| 1 | S&F vitreous China wash basin, white, flat back, size 550x400mmincluding brackets cutting forand pinning in ends of brackets or erecting stand, and 32 mm bore Waste coupling of PTMT (half or full hreaded) .(Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 2 | S&F 75mmbore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 3 | M&L Glazed ceramic coloured tiles in vertical surfaces 300x 600x 7 mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 4 | M&L Non - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 5 | M&L Non - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 6 | M&L Granite (of any type) tiles 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including including 20 mm thick Screed bed or bedding layer of cement mortar 1:6, demoliation of existing Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar etc. complete all as specified and directed. |
| 7 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 8 | M&L Cement concrete type C2, 1:3:6, (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 9 | S&F Polythene film, black, 150micron laid in floors complete all as specified and directed. |
| 10 | M&L 40mmthick cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregate as in floor finished even and fair complete all as specified and directed. |
| 11 | M&L 75mmthick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 12 | M&L Cement concrete type B2, 1:2:4, (40mm graded aggregate) as in Cement concrete in surface channels and drains complete all as specified and as directed. |
| 13 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 14 | Add to or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.Note:- Rate quoted is for adjustment of rate only for the actual size excuted at site for the item no 87 mentioned as above |
| 15 | S&F Expanded metal, weight not exc 4Sqm/Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members including necessary prepration of surface and applying a coat of red oxide zinc chrome primercomplete all as specified and directed. |
| 16 | S&F 0.8mm thick Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and as directed. |
| 17 | S&F 0.8mm thick Plain, galvanised, mild steel sheeting, in ridges,hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 120 complete all as specified and as directed. |
| 18 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in cement mortar 1:6complete all as specified and directed. |
| 19 | M&L rendering 20mm thick with cement mortar 1:4on fair faces of brick workin two layers (10mm and 10mm) sperately mixed with water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and faircomplete all as specified and directed. Note:- WPC shall be measured & paid separately |
| 20 | M&L for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 21 | M&L for Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 22 | M&L for preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 23 | M&Lpreparation of new steel surfaces of any description over 10cm width or girth and applyingtwo coats of synthetic enamel paint complete all as specified and directed. |
| 24 | M&L preperation of new surfaces of wall and applying three coats of white wash,complete all as specified and as directed |
| 25 | S&F Rolled mild steel sections as in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc.confirming to Fe.290. Gde-E-165 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 26 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primercomplete all as specified and directed. |
| 27 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 28 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 29 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 30 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil & getting out, complete all as directed. |
| 31 | Excavating over areas, exc 1.5 m and not exc 3.00 m deep and getting out soft/loose soil & getting out, complete all as directed. |
| 32 | Surface excavation in soft/loose soil, n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out, complete all asdirected. |
| 33 | Excavation in trenches n.exc. 1.5 m width and n.exc. 1.5 m in depth for foundation, laying of UG cable, pipe etcin soft/loose soil & getting out, complete all as directed. |
| 34 | Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 35 | Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all asdirected. |
| 36 | M&L plain cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 37 | M&L providing plain cementconcrete type B-1, (1:2:4), (using 20 mm graded stone aggregate), as in copings, kneelers, apex stones, bed plates, and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 38 | M&L RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate) for Chimneys and shafts complete all as specified and directed. |
| 39 | M&L RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and directed. |
| 40 | M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, banding spirally for hooping columns, hookingend and binding with and includingmild steel wire not less than 0.90 mm dia (annealed) complete all as specified anddirected . |
| 41 | S & F mild steel TMT bar 5 mm dia and over upto and including 10mm dia in strrups as inincluding cutting, bending and binding with and including mild steel not less than 0.9 mm dia (annealed)complete all as specified anddirected . |
| 42 | M&L Formwork to Formwork to sides of chimneys and shafts, vertical or to batter, square, rectangular or polygonal, rought finished surfaces of concerete complete all as specified and directed. |
| 43 | M&L Formwork to faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed. |
| 44 | M&L Pre-cast cement concrete block masonry using Type B1 1:2:4 (20 mm graded aggrgate) with solid blocks, exc. 10 cm in width and setting in mortar,1:6 complete complete all as specified and directed. |
| 45 | M&L Pre Cast RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate cover slab as in drain cover, manhole cover, etc, set in cement mortar 1:6 complete all as specified and directed. |
| 46 | S&F 110mm bore UPVC (SWR) heavy duty soil waste drain pipeconforming to IS 13592, single socketed, in any length with rubber rings laid in trenches complete all as specified and as directed. |
| 47 | S&F 110mm bore UPVC (SWR) bends of any radius complete all as specified and as directed. |
| 48 | S&F 150mm bore UPVC (SWR) heavy duty soil waste drain pipeconforming to IS 13592, single socketed, in any length with rubber rings laid in trenches complete all as specified and as directed. |
| 49 | M&L Concrete bed to drain pipes of 150mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested; in 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed. |
| 50 | M&L for Brickwork with burnt old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 51 | M&L rendering 15mm thick on fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and fair without using extra cement, complete all as specified and directed. |
| 52 | Supply only integral Water proofing compund, complete all as specified and directed. |
| 53 | M&L Sand filling under floors or in foundations including watering and conosoldiation complete all as specified and directed. |
| 54 | M&L Hardcore of gauge n exc. 63 mm, Broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface,complete all as specified and directed. |
| 55 | S&F Powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, partitionswith one or more rebates including joining cleat for fixing etc. complete all as specified and directedNote:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 56 | S&F Powder coated (thick of power coating not less than 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.and directed.. Note:- (i) Glassshall be measured and paidseperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 57 | Supply only 4mm thick plain sheet glass, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 58 | S&F 75mm MS butt hinges medium weight, complete all as specified and directed. |
| 59 | S&F 15mm bore stop valves fancy type cast copper alloy, chromium plated with long shank and cup, screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. |
| 60 | S&F PVC connection 15mm size with PTMT nuts, 450mm long complete all as specified and as directed. |
| 61 | S&F 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 62 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 63 | M&L 75mm dia of outlet, PVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 64 | Cutting into existing manholes of 150 mm dia for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, complete all as specified and directed. |
| 65 | S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), complete in all as specified and as directed. |
| 66 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 67 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 68 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 69 | S&F 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated,fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 70 | S&F 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 71 | M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell pointcontrolled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators] concealed in walls, withwith back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 72 | M&L concealed point wiring for One one socket outlet 15 Amps point on independent board pointcontrolled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0.7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate fittings] concealed in walls, withand including back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 73 | S&F Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 74 | S&F Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed. |
| 75 | S&F Modular Socket 6 A/ 16 Amps, 6 pin combined 2, complete all as specified and directed. |
| 76 | S&F RCBO for earth leakage, overload and short ciruit protection Double pole 230 Volts, 30mA, suitable for 32 Amps complete all as specified and as directed. |
| 77 | S&F RCBO for earth leakage, overload and short ciruit protection Four pole 415 Volts, 30mA, suitable for 63 Amps complete all as specified and as directed. |
| 78 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 79 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 doubledoor, Triple pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 80 | S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 81 | S&F, 600mm x 600mm ultra slim mounted LED module with high brightness, de-glaring PP diffuser and PS LGP de-glaring sheet for glare free uniform light distribution suitable for grid ceiling LEDluminarie 40 Watt, (or next nearer higher watt) 6500Kwith diffuser to ensure glare free and even light distribution& integrated electronic driver,with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply complete all as specified and as directed. |
| 82 | S&F, VTPN DB, 04 Way, double door,Metal door ,IP-43 IK 09, with MCCB as(upto 125Amps)incomer, and MCB;s as Outgoing , 250Amps rated copper bus bars,earth bar,neutral links, no. of module complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces includingcomplete all as specified and as directed. Note:- MCCB;s/MCB\"s required as Outgoing shall be measured and pair seperately under appropiate items |
| 83 | S&F MCCB 4P, 100 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KAcomplete all as specified and as directed. |
| 84 | S&F air curtain 3 feet, 220 Volts, Single Phase, 50Hz, cover height of minimum 10 feet with maximum velocity of air 23m/sec, air volume 1500CFM (H), 1100 CFM (L), assembly 2 motor 3 Blower Power 200 Watt top sunction, robust construction dully fitted on wall as per manufacturers instruction complete all as specified and as directed |
| 85 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed. |
| 86 | Supply, installation and testing of electric water heater, storagetype, BEE 5 star rated, 25 ltr capacity 230 volts AC, 50 Hz comprising of high wattage heating elementfor instant heating, extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non-ferrous pressure plate withincluding provisionPVC connecting pipes 15mm dia 60mm long with brass coupling (heavy duty) for Hot/Cold connection and necessary grouting bolts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable/flexible chord complete all as specified and as directed. |
| 87 | M & L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. |
| 88 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 89 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 90 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 91 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 92 | M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed. |
| 93 | M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means ofbolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab(1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completioncomplete all as specified and as directed. |
| 94 | S&F 400mm sweep wall mounted, oscillating type fan,(BLDC) AC single Phase. 230 Volts with blades, frameand remote (adjustable upward/down wards tilt) connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 95 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 96 | S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete allas specified and as directed. |