| 1 | Detailed survey investigations, planning, preparation and approvalof detailed drawings and designs andconstruction of permanent living accommodation, Officer’s mess, Supvr’s/JCO’s mess, NCO’s & OR’s mess including foundation, plinth, partition wall, slabs, flooring, fixing of doors & windows, including septic tank, soak pit, parkings, fire fighting equipment, toilet & bath room fittings, internal/external finishes with electrical & water supply fittings, drainage, kitchen cabinets, antitermite treatment, water proofing, damp proof course, plinth protection, wardrobes fittings, staircase, varanda, balcony, lobby including landscaping complete in all respect all as specified in particular specifications and as directed by OC Contract/Engineer-in-charge. Refer Para 22 of Sch ‘A’ notes at tender Page No 244. |
| 2 | Soil investigation, preparation of architectural and structural design for RCC Single storied framed structure with concrete roof slab, drawing, proof check and Construction of Officer Mess (01 nos Qtr 162 Sqm) with additional extra height 0.30 Mtr, extra plinth height 0.30 Mtr for GF only, Automatic Fire Alarm System with Extra Foundation Depth height 0.60 Mtr for GF only complete in all respect as specified in special condition and particular specifications including water supply system, sanitary/plumbing works, electrifications, sewage disposal and area drainage system as directed by OC Contract/Engineer -In- Charge. |
| 3 | Leveling of work site for development of Officer’s Mess area |
| 4 | Horticulture operation including 300 mm earth filling, grassing tree plantations/ Shurbs and potted plants etc for development of Officer’s Mess area. |
| 5 | Soil investigation, preparation of architectural and structural design for RCC Single storied framed structure with concrete roof slab, drawing, proof check and Construction of Supvr’s/JCO’s Mess (01 nos Qtr 149 Sqm) with additional extra height 0.30 Mtr, extra plinth height 0.30 Mtr for GF only, Automatic Fire Alarm System with Extra Foundation Depth height 0.60 Mtr for GF only complete in all respect as specified in special condition and particular specifications including water supply system, sanitary/plumbing works, electrifications, sewage disposal and area drainage system as directed by OC Contract/Engineer -In- Charge. |
| 6 | Leveling of work site for development of Supvr’s/JCO’s Mess area |
| 7 | Horticulture operation including 300 mm earth filling, grassing tree plantations/ Shurbs and potted plants etc for development of Supvr’s/JCO’s Mess area. |
| 8 | Soil investigation, preparation of architectural and structural design for RCC Single storied framed structure with concrete roof slab, drawing, proof check and Construction of NCO’s Mess (01 nos Qtr 85 Sqm) with additional extra height 0.30 Mtr, extra plinth height 0.30 Mtr for GF only, Automatic Fire Alarm System with Extra Foundation Depth height 0.60 Mtr for GF only complete in all respect as specified in special condition and particular specifications including water supply system, sanitary/plumbing works, electrifications, sewage disposal and area drainage system as directed by OC Contract/Engineer -In- Charge. |
| 9 | Leveling of work site for development of NCO’s Mess area. |
| 10 | Soil investigation, preparation of architectural and structural design for RCC Single storied framed structure with concrete roof slab, drawing, proof check and Construction of OR’s Mess (01 nos Qtr 162 Sqm) with additional extra height 0.30 Mtr, extra plinth height 0.30 Mtr for GF only, Automatic Fire Alarm System with Extra Foundation Depth height 0.60 Mtr for GF only complete in all respect as specified in special condition and particular specifications including water supply system, sanitary/plumbing works, electrifications, sewage disposal and area drainage system as directed by OC Contract/Engineer -In- Charge. |
| 11 | Leveling of work site for development of OR’s Mess area. |
| 12 | Soil investigation, preparation of architectural and structural design for RCC double storied framed structure with concrete roof slab, drawing, proof check and Construction of Type-II Married accommodations (4 nos Qtr 75 Sqm each in 02 floors i.e. 02 Qtr per floor) with additional extra height 0.30 Mtr, extra plinth height 0.30 Mtr for GF only, Automatic Fire Alarm System with Extra Foundation Depth height 0.60 Mtr for GF only complete in all respect as specified in special condition and particular specifications including water supply system, sanitary/plumbing works, electrifications, sewage disposal and area drainage system as directed by OC Contract/Engineer -In- Charge. |
| 13 | Soil investigation, preparation of architectural and structural design for RCC double storied framed structure with concrete roof slab, drawing, proof check and Construction of Type-III Married accommodations (4 nos Qtr 85 Sqm each in 02 floors i.e. 02 Qtr per floor) with additional extra height 0.30 Mtr, extra plinth height 0.30 Mtr for GF only, Automatic Fire Alarm System with Extra Foundation Depth height 0.60 Mtr for GF only complete in all respect as specified in special condition and particular specifications including water supply system, sanitary/plumbing works, electrifications, sewage disposal and area drainage system as directed by OC Contract/Engineer -In- Charge. |