| 1 | Supply, laying, fixing and testing in replacement of heavy duty MS Pipe conforming to IS: 1239/3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc.including welding, cutting, and grindingworks, laidin trenches, or fixing in wall, ceiling andfloor complete and making good the disturbed surface similar to existing excavation & providing cement concrete blocks as supports and painting with two or more coats of synthetic enamel paint of post office red coloras per IS- 10221, in and including disconnected/dismantaling and taking out of rusty/damaged MS pipes complete all as specified and as directed of following sizes as required:- |
| 2 | 150 mm. dia |
| 3 | 100 mm. dia |
| 4 | 80 mm. dia |
| 5 | 65 mm. dia |
| 6 | 50 mm dia |
| 7 | Supplying, fixing andtesting in replacement of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze, ISI marked complete with matching flange, nuts, bolts, washers, gaskets and conforming to IS: 780complete all as specified and as directed of following sizes as required:- |
| 8 | 150 mm dia |
| 9 | 100 mm dia |
| 10 | 80 mm dia |
| 11 | Supplying, fixing and testing in replacement ofdouble flanged butterfly valve of PN 1.6 rating, CI , gear/hand lever operated,with soft seated wafer, bronze and ss 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095complete all as specified and as directed of following sizes as required. |
| 12 | 150 mm dia |
| 13 | 100 mm dia |
| 14 | 80 mm dia |
| 15 | Supplying, fixing and testing in replacement ofnon return valve flange type of PN 1.6rating,ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 complete all as specified and as directed of following sizes as required. : |
| 16 | 150 mm dia |
| 17 | 100 mm dia |
| 18 | 80 mm dia |
| 19 | Supplying, fixing and testing in replacement of unserviceable gun metal branch pipe, short type, instantaneous pattern to suit hose delivery coupling of size 63 mm bore complete with gun metal solid jet nozzle of 15 mm nominal size confirmin to IS:903 complete all as specified and directed. |
| 20 | Supplying, fixing and testing in replacement of unserviceable fire hydrant fanged type landing valve, oblique type, singleheaded outlet with hose copling adaptor of size 63 mm bore made of gun metal with female mouth and cast iron wheel and instantaneous spring lock, blank cap with chain confirmin to IS:5290 complete all as specified and directed. |
| 21 | All as per item No6above but double headed outlet type |
| 22 | Repairof sluice valve in positiondouble flanged cast iron for repair , replacementof unserviceable components such as of bonnet, gland packing ,seat , disk gasket nut bolts and spindal with nutafter repair grending ,resurfacing refixing the valve in position andtesting complete all as specified and as directed of following sizes as required:- |
| 23 | 150 mm dia |
| 24 | 100 mm dia |
| 25 | 80 mm dia |
| 26 | M& L for servicing ofdiesel engine generator (Make -kirlosker ) direct coupling with horizontal mounted multi stage centrifugal pump (fire fighting pump capacity 75 HP model-DSM 100/36)servicing and maintenance byOEM/ authorised dealer cleaning and servicing of fuel supply assemblycoolent assembly, AVR unit,control panel, incl repacement of minor spare parts viz. air filter ,oil filter , fuel filter ,battery terminalscomplete includingservicing ofCIimpeller horizontal split casingpump with replacement ofold bearing set gland packing lubricatiting all moveable parts all complete all as specified and directed. Note:- The contractor willattend breakdownimmediately in case of generator gets offroad or anyother fault occured. |
| 27 | Supplying, fixing and testing in replacement of unserviceable swinging hose reel comprising ofply rubber hose of size 20mm(3/4\"), 30 m long tested with 25kg/cm²/350 psi bursting pressure with wall mounted mild steel pressel reel with 180º angle swinging with non-jamming contolling handle which shall stay at the ON/OFF position as set, wall bracket with \"U\" shaped reel carrier made of CI of post office red colour finished in and including gun metal noel and shut off ball valve, heavy duty confirming to IS: 884 and ISI markedcomplete all as specified and directed. |
| 28 | Supplying and installin replacementyard fire hydrant box, outdoor type ofinternal size not less than 120 cm x60cm x 45 cm made out of 18 SWG thick CRCA mild steel sheet, factory made, totally enclosed with front side hinged openable cover with locking arrangement and pad lock duly painted with two coat of red post office colour synthetic enamel paint oninside and outside surface comprising 4 mm thick glass window of sizenot less than 100 X 45 cm on front side openable cover inscribed with word \"FIRE\" (5 inch size) with post office red synthetic enamel paint. The box to be installed on brick pillar foundation with suitable size of MS foundation bolt grouting in and including dismantling corroded/worn out yard fire hydrant box from brick pillar foundation complete all as specified and as directed. |
| 29 | Supply & fixing in replacement of broken glass windowsize not less than 100 cm x 45 cmof4 mm thick in yard fire hydrant box including replacement of unservicable rubber beeding of suitable size complete all as specified and as directed. |
| 30 | Supply & fixing in replacement of broken glass windowsize not less than 110 cm x 110 cmof4 mm thick inhydrant box including replacement of unservicable rubber beeding of suitable sizecomplete all as specified and as directed. |
| 31 | Supplying and fixing in replacement of unserviceable internal hydrant rubber washer 4mm thick of size 12mm inner diameter and 72 mm outer diameter complete all as specified and as directed. |
| 32 | Supply & fixing in replacement of unserviceable taflon/nylon washer with outer dia 19mm and inner dia 9 mm and thichness 3mm complete all as specified and as directed. |
| 33 | M&L repair/servicing of air vessel (size 300mm dia, 2 m height) by disconnecting water pipe conection ,opening air valve cleaning of inner/outer surface for proper functioning after repairing and servicingtesting for proper functioning including painting with synthetic enamel paint of post office red coloured over two coat of red oxide primer on outside complete all as specified and as directed. |
| 34 | M&L for fittings for flanged pipes such as Bends, Tapers, Tee Pieces (Single & double branch) any type and angle/radious and straight connecting pieces but all ends flangedcomplete all as specified and as directed. |
| 35 | M&L for painting up to 200 mm bore New MS/GI pipe with one coat of red oxide primer and two coats of red post office synthetic enamel paints on all external steel surface after throughly cleaning/scraping of old paints, rust and scale etc.before applying the primer all complete all as specified and as directed. |
| 36 | M&L for painting of MS fire hydrant box Indoor and outdoor type of internal size not less than 97x105x60cm after throughly cleaning/scraping of old paints, preparation of surfaces with emery paper as per existing colour code duly painted with two coat of red post office colour synthetic enamel paint in surface over a coat of red oxide primer complete all as specified and as directed. |
| 37 | M&L painting of pump motor complete set including base plate, of capacity 75 HP motor with two coat of synthetic enamel paint of existing colour after preparing surfaces all complete all as specified and as directed. |
| 38 | Supply and fixing in replacement of dial type pressure gauge 4\"dial 0-14 kgs rating including necessary fittings complete all as specified and as directed. |
| 39 | M&L for cleaning of fire pipe lineof size 80 mm to 150 mm passing through any type of duct/trench/wallsize not less than 1.0 mtr width and 1.5 mtrdepth by using high pressure waterjet pump for removing/taking up dirty water alongwith sludge including cleaning of valve chamber/pit of any size by scrubbing of the internal surfaces and refixing of MScover complete all as specified and directed.(Note:- Earth workif required at site the same will be measured under relevant item of sch A) |
| 40 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep in any type of PCC/Hard/Dense soil complete all as specified and directed. |
| 41 | Returning filling including leveling,watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed. |
| 42 | Removing the excavated materials not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level complete all as specified and directed. |
| 43 | Disconnecting of electric connectionand taking out pumpmotor from 75 HP 3 phase 415 voltpump set,transporting the same work shop opening the motor, removing burnt winding and cleaning winding slots and rewinding of motor using suitable gauge/ sizewith supper enamelled copper wire, replacinginsulation paper of class Fand fire proof sleeves, varnishing complete, oiling, greasing, replacing oldrear/ frontbearings with new and reassembling complete motor includingtestingat site complete all as specified and directed. |
| 44 | All as per item No 26 here in above but for motor pump set up to 5.5 HP motor pump set |
| 45 | M&L for taking out electrical driven motor suitable for75 HPpump setafter disconnected all electrical and water connection and disassembling form base and uncoupling motor shaft coplingand taking and transport to work shop & opening carefully and servicing complete with replacing of bushes/bearings, motor crank set, shaft seal assembly , rubber gasket, nut, bolt & washerspainting internallywith synthetic enamell paint and re-fixing it in original position and making out all electrical and water connection after necessary prepartion incl testing & commissioning complete all as specified and directed. |
| 46 | All as per item No 28 above but for motor pump set up to 5.5 HP motor pump set complete all as specified and directed. |
| 47 | M& L repair and servicing of 75 HPpumpsetby dismantling at site or transport to work shop as required by opening the pump,replacement unserviceable both side bearing and bushes, shaft seal assembly andworn out nut and bolts gaskets, machining of shafts, over hauling& greasing of pump and reassembling completewithtestingmotor at site complete all as specified and directed. |
| 48 | All as per item No 30 as above butup to 5.5 HP pump capacity complete all as specified and directed. |
| 49 | Supply and Fixing in replacement of star delta strater in sheet -steel enclosuretypewith suitable power contactor ,single phase preventorand relayfor pump motor rating5.5 HP 3 phase 415 Volt 50 Hz with suitablerelay range complete all as specified and directed. |
| 50 | Supply only front bearing for 75HP motor forbearingsuitable / existing sample complete all as specified and directed. |
| 51 | Supply only rear end bearing for 75 HP motor forbearingsuitable / existing samplecomplete all as specified and directed. |
| 52 | S & F in repairtyre couplingsuitable for 75 HP motor setwithexisting alignementall as specifiedand directed |
| 53 | Supply and fixin repair 3 pole power contactor 2 NO +2 NC ML 6 three phase, AC 440 volts, 50Hz, , of 110 Amps AC-1, 110 Amps AC-3. complete all as specified and directed. |
| 54 | Supply and fixin repair 3 pole power contactor MNX 80AC-1 rating 80 AandAC 3 rating 100 Athree phase, AC 440 volts, 50Hz, complete all as specified and directed. |
| 55 | Supply and fixin repair 3 pole power contactor MNX 35AC-1 rating 32 AandAC 3 rating 45 Athree phase, AC 440 volts, 50Hz, complete all as specified and directed. |
| 56 | Supply and fixin repair 3 pole power contactor MNX 25AC-1 rating 25 AandAC 3 rating 45 Athree phase, AC 440 volts, 50Hz,complete all as specified and directed. |
| 57 | Supply and fixin repair ST timer 100 range 3-30 Sec coil voltage 160-500 Volt AC complete all as specified and directed. |
| 58 | Supply and fixin repair thermal overhead relay MN-5 with start and off/reset of Amps range Relay 66-110A 415V AC Class complete all as specified and directed. |
| 59 | Supply and Fixing in replacement of MCCB 250Amp breaking capacity 36 KA , 4 pole, 415 volts, 50 Hz complete all as specified and directed. |
| 60 | Supply and Fixing in replacement of MCCB 100Amp breaking capacity 16 KA , 3pole and neutral , 415 volts, 50 Hzcomplete all as specified and directed. |
| 61 | Supply and fixin repair rubber gland packing suitable for sluice valve 200/150mm dia complete all as specified and directed. |
| 62 | Supply and fixin repair rubber gland packing suitable for sluice valve 100/80mm dia complete all as specified and directed. |
| 63 | M & L for repair of NRV of size 200/150mm flanged type by opening and cleaning inner plate spindle replacement of6mm thick rubber gasket, MS nuts, bolts and washers after repairing refixing the same in existing position complete all as specified and directed. |
| 64 | M&L for repair of leakage fire fighting distribution pipe line80 mm bore to 150 mmborebycutting of existing linefindingleakageand repair with suitable jointing materials complete including necessary exavation,returning filling, removing etcin any type of soil complete all as specified and directed.Note -:T&P and fittings if required shall be inclusive in qouted rate. |
| 65 | Supplying, fixing and testing in replacement of unserviceable synthetic fibre circular woven seamless reinforcement jacketed coupling with type- II (reinforced rubber lined type), flexible fire hosemade of 100% synthetic yarn, circular shaped of size 63 mm bore x 15 mtr long, complete with gun metal coupling of 63mm, with multi serrated tail and double instantaneous sprin lock arrangment comprising of heavy duty pair of gun metal male and female parts, hydralically crimped to hose with rubber cap washer and copper binding wire confirming to IS: 903 and ISI markedcomplete all as specified and directed. |
| 66 | Supplying, fixing and testing in replacement of unserviceable swinging hose reel comprising ofply rubber hose of size 20mm(3/4\"), 30m long tested with 25kg/cm²/350 psi bursting pressure with wall mounted mild steel pressel reel with 180º angle swinging with non-jamming contolling handle which shall stay at the ON/OFF position as set, wall bracket with \"U\" shaped reel carrier made of CI of post office red colour finish in and including gun metal noel and shut off ball valve, heavy duty confirming to IS: 884 and ISI markedcomplete all as specified and directed. |
| 67 | Supplying and fixing in replacement of unserviceable internal hydrant rubber washer 4mm thick of size 12mm inner diameter and 72mm outer diameter complete all as specified and directed. |
| 68 | S&F in replacement of battery 12V 180 AH including suitable battery lead complete all as specified and directed. |
| 69 | Supplying and installin replacementyard fire hydrant box, outdoor type ofinternal size not less than 800mm X 600mmX 250mm and 60 cm width, made out of 18 SWG thick CRCA mild steel sheet, factory made, totally enclosed with front side hinged openable cover with locking arrangement and pad lock duly painted with two coat of red post office colour synthetic enamel paint on outside surface and white colour paint on inside surface over a coat of red oxide primer comprising 4 mm thick glass window of sizenot less than 76 X 76 cm on front side openable cover inscribed with word \"FIRE\" (5 inch size) with post office red synthetic enamel paint. The box to be installed on brick pillar foundation with suitable size of MS foundation bolt grouting in and including dismantling corroded/worn out yard fire hydrant box from brick pillar foundation complete all as specified and as directed. |
| 70 | M&L for dismantling and taking down corroded/worn out base frames/pit covers, any type of water supply/fire fighting installations and supply and fix new base frames/pit covers. MS angle iron frame /MS plates/MS flat or round bars including welding work,duly painted with two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed. |
| 71 | M&L for making insertion under road without cutting of road for laying of MS/GI pipe line up to 150 mm bore by using mechanically operated machine complete all as specified and directed.Note :-(i) Works are to be carried out as and where required.(ii) All T&P item/Scap foldingas required at site will be arranged by the contractor at no extra cost. |
| 72 | M & L in replacement of fire fighting stand post made out of 40 mm GI pipe of size 1.5mtr x 1.0mtr and 1.0 mtr high above the ground level incl cutting, welding and painting in frame and plinth protection of 0.6x0.6x0.3 mtr with hanging hooks 4 for hanging of sand buckets/4 fire extinguiser incl painting with red/post office red colour Complete as directed. |
| 73 | M & L for fire bucketmade out of 20 SWG GI sheet 10.0 Ltr capacity incl painting with red colour enamel paint. complete all as specified and directed. |
| 74 | M & L in replacement of fire beater with bamboo 10’ long (02 Nos) incl painting with red coloured complete all as specified and directed. |
| 75 | M & L in replacement of fire Hook 10’ long (02 Nos) incl painting with red coloured complete all as specified and directed. |
| 76 | M&L for cleaning of underground/semi underground sump by taking out all sludge, silt from bottom and cleaning all inside walls with wire brush and brooming the walls and top ceiling/roof including washing the walls with fresh water mixed with bleaching powder and draining out complete sludge, silt etc from bottom of the sump and applying one coat of lime wash for the UG sump of capacity upto 25,000 gallons complete all as specified and directed. |
| 77 | M&L for servicing of diesel engine generator (Make-Kirloskar) direct coupling with horizontal mounted multi stage centrifugal pump (fire fighting pump capacity 72 HP Diesel engine type - RB66TO) as per prescribed in repair servicing and maintenance by OEM/authorised dealer cleaning and servicing of fuel supply assembly coolent assembly, AVR unit, control panel incl replacement of minor spare parts viz air filter, oil filter, fuel filter, battery terminals complete including servicing of CI impeller horizantal split casing pump with replacement of old bearing set gland packing lubricating all moveable parts complete all as specified and directed.(Note:- The contractor will attend breakdown immediately in case of generator gets off road or any other fault occured. |
| 78 | M&L for painting of pump, motor complete set including base plate, of capacity 60 HP motor with two coat of synthetic enamel paint after preparing surface complete all as specified and directed. |
| 79 | Disconnecting of electric connection and taking out pump motor from 60 HP 3 phase 415 volt pumpset, transportating the same work shop opening the motor, removing burnt winding and cleaning winding slots and rewinding of motor using suitable gause/size with super enamelled copper wire, replacing insulation paper of class F and fire poor sleeves, varnishing complete, oiling, greasing, replacing old rear/front bearing with new and reassembling complete motor including testing at site complete all as specified and directed. |
| 80 | All as per item No-62 above but for motor pump set up to 7.5 HP motor pump complete all as specified and directed. |
| 81 | All as per item No 62above but for motor pump set up to 15 HP motor pump set complete all as specified and directed. |
| 82 | S&F in replacement of fully automatic star delta starter in sheet-steel enclouser type MN with single phase protection suitable for motor rating 5.5 KW 3 phase 415 volt 50 Hz relay range 12-15 Amps complete all as specified and directed. |
| 83 | M&L for repair/servicing of LT indoor panel board of any size/type, cleaning with compressed air, checking all internal components viz wiring, controls replacement of old lugs, nut bolts, thimble for proper connection to main earth lead , glands to be provided /replaced as required at cable entires, fixing of front & back side broken door hinges after repair and servicing spray painting with powder coated paint with weather protection supperenamelled paint of existing colour in outer/inner side of panel aftercleaning and preparing surface complete all as specified and directed.(Note:-Any other Unsv spares if any required for replacement , same will be measured under relevent item of schedule) |
| 84 | M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mmby means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soilto a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), \"mild steel angle iron frame\" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown inelectrical \"plate No 3\" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed. |
| 85 | Refilling of fire extingusers with Carbon dioxide ( CO2) capacity 2 Kg complete all as specified and as directed. |
| 86 | Refilling of fire extingusers with Carbon dioxide ( CO2) capacity 4.5 complete all as specified and as directed. |
| 87 | Refilling of fire extingusers with Carbon dioxide ( CO2) capacity 6.8 Kg complete all as specified and as directed. |
| 88 | Refilling of fire extingusers with Carbon dioxide ( CO2) capacity3.2 complete all as specified and as directed. |
| 89 | Reffiling of fire extingusers with ABC(DCP) type10Kg capacity complete all as specified and as directed. |
| 90 | Reffiling of fire extingusers with ABC(DCP) type6 Kg capacity complete all as specified and as directed. |
| 91 | Reffiling of fire extingusers with ABC(DCP)type5Kg capacity complete all as specified and as directed. |
| 92 | Reffiling of fire extingusers with ABC(DCP) type4 Kg capacity complete all as specified and as directed. |
| 93 | Reffiling of fire extingusers with ABC type1 Kg capacity complete all as specified and as directed. |
| 94 | Supplying and fixing of fire branches(Nozzles) complete all as specified and as directed. |
| 95 | Supplying, fixing and testingincluding taking down in replacement of unserviceable hose reel drum with swinginghose reel 30 mtr comprising ofply rubber hose of size 20mm(3/4\"), 15m long tested with 25kg/cm²/350 psi bursting pressure with wall mounted mild steel pressel reel with 180º angle swinging with non-jamming contolling handle which shall stay at the ON/OFF position as set, wall bracket with \"U\" shaped reel carrier made of CI of post office red colour finish in and including gun metal noel and shut off ball valve, heavy duty confirming to IS: 884 and ISI markedcomplete all as specified and as directed. |
| 96 | Supply and fixing of RRL hose type - A 7.5 m complete all as specified and as directed. |
| 97 | Supply and fixing of Fire Extinguisher, CO2 Type Capacity 2 kg, ISI Marked IS:15683 complete all as specified and as directed. |
| 98 | S & F fire Extinguisher, CO2 Type Capacity 3 kg, ISI Marked IS:15683 complete all as specified and as directed. |
| 99 | Supply and fixing of Fire Extinguisher, CO2 Type Capacity 4.5 kg, ISI Marked IS: 15683 complete all as specified and as directed. |