| 1 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses,regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc including making good the disturbed surfaces to match with adjoining surfaces complete all as specified and as directed. |
| 2 | M & L for PointWiringwithsingle core PVC insulated unsheathed FRLS 1.5 Sqmm multi strandedcopper conductorcable 1100 volts grade conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling includingM S terminal boxes fabricated with 1.6 mm thick M S sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed :- |
| 3 | One light / fan point controlled by one switch |
| 4 | One lightpoint controlled by two wayswitch |
| 5 | One 3 pin socket out let 5 Amps on independent board |
| 6 | One 3 pin socket out let 5 A on same board |
| 7 | One Bell / Buzzer Point controlled by bell push |
| 8 | M & L for PointWiringwith single core PVC insulated unsheathed FRLSmulti stranded with copper conductor 2.5 Sqmmcable 1100 volts gradeconforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling including M S terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including2.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 9 | S & F in repairsSub main wiring with 2 runs single core 6 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 6 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed.(Note : Three run of 6sqmm cable and one run of conduit pipe altogether measured as one unit) |
| 10 | S & F in repairsSub main wiring with four runs single core 4 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 4 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed.(Note : Five run of 4sqmm cable and one run of conduit pipe altogether measured as one unit) |
| 11 | S & F in repairsSub main wiring with four runs single core 10 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 10 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed.(Note : Five run of 10sqmm cable and one run of conduit pipe altogether measured as one unit) |
| 12 | Note for Item No 2 & 6 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the quoted rate(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in the quoted rate(v) Cost of a cutting chases deemed to be included in the quoted rate |
| 13 | All as per item No 2herein beforebut concealed wiring drawn through existing PVC conduit:- |
| 14 | One light point controlled by one switch |
| 15 | One fan/Exhaust point controlled by one switch/regulator |
| 16 | One light point controlled by 2 way switch |
| 17 | One 3 pin socket out let 5 Amps on independent board |
| 18 | One 3 pin socket out let 5 A on same board |
| 19 | S&F LED batten with luminairesuitable for indoor applications 20 Watts, 4 feet long with extruded aluminiumhousing & integrated LED channelwith all accessories all as specified and directed. |
| 20 | S & FSwitch Piano flush type, single pole, one way 5Amps all as specified and directed. |
| 21 | S&F Switch piano flush type, single pole, two way 5Amps all as specified and directed. |
| 22 | S&Fstepped type electronic fan regulator, flushtype Switch / sockettypeall as specified and as directed |
| 23 | S&F Switch socketcombination2in 1 , 5 Amps flush type all as specified and asdirected |
| 24 | S&F switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and asdirected |
| 25 | S&F in repairsMCB SPN 240 volts 32/40 Amps, C curvescomplete all as specified and as directed |
| 26 | S&F in replacement of MCB single pole 240 volts 10/16/20/32 Amps, C curvescomplete all as specified and as directed |
| 27 | S&F in replacement of MCB Distribution boardSPN 8 way, double door type,240 volts with 200 Amps rated busbar allas specified and as directed. |
| 28 | S&F Storage type electric water heater 25 Ltrs capacity,steel body with copper inner tank and heating element upto 2 KW capacity , BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece steel wired pipe for hot/cold water connection for inlet and out let wateretc., testing for smooth functioning at siteincluding taking down of old unserviceable geyser and deposited to MES yard completeall as specified and directed |
| 29 | S&F in repairs MCB Distribution board,TPN 4 way, double door type 240 volts with 200 Amps rated busbaras specified and as directed. |
| 30 | S&F in replacement of MCB Distribution board,VTPN4 way double door type,240 volts with 200 Amps rated busbarall as specified and as directed. |
| 31 | S&F in replacement ofMCBTPN415 volts 10 KA, \"C\" curves 100 Amps capacity complete all as specified and as directed |
| 32 | S&F in replacement ofMCB TPN 415 volts 10 KA\"C\" curves40 Amps capacitycomplete all as specified and as directed |
| 33 | S&F in replacement of MCB Distribution BoardSPN 4 way, double door type 240 volts with 200 Amps rated busbaras specified and as directed. |
| 34 | S&FCeiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals 240 volts all as specified and as directed |
| 35 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in Reincorced cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering pipe wire mesh and lugs,test pointetc including dismantaling old unserviceableearthing etc., complete all as specified and as directed |
| 36 | Supply and fixing in repairs LED bldg securitylight fitting30 Watts capacity with pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection with andincludingGIBracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc dulyapplying two coats of aluminum paintover a coat of red oxide primer complete all as specified and directed. |
| 37 | Supply and fix Exhaust fan 300mm sweep, steel body,AC single Phase230Voltswith, bladesand frame,louvers complete including necessary core cutting in block/brick masonaryfor installation all as specified and directed . |
| 38 | Supply and fix Exhaust fan 450mm sweep, steel body,AC single Phase230Voltswith, bladesand frame,louvers complete including necessary core cutting in block/brick masonaryfor installation all as specified and directed . |
| 39 | S&F Storage type electric water heater 25 Ltrs capacity,steel body with copper inner tank and heating element upto 2 KW capacity , BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece steel wired pipe for hot/cold water connection for inlet and out let wateretc., testing for smooth functioning at site completeall as specified and directed |
| 40 | S&F Storage type electric water heater 50 Ltrs capacity,steel body with copper inner tank and heating element upto 3 KW capacity , BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece steel wired pipe for hot/cold water connection for inlet and out let wateretc., testing for smooth functioningat site completeall as specified and directed |
| 41 | M & L for Galvanised iron tubes 15mm dia bore, Medium grade, with all fitting, laid in trenches completeall as specified and directed |
| 42 | Cutting existing steel tubing for alterations or additions of size 15mm/20mm complete including screwing etc all as specified and directed (Each cutmeasured) |
| 43 | M & L for Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm dia bore or forbrass ferrule and fixed all as specified and directed |
| 44 | M & L forStop valves fancy type, cast copper alloy chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe15mm dia boreor for unions and fixedall as specified and directed |
| 45 | S&FSingl epole neutral enclosure 20 Amps240volts with two pin & earth plug & socket wit one MCB SP20Amps, C curvescomplete all as specified and as directed |
| 46 | S&F MCB SPN 240 volts 32/40 Amps, C curvescomplete all as specified and as directed |
| 47 | S&F MCB single pole 240 volts 32 Amps, C curves230volts complete all as specified and as directed |
| 48 | S & F in repairsSub main wiring with two runs single core 4 Sqmm 1100 volts grade multistranded FRLS copper conductors along with 4 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run through & including suitable size of PVC conduit with accessories specified and as directed.(Note : Three runs of 4sqmm cable and one run of conduit pipe altogether measured as one unit) |
| 49 | S&F MCB Distribution boardSPN 8 way, double door type,240 volts with 200 Amps rated busbar allas specified and as directed. |
| 50 | Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 51 | Returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed |
| 52 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 53 | M & L for sand cushioning under and above the cable for protection all as per Para 19.75 SSR Part-I complete all as specified and as directed(Note : Punned thickness will be measure for payment) |
| 54 | Supply & Layingsub class \"B\" burnt bricks for cable protection complete all as specified as directed |
| 55 | Supply & Laying XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor cable connected with suitable legs including taking out the existing unserviceable cable for following size :- |
| 56 | 3.5 C x 25 Sqmm |
| 57 | 3.5 C x 35 Sqmm |
| 58 | 3.5 C x 120 Sqmm |
| 59 | Supply, testing and commissioning ofweather and vermin proof LT feeder pillar boxfactory fabricated outdoor cubical/kiosk type CPRI approved and confirming to IS 5036totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, |
| 60 | dulypowder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour and bus barforphase & neutral 500 Amps, 36 KA capacity and IP 54 protectionmounted on epoxy insulator-01 Set includingmounting the panel board on ground with PCC 1 :3:6 bedding upto a height of 50 cm above ground level and the size of feeder should not less than 130x 45x 150cmcomplete all asdirected and comprising the following itemsincluding taking out unseviceable LT Panel :-(i) Incoming MCCB4 pole, 250 Amps 36 KA 415 Volts-01 No(ii)Outgoing MCCB4 pole, 100 Amps 25 KA 415 Volts-05 No(iv) Digital Voltmeter 0-500 volts with selector switch - 01 No(v)Digital Amps meter CT operated 0-400 Amps with phase selector switch - 01 Nos(vi)LEDIndicator lamp ( RYB ) - 01 Set (03 Nos) |
| 61 | M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and including galvanized iron strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-Iand as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in Reiforced cement concrete (1:2:4) type B1 with 8 mm TMT bars reinforced at 10 cm centre to centre both ways,funnel with watering pipe wire mesh and lugs,test point complete all as specified and as directed |