| 1 | Dismantling wall and ceiling boards (Fibre pulp,insulation boards/slab/blankets, any thickness incl cover fillets complete all as specified and directed. |
| 2 | S&F for Solid PVC Wall Lining consisting of 5 mm thick prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed. |
| 3 | S & F 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to RCC/Brick wall to make PVC Frame complete all as specified and directed. |
| 4 | Demolition of Concrete unreinforcement in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 5 | M&L for Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed. |
| 6 | M & L for cement concrete type D-21:4:8(using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 7 | Taking down door shutter with chowket of size exc 1.5 Sqm but not exc 4 Sqm each without taking off shutter from the framecomplete all as specified and directed. |
| 8 | S&F for 3 mm thick MS plates chequred or plain squared cut and attachment grade A Fe-410-W Gde E-250 complete all as specified and directed. |
| 9 | S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 10 | Taking downcement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 11 | M&L 10 mm thickplasterin CM 1:4 on brick wall finished even & smooth without using extra cement in patches complete all as specified and directed. |
| 12 | Complete removal to existing wall treatment and material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 13 | Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering & removal of debris outside MOD complete all as specified and directed.NOTE :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work |
| 14 | M&L PCC 1:2:4 type B1 using 40 mm graded stone aggregate as in concrete padding laid to required slope incl finishing the concrete surface fair and even without using extra cement complete all as specified and directed. |
| 15 | M & L for 10 mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finished with WPC 3% by weight of total cement, complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately. |
| 16 | Supply only water Integral proofing compound complete all as specified and directed. |
| 17 | Supply and laying a coat of oxidised bitumen based solvent primer @ 0.3kg/sqm complete. |
| 18 | Supply and laying for APP 3mm thick unrolled over the bitumen coated surface polymeric water proofing membrane Hyperplas standard wt not less than 3kg/sqm with 100mm over laps shall be sealed by flame as per manufactures instruction completely all as specified and directed. |
| 19 | M&L for preparation of new surfaces of any description not otherwise described over 10cm width or girth and applying two coats of solar reflective aluminium paint @ 0.10 kg/sqm on membrane surfaces complete all as specified and directed. |
| 20 | Deduct schedule of credit amount Rs. 6670.00 to be deducted during AOC |