| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed. |
| 2 | M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound (Note :-WPC shall be measured & paid separately) |
| 3 | M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfacesin CM (1:4) and finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | Supply only Integral waterproofing compound.complete all as specified and directed. |
| 6 | M&L for preparation of the newly plastered surfacesof walls & applying two coatsdistemper oil- emulsion , white or tintedoverand including a coat of primer surfaces of wall complete all as specified and directed. |
| 7 | M & L for applying three coat of white wash on ceiling over new plaster surface. complete all as specified and directed. |
| 8 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces with smart painting tools complete all as specified and directed. |
| 9 | Providing and applying putty of 1 mm thickness over Old plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 10 | M&L for Preparation of old surfaces by complete removal of existing treatment and applying two coats of oil bound distemper over and includingone coat ofprimer on wallscomplete all as specified and directed. |
| 11 | M & L for applying one coat of white wash on ceiling over old decorated surface. complete all as specified and directed. |
| 12 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 13 | M & L or Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. |
| 14 | All as per item No.13 above but on vertical surfaces including 10mm thick backing coat of tiles in CM (1:3) complete all as specified and directed. |
| 15 | M&L for Non skid coloured plain/printed glazed tiles of size 300 x 300 x 6mm to 7 mm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 16 | M&L for coloured plain/printed glazed tiles of size 300 x 450 x 7 mm, on vertical surfaces such as skirting, dado etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 17 | M&L Granite slab work 18-20mm thick in floors steps, cooking platforms and likeincluding pointing in white cement with admixture of pigment to match with granite shade over & including screed bed 15mm thick in CM 1:6 including cutting recess opening for the sink portion and embedding complete all as specified and directed.(Note : No deduction shall be made for opening of sink portion, shall deemed to be included in the quoted rate) complete all as specified and directed. |
| 18 | S&F sinks without drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes ; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe, overall size 495mmX420mm bowl size 410mmX330mmX160mm complete all as specified and directed. |
| 19 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and othersimilar situations complete all as specified and directed. |
| 20 | M&L for preparation of old steel painted surfaces exc 10cm width or girth and applying one coats of synthetic enamel paint ccomplete all as specified and directed. |
| 21 | Taking down chowkats or frame with shutters (without taking off shutters from the frame) n exc 1.5 sqm each complete all as specified and directed. |
| 22 | Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 Sqm each complete all as specified and directed. |
| 23 | Taking down shutters of any description and in any positionexceeding 1 sqm & not exceeding 2 sqm each complete all as specified and directed. |
| 24 | S & F 35 mm thick factory made IInd class hard wood (not less than Hollock wood) glazed and skeltonshutters open rebated and prepare to receive glass / gauze etc (without sash bars) edges of framing plain chamfered or rounded, fitted with moulded beads both sides for securing glass etc {size of members of shutters as specified in clause 8.24 (a) of section 8 of SSR - I} supplied and fitted to chowkat complete all as specified and directed. |
| 25 | S&F 2nd class hard wood factory made plain framed panelled door shutters 35mm thick (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides. The size of rail and stiles as per IS:1003 (Part I), Klin seasoned and chemically pressure treated.complete all as specified and directed. |
| 26 | S&F 12 mm thick prelaminated particle board, Exterior grade prelaminated and both sides with decorative choice laminationscomplete all as specified and directed. |
| 27 | S & FPowder coatedAluminium alloy sections sliding windows with frames Series-C (20mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips,shutters with tinted glass 5mm thick and stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. |
| 28 | M & L forPowder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors , windows , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 29 | M&L for Powder coated (minimum thickness of powder coating 50micron) Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. Note : Panel filling i.e.. glass, fibre sheet, board, wire mesh etc. shall be measured and paid for separately. |
| 30 | S&F 4.8 mm thick tinted glassof selected qualityin square not exceeding 0.5 sqm in each pane, fixed to aluminiumframe with and including suitablerubber beadingcomplete all as specified and directed |
| 31 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed. |
| 32 | S&F butt hinges 100mm size medium weight cold rolled mild steel complete all as specified and directed. |
| 33 | S&F for butt hinges 100mm size medium weight stainless steel .complete all as specified and directed. |
| 34 | M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed. |
| 35 | S&F Aluminium anodised barrel tower bolt of extruded section 200 mm sizecomplete all as specified and directed. |
| 36 | S&F stainless steel sliding door bolt with hasp and stapple (bolt type) and fixing clips of sheet cast or extruded section with fixing bolts and sliding bolt of extruded section 300mm length & dia not less than 12mm with & including 6 Nos of bolts complete all as specified and directed. |
| 37 | M&L for Preparation of old painted surface of wood and wood based materialany description and in any position over 10 cm width or girth andapplying one coat of synthetic enamel paint complete all as specified and directed. |
| 38 | M&L surface preparation of new wooden surfaces of any description, not otherwise described, over and including 10cm width or grith and apply two coat of synthetic enamel paint over one coat pink primer complete all as specified and directed. |
| 39 | S&Faluminium powder coatedventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members andhalf portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified and directed. |
| 40 | S&F in repairs20mm dia powder coated decorative typecurtain rod incl brackets complete all as specified and diretced . |
| 41 | S & F in repair vitreous china wash basin counter top, white flat back , size 450mmx300mm with and including Waste fittings, brass, chromium plated forbasins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated,fancy type,pillar tap,15mm bore,screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed. (Note: MAKE - CERA/PARRYWARE/JAQUAR) |
| 42 | S&F in repairs 15mm dia Bib taps cast copper alloy,with Chromiun plated crutch or butterfly handle screwed down,for iron pipe or brass ferule complete all as specified and directed.(Note: MAKE -CONFIRMING TO JAQUAR CAT PART-No. APR -101037 OR EQUIVALENT) |
| 43 | S & F in repairs 15mm dia angle valves, Chromium plated crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipes or for unions complete all as specified and directed.(Note: MAKE -CONFIRMING TO JAQUAR CAT PART-No. STE -107053 OR EQUIVALENT) |
| 44 | S & F in repairs 15mm size PVC connections with PTMT nuts of length 450 mm.complete all as specified and directed. |
| 45 | M&L in repairs 40mm dia Low density poly ethylene pipes(LDPE) of pressure rating 6 Kgf/cm2fixed complete to wall, ceiling or in floors etc complete all as specified and directed. |
| 46 | S&F in repair 1800mmx800mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 47 | M&L cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 48 | S&F for Rotational moulded polyethylene water storage tank(white) of 1000 liter capacity (cylindrical vertical with closed top incl float valve) hoisted and fixed in position all as specified and directed. |
| 49 | M&L for cutting grooves in brick wall, 75 mm wide and 65 mmdeep and shaping horizontal face of groove with cement mortar 1:3 to ends of landings, steps, cills sunshades, shelves lintels etc complete all as specified and directed. |
| 50 | M&L for cutting holes or through PCC block / RCC wall built in CM and making good in CM 1:3 or cement concrete 1:2:4 type B-1 as required, superficial area exc 150 sqcm but n.exc 400 sqcm complete all as specified and directed. |
| 51 | Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) internal dia of pipe in 75mm set in cement mortar complete all as specified and directed. |
| 52 | Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) internal dia of pipe in 110mm set in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 53 | S&F for 110mm PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in trenches / wall fixedor in floors complete all as specified and directed. |
| 54 | S&F 75 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid in trenches /wall fixedcomplete all as specified and directed. |
| 55 | S&F 75mm dia PVC (SWR)bendsany radius with access door.complete all as specified and directed. |
| 56 | S&F 110mm dia PVC (SWR)bendsany radius with access door.complete all as specified and directed. |
| 57 | S&F for PVC (SWR) floor trap long body type, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 58 | S&F for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 59 | M&L PCC 1:2:4 type B1 using 12.5 mm graded aggregate as in hold fast, cill etc with necessarry form work complete all as specified and directed. |
| 60 | Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 15mm dia, any grade,of any description or in any position including fittings complete all as specified and directed. |
| 61 | Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 20mm dia, any grade,of any description or in any position including fittings complete all as specified and directed. |
| 62 | Supplying and laying15 mm outer dia Unplasticised PVC SDR 13.5 and plain CPVC SDR 11 fittings pipes fixed complete to walls, ceilings or in floors etc., any type of pipe etc in required length complete all as specified and directed. |
| 63 | Supplying and laying20 mm outer dia Unplasticised PVC SDR 13.5 and plain CPVC SDR 11 fittings pipes fixed complete to walls, ceilings or in floors etc., any type of pipe etc in required length complete all as specified and directed. |
| 64 | M&L for brushing neat cement slurry with 3 Kg/Sqm of cement complete incl complete removal of existing roof treatment all as specified and directed. |
| 65 | M&L 25mm thick PCC of type B-1, 1:2:4 (20mm graded stone aggregate) for padding complete all as specified and directed. |
| 66 | M&L Rendering 10 mm thick of CM 1:4onconcrete roofsurfaces is to be finished even and smooth without using extra cement with mixing water proofing compound @3% by weight.complete all as directed. |
| 67 | M&L in repairs App based polymeric membrane minimum weight 3.5 Kg/Sqm and Minimum 3 mm thick reinforced with polyester non wove fabric (Wt. not less than 150 gms/Sqm land on primed surface by torched application completed all as specified and directed. |
| 68 | M&L cleaningsurface and applying two coats of aluminium painton roof or vertical surfaces complete all as specified and directed. |
| 69 | Material & labourfor machine cut kota stone slab size as in flooring, stair case landing. treads of steps, 18-22mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeincluding 20mm thick screed bed or bedding in cement mortar 1:6 all as specified and directed. |
| 70 | Material & labourfor machine cut kota stone slab sizeas in skirting, dado, vertical surfaces etc, 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing includingbacking coat 15mm thickcement mortar 1:3 complete all as specified and directed. |
| 71 | S&F in repair of PVC cabinet size 650 x 400mm, comprising of looking glass, space for bath soap, shampoo, tooth brush and paste, handle towel rail complete allas specified and as approved of any fo floowing makes :- HINDWARE / CERA / NEYCER / PARRYWARE/CLASSICcomplete all as specified and directed. |
| 72 | M&L 75 mm thick PCC 1:3:6 type D-2 (using 40mm graded stone aggregate) as in as in sub baseall as specified and directed. |
| 73 | M&L for providing prrecast cement concrete Type B1 1:2:4 (20 mm graded aggregate) in appex stone/kerb stone with plain fair faces including chamfers, weathering throting etc and set in cement mortar 1:4 complete with joints to math size and shape as approved complete all as specified and directed. |
| 74 | M&L sand filling 50 mm thick under floor/over floor or in foundations including well ramming complete all as specified and directed. |
| 75 | M&L 60 mm thick coloured interlocking PCC tiles in approved design/colour setlaid over compacted sub soil / sand all as specified and directed. |
| 76 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise spefifically provided for complete all as specified and directed. |
| 77 | M&L for removal of existing loose damage concretye, dust, oil, paint, grease, etc from structural member like roof slab, beam, column, chajja, etc exposed fully if any corroded steel in the repair area and remove all the scale and corrosion deposite and applying Dr fixit rust removal and Epoxy Zinc Primer over the cleaned steel bars if and pour the mixed Dr fixit micro concrete into a watertight shuttering after primed by one coat of Dr fixit Epoxy bonding. Thickness or depth of an area n. exc 10cm and all as per manufature instruction as specified. (Note - The rate included S&F of addition reinforcement bars if any required.) |
| 78 | S&F Window Canopy which is made with a durable polycarbonate/Glass/ fiber/acrylic sheet and steelbrackets for roof covering/cladding to wall, fixed with hold fast complete all as specified and directed.(Note :As per Design approved by GE) |
| 79 | M&L for preparation of new steelsurfaces of any descriptionover 10 cm width / girth& applying 2 coat of synthetic enamel paintcomplete all as specified and directed. |
| 80 | Providing & applying Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp :1.SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non- moving cracks having width upto 5 mm must be filled with Polymer based crack filler.2 APPLICATION: Apply the first coat of Dr Fixit Dampguard Classic with a paintbrush directly on the prepared surfaces by mixing ( 1 part base:1 part hardner: 1 part of water) . Allow to dry for a minimum 2-3 hrs. Apply one part of DAMPGUARD mixed chemical and 2 parts of OPC white cement/Birla Putty and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Dr Fixit Dampguard Classic on the entire surface and allow the surface to air cure 48 Hrs proceeds to paint. |
| 81 | M &L mild steel bars conforming to Fe 290 Gde E-165 as in guard bars ,ladder or similar worksincluding welding etc complete all as specified and directed. |
| 82 | Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and directed. |
| 83 | M&L for Pre-cast cement concrete block masonry (Type C1, 1:3:6, 20mm aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed. |
| 84 | S & F of Steel work in tubular trusses/purlin including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 85 | S & F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 86 | Providing ,supplying and fixing Modular false Ceiling with USG KNAUF PVC Laminated Gypsum Tile white Sand 7 mm with aluminium foil Back 595X595 mm SQ Edge on true line Suspended with USGKNAUF Unilite GI Powder coated Plain White 32x24 mm T Grid System with all necessary accessoriesas per drawing and instruction on site all as directed. |
| 87 | M&L for Shootcreting Average thickness 25-30 mm in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 kg/cum on M-25) concrete having the specified minimum characteristics compressive strength (with ordinary Portland cement, coarse and graded stone aggregate of 6 mm maximum size in proportion as per design criteria) or Ready to use Micro concrete mortar including the cost of centering and shuttering at edges and corners etc as directed by Engineer in charge including chipping of unsound/weak concrete material 25mm average thickness from slabs /columns etc with manual chisel or standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc including removal of rust by applying approved rust removerhemical & the coating with Dr fixit Epoxy zinc Primer@6sqm/ltr at DFT of 100 microns as per specification ,applying the SBR Latex based bonding agent on each layer of the shootcreating work of Dr Fixit Pidicrete URP on the entire surface all as per direction. |
| 88 | Providing & fixing hard drawn MS steel wiremesh 80mm x 25mm with 3mm dia wire with Heavy duty nails, Fixing the mesh on the ceiling before shotcreting work. all as per direction. |
| 89 | S&F 18 mm thick prelaminated PVC Cheluka ply prelaminated one side with decorative choice lamination and other side plain fixed with screws to PVC celuka ply works all as directed and as per manufacture instructions Make : Rajshree plasticwood |
| 90 | S&F brass Handle fabricated type polished of Size 100 mm complete all as specified and directed. |
| 91 | S&F for butt hinges 100mm size medium weight stainless steel .complete all as specified and directed. |
| 92 | M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfacesin CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed. |
| 93 | M&L for Rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates all as specified and directed. |
| 94 | Dismantling asbestos cement/PPGL Sheet (corrugated/semi corrugate/Plain, etc.,) sheets in roof covering including wooden batten, wooden trusses, complete all as specified and directed. |
| 95 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge / roof covering/ cladding to wall, fixed with self tapping screws as specified all as specified and as directed. |
| 96 | S&F in repair Tee grid suspension system of size 600 mm x 600 mm type-1 made out of roll framed hot dipped galvanised steel zince coated of not less than 120 gm/Sqm, main runner 0.3 mm thick of section24 mm x 33 mm crross runner 0.30 mm thick of section 24 mm x 25 mm, wall angle shall be 0.63 mm thick of section 24 mm x 24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod, system exposed portion shall be pre painted polyester coated in off whitee/white in colour complete with material, fixing, jointing etc., with Coloured textured designer ceiling board 4mm thick of size 595 x 595 mm fixing with screws/clips complete all as per manufacturers instructions and direction. |
| 97 | S&F for butt hinges 100mm size medium weight stainless steel complete all as specified and directed. |
| 98 | M & L for non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.complete all as specified and directed. |
| 99 | All as per item No.98 above but on vertical surfaces including 10mm thick backing coat of tiles in CM (1:3) complete all as specified and directed. |
| 100 | Dismantaling and taking down copper / aluminium point wiringany type / size complete with removing all connection and accessories such asswitches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface complete all as specified and directed. |
| 101 | Taking down old and unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface all as directed. |
| 102 | Taking down old and unsrevicablesheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB\"s , insulator etc complete after removing all connection and making good the disturbed surface all as directed. |
| 103 | M&L for Point wiring complete with FR PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,1.5 Sqmm (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC conceled conduit medium grade ,minimum 20 mm dia, ISI Marked,with sutaible size of 1 to 8 module metal flush boxes and back plate for mounting of modular switches/socket and regulators and including modular fornt plate with all acessories complete all as specified and directed. . |
| 104 | (a)One light point controlled by one way one switch SP 5 Amps ,240 V. |
| 105 | (b)One ceiling/exhaust fan point controlled by one way one switch SP 5 Amps, 240 V. |
| 106 | (c)One switch socket outlet 3 Pin, 5 Amps, SP on independent board. |
| 107 | (d)One switch socket outlet 3 Pin, 5 Amps, SP on sameboard. |
| 108 | All as per the above item No 103 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet. |
| 109 | S&F modular switch one way 6 Amps , 1 module type complete all as specified and directed. |
| 110 | S& f modular socket , 6 Amps , 2/3 pin combined 2 module complete all as specified and directed. |
| 111 | S& f modularswitch socket combination, 6 Amps / 16 Amps , 2/3 pin combined 2 module complete. |
| 112 | S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete all as specified and directed. |
| 113 | Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting uptoPVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirementand 2 Nos ofround or square PVC bolck for fixing of FTL fitting complete all as per directed. |
| 114 | Supply & fixing modular fan regulatorstep type , 1 module complete all as specified and directed. |
| 115 | M&L for sub main wiring with two runs of 6 Sqmm (2x6 sqmm )1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductorcableconfirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 6 Sqmm (1x6 sqmm )single core FRLS PVC insulated unsheathed copper conductor cableas earth wire complete all as specified and directed. Note:- 2 runs of 6 Sqmm ,one run of 6 Sqmm( 2x6 sqmm + 1x6 sqmm ) cable and one meter of conduit will be measured as one unit /Rm. |
| 116 | M/L for Sub main wiring with 2 runs of PVC FRLS insulated unsheathedmulti stranded single core copper conducter 4 Sqmm drawn through PVC concleadconduit including accessaries with 4sqmm PVC insulatedearth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiringand connecting up ,complete all as specified and directed. Note: (a)2 runs of cable and one run earth wire and conduit will be measured as one length.(b) cutting chases in tothe wall of any thickness ,fixing suitable size conduit and drawingcopper conductor and and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed. |
| 117 | M&L for sub main wiring with four runs of 6 Sqmm (4x6 sqmm )1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductorcableconfirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 6 Sqmm (1x6 sqmm )single core FRLS PVC insulated unsheathed copper conductor cableas earth wire complete all as specified and directed. Note:- 4 runs of 6 Sqmm ,one run of 6 Sqmm( 4x6 sqmm + 1x6 sqmm ) cable and one meter of conduit will be measured as one unit again. |
| 118 | S&F sheet metal enclosures fordistribution board when MCB to be used SPN ( Single pole and neutral ) 8 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door typecomplete all as specified and directed. |
| 119 | S&F in MCB TPN, 63 Amps,415 Volts, rupturing capacity 10 KA.\"C\" Series complete. |
| 120 | Supply & fixing MCB DBs TPN vertical, Double door, with provision of MCCB as incommer , 4 way, flush in wall, including civil work to match the disturbed surface with existing complete all as specified and directed. |
| 121 | S&F MCCB of capacity 100 Amps , 415 Volts, rupturing capacity 16 KA complete all as specified and directed. |
| 122 | S&F MCB SPN,40 Amps, 240 Volts, rupturing capacity 10 KA.\"C\" Seriescomplete all as specified and directed. |
| 123 | S&F MCB SP 40Amps, 240 Volts, rupturing capacity 10 KA \"C\" Series complete all as specified and directed. |
| 124 | S&F MCB SP, 5 to 32Amps, 240 Volts, rupturing capacity 10 KA \"C\" Series complete all as specified and directed. |
| 125 | M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nutsall shown in electrical plate No.3 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnelwith watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.Note :- (i)Earthing shall be tested as specified incasul 19.137 of SSP PART - I 2009 , to the entire satisfication.(ii) On teting after complataion of earthing,if the desired earth resistance is not obatined the earthing wiil be re done by thecontractor at his on risk and cost to the entire satisfaction. |
| 126 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame a All as specified and directed. |
| 127 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep copper wound 100% aluminium blades with tickness1.0mm. Min air delivery 210 CFM with service value of BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 128 | Supply and fix in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 25 sqmm 4 core complete all as specified and directed |
| 129 | Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified. |
| 130 | Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 131 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specified and directed. |
| 132 | M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed. |
| 133 | Supplying and laying un-reinforced precast concrete cable cover class LV Type 1, flat, size 250mm x 150mm x 40mm complete. Complete all as specified and directed. |
| 134 | Supply and laying GI tube light grade 50 mm bore complete. Complete all as specified and directed. |
| 135 | Supply and lay pipe uPVC pipeincluding fittingsof size 50 mm (2.0\") dia complete all as specified and directed. |
| 136 | Supply and lay pipe uPVC pipeincluding fittingsof size 25 mm (1.0\") dia complete all as specified and directed. |
| 137 | supply and fix ball valve25 mm dia including all fittings all as specfied and directed. |
| 138 | Supply and fixing electric water heater, storage type steel body withinner tank and heating element upto 1.5 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.complete all as specified and directed. |
| 139 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete,complete all as specified and directed. |
| 140 | S & F in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 voltswith and including one MCB, SP, 20A, 240 Volts as per all as specified and directed. |
| 141 | Taking down old and unsrevicablesheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB\"s , insulator etc complete after removing all connection and making good the disturbed surface all as directed. |
| 142 | Supply and fix desert cooler, plastic body electric driven (single phase), having nominal air flow capacity ofmore then 4000 CFM ,Honeycomb cooling padsdesign, ice chamber,water level indicator,Four way air deflection,Easy Mobility on wheels including all necessary arragement complete all as specified and directed. |
| 143 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail