| 1 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 2 | Demolition of cement concrete in ground floors and pavings n exc 15cm below or above ground floor and removing rubbish from site complete all as specified and directed. |
| 3 | Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) n exc 1.5 sqmeach etc complete all as specified and directed. |
| 4 | Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but n exc n.exc 4Sqm and making the surface good with cement plastering on jambs and cills of openings in CM 1:6 each complete all as specified and directed. |
| 5 | M &L for Brickwork with subclass \"B\"bricks, straright or corved on plan exc 6m mean radius built in Cement mortar 1:6including demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and directed. |
| 6 | Cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, in cement mortor 1:3 cutting not exceeding 10cm girth complete all as specified and directed. |
| 7 | Material and labour for joint free non skid ceramic colouredtiles 7 to 8mm thick area of each tile exc 0.18 Sqm but not exc 0.38 sqm in floors etc, set and jointedin neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM (1:6) etc complete, including dismantling of existing floor tiling with cement mortar bedding (but not backing) and removing rubbish from site complete all as specified and directed. |
| 8 | All as per item no. 7above butin dado / skirting etc. over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed. |
| 9 | Material and labour for coloured anti skid ceremic tiles 7 to 8 mm thickarea of each tiles exc. 0.06 sqm and n. exc. 0.11 sqmas in floor etc, set and jointedin neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM (1:6) etc complete, including dismantling of existing floor tiling with cement mortar bedding (but not backing) and removing rubbish from site complete all as specified and directed. |
| 10 | Material and labour for digital glazed ceramic joint free(rectified) coloured tiles on vetical surfaces size 600x300x7mm thick etc, set and jointedin neat cement slurry and pointed in white or coloured cement to match, fixed over & including 15mm thick rendering in CM 1:4 etc complete, including dismantling of existing floor/wall tiling with cement mortar rendering (but not backing) and removing rubbish from site complete all as specified and directed. |
| 11 | M&L 25 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in sub base of floor to receive tiles or kota stone complete all as specified and directed. |
| 12 | M & L for rendering 20 mm thickcement plaster in cement mortar 1:6on stone masonary / other than fair finished surfaces of brick wallfinishing the surfaces even and smoothetc complete all as specified and directed. |
| 13 | M&L rendering 15mm thick on stone masonry surfaces or surface other than fair face of brickwork in CM (1:4) including water proofing compound @ 2% by wt of cement complete all as specified and directed. |
| 14 | M&L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed. |
| 15 | M & L for providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in coping , apex stone , bed plate , kerbs including weathering , slightly rounded or chamferred angles and throating and incl. necessary form work etc complete all as specified and directed. |
| 16 | M&L for preparing the new plastered surfaces and applying three coats of white wash on walls all as specified and direcrted. |
| 17 | M&L for applying three coats of white wash on new ceiling surface including preparation of surface complete all as specified and directed. |
| 18 | S&F Solid PVC door frame of size 50mmX47mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet (edges will be painted to match with prelam sheet) reinforced with MS square tube, suppling & fixing in opening as per specification complete all as specified and directed. |
| 19 | S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 4mm thick moulded PVC sheet on the front face & 4mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specified. |
| 20 | S&F Aluminium handles 150mm size, cast type, anodised complete all as specified and directed. |
| 21 | S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed. |
| 22 | S&F 100mmButt hinges, extruded aluminium aloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed. |
| 23 | S&F in repairs 110mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed fixed to wall or in trenches including ms clamps complete all as specified. |
| 24 | S&F PVC (SWR) bends 110 mm dia all as specified and directed. |
| 25 | S&F PVC (SWR) 110 mm diajunction, single(single \"T\")equal or unequal complete all as specified and directedcomplete all as specified and directed. |
| 26 | S&F PVC(SWR) vent cowl of 110mm dia complete all as specified and directed. |
| 27 | S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with solvent joints laid in trenches or fixed to walls complete all as specified and directed. |
| 28 | S&FPVC (SWR) bends 75mm dia complete all as specified and directed. |
| 29 | S & F in repairs for 75 mm dia PVC ( SWR) floor trap with grating including jointing with solvant etc complete all as specified and directed. |
| 30 | S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15 mm diaGI tubing and connections complete all as specified and directed |
| 31 | S&FGI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 20mm diaGI tubing and connections complete all as specified and directed |
| 32 | S&F in repairPVC float valve assembly including assessories with float valve 20mm dia complete all as specified and directed. |
| 33 | S&F in repair C P bib taps, cast copper alloyfancy conceledtype with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm boreand fixed complete all as specified and directed. |
| 34 | Supply and fixed in repair angular stopvalve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed. |
| 35 | S&F in repairGun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe. |
| 36 | S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges as fixed in repair etc |
| 37 | S&F in repair vitreous china WHB white flat back size 550x400mm including S&F angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed. |
| 38 | S&F in repairvitreous china squatting pan \"Orrisa pattern\" size 580x440mmwhitewith integral foot rests any pattern including provn of cement concrete bedding and making connection with & including P or S Trap, etccomplete all as specified and directed. |
| 39 | S&F in repair PVC low level flushing cisternof 10 Ltr capacity including flushing pipe bend PVC bend and PVC connection 450mm long high pressureetc. complete all as specified and directed. |
| 40 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 1000 Ltrs Capacity incl. Dismantling water tanks complete all as specified and directed. |
| 41 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 500 Ltrs Capacity incl Dismantling water tanks complete. |
| 42 | Disconnecting PVC / AC / RCCexisting water tankof exc. 250 and not exc. 500 lit capacity , setting a side for repair , cleaning and removing all scale and dirts from tanks and from mouths of circulating pipesand hoisting if required reconnecting and refixing in position etcincluding writing of date of cleaning with synthetic enamel paint complete all as specified and directed |
| 43 | S&F in repairBevelled edge looking mirror of size 600x450 selected quality glass mounted6mm thick AC building board or commercial plywood andfixed to wooden plug with chromium plated screws and cup washer all as specified & directed. |
| 44 | M & L forPCC ( 1: 2: 4) type B-0 using (12.5mm graded stone aggregate) etcon roof top as a leveling course / paddingto maintainthe slope,finished the surfaces even and smooth without using extra cementetc. |
| 45 | Taking downof oldroof treatment of any description including mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr and n exc 500 mtr from the roof of height 3 to 9 mheight etc . |
| 46 | M&L for provn of water proffing roof treatment toRCC roof with approved modified membrane of weighing not less than 3kg/sqmcomprising with following items and all as specified as under:-(i) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting.For cast iron drain and outlets a groove shall be cut as specified and directed.(ii) Oil based Bitumenprimer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated.(iii) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm(iv) Laying of water proofing teratment of weight not less than 3 Kg / sqmAPP modified polymeric water proofing membrane composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc.(v) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqmover the membrane (vi) A fillet of PCC (1:2:4) of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of dirction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded and including M&L for cutting of grooves at wall all around 65mm deep 10mm wide for APP membrane to be laid in gap as required on site as directed by Engineer In Charge. |
| 47 | M&L for provn of water proofing roof treatment toRCC roof with approved modified membrane of weighing not less than 3kg/sqmcomprising with following items and all as specified:-(i) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting.For cast iron drain outlets a groove shall be cut as specified and directed.(ii) Oil based Bitumenprimer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated.(iii) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm(iv) Laying of water proofing teratment of weight not less than 3 Kg / sqmAPP modified polymeric water proofing membrane composed of 90 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc.(v) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqmover the membrane. (vi) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directedat site . |
| 48 | M&L for treatment of roof with reinforced elastomeric liquid waterproofing membrane of 400-micron thickness in four layer(100micron each layer) having SRI of 130, tested as per ASTM E 1980 (with Solar Reflectance and Thermal emittance tested as per ASTM C 1549 and ASTM C 1371 , respectively). The coating should have water absorption less than 1% as per IS: 101 (P-7/Sec-1) 1989, with the ability to resist heat upto 120 00 as per IS: 101 (P-7/Sec-3) 1990 having VOC less than f g/ltr as per ASTM D 3960 and should have excellent resistance to transmission of ponded water up to 2.5 bars of pressure for 7days. It should also be resistant to Ammonia solution, Sodium nitrate, Sodium hydroxide, along WIth water and soap solution as per IS: 101 (P-7/Sec-2)1990. The waterproofing membrane will be laminated with 25 - 40-micron thick transparent Nano modified composite crosslinking polymeric coating with a minimum of 40% solid content as per IS: 101 (P -8/Sec6)1993 and also should pass Impact test as per IS: 101 (P-5/Sec-3) 1988 along with having dust and water repellent & anti-graffiti property passing Scratch hardness test of 500g as per IS: 101 (P-5/Sec-2) 1988. It should also pass Cross Cut Adhesion test as per IS: 101 (P-5/Sec-2) 1988. The Polymeric coating should have a self-cleaning and easy-to-clean property with excellent weather stability and DPR (Dirt pickup ratio). Surface preparation includes cleaning the surface with wire brush and washing cleaning to remove all dust, fungus, etc.The work will be done under the supervision of the Engineer-in-charge.The coating thickness and the methodology of application shall strictly be carried out by the authorised vender/ manufacturers with all specifications and as approved by the Engineer-incharge. The manufacturer shall give a warranty for the peformance& durability for 7years. |
| 49 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner incl dismantling of existing tiles with screed bed, colour and pattern of tiles as approved by engr-in-Charge. (Note: There should be use of min. 3 mm thick spacer to fix tiles and making 3 mm wide joints between tiles) |
| 50 | Treatement for sunken portion is as follows :-(i) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed.(ii) M&L for providing 12 mm dia holes of 40mm deep @200mm c/c at junction of beams and columns as co-ordinal points for inserting/pouring cement slurry by pressure grouting for sunken floors of toilet , includind sealing the holes with CM 1:3, all as specified and as directed by EIC.(iii) M&L for water proofing plaster for sunken portionin CM 1:3, 20 mm thick in two coats with water proofing compound at the rate of 2% by weight of cement and finishing the surface even and smooth without using extra cement.(WPC will be measured and paid seperately).(iv) M&L for applyin evenlytwo coats of industrial bitumen 85/25 at the rate of 1.20 Kg/Sqm in each coat over vertical surfaces and floors of sunken floors of toilet including cleaning of surfaces.(v) M&L for PCC 1:7:12 type D2 using 40 mm graded stone aggregate as in filling (sunken portion). etc.(vi) M&L for PCC 1:2:4 type B0 using 12.50 mm graded stone aggregate, mixed with incl WPC @ 2% by wt. of cement, as sub base, 75mm thick. (vii) M&L for plastering in CM 1:4, 15 mm thickwith incl water proofing compound at the rate of 2% by weight of cement and finishing the surface seven and fair. |