watts, with 4000K colour temperature, IP 65 with LED Lamp Make-Havells Mini Ruby Post Top LED Lamp or equivallent make of Philips/CG |
| 157 | Painting to Electrical LT Panels:The work includes complete surface preparation of LT panels by removing rust, dust, grease and loose paint; application of one coat of approved red-oxide primer and two coats of synthetic enamel paint of approved make/shade; repainting of feeder names, danger sign, phase marking; masking/protection of live components; and handing over with a uniform smooth finish. All labour, tools, scaffolding, consumables, and safety precautions included.(Asian/Berger/Nerolac or equivalent) |
| 158 | Routine maintenance of 315 KVA transformer, including testing of insulation resistance, oil breakdown strength. Reconditioning / replacement of silica zel,cleaning of transformer and topping upto oil level ifrequired (extra cost will be paid for oil). |
| 159 | Testing of Transformer oil for dielectric breakdown strength. |
| 160 | Supply of new and tested transformer oil as per IS-335 - 1972 (per Ltr) |
| 161 | Filtration of transformer oil as per ISS specifications filters to dielectric strength above 40KV …….at site. (Per Ltr) |
| 162 | Painting to 315 KVA transformer with 2 coats Zinc chromate red oxide duly scraping existing paint followed by 2 coats of hammer ton grey paint etc., complete. |
| 163 | Credit for dismantled materials old Dg set battery |
| 164 | Credit for dismantled materials Ceiling Fan/Wall Mount Fan (Old) |
| 165 | Credit for dismantled materialsExhaust Fan (Old) |
| 166 | Credit for dismantled materialsStreet Light Fitting (LED/HPSV – Old) |
| 167 | Credit for dismantled materialsLED Tube Light / Panel Light (Non-working) |
| 168 | Credit for dismantled materials LED Bulb (Non-working) |
| 169 | Credit for dismantled materials CFL Fitting – 2 Pin / 4 Pin (Old) |
| 170 | Credit for dismantled materials Fluorescent Tube Fitting (Old) |
| 171 | Credit for dismantled materials Fan Capacitor (Old) |
| 172 | Credit for dismantled materials Miniature Circuit Breaker (MCB – Old) |
| 173 | Credit for dismantled materials Distribution Board (MCB Box – Old) |
| 174 | Credit for dismantled materials Electrical Switches (Various) |
| 175 | Credit for dismantled materials 5A / 15A Sockets (Old) |
| 176 | Credit for dismantled materials Call Bell / Buzzer |
| 177 | Credit for dismantled materials Old Copper Wiring (Mixed Gauge, Insulated) |
| 178 | Credit for dismantled materials Aluminium Wiring (Scrap) |
| 179 | Credit for dismantled materials PVC Conduits / Flexible Pipes (Scrap) |
| 180 | Credit for dismantled materials Armoured UG Cable (Aluminium Core) – Scrapped |
| 181 | Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings: obtained as old unserviceable Iron Scrap. |