| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : |
| 2 | Providing & laying of stone soling hand packed in foundation trenches i/c all carriages, loading, unloading, etc. complete job. |
| 3 | Providing and laying in position cement concrete of specified grade M-7.5 excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), i/c all carriages, loading, unloading, etc. complete job. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | Suplying and filling plinth with fine GSB under floors including watering, ramming consolidating and dressing complete, i/c all carriages, loading, unloading, etc. complete job. |
| 6 | Providing and laying in posiiton cement concrete of specified grade M-10 excluding the cost of centering and shuttering - all work upto plinth level :1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone 20 mm nominal size ) i/c all carrriages loading unloading etc complete job |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level including carriage |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor 5 level including carriage. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete includingcuring but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) including carriage |
| 10 | .Providing and laying in position cement concrete of specified grade M-15 excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c all carriages, loading, unloading, etc. complete job. |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) including carriage |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 13 | A. Foundation |
| 14 | B. Suspended floors |
| 15 | columns |
| 16 | Beams |
| 17 | Edges of slab ( under 20 cms ) |
| 18 | stairs |
| 19 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding, i/c loading, unloading, carriage all complete. Thermo mechanically treated bars |
| 20 | Providing wood work in frames of door windows clestory windows and other frame wrought framed and fixed in position with hold flat lugs or with dash fastever of required diameter and length (holdfast lugs or dash fastens shall be paid seperately 2nd class kail wood i/c all carriage complete. |
| 21 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood 35 mm |
| 22 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second kail wood 35 mm |
| 23 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Ply wood 5 ply, 9 mm thick Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type |
| 24 | Providing & fixing 4.0 mm thick glass panes (weighing not less than 10 kg/sqm) with all fixtures, all complete |
| 25 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size). |
| 26 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood 35mm Thick |
| 27 | Providing and fixing of Hardware fittings (Allys) as per approved |
| 28 | 100mm Handles |
| 29 | 150mm Handles |
| 30 | 100mm Tower Bolts |
| 31 | 150mm Tower bolts |
| 32 | Stay Hooks |
| 33 | L-Drop 8 Inch with link lock, |
| 34 | Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture. |
| 35 | Brick work class designation 75 in superstructure above plinth level upto floor five level in cement mortar 1:6 ( 1 cement: 6 coarse sand) i/c loading, unloading, carriage etc complete job |
| 36 | 15 mm thick cement plaster of 1:6 mix ( 1 cement: 6 coarse sand) on walls etc incl all carriages, complete job |
| 37 | 12 mm thick cement plaster of 1:6 mix ( 1 cement: 6 coarse sand) on walls etc incl all carriages, complete job |
| 38 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick |
| 39 | Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in- Charge. 18mm thickness |
| 40 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colors and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) including grouting the joints with white cement and matching pigments etc. Complete. Size of tile 60x60cm |
| 41 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 42 | Providing and fixing Ceramic glazed floor tiles (anti-skid) 30cmx30cm (thickness to be specified by the manufacturers) of 1st quality conforming to IS:13755 of NITCO, ORIENT, SOMANY, KAJARIA or equivalent make in color such as white, Ivory, Grey, Fume Red, Brown laid on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete |
| 43 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including finishingthe top smooth and curing complete |
| 44 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 45 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position, incld soffits, eaves boarding, stand for water storage tanks,window grills and applying a priming coat of approved steel primer incld two or more coats of approved steel paint,welded , complete job |
| 46 | Providing and fixing of color coated Hi Rib roofing incld ridges and valleys of thickness approved by EIC 0.05 mm incld cost of hooks etc incld carriage of materials to site, and including cutting to size and shape wherever required. |
| 47 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (Jaquar or Equivalent as per Make List) w.c. pan with isi marked white solid plastic seat and lid |
| 48 | Providing and fixing wash basin with C.I. brackets, 32 mm C.P. brass waste coupling of standard pattern,including suitable Pedestal, PVC connections to basin mixer, painting of fittings and brackets, cutting and making good the walls wherever required. (Jaquar or Equivalent as Per Make List) size 630x450mm |
| 49 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm |
| 50 | Providing and fixing premium wall mounted frameless mirror of superior glass (of approved quality) and of required shape and size , Rectangular shape 450x600 mm |
| 51 | Providing and fixing soil, waste and vent pipes IS 13592 & fittings (IS: 14735 ) suitable to rubber ring joints , which includes plain bends, door bends, sockets, rubber ring, jointing, junctions, clean out plug , cowls, reducers, offsets, collar, M.S holder-bat clamps, access pieces, floor traps i/c steel grating, trap of self cleansing design .etc. complete including jointing incld all fittings and fixtures, tees, bends, door tees, clamps, cowel caps,etc as directed. |
| 52 | 75 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B(Astral/Supreme/Ajay/Prince Pipes) |
| 53 | 110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B(Astral/Supreme/Ajay /prince Pipes) |
| 54 | . Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge, Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.,incld all necessary fittings and fixtures, bends, tees, nipples, etc, PN-16 pipe |
