| 1 | Dismantlingroofingincludingridges,hips,valleys andguttersetc.,andstacking thematerial within 50 metres lead of: 15.28.1 G.S. Sheet |
| 2 | Demolishing thatch roofing including mats, bamboo, jaffari etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 3 | Demolishingcementconcretemanually/by mechanicalmeansincludingdisposalofmaterial within 50 metres lead as per direction of Engineer in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (including equivalentdesign mix) |
| 4 | EARTHWORKINFOUNDATIONTRENCHES:Earthwork in excavation by mechanical means (HydraulicExcavator)/manualmeansin foundationtrenchesordrains(notexceeding1.5 minwidth or10sqmonplan)including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 5 | Fillingwithavailable excavated earthintrenches, plinthandsideoffoundationinbuildingworks with layers not exceeding 20cm in depth including consolidationofeachlayer byramming, wateringetc, all complete. |
| 6 | Providingandlayinghandpackedstonesolingin buildings works with clean hard selected stones, allcomplete. (Manual Means) |
| 7 | Stone masonry work in cement mortar 1:6 in foundation complete as drawing and TechnicalSpecification |
| 8 | ProvidingandLayinginpositioncementconcrete of specified grade including compacting curing etc all complete. 1:3:6 mix. (1 cement, 3 coarsesand, 6 stone aggregate of 40mm & down size) |
| 9 | Providing and Laying in position specified grade of reinforcedcementconcreteexcludingthecostof formwork,finishingandreinforcements.1:1.5:3 Mix (1cement,1.5 coarse sand 3 graded stone aggregate 20 mm and down nominal gauge). |
| 10 | Supplying, bending and placing in position tor steel reinforcementinallR.C.Cworks includingcostofbinding wires, all complete. |
| 11 | Providing, fixing & removing form work for castingR.C.C itemsas indicated below: with locally availabletimber).Foundation,footings,baseof column etc for mass concrete. |
| 12 | Providing, fixing & removing form work for castingR.C.C itemsas indicated below: with locally availabletimber).Beam,lintels,girders, brersumers and cantilevers. |
| 13 | Providing, fixing & removing form work for castingR.C.C itemsas indicated below: with locally availabletimber).Floorslab,roofslab,landing, balcony and access platform. |
| 14 | Providing, fixing & removing form work for castingR.C.C itemsas indicated below: with locally available timber). Square columns |
| 15 | Providingandlayingfirstclassbrickworkinhalf brick thick in superstructure of standard size bricks with1:4cementmortar(1cementand4course sand)includingcarriageofbricksuptoworksite,curing etc all complete. |
| 16 | ProvidingandLayingfirstclassbrickworkinone brick thick in superstructure of standard size bricks with1:5cementmortar(1cementand5clean coarsesand)asperthedirectionofEngineerin Charge including curing etc all complete. |
| 17 | Providing and Laying 12mmthickcement plaster ofspecifiedmixinsinglecoatincludingfinishing even and smooth and curing complete. 1:4 mix. |
| 18 | Providing and Laying 15mmthickcement plaster ofspecifiedmixinsinglecoatincludingfinishing even and smooth and curing complete. 1:4 mix. |
| 19 | 15mmcementplaster onroughside ofsingleor half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 20 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 21 | Providing and laying Vitrified tilles in floor in differentsizes(thicknesstobespecifiedbythe manufacturer) with waterabsorption less than 0.08%andconformingtoIS:15622,ofapproved brand&manufacturer,inallcoloursandshade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4coarsesand)jointingwithgreycementslurry @3.3kg/sqmincludinggroutingthejointswith white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Layingoftileswillbedonewiththenotch trowel,plier,wedge,clipsofrequiredthickness, levelingsystemandrubbermalletforplacing the tiles gentlyand easily. Double chargevitrifiedtile polished finish of size 600 x 600 mm. |
| 22 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cementmixedwithpigmentofmatchingshade complete. |
| 23 | Providing, fitting and fixing of dressed local timber (tooni,katusequivalent)inalltypesofframes complete. With locally available timber |
| 24 | Providingandfixing35mmthickfactorymade laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, allcompleteasper directionsof Engineer- in- charge and panelling with panels of : (Note:- Butt hingesandnecessaryscrewsshallbepaid separately)12mm thick pre-laminatedparticle board (decorative lamination on both sides) grade 1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conformingtoIS:3087,bondedwithBWPtype synthetic resin adhesive as per IS : 848 and prelaminatedconformingtoIS:12823,Grade1, Type - II marked : |
| 25 | ProvidingandfixingM.S.pressedbrightfinishedbutthingeswithnecessaryscrewsetc.complete. 150x31x4mm |
| 26 | Providing, fitting and fixing sliding door bolts with nutsandscrewsetc.complete.Size300x16mmM.S (Bright Finish) |
| 27 | Providing and fixing tower bolts 300x10mm (Barrel type) with necessary screws etc complete. M.S |
| 28 | Providing,fittingandfixinghandles125mmsize with necessary screws etc complete. M.S. |
| 29 | Providing, fitting andfixing steel windowsand ventilatorsofstandardrolledsteelsectionjoints miteredandweldedwithironlugsembeddedin cementconcreten1:3:6includingprovidingfitting and fixing 3 mm thick glass pens with glazing clips andspecialmetalputtycompletewithMSgrills @150 mm c/c as per the direction of Engineer - in- Charge all complete: |
| 30 | PAINTINGANDPOLISHINGWORKS,PRIMERS,Providingandapplyingprimingcoatwithready mixedpinkontimberworkincludingpreparation ofthesurfacebythoroughlycleaningandsand papering etc complete. |
| 31 | PAINTINGANDPOLISHINGWORKS,PRIMERS,Providingandapplyingprimingcoatwithready mixedRedoxide,Zincchromateprimeron steel/galvanized Iron steel works including preparation of the surface complete. |
| 32 | PAINTINGANDPOLISHINGWORKS,ENAMELPAINTS,Providingandpaintingwithreadymixed paintofapprovedqualityandshadewithtwoor morecoatstogiveanevenandsmoothshade includingclearingthesurfacecompleteonnew surface.. |
| 33 | DistemperingwithdrydistemperonNewsurface twoormorecoatsofrequiredshadetogivean even and uniform shade including priming coat of whiting to give an even shade afterthorough cleaning of dirt, dust, loose pieces of scabs, grease etc including surface preparation by sand papering etc complete. New surface |
| 34 | Providing and washing with three or more coats of snowcem, durocem, cemcote etc. of approved quality and manufacture onexteriorwalls togiveanevenshade including preparation of surface on New surface complete. |
| 35 | Makingplinthprotection50mmthickofcement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derivedfromnaturalsources:6gradedstone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast40mmnominalsize,wellrammedand consolidated and grouted with fine sand, including necessaryexcavation,levelling&dressing& finishing the top smooth. |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes,havingthermalstabilityforhot& cold water supply, including all CPVC plain & brass threaded fittings,includingfixingthepipewith clampsat 1.00mspacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtestingofjointscompleteasperdirectionof EngineerinCharge.Internalwork-Exposedon wall 25 mm nominal outer dia Pipes. |
| 37 | P/F stainless steel kitchen sink with CI brackets, CP brass chain with rubber plug 40mm CP brass waste, CPbrass, tapetccompletei/cthefittings, cuttings and making good the wall wherever required. 610 x 450 x 200 mm. |
| 38 | ProvidingandLaying flooringwithgranite marble stoneslabs 20mmthick granite stone slabs flooringofsizenotlessthan1.0sqmof20mm thick laid over 20mm (average) 1:4 cm thick b are laid cement concrete and joint treated with white cement, mixed with matching pigment, curing includingrubbingtogiveagranitefinish,asper the direction of Engineer in Charge and carriage of material up to work site, all complete. |
| 39 | Providing and placing on terrace high density polyethylene water storage tank with manhole lid and suitable locking arrangement including making holes for inlet, outlet and ball cock including testing etc. all complete: (Sintex or equivalent) |
| 40 | Providing,fittingandfixing.whitevitreouswhite china wash flat back basin with CI brackets, painted, 15mm CP brass pillar taps, CP brass chain with rubber plug, 32mm CP brass waste pipe, lead orPVCconnection32mmdiaCPbrasscapand unions, complete including cutting andmaking goodthe walls wherever required.HINDWARE 55cm x 40 cm |
| 41 | Providing,fittingandfixingsoil,wasteandvent pipes including testing etc complete. 100 mm dia. PRINCE / SUPREME soil Pipe |
| 42 | Providing,fittingandfixingsoil,wasteandvent pipesincludingtestingetccomplete.75mmdia.PRINCE / SUPREME soil Pipe |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - Group B (Electrical works) |
| 44 | Wiring for 16 A plug point with 2X2.5 sqmm FRLSH PVC insulated copper conductor single core cable in best quqlity in best quality reccessed alkathine pipe and earthing the point with 1X2.5 sqmm HRFRLS PVC insulated Copper Conductor single core cable as required. (Electrical works) |
| 45 | Wiring for sub main light/fan/call bell/& 6A plug pointwith 2X2.5 sqmm FRLSH PVC insulated copper conductor single core cable in best quqlity in best quality reccessed alkathine pipe and earthing the point with 1X2.5 sqmm HRFRLS PVC insulated Copper Conductor single core cable as required. (Electrical works) |
| 46 | (a) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - 5/6 A switch (Electrical works) |
| 47 | (b) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. - 3 pin 5/6 A socket outlet (Electrical works) |
| 48 | Supply and fixing two module stepped type electronic fan regulator on the existing modular plate swich box including connections but excluding modular plate etc.as required. (Electrical works) |
| 49 | Supplying and fixing Modular Blanking Plate on the existing blanking Plate & Switch Boxes exluding modular plate as required. (Electrical works) |
| 50 | Supplying and fixing 1 no. 16 amps socket & 16 amps switch, white plate (4 module) & metal flix box (4 module) including connection etc. as required. (Electrical works) |
| 51 | Supply and fixing angle/ batten holder with 9 watt LED Lamp including connection etc as required. (Electrical works) |
| 52 | Supply and fixing LED Tube light 22 watt 4 fittingincluding connection etc as required. (Electrical works) |
| 53 | Supply, Installation, testing and commissioning of ceiling fan 1200 mm with complete accesaries including connection as required. (Electrical works) |
| 54 | Supplying and inatallation of MCB Distribution Board Double/Single door (confirming to CPWD/NBC/Relevent IS&BIS Code) - 12 Way SPN (Single Door). (Electrical works) |
| 55 | Supplying, inatallation, Testing & commissioning of Miniuature Circuit Breaker(confirming to CPWD/NBC/Relevent IS&BIS Code) - Single Pole 6-32 amp (Electrical works) |
| 56 | Earthing with GI 600mmX600mmX6mm thk including accesaries and providing masonary enclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc with charcoal/coke and salt as required. (Electrical works) |