Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | construction |
| 2 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the Engineer In Charges with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the Engineer In Charges.- Upto 2.40m Footing Depth.Data worked out for 48 m3 per day/8 hrs. |
| 3 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. A). Upto 2.40m Depth.Data worked out for 64 m3 per day/8 hrs. |
| 4 | Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the Engineer In Charges. -Mixing by manual means |
| 5 | Supplying and filling in foundation, basement, etc with filling M-sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the Engineer In Charges. |
| 6 | Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the Engineer In Charges. |
| 7 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the Engineer In Charges in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the Engineer In Charges. |
| 8 | Cement Concrete 1:5:10 (One cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers -Mixing by Manual means |
| 9 | Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9\" x 4 1/2\" x 3\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the Engineer In Charges. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Engineer In Charge in charge. |
| 10 | a) for foundation and basement |
| 11 | b) For superstructure in Ground floor |
| 12 | b) For superstructure in First floor (Terrace) |
| 13 | Brick partition walls of 11.00cm thickness using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three M-Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid forseparately) |
| 14 | Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four M-sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used , finishing and curing etc. complete complying with standard specification - Manual Mixing |
| 15 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 16 | Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the Engineer In Charges. (Payment for centering shall be given after the concrete is laid). |
| 17 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the Engineer In Charges. (Payment for centering shall be given after the concrete is laid). |
| 18 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the Engineer In Charges. (Payment for centering shall be given after the concrete is laid). |
| 19 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the Engineer In Charges. (Payment for centering shall be given after the concrete is laid) |
| 20 | Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m\") 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the Engineer In Charges. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 21 | For Foundation and Basement |
| 22 | For superstructure in Ground floor |
| 23 | Cement Concrete 1:3:6 (One Cement, Three M-sand and Six Hard broken stone jelly) using 20mm size hard broken stone jelly for dummy columns,etc., excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete and as directed by the Engineer In Charges. ( Dummy columns should be at least 1 metre height) -Mixing by manual means (For superstructure in First floor (Terrace)) |
| 24 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the Engineer In Charges.(Contractor has to make his own arrangements for the supply of Approved Brand steel reinforcement and binding wire) |
| 25 | For Foundation and Basement |
| 26 | For superstructure in Ground floor |
| 27 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the Engineer In Charges.- Mixing by manual means (Foundation and Basement) |
| 28 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standardspecification and as directed by the deparmental officers. |
| 29 | Ground Floor |
| 30 | Finishing the top of roof with one course of machine Pressed Tiles of 230mm x 230mm x 16 mm to 18mm of approved quality set in Cement Mortar 1:3 (One Cement and Three M-Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the Engineer In Charges |
| 31 | paving the floor with best quality vitrified Tiles of Double charged vitrified tiles of size 600 x 600 x 8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Engineer In Charge before use on works) |
| 32 | Paving the floor with best approved quality super fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum |
| 33 | Providing full nosing to the steps or platforms to the Granite slab of 20mm thick including neat finishing, polishing, cost of powder, tools etc as directed by the Engineer In Charges |
| 34 | Flooring with Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Engineer In Charge before use on works) |
| 35 | Dadooing walls with printed design colour glazed tiles of size 300 x 450 x 8mm conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the Engineer In Charges.(The make and brand of the tiles should be got approved by Engineer In Charge before use on works) |
| 36 | Supplying and laying of Interlocking Paver Block Stone 83mm thick Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the Engineer In Charges. |
| 37 | Providing polymer coating with specification The surface shall be cleaned to remove all dust, foreign matters, lose materials or any other deposits of contamination by rubbing with wire brush. Cracks and depression shall be filled up by fillers (cement sand mortar as per recommendation of suppliers). Prepared surface shall be thoroughly pre-wetted for one hour. Preparation of polymer modified cementitious slurry:- Dry blend and liquid blend shall be mix into the desired ratio as per recommendation of supplier. The mix shall be stirred thoroughly, until no bubbles remain in the mix. Any lump found in mix shall be removed First coat of polymer modified cementitious slurry shall be applied by brush on wet cleaned surface.Subsequently, fiber glass cloth shall be laid over first coat of polymer modified cementitious slurry.Second coat of polymer modified cementitious slurry shall be laid over fibre glass cloth.Polymer modified cementitious brush topping shall be applied over second coat of polymer modified coating.The rate inclusive of Cost of materials and Labour etc., Complete |
| 38 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes 110 mm dia (In building with Two floor only) having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 39 | Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc... complete complying with standard specification and as directed by the Engineer In Charges. |
| 40 | Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 6 Nos of SS 304 Grade Butt Hinges of size (125mm x 30mm) , 3 Nos. 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the Engineer In Charges - Double leaf.Type : Commercial ply on both sidesThickness: 35mm |
| 41 | Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS (Sliding door) etc., complete and as directed by the Engineer In Charges. |
| 42 | UPVC Window Specification :Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Engineer In Charge before use on work. |
| 43 | UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the In Charge Engineer before use onwork |
| 44 | Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the Engineer In Charges. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the Engineer In Charges. - Single leaf of size 1.00m x 2.10m. |
| 45 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 46 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing.The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 47 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the Engineer In Charges. |
| 48 | Supplying and fixing Mild Steel Rolling Shutter etc.,complete complying with standard specifications and as directed by the Engineer In Charges. |
| 49 | Providing Cornice Work for Gyp Board False Ceiling etc., complete in all floors complying with standard specification and as directed by the Engineer In Charges.(Ground floor) |
| 50 | Supplying, fabricating, erecting and fixing Hilux board plain sheets (10mm thick) (or) equivalent board false ceiling upto a ceiling height of 4.5m from floor level. |
| 51 | Supplying and fixing fine polished cuddapah slab of 38 / 40mm thick thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed by the Engineer In Charges |
| 52 | Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Engineer In Charges. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Engineer In Charge befoe use on work. |
| 53 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the Engineer In Charges. |
| 54 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the Engineer In Charges |
| 55 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (water proof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers.( The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc.,complete. The putty should be got approved by the Engineer In Charge before use on work |
| 56 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the Engineer In Charges. |
| 57 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the Engineer In Charges. |
| 58 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the Engineer In Charges. (The make, quality and colour of paint should be got approved by the Engineer In Charge before use on works.) |
| 59 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the Engineer In Charges. (The make, quality and colour of paint should be got approved by the Engineer In Charge before use on works.) |
| 60 | Supplying, laying and jointing CPVC pipes OF Standard Dimension Ratio -13.50 (Pressure class 2) conforming to IS:15778 - 2007 of approved quality and best variety of the following dia including cutting and fixing CPVC specials using CPVC adhesives (Solvent Cement) (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications and as directed by the departmental officers. (The CPVC pipes shall be got approved by In Charge Engineer before use on works) - Internal water supply above ground level. 25mm dia CPVC pipe |
| 61 | Supplying CPVC Specials of SDR 11 Conforming to IS 17546-2021 in water supply arrangements (both in internal and external water supply arrangements |
| 62 | a) 25mm dia CPVC Elbow |
| 63 | b) 25mm dia CPVC TEE |
| 64 | c) 25mm dia CPVC Union |
| 65 | d) 25mm dia CPVC Nipple |
| 66 | Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Engineer In Charge before use on works - Internal water supply above ground level. |
| 67 | a)25mm dia UPVC Pipe |
| 68 | a)32mm dia UPVC Pipe |
| 69 | Supplying UPVC Specials in water supply arrangements (both in internal and external watersupply arrangements |
| 70 | 25mm Dia Union |
| 71 | 32mm Dia Union |
| 72 | 25mm dia Elbow. |
| 73 | 32mm dia Elbow. |
| 74 | 25mm dia Tee. |
| 75 | 32mm dia Tee |
| 76 | 32X25 Reducer |
| 77 | 25x20 Reducer |
| 78 | 20x15 Reducer |
| 79 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Engineer In Charge before use on work. |
