| 1 | ABC |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modularplate, suitable GI. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as reqd. Group-C |
| 3 | Rewiring for light point/fan point/exahust fan point/call bell point with1.5SQmm FRLS PVC insulated copper conducter S/c cable and1.5 sq.mm.FRLS PVC insulated copper conductor S/C cable as earth wirein existing surface/recessed steel /PVCconduit,i/c dismentling as required. |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x2.5 sq mm |
| 5 | 6X2.5 sq mm |
| 6 | 3X 4 sq mm |
| 7 | 6x4 sqmm |
| 8 | 3 X 6 SQ MM |
| 9 | 5 X 6 SQ MM |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 11 | 25 mm |
| 12 | Supplying and fixing following modular type switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp switch |
| 13 | 15/16 amps switch . |
| 14 | 3 pin 5/6 amp socket out let |
| 15 | 6 pin15/16 amp socket outlet |
| 16 | Telephone socket outlet |
| 17 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 18 | Supplying and fixing following size / modular, GI box alongwith modular base & cover plate for modular switches in recess etc as reqd. 1 or 2 Module (75X75 mm) |
| 19 | 4 Module (125X75mm) |
| 20 | 6 module (200 mmx75mm) |
| 21 | 8 module (125 mmx125mm) |
| 22 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 23 | Supplying and fixing call bell/ buzzer suitable for single phase 230 V, complete as required |
| 24 | Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored. |
| 25 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 26 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 27 | Supplying and fixing suitable size GI Box with modular plate and cover in front of on surface or in recess including providing and fixing 25 A modular sheet outlet and 25 A modular SPMCB \"C\" curve including connection painting etc as reqd |
| 28 | Supplying and fixing following ways surface/recess mounting, vertical type, 415 V, TPN MCB DBof sheet steel, dust protected , dully powder painted, inclusive of 200 A tinned copper bus bar, common neutral link,earth bar, din bar fpr mounting MCBs (But without MCB and incomer) as required. (note: vertical type MCB TPDB is normally used where 3 phase outlets are required.) . 4 way (4+12) , Double door |
| 29 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 30 | S&F Cable End Box (Loose wire box) suitable for following single pole and neural , sheet steel, MCB distribution board 240 Volts, on surface/recess, complete with testing and commissioning etc. as reqd. (a) For 14 way, Double door SPN MCBDB |
| 31 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 32 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 33 | S/I/T/C of LED panel light 2X2 ft.(Systeml lumen efficacy>135 lm/watt) SITC of panel light 2x2 ft. of following body material and construction as pr IS:10322 with driver as per the requirement with driver effciency >85%, operatin voltage AC140-270 volt, frequency 50HZ, operating temp range-15 deg to 40 deg centigrate, internal surge protection of 2.5 KV with short and open circuit protection THD <10%, PF >-95luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/surface with connections as reqd.(a)Tot, IP 20, CRI>80, UGR (Unified glare rating) <19, flicker free, (flicker should be below 5%), life time (LED driver & electrical circitry) of minimum 50000 Burning hours with , 70% of initial Lumen maintained till life ends, CCT 3000*K/4000*K/5700*K/6000*K/6500*K (As per ANSI bin), SDCM (Standard deviation color Matching)< Maximum power consumption should not more than the specified ratin and fixture shall be of relevant BIS standard and trade mark certicicate (T>C.) Manufactures Word mark/Name Engraved/ Embossing Screen printing on housing. complete in all respect i/c connections with 1.5 sqmm FRLS PVC insulated copper condutor single core cable and earthing etc. as required with Minimu 5 years OEM warranty. System lumen efficacy >135 Lm/Watt output LM 79 & LM 80 test reprt from NABL lab for all testing required for LED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in -charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90*C ) CRCA sheet body (Thickness ≥1.20 mm) 36 W |
| 34 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitialLumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completeinallrespecti/c connectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsink ofaluminumhousing such that LED junction temperature shall not rise above 90°C).Powdercoated die cast/ Extrudedaluminium Body (Thickness ≥ 1.20 mm)18 - 22 watt |
| 35 | WINDOW AC UNITS Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 0C (out door ambient temperature). Non Inverter Type 1.5 TR with fixed speed 5 Star BEE rating |
| 36 | HI - WALL SPLIT SYSTEMS Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating |
| 37 | Supply, Installation, Testing andCommissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC )Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2nos. canopies, shackle kit, saftey rope, copper winding, Power Factor not less than 0.9, ServiceValue (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remoteor electronic regulator unit forspeed control and all remaining accessories including safety pin,nut bolts, washers, temperaturerise=75 degree C (max.), insulationresistance more than 2 mega ohm,suitable for 230 V, 50 Hz, singlephase AC Supply, earthing etc.complete as required. |
| 38 | Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)\"s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging,output over current, short circuit, battery deep discharge , 10 KV surge. Displayfor watt/VA,Amp and Voltage power parametersetc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2,it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be withIGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductorcable of suitable size and connectors and all required accoseries are inclusive in the cost.The UPSshould have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc .3KVA |
| 39 | Supplying and fixing of full stainless steel body self contained drinking water cooler with cooling capacity 150 ltr/ hr, storage capacity 150 ltr and suitable for 230V supply as required. |
| 40 | Supplying AND Installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as required. |
| 41 | S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V |
| 42 | S/I/T/C of Drain Pipe |
| 43 | S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner |
| 44 | S/I/T/C of copper pipe for split AC |
| 45 | S/I/T/C of stand for split AC |
| 46 | SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color |
| 47 | S/I/T/C of 2MP fixed lensDOME IP Camera with following specifications:-Image Sensor: 1/32MP CMOS or better**Minimum Illumination: 0.08 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate:1-25 fps or better **Lens: 2.8 FixedVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (1920x1080) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 25mOperating Temperature: -20 to 55 deg CentWeatherproof Standard:IP66 or better ** |
| 48 | SITC of 2MP fixed lens Bullet IP Camera with following specifications:-Image Sensor: 1/3 2MP CMOS or better**Minimum Illumination: 0.08 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 1-25/30 fps or better **Lens: 2.8mm fixedVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (1920x1080) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -30 to 50 deg CentWeatherproof Standard:IP66 or better ** |
| 49 | S/I/T/C of 8 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or better**Network Throughput :200Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 2 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg Cent |
| 50 | SITC of 6 TB surveillance HDD |
| 51 | SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch |
| 52 | SITC of IP65 box(without PoE switches)of dimention 310mmX160mmX140 mm onpole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set |
| 53 | S/I/T/C of full HD LED Monitor,32inchescomplying to with following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min. Contrasts :1200:1 or betterPower supply : 230v + / - 10%, 50 Hzat sitewith connections andalong with all accessories completeas required. |
| 54 | SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8 U |
| 55 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 56 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable |
| 57 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable |
| 58 | Supply of 12\" ( 300mm sweep) exhaust fan heavy duty complete withshutter, bladesetc as required |
| 59 | supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged) |
| 60 | Supply of 9 Watt LED retrofit lamp suitable for B22 holder |
| 61 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd. |
| 62 | Supplying and fixing 63A, 4 Pole rating, 415V, and 10KA “C Curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections, testing and commissioning etc. as required. |
| 63 | SITC of single phase monoblock pump set complete with all accessories workable on 240/415 volt, 50 Hz ac supply a) 1 HP (0.75 kw) single phase pump set, head from 12 -30 mtr. suction and delivery 25x25 |
| 64 | Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etcas reqd. 32 mm (nominal size) |
| 65 | S & F following size of G.I. Socket. as reqd. 32 mm |
| 66 | S & F MS clamp made up of iron flat of size 50X6 mm with 4 nut bolt for holding the GI pipe pipe as reqd. 32 mm |
| 67 | Supplying and fixing following sizes of insulated steel flexible safety rope for holding submersible pump set i/c clips etc complete as reqd.(a) 6 mm dia |
| 68 | Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. a. Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head |
| 69 | P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3 X 2.5 sq. mm |
| 70 | Development of tube well with suitable capacity of air compressor i/c lowering of the necessaryinduction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when gravel stop sinking discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. |
| 71 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phasesubmersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc includingconnections etc as reqd. a. 1.5 HP (Single Phase) |