Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | (B/R PORTION)Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed. |
| 2 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as directed. |
| 3 | Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in- Charge. (Glass shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 4 | S&F 5.5 mm thick toughened frosted/ tinted glass / selected quality glass fixed in Upvc beads (beading included with shutter ) oras in hinge door , partition , windows , automatic doors and similar work including cutting to shape , drilling holes as required complete all as specified and as directed. |
| 5 | S & F solar control film 25 micron reflective type (garware sun control or equivqlent ) complete all as specified and directed . |
| 6 | Demolition of stone slabs , floor andwall tiles of any description or thickness in floors/vertical surfaces, etc laid, bedded and pointed in any mortar, etc complete all as specifed and directed. |
| 7 | M & L for Virified digital Ceramic tilesin any colour Double charged / ultracharged 10 mm thick (square / rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4 etc complete all as specified and as directed . |
| 8 | All as per item no 6 here-in-before but as in skirting on vertical surfaces. |
| 9 | M&L coloured glazed ceramic tiles in vertical surfaces 600X300X7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick cement plaster in CM 1:4 complete all as specified and directed. |
| 10 | M&L anti - skid, full body,Vitrified tiles Matte finish ( any colour plain or highlight , Light / Dark shade ) 9 to 10 mm thick Size of tiles shall not be less than 600mmx 600mm , in floor / skirting / dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4 etc complete all as specified and as directed . |
| 11 | Demolition of cement concrete of any description and in any position not other wise specifically provided for and throw out debrises out of the mod land complete all as specified and as directed. (upto 04 storey High of building) |
| 12 | M&L 25mm thick PCC 1:2:4 Type B-0 ( using 12.50 mm graded crushed stoneaggregate) as in sub base of floor complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building) |
| 13 | M&L preparation of old wall / ceiling surfaces surfaces and applying two coat of plastic emulsion paint over a coat of primer and 3 mm thick wall care putty all as specified. |
| 14 | M&L 12 MM thick seamless waterproof and and termite proof WPC louvers wall panels any colour any design fixed over 5.5mm thick WPC white board fixed with prebond adhesive and screwed to wall / ceiling with corner beading etc , complete all as per manufactures instructions all as specified and as directed. |
| 15 | S&F for 12 mm thick toughned frosted glass as in partitions, railing , automatic doors, sliding door or hinge door and similar work including cutting to shape, drilling holes required complete all as specified and directed. |
| 16 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing, Grauting with cement mortr(1:3), and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts (covered with stainless steel cap) complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 17 | M&L 18-20 mm thick coloured granite tiles,machine cut as in steps, riser of stair cases ,j ambs, pillars,and on floor over 20 mm thick backing layerin cement mortar (1:6) ,set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite tile including rubbing and polishing complete all as specified and as directed. |
| 18 | S&F Block boards 18 to 19 mm thick, grade 2 quality, i n t e r i o r grade, commercial type, fixed with screws to timber frame-work( as in cup board)including taking down old one complete all as specified and as directed. |
| 19 | S&F Decorative laminate type ( 0.9mm thick) of surface finish, colour and pattern as approved, fixed with approved adhesive as peranufacturer\"s instructions complete all as specified and as directed. |
| 20 | S & F Continuous (piano) hinges 40 mm width of flap ,brass, bright finish or electro galvanised complete all as specified and as directed. |
| 21 | S&F brass handel 150 mm long decorative type, extruded brass fabricated type complete all as specified and as directed. |
| 22 | S&F multi purpose cupboard lock, grade -I , size 65 mmcomplete all as specified and as directed. |
| 23 | S&F cupboard magnets heavey duty complete all as specified and as directed. |
| 24 | S&F in repairs for sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete including taking down old one complete all as specified and as directed. |
| 25 | S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 26 | S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 27 | S&F tubes 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed. |
| 28 | All as per itemNo 27 here-in-before but 20mm bore. |
| 29 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall. |
| 30 | S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 31 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key and scrubbing down with water complete All as specified and as directed. |
| 32 | Material and labour for 15 mm thick rendering in cement mortar (1:6) on other than fair face of brick or concrete surface finished even and fair all as specified and directed. |
| 33 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and 2mm thick wall care putty over new surfaces of approved make and necessary scaffolding for any height of the building complete all as specified and directed. |
| 34 | Material & Labour for complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and 2mm thick wall care putty over old surface surfaces of approved make and necessary scaffolding for any height of the building complete all as specified and directed. |
| 35 | Supply and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete all as specified and as directed. |
| 36 | S&F in repairs Aluminium body Hydraulically door closer regulated designation No3universal type, suitable for door shutters of 851 to 1000 in width and weight between 61Kg to 80 Kg and fixed inclding taking down old one complete all as specified and as directed. |
| 37 | Dismantling of floor hearth, wall tiling incl cement mortar bedding( but not backing) removing of serviceable tiles to store and rubbish off the premises complete all as specified. |
| 38 | Taking down Labour ofStripping of old tarfelt including layer of plaster of any description carefully from the roof surface (without damage of roof) and removing outside MD land as directed including roughening surface of old concrete roofing by picking, sweeping, cleaning and washing down with the water to remove dust as directed by Engineer-in-Charge. |
| 39 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer\"s instructions, complete all as specified and as directed :-(a) Rendering 10mm thick in Cement Mortar 1:4, finished even and smooth and curedfor 07 days by Ponding of water over Roof.(b) Preparing fully dried plastered surface as per IS:3067-1966, for further treatment.(c) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.3 Litre per Sqm.(d) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.50 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(e) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. |
| 40 | Providing & fixing false ceiling at :-(a) all heights with GRG (Glass Fibre With Reinforced Gypsum , fully perforated 12mm thick micro tegular edge) false ceiling tiles of perforated Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225 :1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L- shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic raw plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. |
| 41 | M&L for preparation of new plastered surfaces of wall and applying two coat of acrylic distemper over a coat of alkali registant primer with 2mm thick wall care putty. complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building). |
| 42 | M/L complete removal of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping including old putty surfaceetc and applying two coat of oil emulsion distemper over a coat of alkali registant primer and coat of wall / ceiling putty ( 2mm thick) to match with the new suface on wall and ceiling ,complete all as specified and as directed by Engineer-in-charge.( incl necessary scaffolding ,upto 04 storey High of building). |
| 43 | Supply and fixing factory made uPVC white colour Sliding window Three track,made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Including Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) |
| 44 | S&F stainless steel wire cloth, 0.65mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as directed. |
| 45 | S&Fpowder coated anodised aluminium frame forpartition with one or more rebates ncluding necessary jointing cleats, glazing clips rubber packing cleat for fixing etc complete all as specified. |
| 46 | S&F Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination n, fixed with screws to timber frame work / aluminium frame work etc complete all as specified and as directed. |
| 47 | S & F 2nd class HW plain solid straight chowkats and frames,wrought, framed rebated on the solid rounded or chamfered put together with glue pinned joints complete all as specified and as directed. |
| 48 | S&F in repair pre - painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as specified. |
| 49 | Excavation in trenches on soft/ loose soli, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out and Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed. |
| 50 | M&L for hardcore of gauge n exc.63 mm broken bricks deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled/rammed to a true surface all as specified and directed. |
| 51 | M&L for Cement concrete TYPE B0 1:2:4 (12.5mm aggregate) in foundations, filling and mass concrete, damp proof course etc. all as specified and directed. |
| 52 | Material and labour for providing Plain Cement Concrete (1:4:8) type D2 using 40 mm graded aggregate as in foundation, filling and mass concrete all as specified and directed. |
| 53 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering as specified and directed. |
| 54 | S&F Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 55 | All as peritem No 54 above, but 6mm to 8mm dia. |
| 56 | M&L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete as specified and directed. |
| 57 | M&L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) Columns, pillars, piers, posts and struts as specified and directed. |
| 58 | M&L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as specified and directed. |
| 59 | M&L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span as specified and directed. |
| 60 | M&L for Formwork for flat/curved roughly finished surfaces to sides of concrete foundations, footings, bases of columns,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batteretc. as specified. |
| 61 | M&L for Formwork for flat roughly finished surfaces to sides of rectangular, square or polygon shape pillars, posts, struts, piers, columns and stanchionsetc. as specified. |
| 62 | M&L for Formwork for flat roughly finished surfacesto soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc. as specified. |
| 63 | M&L for Formwork for flat roughly finished surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. etc. as specified. |