| 80 | 25mm dia gate valve |
| 81 | 32mm dia gate valve |
| 82 | Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Engineer In Charge before use on works.) |
| 83 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the Engineer In Charges. (The water closet should be got approved by the Engineer In Charge before use on works). |
| 84 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC fixed on to the wall, complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.....such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the In Charge Enginer before use on works) White glazed European water Closet with 10 lit capacity PVC Flushing tank with CI Brackets |
| 85 | Supplying and fixing of Granite Sink of size 600 x 600 x 250mm including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the In Charge Engineer before use on works] |
| 86 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Engineer In Charge before use on woks) |
| 87 | Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by In Charge Engineer before use onworks). |
| 88 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., completecomplying with standard specifications. |
| 89 | Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the Engineer In Charges (The CP shower rose should be got approved by the Engineer In Charge before use on works). |
| 90 | Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Engineer In Charge before use on the works) |
| 91 | Supplying, laying and jointing glazed stoneware pipes of following dia of approved best quality with spigot and socket ends (in reverse direction) in dry condition and laid in loose joints (i.e.) without cement and spun yarn, so that the waste water can be drained to the trenches already available, excluding cost of earth work excavation, cost of re-filling with crushed stone sand/ earth, but including laying the pipe in true alignment and gradient and conducting required water supply test for draining with necessary tools and plants, etc., complete complying with standard specifications. |
| 92 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Engineer In Charge before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid belowground level |
| 93 | 75mm dia |
| 94 | 110mm dia |
| 95 | 160 mm dia |
| 96 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications |
| 97 | 75mm dia PVC Elbow |
| 98 | 75mm dia PVC Tee |
| 99 | 75mm dia PVC Elbow with Door |
| 100 | 75mm dia PVC Bend |
| 101 | 110mm dia PVC Elbow |
| 102 | 110mm dia PVC Tee |
| 103 | 110mm dia PVC Y |
| 104 | 110mm dia PVC Bend |
| 105 | Supplying and fixing position PVC Nahani Trap / Floor Trap of the following sizes with best PVC gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of cM-sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Engineer In Charge before use on works) |
| 106 | Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the Engineer In Charges |
| 107 | Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications |
| 108 | Supplying and filling 20mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc. complete complying with standard specification. |
| 109 | Supplying and filling 40mm guauge HBGS stone jelly for dispersion trench including loadingconveying and unloading and as directed by the departmental officers etc. complete complying with standard specification. |
| 110 | Drilling of 6\" or 150mm dia borewells in hard rock areas anyware in Tamil Nadu including transportation to the work site in hard rock areas and developing the borewells. |
| 111 | Upto 150m below ground level |
| 112 | From 151m Upto 180m |
| 113 | From 181m Upto 210m |
| 114 | Supplying and delivery of PVC Casing pipe as per IS 12818/1992 with ISI Marking of following diameter in 3m length with screwed and socket end and centering guides for every 15m length of pipe to suit deep bore wells for delivery including loading, unloading, freight, insurance etc.,complete (Rate inclusive of Excise duty) |
| 115 | Supplying and fixing of suitable PVC end cap (6Kg/cm2) for 6\" dia bore well of best quality with ISI mark. (The PVC end cap should be got approved by the departmental officers before execution) |
| 116 | Supplying and erecting of Three phase 5.00 HP wet submersible pumpset suitable for 150mm dia borewell as per IS 8034/2002 without panel board of best approved quality with ISI mark including all accessories.The rate including fixing and jointing submersible cable with wire into the starter to the required depth and also fixing of riser pipes to the required depth values erection charges pressure gauge upto the exterior walls pump room and laying and jointing the cable and twin earthing as per IE rules etc., and testing the pumpset and trail run for 10 days etc., complete complying with standard specification and as directed by the Engineer In Charges. |
| 117 | Supplying and erection of 40mm dia submersible UPVC pipe standard size of ISI make 3 metre length including transportation charges, erection inside the borewell with required joints specially, etc., complete complying with standard specification and as directed by the Engineer In Charges. |
| 118 | Supplying and erection of submersible wire 3 core 4 sq.mm cable PVC insulated SC unsheathed copper conductor of 1100v grade wire ISI make including erection in side the borewell and open run of clamping etc., complete complying with standard specification and as directed by the Engineer In Charges. |
| 119 | Supplying and fixing of Nylon Rope for Bore-well, as directed by Department Officers. |
| 120 | Supplying and fixing of 3 phase panel board DOL starter with two level guard and auto start for motor with single phase preventor and necessary accessories, etc. complete complying with standard specification and as directed by the Engineer In Charges. |
| 121 | Pre construction Antitermite treatment for the Construction of building all chemicals as per standard specification including labour charges for preparing the area for treatment spraying chemicals and other incidental charges etc., complete. The rate quoted shall be giving antitermite treatment to the building for the following four stages including breaking the termitemounds making holes with crowbars and pouring chemicals etc., complete as per IS 6313 - 1981 and as directed by the Engineer In Charges etc., complete including cost of chemicals labour transport storing etc., The termite chemicals should have 0.5% concentration for entire operation Stage 1: Sprayingantitermite treatment chemical solutions for the foundation before laying the foundation concrete bottom and sides of the foundationStage 2: Spraying antitermite chemicals to the grade beam level spraying has to be done for the grade beam, brick masonry in the superstructure in contract with backfill earth. Stage 3: Spraying antitermite treatment chemical on crushed stone sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the crushed stone sand filling in basement and after leveling the consideration operation is over. Stage 4: Spraying antitermite chemicals solution alround the building (outside of the building) by making crowbar holes around the building before laying the plinth protection, this holes to be closed after the treatment. |
| 122 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS 15683 with pressure gauge, discharge hose & control nozzie, wall mounting bracket, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the DepartmentalOfficers. |
| 123 | Supply and fixing Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS:15683., complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT /SAFETY FIRST ? EQUIVALENT. |
| 124 | Supply and ketp in position of Trolley Mounted Water CO2 Stored Pressure Type 50 litres capacity Fire Extinguisher as per IS: 13385, complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, mounting trolley with moving wheel, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Engineer In Charges. Make: EXCELENT/SAFETY FIRST /EQUIVALENT. |
| 125 | Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharges hose, wall mounting bracket, safety clip, etc., as directed by Engineer In Charges. |
| 126 | Supply and kept in position of 9 litres campacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Engineer In Charges. |
| 127 | Supply, installation of Fire fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20 mm dia ball valve and open and close spray nozzie, warm clip, etc., as per the standard pattern of nay reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, necessary scaffolding and re-doiing the dismantled portions to its original condition wherever found necessary., etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 128 | supply and fixing of 1400mm (56\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 1 metre down rod on the existing fan clamp |
| 129 | Supplyandfixingof4FeetLED20WFittingwithLED20Wtube(HigherEnd)completewithconduitpipesuspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube |
| 130 | Wiringwith3x1.5sq.mm.PVCinsulatedSCunsheathedFRLScopperconductorof1100VgradeinsuitablePVCrigidpipeonwallandceilingwithPVCaccessorieswithTWswitchboxwith5AFTswitch(twoway)influshwithwallandcoveredwithhylemsheetof3mmthickwithpaintingofsuitablecolourwithcontinuousearthwireconnectionof1.5sq.mm copper wire for open PVC staircase light point |
| 131 | Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one No 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one No 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 18 Nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with Earth connection only. |
| 132 | Wiringwith2x4sq.mm.PVCinsulatedSCunsheathedFRLScopperconductorcableof1100VgradeinsuitablePVCrigidpipeconcealedinwallandceilingwithPVCaccessoriesinflushwithwallwith150mmx100mmx113mmTWswitchboxwith3mmthickhylemsheetfor15A3pinnoninterlockingwallsocketwith15Aflushtypeswitchwithcontinuousearthwireconnectionof4sq.mmcopperwireandmakinggoodoftheconcealedportionwithsuitablecolourfor concealed power plug point |
| 133 | Supply and Laying of 3.5 C X25 sqmm PVC Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of .75 metre and refilling the earth to make good |
| 134 | Supply of and fixing of 200ATPN Switch Connector fuse units in sheet steel enclosure with HRC fuses double breaker |
| 135 | Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 136 | Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End |
| 137 | Supply and fixing of 2 no. 6A two module socket, 1no.6/16 A two module socket , 2 nos. 6A one module switch, 2 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End |
| 138 | Supply of 200A Three phase 500V 4 Pole change over switch on suitable angle iron frame work with Ms cable entry boxes earth connection PWD Earthing |
| 139 | Entrance Name board 7.31M X 1.22M with LED Lighting Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail