| 1 | SCHEDULE \"A\" PART-I : BUILDING WORKSLump Sum Priced worked out by the Contractor for BUILDING WORKS as Listed in SCHEDULE \"A\" PART-I of Rs. 24,81,400.00 inserted by MES at SERIAL PAGE No._17_. |
| 2 | SCHEDULE \"A\" PART-II : EARTH WORKSLump Sum Priced worked out by the Contractor for EARTH WORKS as Listed in SCHEDULE \"A\" PART-II of Rs. 3,91,852.33 inserted by MES at SERIAL PAGE No._18_. |
| 3 | SCHEDULE \"A\" PART-III : INTERNAL WATER SUPPLYLump Sum Priced worked out by the Contractor for INTERNAL WATER SUPPLY as Listed in SCHEDULE \"A\" PART-III of Rs. 6,122.75 inserted by MES at SERIAL PAGE No._19_. |
| 4 | SCHEDULE \"A\" PART-IV : INTERNAL ELECTRIFICATIONSLump Sum Priced worked out by the Contractor for INTERNAL ELECTRIFICA-TIONS as Listed in SCHEDULE \"A\" PART-IV of Rs. 6,21,407.19 inserted by MES at SERIAL PAGE No._24_. |
| 5 | SCHEDULE \"A\" PART-V : AIR CONDITIONING & UPSLump Sum Priced worked out by the Contractor for AIR CONDITIONING & UPS as Listed in SCHEDULE \"A\" PART-V of Rs. 2,97,449.60 inserted by MES at SERIAL PAGE No._25_. |
| 6 | SCHEDULE \"A\" PART-VI : ROADS, PATHS & CULVERTSLump Sum Priced worked out by the Contractor for ROADS, PATHS & CULVERTS as Listed in SCHEDULE \"A\" PART-VI of Rs. 4,17,726.50 inserted by MES at SERIAL PAGE No._26_. |
| 7 | SCHEDULE \"A\" PART-VII : SEWAGE DISPOSALLump Sum Priced worked out by the Contractor for SEWAGE DISPOSAL as Listed in SCHEDULE \"A\" PART-VII of Rs. 69,350.05 inserted by MES at SERIAL PAGE No._27_. |
| 8 | SCHEDULE \"A\" PART-VIII : EXTERNAL WATER SUPPLYLump Sum Priced worked out by the Contractor for EXTERNAL WATER SUPPLY as Listed in SCHEDULE \"A\" PART-VIII of Rs. 1,23,415.28 inserted by MES at SERIAL PAGE No._28_. |
| 9 | SCHEDULE \"A\" PART-IX : EXTERNAL ELECTRIFICATIONSLump Sum Priced worked out by the Contractor for EXTERNAL ELECTRIFICA -TIONS as Listed in SCHEDULE \"A\" PART-IX of Rs. 11,69,405.90 inserted by MES at SERIAL PAGE No._29_. |
| 10 | SCHEDULE \"A\" PART-X : LIGHTING ARRESTOR & CHEMICAL EARTHINGLump Sum Priced worked out by the Contractor for LIGHTING ARRESTOR & CHEMICAL EARTHING as Listed in SCHEDULE \"A\" PART-X of Rs. 5,517.60 inserted by MES at SERIAL PAGE No._30_. |
| 11 | SCHEDULE \"A\" PART - XI : MISCELLANEOUS ITEMS |
| 12 | EARTH WORKSM&L Horizontal Boring of Holes under Road, Pavement, Hardstanding by Trenchless Technology Using Ultra Sounding Technique and necessary Machine/ T&P including HDPE Pipe of 150/160mm bore (dia) suitable for 0.4 mpa Working Pressure, complete all as specified and as directed.NOTE : Cost of HDPE Pipe and Hire Charges of necessary T&P will deem to be included in the Quoted Unit Rate. |
| 13 | INTERNAL ELECTRIFICATIONSS&F Flame Proof Ceiling Fan 1200mm Sweep, Single Phase, AC with suitable Length Mild Steel Down Rod duly making Holes, Fan Hook, Clamp with necessary Bolts, Nuts & Washers, etc. including Connecting up with Twin Core Twisted Flexible Copper Conductor Cable, complete all as specified and as directed. |
| 14 | S&F Flame Proof Ceiling Fan Regulator including Connecting up with Twin Core Twisted Flexible Copper Conductor Cable, complete all as specified and as directed. |
| 15 | S&F Flame Proof Exhaust Fan 450mm Sweep with Louvers, Single Phase with Fixing Arrangement using Fastener, Providing Electric Connection with and including Copper Conductor Cable of suitable Size and Length, 3 Core, complete all as specified and as directed.NOTE : Cost of Cutting/ Making Hole in Brick Walls built in Cement Mortar to suitable Size for Fixing of Exhaust Fan 450mm Sweep with Frame and Making Good in Cement Mortar 1:3 or Cement Concrete 1:2:4 (20mm graded stone aggregate) as required will deem to be included under respective Item of SCHEDULE \"A\" PART-I. |
| 16 | S&F Flame Proof Distribution Board 8-way, SPN, Single Phase including suitable Size Incomer MCB and Out-going MCB 25 Amp, Double Pole (DP), 10 kA as Incoming/ Out-going, fixed Flush with Wall inside the Niches or Outside on Wall Surface and Connecting up, complete all as specified and as directed. |
| 17 | S&F Flame Proof Distribution Board 4-way, TPN, Three Phase including suitable Size Incomer MCCB and Out-going, fixed Flush with Wall inside the Niches or Outside on Wall Surface and Connecting up, complete all as specified and as directed. |
| 18 | M&L Earthing Complete with Galvanised Steel Earth Platte Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connectedto GalvanisedEarth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded broken stone aggregates) and Pre-cast RCC Cover Slab of Size 450x450x50mm in Cement Concrete 1:2:4 (20mm graded broken stone aggregates), Reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, Mild Steel Round Bar 12mm dia Handle (01 No.), GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) \"Medium grade\" including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of Surplus Spoil upto a distance of 50 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed. |
| 19 | AIR CONDITIONING & UPSSupply & Installation Automatic Voltage Stabilizer 3.0 KVA capacity, Wall mounted, Copper wounded, Air Cooled, Single Phase, 230 Volt, 50 Hz, having Digital Display, Designed for Input Variation between 140 Volt to 280 Volt with Output Voltage stabilized at 220 Volt (+) 9.0%, Calibration Accuracy (+) 3.0%, Low-High Cut Off and Intelligent Time delay, complete all as specified and as directed. |
| 20 | Supply & Installation Automatic Voltage Stabilizer 5.0 KVA capacity, Wall mounted, Copper wounded, Air Cooled, Single Phase, 220 Volt, 50 Hz, having Digital Display, Designed for Input Variation between 140 Volt to 280 Volt with Output Voltage stabilized at 220 Volt (+) 9.0%, Calibration Accuracy (+) 3.0%, Low-High Cut Off and Intelligent Time delay, complete all as specified and as directed. |
| 21 | Supply, Installation, Testing & Commissioning 10 KVA On Line Stand Alone UPS 120 AH with 1 SMF Battery Bank suitable for Providing Power Supply to Computers/ Servers, Delivery at least 45 Minute Backup with Battery Banks, suitable for Incoming 415 Volts, 3 Phase +10% to -15%, 50 Hz Supply and 3 Phase Output Voltage including Provision for Rectifier/ Dual Converter, Bypass Switch, Inverter, Filter, Bypass and Static Transfer Switch for Automatic Switch Over, Providing Static Bypass Module High Switching Frequency Microprocessor based with built-in Technical Protections like Short Circuits, Over Load, High/ Low Voltage Cut-off Protection of Load from Micro Processor/ Software Controlled Annunciation, Protection (including against Input Phase Reversal) and Menu Run Diagnostic Module associated Cabling, Connections, Terminations, Erection including associated Foundation/ Masonry/ RCC Works for mounting on Base Channels, etc. complete as required and as per Specifications, complete all as specified and as directed.NOTE : Any Other Misc Items required at Site of Work even if not mentioned in the Scope of Work will deem to be include in the Quoted Unit Rate. |
| 22 | Supply, Installation, Commissioning & Testing Factory made (CPRI Certified/ Tested Manufacturer) Floor mounted Outdoor LT Panel of suitable Size, made out of 3.15mm (Outer) and 2.00mm (Inner) thick CRCA Steel Sheet with Angle Iron Frame Work and 4 No. Legs of ISA 50x50x5.0mm, Front and Rear Openings, AC 415 Volt, 50 Hz 3 Phase, 4-Wire, Totally Enclosed Self Supporting Structure/ Cubicle, Fully Compartmentalized type, Weather Proof, Dust & Vermin Proof, IP-65 Class Protection, Double Door type, having Bottom Cable Entry with suitable Cable Glands, Angle Iron Legs grouted in PCC 1:2:4 (20mm graded stone aggregates) Foundation Block with suitable mounting Arrangements for Bus-bars, Ammeter, Voltmeter, Changeover Switch, MCCBs with Slope Canopy at Top, Double Hinged Doors at Front with suitable Locking Arrangements and Internal Wiring with PVC insulated Solid Copper Conductor FRLSH Cable of Size not less than 6.0 Sqmm, Panel duly Powder coated and for Accommodating and including following Accessories:- |
| 23 | INCOMING :-(a)Aluminium Bus-bar 200 Amp rating suitable for Incomer & -04 No.Out-going MCCB(b)MCCB 25 Amp, 4 Pole, 415 Volt, 16 kA Breaking capacity, -01 No.(Ics = 100% of Icu)(c)Multi-function Panel Meters, Square type to Measure Single/ Three -01 SetPhase, Load Current, Frequency including necessary CT/PT of suitable ratio(d)LED Indicator Lamp (R-Y-B) (Set of Three)-01 SetOUT-GOING :-(e) MCB 32 Amp, 4 Pole, 415 Volt, 10 kA Breaking capacity-01 No.(f) MCB 32 Amp, DP, 230 Volt, 10 kA Breaking capacity -02 No. |
| 24 | EXTERNAL WATER SUPPLYM&L Construction Brick Masonry Valve Chamber of Size 90x90x90 Cm (Internal Dimension of Valve Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 3.15mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Chamber, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre, complete all as specified and as directed. |
| 25 | EXTERNAL ELECTRIFICATIONSM&L Cable Jointing Kit, Indoor/ Outdoor Joint, Heat Shrink type complete with Jointing Materials & Accessories suitable for 1100 Volt grade XLPE Armoured Aluminium Conductor Cable, Cross sectional Area 25 Sqmm to 50 Sqmm, 3½ Core, Providing Connection and Testing, complete all as specified and as directed. |
| 26 | M&L Cable Jointing Kit, Indoor/ Outdoor Joint, Heat Shrink type complete with Jointing Materials & Accessories suitable for 1100 Volt grade XLPE Armoured Aluminium Conductor Cable, Cross sectional Area 150 Sqmm to 185 Sqmm, 3½ Core, Providing Connection and Testing, complete all as specified and as directed. |
| 27 | Supply, Installation, Commissioning & Testing Factory made (CPRI Certified/ Tested Manufacturer) LT Panel, Outdoor of suitable Size, made out of 3.15mm (Outer) and 2.00mm (Inner) thick CRCA Steel Sheet with Angle Iron Frame Work and 4 No. Legs of ISA 50x50x5.0mm, Front and Rear Openings, AC 415 Volt, 50 Hz 3 Phase, 4-Wire, Totally Enclosed Self Supporting Structure/ Cubicle, Fully Compartmentalized type, Weather Proof, Dust & Vermin Proof, IP-65 Class Protection, Double Door type, having Bottom Cable Entry with suitable Cable Glands, Angle Iron Legs grouted in PCC 1:2:4 (20mm graded stone aggregates) Foundation Block with suitable mounting Arrangements for Bus-bars, Ammeter, Voltmeter, Changeover Switch, MCCBs with Slope Canopy at Top, Double Hinged Doors at Front with suitable Locking Arrangement including Louvers at Sides and Internal Wiring with PVC insulated Solid Copper Conductor FRLSH Cable of Size not less than 6.0 Sqmm, Panel duly Powder coated and for Accommodating and including following Accessories:- |
| 28 | INCOMING :-(a)Aluminium Bus-bar 200 Amp rating suitable for Incomer & -04 No.Out-going MCCB(b)MCCB 63 Amp, 4 Pole, 415 Volt, 25 kA Breaking capacity-01 No.(c)Changeover Switch 63 Amp, 4 Pole, Onload-01 No.(d)Multi-function Panel Meters, Square type to Measure Single/ Three -01 SetPhase, Load Current, Frequency including necessary CT/PT of suitable ratio(e)LED Indicator Lamp (R-Y-B) (Set of Three) -01 SetOUT-GOING :-(f) MCCB 40 Amp, 4 Pole, 415 Volt, 25 kA Breaking capacity-02 No.(01 No. Working & 01 No. Standby) |
| 29 | M&L Earthing Complete with Galvanised Earth Plate Electrode 600x600x6.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and Connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in Alternate Layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregates), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both Ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of Surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed.NOTE : All Joints should be joined by Exothermic Welding or Brazing. |
| 30 | LIGHTING ARRESTOR & CHEMICAL EARTHINGM&L Early Streamer Emission (ESI) Lightning Protection Air Terminal, complies with NFC-17-102 Standards. The Air Terminal should be capable to Collect the Ambient Electric Field and to should Emit the Upward Streamer with the defined gain in Time.Model to be selected for Class III Coverage for 107 Metre Radius of Protection. Model Storm Flash-60-(HSN code 8535) Made in Turkey. Radius of Protection is 107 Metre in Level II) Lighting Flash Counter Working Electro Mechanically without any Power Supply.Equipment should Count Lightning Strokes of 0.4 KA to 150 KA LS-LSR6) including Testing after Installation/ Completion, complete all as specified and as directed. |
| 31 | M&L GI Pipe 50mm bore (dia) Mast having 6.00 Meter Long and fixing/ grouting in Cement Concrete 1:2:4 (20mm graded stone aggregates) Base/ Foundation Block of suitable Depth as per Site requirement, complete all as specified and as directed.NOTE : Cost of Cement Concrete, Formwork, etc. will deem to be include in the Quoted Unit Rate. |
| 32 | M&L Lighting Strike Recorder as per Manufacture, complete all as specified and as directed. |
| 33 | S&F Copper Cable of Size 70 Sqmm, Single Core with Lugs, complete all as specified and as directed. |
| 34 | M&L Tri-pod Maintenance Free AES Gel Earthing with GI Pipe 50mm bore (dia), 3.00 Metre Long with BFC-50 KG+Bucket Cover complete as per Standard Specifications, complete all as specified and as directed. |