| 64 | M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in1:4 cement mortar complete all as specified and directed. |
| 65 | M&L for preparation of new surfaces and applying two coats of OBD over alkali resistant primer on walls, all as specified and directed |
| 66 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly . ) |
| 67 | Supply only integral water proofing compound all as specified and as directed. |
| 68 | Material and labour for 10 mm thick rendering in cement mortar (1:3) on fair face ofconcrete surface celing finished even and fair all as specified and directed. |
| 69 | M&L for Providing edge moulding to 18-20mm thickness of granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. completeall as specified. |
| 70 | M&L 1.00 mm thick Plain, black, mild steel sheeting, in wall cladding, steel gates,in ridges, hips, valley gutters, drip and straight flashings and similar work cut to size, holes punch headed screws clout nails or rivets and fixed to woodor steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angle etc are required complete all as specified and directed. |
| 71 | Cutting Holes in brick walls in cement mortar for inserting holdfast ,pipes or steel sections and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but n exc one brick etc. all as specified and directed. |
| 72 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. all as specified |
| 73 | M&L forpre- polished kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer or mortar 20 mm thick for laying floor finishes in CM 1:4 complete all as specified and directed. |
| 74 | M&L for pre-polished kota stone slab flooring 18-20 mm thick in riser of steps,skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15 mm thick for in CM 1:4 for wall tiling etc. complete all as specified and directed. |
| 75 | M & L for brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as a specified and as directed. |
| 76 | M&L for providing 50 mm thick PCC (1:2:4) type \"B-4\" (using 20 mm graded crushed stone aggregate), on top of roof, mixed with water proofing compound @ 200 ml per bag of cement, surface finished even and smooth without using extra cement including complete all as a specified and as directed. |
| 77 | M & L for rendering 10mm thickon fair faces of concrete surfaces of any type in cement mortar 1: 4 under APP membrane finish rendering surfaces even and smooth with out using extra cementmixed with WPC @3% by weight of cement or as per manufacturer instruction. Complete all as specified and directed (Note:- WPC shall be mesured and paid separately) |
| 78 | M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as a specified and as directed. |
| 79 | M&L for preparation of new steel and iron surfaces of any description, n. exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as a specified and as directed. |
| 80 | M&L cement concreteType C2 (1:3:6) using 40 mm graded stone aggregate, 75 mm thick as in plinth protection, laid in alternate bays, finished even and smooth without using extra cement, complete all as specified and directed. |
| 81 | M&L providing 50 mm thick bed of plain cement concrete of type D-2, 1:4:8 (40 mm aggregate) for laying of tiles on screed bedcomplete all as a specified and as directed. |
| 82 | M&L for Spreading and levelling 50cm thick bedding of sand in layers n exc. 25 cm thick with compaction by well ramming including watering as required all as specified and directed. |
| 83 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete as specified. |
| 84 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete all as specified. |
| 85 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness including cover fillets complete all as specified |
| 86 | M&L anodised aluminium snap grid with powder coated frame work for false ceiling of size 605x605 mm including 6mm dia Gl (upto 1200mm length) hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of Gl flat 40x3 mm size 60 mm long and expansion hold fasteners 12 5mm dia 40 mm long complete all as specified |
| 87 | M&L 4mm non asbestos fibre cement building boards flat, fixed or laid/inserted to timber/Gl/aluminium frame work with screws complete and applying two coats of Oil bound distemper over a coat of primer complete all as specifed |
| 88 | Taking Down aluminium partition, window or door including builders hardware as specified and directed. |
| 89 | Supplying and installinguPVC- 1sash casement door made out of lead free green profiles having a worldwide presence with a GREENLINE mark with frame dimension of 58mm x 69mm x 50mm and sash 58mm x 93 x 54mmwith corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent. Scaffolding if required will be charged at actuals. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 (without glass)5 and Environmental Management System ISO 14001-2015 Make Kommerling or equivalent model in Fanesta & in other approved makes. |
| 90 | Supplying and installing uPVC- Sliding windows/doors made out of lead free green profiles having a worldwide presencewith a GREENLINE mark having two tracks and two sashes (shutters) and one flyscreen sash with frame dimension of 88mm x 49mm and sash dimension of 61mm x 47mm x 37 mm and flyscreen sash dimension of 32mm x 58mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 (without glass) |
| 91 | S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawingcomplete all as a specified and as directed. |
| 92 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawingcomplete all as a specified and as directed. |
