| 1 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches,pillars,etc,but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 2 | Material and Labour for precast cement concrete block masonry with solid blocks exceeding 10cm in width, of grade C4 all as per IS 2185 , having minimum average compressive strength 4 N/sqmm at 28 days and density not less than 1800 kg/cum, set in CM 1:6 all as specified and directed. |
| 3 | Material & Labour for renderimg in CM 1:4, 15 mm thick on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed. |
| 4 | M& L for rendering 10 mm thick cement plaster in CM 1:3 on fair faces of brick work on concrete surfaces on ceilingincluding finished even and smooth all as specified and directed.(without using extra cement). |
| 5 | Dismantling of floor hearth or wall tiling, terrazo tiles of anmy thickness including cement mortar bedding (but not backing) removingtilesand rubbish off the premises. |
| 6 | M&L Screedbed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:4. |
| 7 | M&L PCC 25 mm thick (1:2:4) Type-B-1 (using 20mm graded crushed stone aggregate) as in level course to receive to floor tilescomplete all as specified and directed. |
| 8 | M & L for Virified Ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. |
| 9 | M & L for Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 10 | M & L for glazed ceramic coloured tiles with border tile pattern in vertical surfaces350 x 250x 7 mm / 450 x350 x7 mm / 300 x 450 x 7 mmthick , set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and above 10 mm thick cement plaster in 1:3 as backing coat complete all as specified and as directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for in roof. |
| 12 | S&F Steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to I.S.1611-1998 grade st-240 including painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor\"s workshop before fabrication. |
| 13 | M&L painting to steel and iron surface applying 2 coats of sythetic enmal paint over one coat of primer including peparation of surface all as specified & as directed. |
| 14 | Dismantling of wall ceiling boards ( fibre, plup, insulation, etc) nor insulation boards/slabs/blamkets, any thickness, including cover fillets. |
| 15 | S & F 605 mmx605 mm Powder coatedsnap grid frame work for false ceilingHangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long andexpansion hold fasteners 12.5mm dia. 40mm long, (frame work shall made as per site requirement for any type , shape ) complete all as specified ®all as specified and dircted. |
| 16 | S & F 600 mm x 600 mm x 10mm thick pre paintedPerforated Gypsum board ceiling withback finished with pvc sheetfor fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed. |
| 17 | M&L for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheetPVC sheet inclusive of solvent cement and fixing at site on PVC frame as specified and directed. |
| 18 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as specified and directed. |
| 19 | S&F in repairs18 mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame work all as specified and as directed. |
| 20 | Taking down and removing to or from store chowkats or framesexc 1.5 sq. but nexe 4 sqmm each but with shutters (without taking off shutters from the frames) |
| 21 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixinghardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated),steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose. Glass shall be measured & paid seperately as supply only)(B) Area exceeding 2.00 sqm each |
| 22 | Supply only Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed |
| 23 | Supply only 4 mm sheet glass, ordinary qualityand glazing with oil putty in squares exc 0.5 sq m Each pane all as specified and as directed |
| 24 | Dismantling timber scantlings 40 sq. cm and over in section, in any position |
| 25 | M&L 2nd class hard wood exe 13 sq cm n exe 25 sq cmPlain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads. |
| 26 | Taking up or down GI tubing 20 mm bore from trenches/wall including all fittings segregated and stacking the pipe complete all as specified and directed. |
| 27 | S&F in repairs20 mm (OD)CPVC PipeSDR 11 & Plain CPVC SDR 11 Fittings such as Tee, Elbow, nipple and small piece of pipe in trenchesor fixed to wall/Ceilingcomplete all as specified and as directed by Engineer-in-Charge |
| 28 | S&F in repairs including disconnecting tanks ,1000 Ltrs Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) triple layered, hoisted and fixed in position all as specified in SSR Part I |
| 29 | S&F in repairs including disconnecting tanks ,S&F 500 Ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) Triple layered, hoisted and fixed in position all as specified in SSR Part I |
| 30 | S & F in repairs Ball valves high 25mm borepressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) |
| 31 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons incl granite slab in kitchen platform Laid, bedded and pointed in any mortar etc all as specified and as directed. |
| 32 | M & L for18 to 20 mm thick 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado or cooking platform etclaid over cement screed bed 15 mm thick in CM 1 : 4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 33 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations. |
| 34 | S & F Powder coated Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 35 | S&F in repair Vitreous china wash hand basin(Table Top), white, flat back of size 630 x 450 mm white excluding taps, waste, chain and plug and porcelain stopper but including bracket, cutting for and pinning the ends of brackets including PTMT waste coupling 32 mm dia as suitable complete all as specified and directed by the Engr-in-Charge. |
| 36 | S & F in repairs 15 mm borePillar taps, cast copper alloy, with capstan heads,swan neck typechromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and as directed. |
| 37 | S & F in repairs 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 38 | S&F in repairs PVC bends of 110 mm dia complete all as specified and directed. |
| 39 | S&F in repairs PVC (SWR) floor trap, plainwith grating including jointing with solvent cementbends of 75 mm dia complete all as specified and directed. |
| 40 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 41 | S&F in repair of CP Health faucet (hand shower) complete set with 1.5 mtr long pipe abd fittings complete all as specified and as directed. Make Cera and equivalent |
| 42 | S&F in repairs for PVC low level flushing cistern, white, 10 Ltrs capacity complete with all internal accessories & fixed to wall & making good to wall surfaces incl. taking down existing flushing cistern complete. |
| 43 | S&F in repairs Vitreous China Indian type water colset (Squat pattern) white complete as fixed in repair excluding flushing cistern and flush pipe \"Orissa\" pattern size 580x400 with integral footrest inject connection to trap antisyphonage etc complete incl joint between flushing pipe and socket of WC. |
| 44 | S&F in repairs 32 mm dia flexible waste pipe for wash basin and kitchen sink complete all as specified and directed. |
| 45 | S&F in repair PTMT waste coupling of 32 mm dia (half or full thread) including taking down old coupling of any description complete all as specified and directed. |
| 46 | S&F in repair PVC connection pipe 15mm dia and 600 mm long with two PTMT nuts at each ends with rubber washer. |
| 47 | S&F in repair Chromium plated fancy type bib taps with wall flange, cast copper alloy with round operating knob screwed down high pressure, screwed for 15mm bore iron pipe complete all as specified and directed. |
| 48 | S&F in repair stop valves/angle cocks or two way angle cockcast copper alloy concealed type long body with round operating knob fency type chromium plated screwed down high pressure, screwed both ends for 15 mm bore iron pipe or brass ferrule. |
| 49 | M&L for complete removal of existing treatment of wallsand applying two coats of oil bound distemper on wall surfacesover a coat of alkali resistant primer over 1.50 mm thick wall care putty complete all as specified and directed. |
| 50 | M&L for preperation of newly plastered surfaces of wallsand applying two coats of oil bound distemper on wall surfacesover a coat of alkali resistant primer over2mm thick wall care putty complete all as specified and directed. |
| 51 | Material and labour for prepration of old wood or wooden based surfaces or perviously treated surfaces,not otherwise described,over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed |
| 52 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 53 | M&L Cement concrete type B-1, 1:2:4 (20mm graded stone aggregates) 75 mm thick sub floors, finished even & rough |
| 54 | M&L Cement concrete type B-1, 1:2:4 (20mm gradedstone aggregates) 50 mm thick sub floors, finished even & rough |
| 55 | M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick jointed with grey pigment cements/pigments and pointed in neat cement slurry in floors 15mm thk cement screed base laid in mortar 1:4including pointing in white cement (1:2) all as specified and as directed. |
| 56 | M&L Hardcore of guage exc 63mmbut n exc. 100 mm, deposited,spread and levelled in layersn exc. 15cmthick, wateredand rolled/rammed to a true surface |
| 57 | M&L 100 mm thick Cement concrete type B- 2,1:2:4 (40mm gradedstone aggregate) as subbaseall as specified and as directed. |
| 58 | M & L for Cement concrete work in pavement/hard-standing of flexural strength 40kg/per square centimetre in field using400 kg of cement per cubic metre, thickness of concrete 25 cm or less |
| 59 | M&L for 2mm thick epoxy screed & 1mm thick epoxy topapplying jointless( min3-3.5mm) thick multi layer solvent free epoxy based flooring with broad cast finish of approved make shade as per specification/ direction of manufacturers incl. preparation of surface of concrete substrate by mechanical means to remove dust laitance, conaminants etc. grinding vaccum surface cleaning, groove cutting, groove filling and to form the vegnised anchor profile on the floor substrate etc. |
| 60 | M&L for line marking with florthan PU 100 mm wide & 1 mm thick as per site condition. |
| 61 | Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power)including fittings and fixtures such as switches , ceiling roses , pendentsregulators , sockets , light fittings etccomplete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC. |
| 62 | Taking down carefully copper / aluminium sub mainwiring including teak wood batten / conduit and making good the disturbed surface of walls as directed. |
| 63 | Taking down ceiling fan/ wall fan of any size, sealing cable end,dismantling blades and removing fan and blades to store and refixing the same as per existing site required and connecting up including provision of cable, extended fan rod from ceiling rose or connector to ceiling fan complete all as specified and directed by Engr-in-Charge. |
| 64 | Dismantling and Taking down fluorescent light fitting single /double tube any wattage/any size all as directed. |
| 65 | Taking down carefully main switches DB\"s/ MCB DB\"sand making good the disturbed surfaces of wallsetc complete all as specified and directed. |
| 66 | Relocation/ Shifting of Existing Distribution box from the office to adjacent wall outside the room with rain protection sintex box and reroutingof existing power supply with out any damage to distribution box (damages of panel/ meters to be rectified/replace of same specification of damaged items to be replace by the contractor with in the quoted cost) including demolishingthe existing PCCremoving the distributon box from its existing place,including diconnecting the cables withline diagram /identification marks to relocation points, shifting the Existing distribution box with required PCC footing 1:2:3 to the required place as per site requirementwithconnecting incomming cables and out going cables to suit the existing required glands as per site requirement (Note:- after completion of work, conformation and testing the supply of the each point from users. |
| 67 | M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the following:-(a)One light point /Fanpoint controlled by one switch. |
| 68 | (b)One 5 Amps socket point on independent board. |
| 69 | M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed. |
| 70 | Material and Labour for ceiling rose 3 terminals complete all as specified & directed. |
| 71 | Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed |
| 72 | S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed. |
| 73 | S & F modular socket 06/16 Amps 2/3 pin2 modulecomplete all as specified & directed. |
| 74 | S&F modular White cover plate with frame 3 module complete all as specified & directed |
| 75 | S&F modular metal flush box 3 module complete all as specified and directed. |
| 76 | Supply & fixing modular switch 16 Amps 1 modulecomplete all as specified & directed |
| 77 | S&F modular metal flush box 6 module complete all as specified and directed. |
| 78 | S&F modular White cover plate with frame 6 module complete all as specified & directed |
| 79 | Supply and fixing ceiling fans complete incl anti suicide rods with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep Min air delivery 210 CFM with service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) |
| 80 | Supply and fixing \"S\" Hooks for ceiling fans hanging of size 1200 mm sweep making hole on roof for fixing \"S\" hooks of 10mm dia MS and making good for damaged surfaces all as specified. |
| 81 | S & F MCB SPN 32Amps, \"C\" series, 240 V complete incl making conections all as specified and directed. |
| 82 | S & F MCB SP 6-32 Amps, \"C\" series, 240 V complete incl making conections all as specified and directed. |
| 83 | S & F MCB DB SPN 8 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. |
| 84 | Supply and fixing wall fan ofsingle phase 230/240V of size 400 mm sweep and grouting withnut , bolts & Fastenaron the wall and make good the disturbed surface and electric connection with 1.5 Sqmmthree core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed . |
| 85 | Supply and fixing in repairs 36W LED Fitting, 2 x 2recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED drivercomplete all as specified and directed. |
| 86 | M & L for sub main wiring complete with two runs of2.5 sqmmFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in recessed / surface of wall, roofs etc with one run of PVC insulated copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. NOTE :Two runs of cable, one run of conduit & one run of earth conductor shall be measured as one unit length. |
| 87 | M & L for sub main wiring complete with two runs of 4.0 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4.0 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. NOTE :Two runs of cable, one run of conduit & one run of earth conductor shall be measured as one unit length. |
| 88 | M & L for sub main wiring complete with three runs of 10 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 10 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. NOTE :Three runs of cable, one run of conduit & one run of earth conductor shall be measured as one unit length. |
| 89 | S & F MCCB DB VerticalTPN 12 Way\"A\" Frame,Including MCCB TPN 63 Amp Beaking capacity 16 KA -01 nos,Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. |
| 90 | S & F Supply and fixing 415V 10KA \"B\" curve miniaturecircuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning (i) TP 25 To 63 AMP incl making connections all as specified and directed. Make -Havellsor equivalent. |
| 91 | M/L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead wire 4.0mmdiaby means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSRPt I.The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm bents to centre complete including 15 mm GI tube for funnel and 20 mm for earth wire drawn through complete all as directed by Engr-in-Charge. |