| 1 | Surface excavation n.exc 30 cm deep & avg 15 cm deep & getting out in any type of soil complete all as specified and as directed. |
| 2 | Excavation in trenchesn.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm as in any type of soilcomplete all as specified and as directed. |
| 4 | M&L PCC 1:4:8 type D2 using (40 mm graded aggregate) in foundation filling and mass concrete complete all as specified and as directed. |
| 5 | M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffits (if any) of foundations and plinth beams and similar work etc; rough finish surfaces complete all as specified and as directed. |
| 6 | M&L for providing Reinforced cement concrete (nominal mix) type B1 (1:2:4) 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 7 | M&L for Reinforcement 10mm dia and over TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 8 | M&L for Reinforcement 8 to 10mm dia TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia in stirrupscomplete all as specified and as directed. |
| 9 | M&L for precast cement concrete block masonry with solid blocks of PCC (1:3:6) type C-1 (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed) exc 10cm in width and set and jointedin Cement Mortar (1:6) complete all as specified and directed. |
| 10 | S&F roof trusess (framed), vertical pole , trussed ,purline, crane gantries rails and fastenings and heavy bracket framing (beam tea angle chanell or flat section ) including distance pieces,cleats etc confirming to Fe 410-W (grade -E-250) quality a complete all as specified and directed. |
| 11 | S&F Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe 290 Gde-E-165 quality a complete all as specified and directed. |
| 12 | S&F Plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment etc confirming to Fe 410-W (grade -E-250) quality a complete all as specified and directed. |
| 13 | S&F Pre- painted galvalume aluminium zinc coating thermal insulated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws omplete all as specified and directed. |
| 14 | S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 15 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 16 | Returning,filling in,including spreading,levelling,watering and well ramming in layers not exc 25 cm each layer in hard/dense soil complete all as specified and directed. |
| 17 | Removing excavated soil n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 18 | M&L for 15 mm thick rendering on fair faces of brick work or concrete wall surfaces in CM 1:4finished fair and even complete all as specified and directed. |
| 19 | M&L for rendering 15 mm thick in CM 1:6 finished even without using extra cement over fair faces of brick work or concrete wall surfaces complete all as specified and as directed. |
| 20 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement including provision of construction joints complete all as specified and as directed. |
| 21 | S & F powder coated anodised Aluminium alloy sections sliding windows with frames 92 X29.6 X1.10mm , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.45mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed.Note : Making all edges i.e. cill and jamb good by cement mortar 1:3 complete all as specified and as directed. |
| 22 | M & L powder coatedaluminium deco grill medium grade of mesh size 75mmx75mm with 6mm square anodised aluminium bars fixed with aluminium frame of size 9x9x1 mm complete all as specified and as directed. |
| 23 | S & F for anodised Aluminium partition/ door frame of size 100 x44 x 1.98mm thick with one or more rebates and shutters pull and push type or side hung type (with or without aluminium sash bars) comprising of top & lock rails of section 115 x 44 x 1.98mm thick, bottom rail of section 150 x 44 x 1.98mm thick and stiles of section 85 x 44 x1.98mm thick including necessary jointing cleat, glazing clip, rubber packing anodized aluminium beading, screws, anodized aluminium fittings such as floor spring or hinges 100mm size with hydrolic door closer, handles \"D\" type 125mm, floor door stopper, tower bolts 200mm, sliding door bolt 300mm or mortice lock with 5mm thick tinted glass /pre laminted particle board (Novapan) panel and making good to the disturbed wall surfaces to match existing surface complete all as specified and directed. |
| 24 | Material & Labour for preparation of old/new wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 25 | M&L for preparation ofplastered surfaces of wall and applying 2 coats ofOil Bound distemperover 1.5mm to 2mm thick wall putty finished to a even and smooth finish over a coat of alkali primer complete all as specifed and directed. |
| 26 | M/L for two coat of synthetic enamel paint( Ist quality) over and including a coat of red oxide primer on newsteel surface including preparation of surface over 10Cm width or girth complete all as specified and directed. |
| 27 | M&Lfor hardcore of broken stone of gauge n. exc 63mm, deposited spread and levelled in layers n exc 15 cm thick watered, rammed and rolled to true surface with8 to 10 tonne power roller/vibratory roller complete all as specified and directed. |
| 28 | M&L 100 mm thick PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in flooring Finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 29 | M&L for Point wiring complete with FR PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,1.5 Sqmm (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC surfaceconduit medium grade ,minimum 20 mm dia, ISI Marked,with sutaible size of 1 to 8 module metal flush boxes and back plate for mounting of modular switches/socket and regulators and including modular fornt plate with all acessories complete . |
| 30 | (a)One light point controlled by one way one switch SP 5 Amps ,240 V. |
| 31 | (b)One switch socket outlet 3 Pin, 5 Amps, SP on independent board. |
| 32 | (c)One switch socket outlet 3 Pin, 5 Amps, SP on sameboard. |
| 33 | All as per the above item No 29 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet complete all as specified and as directed. |
| 34 | S&F modular switch one way 6 Amps , 1 module type complete all as specified and directed. |
| 35 | S& f modular socket , 6 Amps , 2/3 pin combined 2 module complete all as specified and as directed. |
| 36 | S& f modularswitch socket combination, 6 Amps / 16 Amps , 2/3 pin combined 2 module complete all as specified and as directed. |
| 37 | S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete all as specified and directed. |
| 38 | Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting uptoPVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirementand 2 Nos ofround or square PVC bolck for fixing of FTL fitting complete all as per directed. |
| 39 | M&L for sub main wiring with two runs of 1.5 Sqmm (2x1.5 sqmm )1100 volts grade single core FR PVC insulated unsheathed multistranded copper conductorcableconfirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 1.5 Sqmm (1x1.5 sqmm )single core FR PVC insulated unsheathed copper conductor cableas earth wire complete all as specified and directed.Note:- 2 runs of 1.5 Sqmm ,one run of 1.5 Sqmm( 2x1.5 sqmm + 1x1.5 sqmm ) cable and one meter of conduit will be measured as one unit again complete all as specified and as directed. |
| 40 | M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nutsall shown in electrical plate No.3 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnelwith watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.(iii)Earthing shall be tested as specified incasul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (iv) On teting after complataion of earthing,if the desired earth resistance is not obatined the earthing wiil be re done by thecontractor at his on risk and cost to the entire satisfaction of the Engr - in - charge |
| 41 | S&F sheet metal enclosures fordistribution board when MCB to be used TPN ( Triplepole and neutral ) 4 way, 415Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door typecomplete all as specified and directed. |
| 42 | S&F MCB TPN, 63 Amps,415 Volts, rupturing capacity 10 KA.\"B\" Series complete all as specified and as directed. |
| 43 | S&F MCB TP, 25 to 63 Amps,415 Volts, rupturing capacity 10 KA.\"B\" Series complete all as specified and as directed. |
| 44 | S&F MCB SP, 5 to 32Amps, 240 Volts, rupturing capacity 10 KA \"C\" Series complete all as specified and as directed. |
| 45 | S&f 24 inch ss-304 air turbo ventilator including all connection & accessories all as specified and directed. Note: the rate inclusive of connection to the tin shed with all connection item.(a) moc of vanes aluminium(b)moc of top plate ss 202(c)moc of bottom ring pp ring(d)height of ventilator 375±5 mm(e)center dia. Of ventilator 660±5 mm(f)dia. Of top plate 380±5 mm(g)dia. Of bottom ring 610±15 mm(h)nos of vanes 26 nos rolled formed(i)thickness of vanes 0.5 mm(j)nos of bearing 02 nos(k)bearing type standarad 6201/6202 zz(i)rivets aluminium |
| 46 | S&F 150W Panel light min 4*1 ft Indoor sports ground light with following specification:(a)Led beam angle -120 degree.(b)CRI: >80.(c) Colour :cool white/white.(d) Luminious effieciency :140 Lm/W.(e) THD:<10%.(f)Driver Surge Protection :4-6KV. (g)External Surge Protection :10KV(h) Housing Color Type:Anti-dust Off grey powder coating (i) Glass Type :Anti-glare diffuser glass (min 2 mm thickness).(j)IP Rating:IP54 – Dust proof (Protection against Dust & Water Splashes).(k)Mounting Style :Wall mounting/ceiling/Hanging.(l) Housing Material :Metal body (14 gauge (1.9mm) Thickness). |
| 47 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. |