| 93 | M&L for preparation of new surfaces and applying two coats of OBD over alkali resistant primer after applying 2 mm thick wall care putty on walls, all as specified and directed |
| 94 | M & L for preparation of surfaces of walls and applying two coat of Oil Bound Distemper over a coat of alkali resistant primer and 1 mm thick wall care putty after complete removal of existing treatment, all as specified and directed |
| 95 | M&L for preparation of old decorated plastered surfaces or un plastered surfaces of wall and applying one coat of white wash complete all as specified |
| 96 | M&L for preparation of old decorated plastered surfaces or un plastered surfaces of ceiling and applying one coat of white wash complete all as specified |
| 97 | (E/M PORTION)Taking down copper/ aluminium point wiring (light, fan, buzzer, socketor power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etccomplete all as a specified and as directed. |
| 98 | M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit(ISI marked) for modular point wiringwith accessories such as bends, cross, elbow, tees etc. of suitable sizefor mounting switches, sockets, fan regulators etc and including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan/ceiling fan/ call bell point pointcontrolled by one switch Note : Wiring Color code i.e. Red/Yellow/Bluefor Phase, Black for neutral and Green for earth shall be maintained.( for concealed wiring chase cutting will be measured and paid seperately.)For modular point wiring, sunken plate and modular plate will be measured and paid seperately. |
| 99 | All as per item No 98 above but for one three pin socket outlet on same board |
| 100 | All as per item No 98 above but for one three pin socket out let 5 amps on independent board. |
| 101 | Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting modular type switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.(NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same.(ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)(a) One light point or one fan point controlled by one switch |
| 102 | All as per item 101 above but using one 3/5 pin socket outlet, 5 Amp independent |
| 103 | All as per item 101 above but using one 3/5 pin socket outlet, 5 Amp on the same board with other switches |
| 104 | All as per item 101 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches |
| 105 | S&F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 106 | S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed. |
| 107 | S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 108 | S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 109 | S&FCeiling rose surface type 3 terminals 65x20mm compelete all as specified |
| 110 | S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 111 | S&F Switch socket outlet 3 pin 6 amp\" flush type complete all as specified and directed. |
| 112 | S&F Modular Bell push 6A 1 module complete all as specified and directed. |
| 113 | S&F Bell Multi Music type complete all as specified and directed. |
| 114 | S&F Fan step regulator, 120W - 2 module complete all as specified and directed. |
| 115 | S&F White cover plate with frame, 1 module complete all as specified and directed. |
| 116 | S&F White cover plate with frame, 2 module complete all as specified and directed. |
| 117 | S&F White cover plate with frame, 3 module complete all as specified and directed. |
| 118 | S&F White cover plate with frame, 4 module complete all as specified and directed. |
| 119 | S&F White cover plate with frame, 6 module complete all as specified and directed. |
| 120 | S&F White cover plate with frame, 8 module complete all as specified and directed. |
| 121 | S&F White cover plate with frame, 12 module complete all as specified and directed. |
| 122 | S&F Metal flush box 1/2 module complete all as specified and directed. |
| 123 | S&F Metal flush box 3 module complete all as specified and directed. |
| 124 | S&F Metal flush box 4 module complete all as specified and directed. |
| 125 | S&F Metal flush box 6 module complete all as specified and directed. |
| 126 | S&F metal flush box, 8 module complete all as specified and directed. |
| 127 | S&F metal flush box, 12 module complete all as specified and directed. |
| 128 | M & L for point wiring with 4.00 sqmm (Nominal Area) FRLSPVC insulated un sheathed multi stranded copper conductor, 1100 Volts gradefor 3 Pin socket outlet 15Amps on independent board with PVC conduit (ISI Marked) medium duty not less than 20mm diawith accessories such as elbow, tees,internal & external bend etc. of suitable size including continuous earth wire FRLSPVC insulated 4.00 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified. Note : 1) Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. 2) Necessary chase cutting for conduits if requires, shall be measured & paid separately under respective items in this schedule. |
| 129 | S&F modular Switch Socket combination outlet 6 pin 16 Amps flush type complete all as specified and directed. |
| 130 | S&F AC Starter of 32 Amps Alongwith Plug top complete all as specified and directed. |
| 131 | M & L for sub main wiring withsingle core PVC insulated unsheathed , 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade,cable 4 sqmm copperconductor and connected to common earth dolly complete as directedincluding taking down old submain wiring.Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) chase cutting if required shall be measured and paid separately under relevant items in this schedule. |
| 132 | All as per Srl. Item No. 131above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor. |
| 133 | All as per Srl. Item No. 131above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor. |
| 134 | Supply and fix MCB SP 240V, 6-32 Amps capacity complete all as specified and directed. |
| 135 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity40 to 63 AMPin the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 136 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunsheds, shelves, lintel etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting n exc 10 cm girth on brick wall all as directed |
| 137 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexiblecopper conductor cable of suitable size complete all as specified and directed. |
| 138 | S & F in repairLED Ceiling light fitting 35/36 Wrecess / Surface typy as in repair, minimum colour temperature 6500K, with suitable driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specifide and directed. Make: Crompton LCTLSN-36-CDL or equivalent make specified in tender. |
| 139 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 140 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. |
| 141 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote complete all as specified and directed. |
| 142 | Supply & fixAir Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed. |
| 143 | Supply & fixTP&N Vertical Loadline Dbs are fitted with Bus Bars, Neutral Links, Blanking Plates 6 way double door DB LL 4W DD VERT W/O MCCB complete all as specified and directed. |
| 144 | Supply & fix MCCBs 415V, 16KA, 4 Pole 100Amps complete all as specified and directed. |
| 145 | S & F Double door sheet metal enclosure for DBs(Premium range) for mounting of MCB for 240 Volts 8 Way with 100 Amps rated copper bus bar,single pole and Neutral complete all as specified and directed. |
| 146 | Supply only MCB, \"C\" series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. |
| 147 | Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed by Engineer-in-Charge |
| 148 | Excavation in Trenches exc. for each additional 1.5m or part thereof in depth beyond the first 1.5 m for laying of steel tubular pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed. |
| 149 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed by Engineer-in-Charge |
| 150 | Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed. |
| 151 | M&Lfor sand cushioning as per para 19.75 of SSR Part-I(2009) in trenches for underground cable protection and consolidated and compacted with clean dry sandcomplete all as specified and directed by engineer-in-charge.NOTE: Punned thickness only shall be measured for payment. |
| 152 | M&L for Brick protection with subclass ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified. |
| 153 | Supply, Laying, jointing and testingXLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles complete all as specified and directed for the following sizes and cross sectional area :- (a)10 Sqmm, 4 core |
| 154 | M&L for replacement of Pole Mounted Junction Box 254 x 180 x 111mm, having insulated and made out of thermoplastic Polycarbonate with glass fibre reinforced, rated for Degree ofIngress Protection IP 66 in accordance with IEC 60529, IK 07, weather proof for outdoor installation (with knockouts for cable entry) having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at 650°C, with Plastic Mounting Bracket, Din Rail, Mild Steel Flat Iron Clamp, Nuts, Bolts and Washers, with MCB SP 6 Amps, \"B\" Curve, 10 KA, complete all as specified and as directed. MAKE: CAPE Electric Model No.TKPS 2518 - 11M or HENSAL cat Pt No. KF 2525B or equivalent make specified in tender. |
| 155 | S&F in replacement of PVC insulated multistranded copper conductor wire, 1.5 Sqmm 3 Core, round flexible for connection of light fittings, complete all as specified and as directed. |
| 156 | Supply and fixingupto 3 meter Decorative lighting pole of Cast Iron material with P.U painted finish and pole thickness 2-4 mm and base dia 100-150 mm, top dia 50-60mm with tubular shape without arm type complete all as specified and as directed. |
| 157 | S&F LED Bollard light 8W to10W,Oval/Mushroom type luminaire with soft 360 degree light distribution, with IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed. (Make :CGL CAT NO- LBLSR 10-WW/HAVELLS CAT NO-CONENX4BL8WLED PSYM857TOPCM/ SURYA CAT NO- SLE BL 10W-FLR650 NX or equivalent make specified in tender. |
| 158 | S&F LED post top luminaire, 30-35 watt, with die cast aluminium spigot, spun aluminium powder lantern type coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed.(Make :SURYA, CAT NO: SLE PT 30W-ETPP / HAVELLS-CORALPT 35WLED830PSYMTOPC/ PHILIPS CAT NO-BGP200 LED35 CW PSU GR CPC SPD or equivalent make specified in tenderNOTE: Wire for connection of luminaire shall be measured and paid separately. |
| 159 | S&F LED post top luminaire, 20-30 Watt, with die cast aluminium spigot, spun aluminium powder ,Heritage type coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed.(Make : SURYA, CAT NO: SLE PT 30W-HARY / CGL-LPTH-20-WW/ JAGUARCAT NO-LGTP02X030XWor equivalent make specified in tenderNOTE: Wire for connection of luminaire shall be measured and paid separately. |
| 160 | Material and labour for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundations of poles, as mass concrete, complete all as specified and directed. |
| 161 | Material and labour for PCC (1:3:6) type C-2 using 20 mm graded crushed stone aggregate as in plinth cources, string cources, etc., complete including slightly rounded or chamfered for GI tubing post for ait termination rod etc., including using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed. |
| 162 | Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed. |
| 163 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail