| 1 | Demolition of PCC in ground floors and paving not exc 15cm thickness (below or above groundlevel) |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and as directed. |
| 3 | Dismantling Plain or corrugated steel sheeting, any gauge,thickness, including Nainital or similar pattern roof coverings |
| 4 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steelsheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof coveringin roof covering /cladding to wall,fixed withself tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified. |
| 5 | S&F prepainted galvalume aluminium zinc coating GI based plainsteelsheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof coveringin roof covering /cladding to wall,fixed withself tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified. |
| 6 | M&L Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. |
| 7 | M&L for MS work as in Wind Tie in roof and MS structural works in trusses, etc with screwed ends including nuts, washers and mild steel plates for walls chimneys, roofs arches etc any kind rods and straining bolts conforming to Fe 410-0 or Fe 310-0 complete all as specified . |
| 8 | Material and labour for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxideprimer complete all as specified and as directed |
| 9 | Material and labour for preparation of old steel surfaces of any description, not otherwise described,over 10cm width or girth andapplying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed. |
| 10 | M&L 40mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in floors, laid in panels and finished even & smooth withoutusing extra cement complete all as specified and directed. |
| 11 | Material and Labour for 75mm thick Plain Cement Concrete 1:3:6 type C2 using40 mm graded stoneaggregate as in plinth protection, floors, pavings and hardstanding etc, finished even smooth without using extra cement etc including necessary forwork, complete all as specified and as directed. |
| 12 | Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water, removing rubbish/debris etc complete all as specified and as directed. |
| 13 | Material and labour for rendering 15 mm on fair faces of brick or concrete surfaces in CM 1:6, finished even and fair without using extra cement complete all as specified and directed. |
| 14 | Material and labour for 15 mm thick renderingon brick/concrete surfaces in two layers in CM 1:4, finishing coat of 5mm thick, finished even and smooth without using extra cement complete all as specified and as directed. |
| 15 | Material and labour for preparation of of new plastered/concrete surfaces of wall and applying two coats ofacrylic distemperof approved shade/tint over a coat of primer,over surface of wallall as specified and as directed. |
| 16 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 17 | M&L for complete removal by Washing, rubbing down and stopping and preperation of distempered and painted surfaces of walls, pillars,cornices by brooming down etc and applying twocoats of distemperoil emulsion over a coat of primer, complete all as specified & directed. |
| 18 | M&L for complete removal by Washing, rubbing down and stopping and preperation of old weather coat surfaces on brick/concreteof walls etc and applying two coat of antifungal weather proof emulsion paint over a coat of primer, complete all as specified and directed. |
| 19 | Supply and fix in repairs Steel rolling shutters 1.25mm thick, width of lath 75 mm, with out ball bearingwith gear operated type with chain wheel and hand chaintype as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position complete all as specified and as directed. |
| 20 | Supply and fixing Safety lever locks mild steel with 4 levers for rolling shutters complete all specified and as directed. |
| 21 | Supply and fixing Ball bearing for rolling shutters complete all specified and as directed. |
| 22 | Materialand Labour for Sand filling under floors or in foundations andincluding watering and consolidation complete all as specified and as directed. |
| 23 | Materialand Labour forplain cement concrete 1:2:4 type B1 using 20mm graded granite stone aggrgate as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, bed blocks of holdfast and the like including weathering, slightly rounded or chamfered angles and throatingincluding use of necessary form work all as specified and as directed. |
| 24 | Supply and fix Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeconforming to Fe 290 (Gde-E-165) complete all as specified and directed. |
| 25 | Supply and fix PVC wall panelling of surface laminatedany pattern and any shape of 7 to 10mm thicknessand any colourat any position inclusive of solvent cement and fixing at over a grid of PVC frame installed on the wall, which works as a base to install the PVC wall panels. Each panel have to interlock with each other complet all as per manufactures instructioncomplete all as specified and asdirected by Engineer in Charge. |
| 26 | Supply and fix PVC Supply and fix for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame, complet all as per manufactures instructioncomplete all as specified and asdirected by Engineer in Charge. |
| 27 | Taking down carefully copper/aluminium pointwiring(light,fan, socket or power) complete, (fittings suchasswitches,ceilingroses,pendants, regulators sockets etc. to be measured separately), and making gooddisturbed surfaces of walls, floors, etc. |
| 28 | M&L point wiring complete with 1.5 Sqm sincle core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including PVC conduits of suitable size fixed to wall/roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel duly painted concealed in walls, with modular cover plate, frame, all fitting and fixing accessories for housing switches, socket outlets, fan regulators etc, all as specified and as directed for the following :- |
| 29 | One light point/exhaust fan/fan point controlled by one switch |
| 30 | One socket point controlled by one switch on same board |
| 31 | One socket point controlled by one switch on independent board |
| 32 | One bell buzzer pointcontrolled by one switch on same/independent board |
| 33 | M&L for point wiring with two single core PVC insulated, unsheathed, FRLS multistranded unsheathed copper conductor cable of size 2.5 sqmm and one single core PVC insulated unsheathed FRLS stranded copper conductor of size 2.5 sqmm green in colour as earth lead through and including PVC conduits of suitable size with all fittings & accessories ISI marked including provn ofMS sunken boxes of appropriate size & thickness fixed flush to wall for 15/16 A switch-socket point on independent board complete. |
| 34 | M & L for point wiring using 4 Sqmm lSI marked 1.1 KV grade single core FR LS flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130-1984 and insulation conforming to IS:5831-1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 20 mm NB PVC medium grade conduits (concealed), conforming to IS: 9537 (Part 3)- 1983, colour coded as specified in IS: 11353-1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772- 2000 and suitable for modular cover-plates complete all as specified in IS: 732-1989 and directedfor 6 pin switch socket outlet 15 Amp on independent board complete all as specified and directed by Engineer in charge:-. Note: Circuit wire from DB to switch boards shall be included in the quoted rate. No additional payment will be paid to the contractor for the circuit submain. |
| 35 | Supply & fix Modular switch one way 10A,240volts 50Hz, 1 Module complete all as specified and as directed. |
| 36 | Supply & fixModular bell push 10A, 240volts 50Hz, 1 Module complete all as specified and as directed. |
| 37 | Supply & fix Modular socket outlet, 10 Amps, 3 pin, 240volts 50Hz, 2 Module complete all as specified and as directed. |
| 38 | Supply & fix Modular switch socket outlet, 10 Amps, 2 and 3 pin combined, 240volts 50Hz, 3 Module complete all as specified and as directed. |
| 39 | Supply & fix Modular switch socket outlet, 10/16 Amps, 2 and 3 pin combined, 240volts 50Hz, 3 Module complete all as specified and as directed. |
| 40 | Supply and fix Modular switch socket outlet, 6/16 Amps, 2 and 3 pin combined, 240volts 50Hz with and including one MCB single pole 16/20 Amps complete all as specified and directed. |
| 41 | Supply & fix Modular rotary type stepped regulator, 120/280 w, 240volts 50Hz, 1/2 Module complete all as specified and as directed. |
| 42 | Supply and fixingDecorative wall light, stainless steel Rust free fixture with white qlass diffuser suitablefor 1N x 7.5 Watt fllament lamp E2/ based Indoor wall lights, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified and as directed.Make-Havells model- FLORETINE WL 2LS ABR B22 GLASS Cat. No- LHFOAJE2TZ107X5 or equinalent in philips/Bajaj/crompton. |
| 43 | Supply and fixingLED Filament lamp 7.5/8W ST 64 base cap E27 type, warm white/cool white 2200K complete.,all as specified and as directed.Make-Wipro / philips/Bajaj/crompton. |
| 44 | Supply and fixing LED Warm white 12W picture light, indoor type, stainless steel Rust free fixture complete.,all as specified and as directed.Make-Philips 31403 or equinalent in Havells/Bajaj/crompton. |
| 45 | Supply & fix MCB SP 6-32 amp rating 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.Make: Indo Asian/ L&T/Crompton Greaves/Havells |
| 46 | Supply & fix MCB SPN 40-63 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed.Make: Indo Asian/ L&T/Crompton Greaves/Havells |
| 47 | Supply & fixing in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed. |
| 48 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FRLS) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC conduit, complete all as specified and directed. Note-3 run of 4 sqmm PVC copper wire and One run of PVC conduit shall be measured and paid as oneunit. |
| 49 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FRLS) 10 sqmm copper conductor multi stranded and one run of 10 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC conduit, complete all as specified and directed. Note-3 run of 10 sqmm PVC copper wire and One run of PVC conduit shall be measured and paid as oneunit. |
| 50 | Cutting chases, pinning in. making good to facings where required and ointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and as directed. |
| 51 | Schedule of Credit (Minus) Rs.106910.00NOTE: Bidder shall insert credit amount of Rs. 106910.00 as ratein Green field under Col-13. |