Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface Excavation not exc. 30 Cm deep and ave. 15 Cm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 2 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth round, in layers not exceeding 25 cm in soft/loose soilwatering, and removing surplus soil to a distance n exc 50 m and making good surfacecomplete all as specified and as directed. |
| 4 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed. |
| 5 | Removing excavated Material (Soil) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed. |
| 6 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 7 | Supply and laying in trenches Bricks, sub class \"B\" over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed. |
| 8 | Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. |
| 9 | Taking down existing aluminium shutter of area exc 1.0 Sqm but not exc 2.00 Sqm and refixing the same in the same openingafter reparing and make functional including replacement of fitting and fixture for proper functioning as required complete all as specified and as directed. |
| 10 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 11 | M&L Hardcore of gauge not exc. 63 mm, broken brick aggregate deposited, spread andlevelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed. |
| 12 | M&L Moorum/red bajri filling in floors or pavings , laid in lyers 30 cm in thick spread , levelled and rammed including watering complete all as specifiedand directed by Engr-in-charge. |
| 13 | M&L Sand filling under floors or in founda-tions including watering and consolidation, complete all as specified and as directed. |
| 14 | S&F Solid PVC wall lining consisting of5mm thick wood grain printed PVC sheetinclusive of solvent cement and fixing at site on PVC frame as per manufacturer\"s specifications and instructions complete all as specified and directed. |
| 15 | S&F Solid PVC fillets of width 35mm, made of5mm thick PVC sheet, for wall panelling inclusive offixing at site as in grid/frame on wall for fixing wall lining/ panelling as per manufacturer\"s specifications and instructions complete all as specified and directed. |
| 16 | S&F Exposed GI powder coated snap grid frame for false ceiling 600x600mm size of wall angle 25x25x0.55mm size of cross tee and main tee26x24x0.55mmand 32mm x 24mm x 0.55mmwith 3mm dia single GI adjustable suspentor including supply and fixing of 4mm thick E Board decorative type in false ceiling including fixing arrangement from steel tress any type of tress complete all as specified and as directed. (Make: E Board of approved make) |
| 17 | S&F Pre-painted colour galvalume aluminium zinc coating GI based corrugated steelsheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 18 | S&F Pre-painted colour galvalume aluminium zinc coating GI based plain steelsheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 19 | S&F for ACP Sheet of 4 mm thick of any colour, for external wall including necessary frame work (SS/Aluminium as directed)vertically/ horizontally as per manufacturer instruction and approved drawing along with connected accessories of selected quality and approved design for multi storied building incl all necessary scaffolding and safety measurers complete all as specified and directed. |
| 20 | S&F 6-10 mm thick PVC hollow panels with to 0.5 mm plain PVC sheet suitably placed in Wall inclding same and matching colour wall angle , u clip, end elip and jointer . As in ceiling and walls including aluminium frame work fixed to wall or wooden scantling vertically and horizontally at an interval complete all as specified and as directed. |
| 21 | M&L for 0.9 mm thick decorative choice of laminationtype -1 of surface finish , colour and pattern as approved fixed with adhesive or aral Dite epoxy resin Hetex or fevicol etcas per manufacturers instructions complete all as specified and as directed. |
| 22 | Material & Labour in repairs 19/20 mm thick Block boards, grade 1 quality, exterior grade,commercial type, fixed with screws to timber frame-work complete all as specified and directed. |
| 23 | M&L Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 24 | S&F Rolled mild steel sections as in main and cross beams,hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors,fixed with angle cleats or other connecting plates of Fe-410-W(Gde-E-250) quality-B complete all as specified and as directed. |
| 25 | M&L Steel Work in Tubular Trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conform-ing to IS:1161-1979 grade St.-240, complete all as specified and as directed. |
| 26 | M&L Framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing complete Fe 410 -w(Gde E-250) quality B) complete all as specified and as directed. |
| 27 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing powder coated aluminium handle, tower bolt, door stopper as required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and as directed. |
| 28 | S&F powder coated aluminium(Thickness or powder coating not less than 50 micron). window and ventilator shutters, sliding type ,Aluminium Sections weighing 0.55 Kg/Metre including necessary Joining Cleats, Glazing Clips, Rubber Packing, anodised Aluminium Snap Beading, Screws, anodized Aluminium Fittings such as Peg Stays 150mm long (1 No.), Hinges type B-21 100mm long (2 No.), suitable Handle (1 No.), complete all as specified and as directed. |
| 29 | S&F composite 100% solid wood plastic complete (single extended process) material with density not less than 780 kg/cum and plastic wood as in chowkhat complete all as specified and as directed. |
| 30 | S&F Flush Shutters 35 mm thick, Solid Core Construction with Particle Board Core and Plywood Face Panels, Commercial type on Both Sides, complete all as specified and as directed. |
| 31 | M&L Second Class Hardwood Glazed and Skelton Shutter 35 mm thick, open rebated and prepared to receive Glass, Gauze, etc. (without Sash Bars) edges of framing plain, chamfered or rounded, mitred beads for screwing Glass etc., sizes of Members of Shutters as specified in MES Schedule Part I, Section 8, Clause 8.20(a), complete all as specified and as directed. |
| 32 | S&F Factory made solid PVC door frame of size 50mm x 47 mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 33 | S&F Solid PVCdoor frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, complete all as specified and as directed. |
| 34 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting offrame made out of MS tube for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC stiles and plain colour PVC sheets for top rail, lock rail bottom rail on either side & as gap insert for top rail & bottom rail panneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails with suitable PVC sheetbeading & jointed together with solvent cement complete all as specified and directed. |
| 35 | S& F Factory made PVC solid moulded Door Shutter, 30 mm thick with board core (styles), with 2,4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying and fixing in frame at site complete all as specified and directed. |
| 36 | S&F Sheet Glass 4.0mm thick ordinary quality glazing withOil Putty in Square or Rectangular, not exc. 0.50 Sqm, complete all as specified and as directed. |
| 37 | S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.00mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed.NOTE: Cost of Second Class Hardwood Bead-ing shall deemed to be included against Glazed and Skeleton Shutter. |
| 38 | M&L Reinforced Cement Concrete M-25 (Designed Mixed) asin Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 39 | M&L Reinforced Cement Concrete M-25 (Designed Mixed) as in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 40 | M&L Reinforced cement concrete M 25 Design Mix(20mm graded aggregate) in slab supported on walls, beams, and columns, in floors, roof, landings, balconies, canopies, deck slab and in shelves and the like coplete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 41 | M & L for RCC M 25 Beams, roof beam cantilevers, lintels,slabs, balconies, canopies, deck slabs etc. or in similar articles upto 5th floor level complete all as specified and directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 42 | M&L Formwork to Sides of Concrete Founda-tions, Footings, bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of foundation and plinth beams and similar work; Square, rectangular or polygonal, vertical or to batter, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 43 | M&L Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 44 | M&L Formwork toSoffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 45 | M&L Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 46 | M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 47 | M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed. |
| 48 | Mild steel bars 5mm to 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 49 | Supply and fix 75 mm dia of outlet PVC(SWR)floor trap, plain with grating including jointing with solvent cement completeall as specified and directed. |
| 50 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and as directed. |
| 51 | Supply and Laying Steel Water Tubing 15mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 52 | Supply and Laying Steel Water Tubing 20mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete all as specified and as directed. |
| 53 | S&F 20mm bore CPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors incl conceiling/ clamping etc complete all as specified and directed. |
| 54 | S&F 15mm bore CPVC pipes of pressure rating 10 kgf/cm2 fixed complete towalls, ceilings or in floors incl conceiling/ clampingetc, complete all as specified and directed |
| 55 | Supply and fix, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 56 | S&F PVC (SWR) 75mm bore bends any radius complete all as specified and directed. |
| 57 | S&F for PVC (SWR) with access door bend 75 mm dia complete all as specified and directed. |
| 58 | Supply and fix, 110 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 59 | S&F for PVC (SWR) 110mm dia with access door bend complete all as specified and directed. |
| 60 | S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed |
| 61 | Supply and fix, PVC cowls 110 mm bore complete all as specified and directed. |
| 62 | S&F in repair 75 mm borePVC(SWR) junction single (single \"T\") equal or unequal complete all as specified and as directed. |
| 63 | S&Fin repair 110mm bore PVC(SWR) junction single (single \"T\") equal or unequal complete all as specified and as directed. |
| 64 | M&L 150 mm internal dia salt glazed stoneware drain pipes , laid in trenches and jointed as specified complete all as specified and as directed. |
| 65 | S&F Stainless steel butt hinges 100 mm long fixed with SS Screw complete all as specified and directed. |
| 66 | S&F 150mm long aluminium handle, cast type, anodised complete all as specified and directed. |
| 67 | S&F Aluminium anodised barrel tower bolts of extruded section 150 mm long and fixed with screws complete all as specified and as directed. |
| 68 | S&F Aluminium anodised sliding door bolts of size 250 mm long, with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 69 | S & F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed. |
| 70 | S & FAluminium (extruded section body type )door closer hydraulically regulated designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight and weight betwwen 61 to 80 kgordinary rat tail rod pattern springs, including roller and rollerplate complete all as specified and directed. |
| 71 | S & F aluminum mortice lock verticle type 75 mm4/6 levers complete all as specified and as directed. |
| 72 | S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with \"p\" or \"s\" trap front or back inletincluding fixing Bolts with and (excluding 10 litre capacity low levelFlushing Cistern)and providing 32mm dia PVC flush pipe including plastic water closet seat with flat botton cover (coloured) fixed with mild steel chromium plated or aluminium hinging device and making good disturbed Surfaces in Cement Mortar 1:3 and fixed, complete all as specified and as directed. |
| 73 | Supply and fix, bowel urinal flat back of size 465 x 355 x 265mm (minimum), white, with grating and union for discharge pipe, (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinals against wall in cement mortar (1:2) securing urinals to plugs with and including 60 mm brass screws and pointing around urinals back in cement complete all as specified and as directed. |
| 74 | S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a pair of Cast Iron Brackets duly painted including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed. |
| 75 | S&F White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float and Handleincluding Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed. |
| 76 | S & F, waste coupling CP 32/40 mm dia for glazed ware basins etc with fly nuts flanged including 610 mm long waste pipe etc complete all as specified and directed. |
| 77 | S&F Pillar Tap 15mm bore, cast copper alloy, Fancy type, chromium plated, with capstan heads, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed Shanks and Fly-nuts, screwed for Iron Pipe, complete all as specified and as directed. |
| 78 | Supply and fix, 15 mm bore bib taps(not less than 400 gm), cast copper alloy,cromium plated, fancy type, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 79 | S&F Angular Stop Cock 15 mm dia (bore), cast copper alloy, fancy type, chromium plated, screwed down, high pressure,with wall flange screwed for Iron Pipes or Brass Ferrule and fixed, complete all as specified and directed. |
| 80 | S&F PVC connections 15mm size with PTMT nut of length 450mm complete all as specified. |
| 81 | Supply and fix, 32 mm dia PTMT 610 mm long waste pipe suitable for WHBcomplete all as specified and directed. |
| 82 | S&F Auto Closing urinal valve push type alloy CPwith wall flange for 15mm bore of approved make complete all as specified and directed. |
| 83 | S&F Mirror Bevelled Edge 600x450mm, Selected quality Glass, mounted on 6.0mm thick AC Building Board or Commercial Ply-wood and fixed to Wooden Plugs with Chro-mium Plated Brass Screws and Cup Washers complete all as specified and as directed. |
| 84 | S&F Chromium Plated soap dish fixed to wall with necessary fixing arrangement, complete all as specified and directed. |
| 85 | S& F Towel Ring of stainless steel fixedand including Chromium plated brass screwscomplete all as specified and directed. |
| 86 | S&F Tubular Towel rail chromium plated 600mm long 20mm dia D type complete all as specified and as directed. |
| 87 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed. |
| 88 | M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 89 | Cutting chases,pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of ladings, steps, cills,sushades,shelves,lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting grith n.exc.10cm girth on brick walls complete all as specified and as directed. |
| 90 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 91 | M&L Rendering 15mm thick in Cement Mortar 1:4 (Externally) on Fair Faces of Brick Walls or on Concrete Surfaces including mixing with WPC as per manufacturer\"s instructions, Plastered Surfaces finished Even and Smooth without using extra Cement, complete all as specified and as directed. |
| 92 | M & L, 10mm thick rendering in C.M. (1:6) on brick workfinished even and fair without using extra cement complete all as specified and as directed. |
| 93 | M&L Rendering 5 mm thick in patches with CM (1:3) on ceiling Complete all as specefied and directed. |
| 94 | Supply only water proofing compound. Conforming to IS -2645 complete all as specified and as directed. |
| 95 | M&L preparing new Surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and as directed. |
| 96 | M&L Preparing new plastered surfaces of wall and appplying two coats of acrylic exterior weather coat over acoat of primer withdamp proof care andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and evenas per manufacturer instrcution and applied by approved applicatorcomplete all as specified and directed. |
| 97 | M&L forOldwall surface including properly preparation/removal of existing paint surface andfillings the cracks with exterior wall care putty and pigment and applying one coat of weather coat water proofing paints as in boundry wall, single , double and triple storey bldg, completeall as specified andas directed. |
| 98 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls andapplyingTwo coats of exterior emulsion antifungus paint over a coat of primer andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 99 | M&LApplying onecoat of Acrylic Emulsion distemper to old wall surfaces of walls and cornicesincluding preparation of old plastered or un plastered surafce of wall by brooming down or steel wire brushing ,srcaping down smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot complete all as specified and directed. |
| 100 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls andapplying Two Coats of DistemperOil Emulsionover a coat of primer andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 101 | M&L Preparing new Surfaces of Walls andapplying Two Coats of DistemperOil Emulsionover a coat of primer andapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 102 | M& L Texture Crinkle Mat finish paint after preparation of old surface, applying 1 MM thick exterior wall care putty in two layers, with a primer coat & a base coat applied with crinker paper and finished with two or more top coat including necessary arrengement. Shade and colour of paint will be decided at the time of execution, complete all as specified and as directed. |
| 103 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. |
| 104 | S&F Coloured Glazed ceramic tiles 450 x 300 mm x8mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm screeding in Cement mortar 1:4 complete all as specified and directed. |
| 105 | M&L Non - skid Ceramiccolouredtiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar (1:4)complete all as specified and as directed |
| 106 | M&LNon-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular)area of each tile esceeding 0.18 Sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointd in white or coloured cement to match over 15mm tick creed bed in cement mortar (1:4)complete all as specified and as directed |
| 107 | M&L Non- skid Ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm, in Skirting/Dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of surface over 15 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 108 | M&L Glazed Ceramic tiles 8 to 10 mm thick (square/ rectangular) any shade, polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of surface over 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 109 | M&L Glazed Ceramic tiles 8 to 10 mm thick (square/ rectangular) any shade, polished, area of each tiles not exceeding 0.36 sqm asin skirting /dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of surface over 10mm screeding in Cement mortar 1:4, complete all as specified and directed. |
| 110 | M&L Vitrified Ceramic Tiles 10 mm thick (square/ rectangular) in Light Shade, Polished, size of each Tile600mm x 600mm as inFloors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed in cement sand mortar (1:6)complete all as specified and as directed. |
| 111 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, complete all as spcified and directed. |
| 112 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 113 | M & L for providing Plain Cement Concrete (1:2:4) type B0 using 12.5mm graded aggregate as in copings,levelling course in lintels, cills,plinth courses, string courses,lacing courses, parapets water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 114 | M & L for PCC 1:2:4 Type B0 25 mm thick as in damp roof course to horizotal and verticle including necessary from work complete all as specified and directed. |
| 115 | M&L for 50 mm PCC 1:3:6 C-1 using ( 20 m graded stone aggregate) as sub floor , sub baseeven and rough to recieve the topping layeras in sub base complete all as specified and directed. |
| 116 | M&L 75mm thick plain cement concrete (1:3:6) type C1 using 20mm graded stone aggregate as in plinth protection & footpath etc and finishing surfaces of concrete even and smooth including making construction joint at interval of 1.5 mtr and every corner andfilled with bituminous fillercomplete all as specified and as directed. |
| 117 | M&L 100 mm thick,Cement concrete, type D-2, (1:4:8), 40 mm graded aggregate as in sub base even and rough to receive topping layer complete all as specified and directed |
| 118 | M&L 75 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate)as in sub base/floor to receive topping layer etc as a levelling course complete all as specifed and as directed. |
| 119 | M&L P.C.C (1:3:6) type C2 using 40 mm graded stone aggregate for bed to drain pipes including packing under and hunching against side of pipes after they are laid down and tested complete for 150 mm bore pipe complete all as specified and as directed. |
| 120 | M&L Granite (of any type) Work (Table rubbed and polished) 18 to 20 mm thick, in Steps, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges, complete all as specified and as directed. |
| 121 | M&L Granite (of any type) Work (Table rubbed and polished) 18 to 20 mm thick as in skirting/border with 12 mm thick in cement mortar (1:3) including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges, complete all as specified and as directed. |
| 122 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 123 | M&L preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 124 | Supply and fix Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position size 500 ltrs all as specified in SSR Part I including all its accessories complete all as specified and as directed. |
| 125 | Supply, lay and fix 25 mm bore galvanized iron water tubing medium grade including all fittings and fixed laid in trenches complete all as specified and directed. |
| 126 | S&F 15 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions complete as all specified and as directed. |
| 127 | S&F 20 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions, complete as all specified and as directed. |
| 128 | S&F 25 mm bore Gun metal gate valve as per IS : 778-84,marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions, complete as all specified and as directed. |
| 129 | Supply and fix Ball valves 25 mm dia high epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 130 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(ii) cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. |
| 131 | All as per item No. 130 above but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and as directed. |
| 132 | All as per item No. 130 above but for 5 Amps socket point on the same board controlled by one switch. |
| 133 | All as per item No. 130 above but for 15 Amps socket combination on independent board with 2.5 sq mm copper cable complete all as specified and as directed. |
| 134 | S&F Modular switch flush type, 6 Amp, one way ,1 module complete all as specified and as directed. |
| 135 | S&F Modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and as directed. |
| 136 | S&F Modular socket outlet, 3 pin, 6/16 Amp, flush type 2 module complete all as specified and as directed. |
| 137 | S&F Modular Fan Regulator stepped type 2 module, 120W complete all as specified and as directed. |
| 138 | S&Fceiling rose surface backelitethree terminals complete all as specified and as directed. |
| 139 | Supply and fix LED tube light fitting of 18 W with tube (4 Ft) 240 V Wall mounted LED batten polycarbonate houseing and integrated electronic driver with high efficient LEDs 18 Watt with acessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories internally pre-wired and inclg connection complete all as specified and as directed. |
| 140 | Supply and fix LED tube light fitting of 9W with tube (2 Ft) 240 V Wall mounted LED batten polycarbonate houseing and integrated electronic driver with high efficient LEDs 18 Watt with acessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories internally pre-wired and inclg connection complete all as specified and as directed. |
| 141 | Supply and fix for Recess/Surface mounting high lumen output LED light fittings for metallic false ceiling type armstrong/US gypsum or similar ceiling mounting system with concealed or exposed \"T\" section including 12 watt LED CDL light, complete all as specified and as directed. |
| 142 | S & F in replacement 25 W LED outdoor New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminum landscape luminaries with high power LEDs as light source with IP 65/66 , IK-07 protection complete all as specified and directed. |
| 143 | S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with common bus bar at incomming end. complete all as specified and directed |
| 144 | S & F MCB \"C\" series Single pole and nutral 32 Amps, breaking capacity 10KA,complete all as specified and directed. |
| 145 | S & F MCB \"C\" series single pole 6 to 32 Amps, breaking capacity 10KA, complete all as specified and directed. |
| 146 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawninto rigid non metalic PVC conduit of size 20 mm dia including all fittingscomplete all as specified and as directed.Note:- Two runsof 4 Sqmm conductor as main wireand one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 147 | S & FExhaust Fan of Size 250 mm sweep, 230Volts AC, PVC Body with connection from existing ceiling rose incl cutting hole and making good disturbed surface and necessary fixing arrangements complete all as specified and directed. |
| 148 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motorcomplete all as specified and directed. |
| 149 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core. Note:1. Excavation and earth work will be measured and paid seperately. |
| 150 | NOTES:1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule \"A\" notes for details. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail