| 1 | BUILDING STRUCTURE |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to adistance of 50 m. beyond the building area and stacking andspreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By |
| 3 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to20 cm including watering and compaction etc. complete. |
| 4 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping,compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fineaggregate (Crushed sand VSI Grade) |
| 5 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifosper square meter of surface area covering 10 years guarantee onbond paper. |
| 6 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fullyautomatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 7 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be providedand curing etc. complete. (Excluding reinforcement and structuralsteel).with fully automatic micro processor based PLC with SCADAenabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI |
| 8 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks,laying/pumping, compacting and roughening the surface if specialfinish is to be provided and curing complete. (Excluding reinforcementand structural steel). with fully automatic micro processor based PLCwith SCADA enabled reversible Drum Type mixer/ concrete Batchmix plant (Pan mixer) etc. complete. With fine aggregate (Crushed |
| 9 | Providing and fixing in position TMT - FE - 500 bar Reinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 10 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffoldingetc. |
| 11 | Providing internal cement plaster 12mm thick in single coat incement mortar 1:4 without neeru finish to concrete or brick surfaces,in all positions including scaffolding and curing etc. complete. |
| 12 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days andkeeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days |
| 13 | Providing and applying white-wash in two coats on old / new plasteredor masonry surfaces and asbestos cement sheets including scaffoldingand preparing the surface by brushing and brooming down etc. complete |
| 14 | Providing and applying colour-wash of approved colour and shade inone coat to new surface including scaffolding, brushing and broomingdown (excluding base coats of white wash) etc. complete. |
| 15 | Providing and laying in situ cement concrete M20 with tremix treatmentfor 100mm thickness for flooring with groove cutting of 4mm wide and 20mmdeep with necessary refilling with bitumen etc. complete. |
| 16 | Providing structural steel work in trusses, other similar trussed purlinsand members with all bracing, gusset plates etc. as per detaileddesigns and drawings or as directed including cutting, fabricating,hoisting, erecting fixing in position, Making riveted/ bolted/ weldedconnection and one coat of anticorrosive paint and over it 2 coats of oilpainting approved quality and shade etc. complete. |
| 17 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mmmild steel flat stringers and steps of 18 mm dia. mild steel bar forwater tank including fixing it in (1:2:4) M-15 cement concreteblock 60cm x 30cm x 30cm and painting the ladder complete |
| 18 | Providing and fixing corrugated galvanised iron sheets of 0.63 mmthick (24 B.W.G.) for roofing without wind tiles including fasteningwith galvanised iron screws and bolts, lead and bitumen washers as perdrawing etc. complete. (Weight of 5.5 kg / sqm.) |
| 19 | Providing and fixing rolling shutter fabricated from steel laths ofminimum thickness 0.9 mm with lock plate of 3.15 mm thicknessreinforced with 35 x 35 x 5 mm angle section fitted with sliding boltsand handles for both sides, deep M.S. channel section of depth andthickness not less than 65 mm and 3.15 mm respectively with hold fastarrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum sizeand shape with square bar, suspension shaft of minimum 32 mmdiameter, hood cover of M.S. sheet not less than 0.9 mm thickness andof any size at top and safety devices including mechanical gearoperation arrangement consisting of worm gear wheels and worms ofhigh grade cast iron or mild steel and one coat of red lead primer etc. |
| 20 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 21 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 22 | Providing and fixing steel window of various sizes as per detaileddrawing without hot dip zinc coating, without ventilators, includingfabricating / glazing with plain / obscured glass panels of approvedtype and quality, iron oxidised fixtures and fastenings, finishing with oilpainting two coats complete (with guard bars 12 mm square at 10 cm |
| 23 | ELECTRIFICATION |
| 24 | Supplying and erecting mains with 3 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or any other places as perspecification No: WG-MA/BW |
| 25 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 30having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%,p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with |
| 26 | Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as perspecification No: WG-PW/SW |
| 27 | Supplying and erecting steel tubular swaged pole 139.7 x114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH- PL/STP |
| 28 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 29 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testingand recording the results as per specification no. EA-EP |
| 30 | Supplying, erecting & marking DP-MCB 6A to 32A, C- series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 31 | Supplying, erecting & marking DP-MCB 6 A to 32 A, B- series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR / MCB |
| 32 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red leadpaint and 2 coats of enamel paint. |
| 33 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners,supports, nut bolts etc. complete with compliance to IS |
| 34 | Wiring for plug on board with Switch socketsurface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG |
| 35 | Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position asper specification no. FG-FN/CF |
| 36 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provideddistribution board. |
| 37 | ROYALTY CHARGES |
| 38 | Royalty for Sand |
| 39 | Royalty for murum and Other material |
| 40 | QUALITY CONTROL & LAB TESTING |
| 41 | M20 CONCRETE: Mix Design with all tests on basic materials |
| 42 | M20 CONCRETE: Concrete cube compressive strength |
| 43 | M10 CONCRETE: Concrete cube Test |
| 44 | M25 CONCRETE: Mix Design with all tests on basic materials |
| 45 | BRICKS : Water Absorption (Set of 5 Bricks), Compressive strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks) |
| 46 | TMT STEEL : Yield Stress, Ultimate Tensile Stress, Elongation, Weight per running meter. |
| 47 | Sand :- i) Fineness Modulus, II) Silt content |
| 48 | Murum :- ii) Atterberg Limit |
| 49 | iii) Density of compacted layer |
| 50 | iv) Proctor Test |
| 51 | Cement Test i) Comprecive strengh ii) Intital and final setting time iii)Spcific Gravity iv) Spicific Gravity v) soundness vi) Finess |
| 52 | Metal Test i) AIV ii) Gradintion iii) water Absorbation |
| 53 | Management Strategies and implementation plan (MSIP) to manage the Environmental Social Health and safety (ESHS) risks and ESHS Code of Conduct Please Enable Macros to View BoQ information |