| 55 | 20mm dia OD |
| 56 | 25mm dia OD |
| 57 | External work concealed including trenching, refilling etc., PN-16 pipe , 32mm OD |
| 58 | Providing and fixing ball valve (brass) of approved quality of required dia |
| 59 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes / ball cock, with all necessary fittings and fixtures, complete job 4 Nos with 1000 litre capacity each |
| 60 | Providing and fixing C.P brass bib cock of approved quality 15mm nominal bore |
| 61 | Providing and fixing C.P. brass angle valve for basin mixer and geyser/cistern points. , 15mm nominal bore |
| 62 | Providing and fixing C.P. brass Basin Mixer 15 mm Nominal Bore .(Jaquar or Equivalent as Per Make List) |
| 63 | Providing and fixing C.P. brass Wall Mixer (Jaquar or Equivalent as Per Make List, (Jaquar or Equivalent as Per Make List) |
| 64 | Providing and fixing of Geysers of 50 ltr capacity incld necessary fittings and fixtures, PVC connections, (Jaquar or Equivalent as Per Make List) |
| 65 | Constructing brick masonry chamber/manhole with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame & hinges (light duty) 455x610 mm internal dimensions i/c padlock arrangement, fixed in 1:1.5:3 mix,, inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : |
| 66 | providing fixing of iron manhole cover with hinge and lock arrangement, over septic /soakage pit complete job |
| 67 | Consultancy services including architectutal drawing, structural drawing, soil test, dpr formulation complete job |
| 68 | Electric part |
| 69 | Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) excl. cost of conduit. |
| 70 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) excl. cost of conduit |
| 71 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent) |
| 72 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.) |
| 73 | Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent) |
| 74 | .3 pin 5A - 10A socket |
| 75 | indicator |
| 76 | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Havells/ Polycab/ Anchor/ Finolex/KEI/RR make in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit |
| 77 | Supply, installation, testing and commissioning of 12 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series. |
| 78 | Supply, installation, testing and commissioning of 1 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections. |
| 79 | Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd. |
| 80 | Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton). |
| 81 | Supply, installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100lm/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C.LM79 and LM80 test report sohould be from Govt. approved NABL lab/ Govt. of India The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. |
| 82 | Supplying and fixing of modular blanking plates on existing modular plate and switch box ,excluding modular plate as required. |
| 83 | Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excl. cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). |
| 84 | 2 x2.5 sq.mm + 1x 2.5 sq. mm earth wire |
| 85 | 2 x 6 sq.mm + 1x 6 sq. mm earth wire |
| 86 | 4 x 10 sq.mm + 2x 6 sq. mm earth wire |
| 87 | Supply and installation of 32A modular plug/socket with 32A DP MCB for Acs |
| 88 | Supply and fixing of Double door surface/ recess mounting , Vertical/ Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. i. 6 Way (4 +18) . |
| 89 | Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 90 | Supply, installation, testing and commissioning of 32 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 91 | Supply, installation, testing and commissioning of 63 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 92 | Supply, installation, testing and commissioning of 63A TP&N rating 240/ 415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 93 | Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick in size. |
| 94 | .Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 3 mtr. Long GI earthing electrode, 80 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound |
| 95 | Supply, Installation, testing and commissioning of 20 KVA, 3-Phase, 415V,LT, Unbalanced AVR of Essentials, KE, ALBA, Chinar, Cosco make, operating from Input voltage of L-L-155-460V & L-N=90-265V, thereby producing the output voltage of 415V +_2% Phase to Phase and 230V +2% Phase to Neutral. The AVR should have inbuilt Over voltage protection, Under voltage protection & Over loading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oil having required di-electric strength. The stabilizer shall be capable of smooth operation up to 10% un-balanced in the load currents complete with servo bye pass system consisting of 100A four pole manual type change over switch. The supplier has to give guarantee for any manufacturing defect of the equipment for one year reckoned from successful commissioning. The job also Includes all applicable taxes, carriages, loading and unloading |
| 96 | Supply, laying, connecting and commissioning of 150 sq. mm 3.5 core PVC Insulated and PVC sheathed/XLPE power cable of 1.1 KV grade Aluminum LT cable, incl. cost of required al. thimbles duly crimped. (under ground) |
| 97 | Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs |
| 98 | SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 99 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) |
| 100 | Normal Incoming |
| 101 | 250 Amp, 36 KA, FP MCCB incl. Spreader links |
| 102 | Aluminum Bus Bar 500 Amp set of 4 strips |
| 103 | ON Load Change Over Switch FP 200 amp. (Front operated) |
| 104 | Aluminum Bus Bar 400 Amp set of 4 strips |
| 105 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set, 2 Nos, etc. |
| 106 | Outgoing |
| 107 | 63 Amp, 10 KA, TPN MCB |
| 108 | 63 Amp, 10 KA,DP MCB |
| 109 | Space for 16 way MCBs |
| 110 | Supply, installation , testing and commissioning of 3 star rating 1.5 Ton Inverter type split Air Conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrile foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit. The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Daikin/ Blue Star/ LG/ IFB). |
| 111 | Supply, installation , testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260Volt thereby producing output voltage of 230volts +_ 3%. (4 KVA) Please Enable Macros to View BoQ information |