| 1 | Dismantling AC/ CGI/ translucent ( corrugated, semicorrugated,etc),as in roof covering complete. |
| 2 | Dismantling of timber scantling 40 Sqcm and over in section in any position complete. |
| 3 | M&LSecond class hard-wood in timber framedscantling Clean swan fixed in repair,to replace old and decayed timber (including piecing scarfing,etc,of old and new timber if required)and removing defective portions to store etc complete all as spd & directed. |
| 4 | M&L 6 mmthick asbestos cement, corrugated or semi corrugated sheets in roof, walls etc fixed with L-T type or J-type or cranked hook bolts etc complete all as specified and directed by EIC . |
| 5 | Description all as per ser item No 4 above, but exept sheet |
| 6 | S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, Chhaja, etc fixed with self tapping screws as specified. |
| 7 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 8 | Dismantling of wall/ceiling boards(fibre, pulp, insulation, etc) of any type including cover fillets. |
| 9 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer\"scomplete all as specified. |
| 10 | M&L 4mm thicknon asbestos fibre designer cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws. |
| 11 | Taking down cement plaster on wallof any description incl racking out joints hacking for key and scrubbing down with water complete. |
| 12 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete. |
| 13 | M & L rendering 15 mm thick in cement mortar 1:4 on Wall/chajjas/lintel etc and finished even and fair without using extra cement in patches. |
| 14 | M & L rendering 15 mm thick in CM 1:6 inon surface of walls and finished even and fair (without using extra cement) in patches. |
| 15 | M & L preparation of new plastered surfaces nd finishing the surfaceof walls with wall putty and applying two coats of oil bound distemper overa coat of cement primer of, any colour complete all as specified & directed |
| 16 | M & L preparation of new plastered surfaces of walls and applying two coats of exterior emulsion Paint(Apex)overone coat of exterior primer, complete all as specified & directed |
| 17 | M&L preparating surfaces of wood and wood based materials new or old ,of any description and girth,not otherwise described and treated with two coat of creosote oil complete all as spd and directed |
| 18 | M & L for complete removal of existing Treatment over and applying two coat of distemper oil emulsion over 3mm thick wall care putty complete all as specified and directed. |
| 19 | M & L for complete removal of existing treatment over Two coat of weather proof acrylic emulsion (anti dust) paint exterior grade(100% acrylic) over a coat of primer externat surface of walls of any description over 10cm width or girth etc on column/pilla,rcc chajjaa and facia etc complete as specified and directed. |
| 20 | S&F in repair decorative types Eaves board made with Upvc having thickness not less than 6mm, with 200mm width fixed to existing timber/metal frame(Rafter/purline/wall plate) using Rust free screw or galvanised nails complete all as specified and directed by engineer- in -charge. |
| 21 | Dismantling fencing wire mash any type complete all as specified and directed. |
| 22 | Dismantling posts/pillers or struts (Wood, Steel, or RCC) any section, including taking out embedded portion post embeded in concrete and making good disturbed ground complete all as specified and directed. |
| 23 | Excavating in post holes (or similar holes) each n exc0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc50m and making good surface complete all as specified and directed. |
| 24 | M&L PCC 1:3:6 type C2 using 40 mm graded stone aggr as in foundation filling and mass concrete complete all as specified and directed. |
| 25 | S&FMS angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conformingcomplete all as specified and directed. |
| 26 | Supply only Mild steel in flat, roundbars, in available lengths quality con-forming to Fe- 290 (Gde E- 165) complete all as specified and directed. |
| 27 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm long but n exc 10 cm & dia of neck 11 to 15mm complete all as specified and directed. |
| 28 | Supply only3.15mm dia GI wire 108x108 mm mesh (chain link fencing) made up to mattresses or cages lapped wired and laid in position including closing and tied withposts properly complete all as specified and directed. |
| 29 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining 10 mm dia steel bar, bolts, etc. including provision of binding wire complete all as specified and directed. |
| 30 | S&Fin repairs Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type or standard rails straining balte, including securing or tying at crassing with provision of Galvanised mils steel wire staple pine etc as directed (each line wire to be mesured) complete all as specified and directed. |
| 31 | S&F Concertina coil reinforced punch (crome razor of blade wire ) with bardbed tap 0.5 mm thick galvanized steel sheet and core wire of dai 2.5 mm high tensile steel wire of concertina coil fencing with punched tape 450 mm dia having 45 nos round per 6m length includind taking out oldwire coplete. |
| 32 | M&Lfor preparation of newsteel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxideprimer and applyinng 2 coats of synthetic enamel paint of approved shade complete all as specified and directed. |
| 33 | M&Lfor preparation of oldsteel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxideprimer and applyinng one coats of synthetic enamel paint of approved shade complete all as specified and directed. |
| 34 | M&L brick work with sub class \"B\" brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 |
| 35 | Description all as per ser item No 34 above, but except bricks |
| 36 | M&L three coat of white wash on newly preparedsurfaces on wall , etccomplete. |
| 37 | M&L two coat of white wash on old surfaces on wall , etccomplete. |
| 38 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 39 | Demolition of reinforced cement concreteof any description in any position not otherwise described complete. |
| 40 | M&L Cement concrete in foundation filling and mass concarete (1:4:8) type D-2( 40 mm graded aggregate) ,complete all as specifed and directed. |
| 41 | M&L Cement concrete inin eight,copings, kneelers, apex stones, bed plates, kerbs (1:2:4) type B-1( 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismi cand other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight,copings, kneelers, apex stones, bed plates, kerbs complete all as specified and directed. |
| 42 | M&L Reinforced cement concrete (design mix)in M-25(20mm graded aggregates) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete,complete all as specifed and directed. |
| 43 | M&L Reinforced cement concrete (design mix)in M-25(20mm graded aggregates) Columns, pillars, piers,posts and struts,complete all as specifed and directed. |
| 44 | M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specifed and directed. |
| 45 | Description all as per ser item No 44 above, but 8mm dia as in stirrups and binders ,complete all as specifed and directed. |
| 46 | S&F 1.25mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 47 | Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |