| 1 | SCHEDULE \"A\" PART-I : BOQ OF WORKS FOR EXTERNAL ELECTRIC SUPPLY |
| 2 | Replacement of old unserviceable air termination with new air termination, single pointed, copper rod 12mm dia and 300mm long, including fixing arrangment i.e. copper nut, bolt, washers, clamps etc and fixing at site, complete all as specified and as directed. |
| 3 | Test point terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 Nos. 8mm dia, 25mm long hexagonal head screw, including box, size 200mmx100mmx100mm made of 2.0mm thick hot dip plain galvanised iron sheet, drilled and screwed including 6 Nos. 15mm long hexagonal head screws, for fixing for protection of test point, fixing in repairs, complete all as specified and as directed. |
| 4 | Copper strip 20mmx3.15mm with saddles and fixing screws, porcelain insulators etc. for roof conductors and down conductors above ground, complete all as specified and as directed. |
| 5 | Earthing complete with copper earth plate electrode 600x600x3.15mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with copper earth strip 20x3mm as earth lead, by means of copper bolts, nuts, check nuts and washers of copper complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed.Note: (i) copper earth strip size 20x3.15mm and protection pipe of 40mm bore beyond 7.50 meters shall be measured and paid separately.(ii) Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.(iii) Cost of earthing materials i.e. charcoal, dust, salt shall be deemed included in quoted rates. |
| 6 | Replacement of old unserviceable sub main wiring with new sub main wiring in PVC conduit of required size as per site for circuits/ submain wiring along with earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, using colour coding, drawn in and including any type of conduit, any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed.Note: Cost of all three run of wire and one run of conduit of required size will be included in quoted rate. |
| 7 | Single pole and neutral enclosure having rating 40 Amps with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240 Volts, fixed with PVC rawl plug with anti-rusted screws, complete all as specified and as directed. |
| 8 | Supply fixing, installation and testing of hi-wall split air conditioner having indoor/ outdoor units complete with cordless remote-control unit and with cooling and heating function of capacity 2.0 TR, conforming to minimum 3-star rating and energy efficient, operated by AC, 220 Volts, 50 Hz, including installation with complete copper piping of requisite dia for refrigerant functioning, PVC drain pipe along with making good to disturb surfaces as per existing specifications, complete as specified and directed.Make: Diken/ Hitachi/ Voltas/ Blue-Star. |
| 9 | Voltage stabilizer capacity 4.0 KVA suitable for automatic operation of air conditioner, single phase, naturally air cooled, indoor type, designed for input variation between 170 Volts to 250 Volts with out put voltage stabilizer at 230 Volts with accuracy of ±2.50%, complete all specified and directed.Make: Luminous/ Microtek/ V-Guard. |
| 10 | SCHEDULE \"A\" PART-II : BOQ OF WORKS FOR INTERNAL ELECTRIC WORKS. |
| 11 | Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation of pole, etc. or for laying of cable, etc. and getting out, in any type of soil, complete all as specified and as directed. |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed. |
| 13 | Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed. |
| 14 | Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.Note: Punned thickness shall be measured. |
| 15 | Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed. |
| 16 | Tubes, \"light grade\" galvanised, 40mm bore, ISI marked including all fitting such as bends, socket, connectors, back nuts, etc, laid in trenches or under floors, complete all as specified and as directed. |
| 17 | Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed. |
| 18 | Descriptionall as per serial item No- 2.07 here-in-before but for cable ofsize 16.0 Sqmm 2.0-core. |
| 19 | Descriptionall as per serial item No- 2.07 here-in-before but for cable ofsize 10.0 Sqmm 4.0-core. |
| 20 | Point wiring in PVC conduits for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in existing any type of conduit/ new casing and caping, of any dia including all accessories concealed/ exposed, in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti-corrosive paint and with Bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Concealed conduits will be provided where ever required and cost of cutting, chasing and making good to surfaces shall be included in quoted rate. |
| 21 | Description all as serial item No- 2.10 here-in-before but for one 3- pin, 5/ 6-Amps, socket outlet on same board. |
| 22 | Description all as per serial item No- 2.10 here-in-before but for one 3-pin socket outlet 5/6 -Amps on the independent board. |
| 23 | Point wiring in PVC conduits for 3-pin, 15/ 16 Amps, switch socket combination on independent board with 4.0 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including any type of conduit/ new casing and caping, any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 4.0 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Concealed conduits will be provided where ever required and cost of cutting, chasing and making good to surfaces shall be included in quoted rate. |
| 24 | Lamp holder, angular type, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed. |
| 25 | Switch piano, flush type, single pole, one way, 5/ 6 Amps, complete all as specified and as directed. |
| 26 | Switch piano, flush type, single pole, one way, 15/ 16 Amps, complete all as specified and as directed. |
| 27 | Socket outlet, 2-in-1, 3-pin, 5/ 6 and 15/ 16 Amps, combined, flush type, complete all as specified and as directed. |
| 28 | Socket outlet, 2-in-1, 3-pin, 5/ 6, flush type, complete all as specified and as directed. |
| 29 | Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, size 65mmx25mm dia, complete all as specified and as directed. |
| 30 | Replacement of old unserviceable sub main wiring with new sub main wiring in PVC conduit of required size as per site for circuits/ submain wiring along with earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, using colour coding, drawn in and including any type of conduit, any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed.Note: Cost of all three run of wire and one run of conduit of required size will be included in quoted rate. |
| 31 | Sheet metal enclosures for Triple Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-65, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, fixing in repairs, complete all as specified and as directed. |
| 32 | Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-65, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, fixing in repairs, complete all as specified and as directed. |
| 33 | MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 34 | MCB, double pole, 32 Amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 35 | MCB, Four pole, 40 Amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 36 | Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron wire, size 4.0mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. |
| 37 | MCB, Four pole, 63 Amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 38 | Electronic stepped type electronic fan regulator flush type on the existing board along with other switches etc. as required, complete all as specified and as directed. |
| 39 | LED lights fitting wall surface mounted, 18 Watt, 220 Volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.Make: Havells cat part No-LUMILINEPLUSNEOBS18WLED830SPCSSIND or equivalent in Philips/ Bajaj/ Crompton. |
| 40 | LED street light fitting 35 Watt 230 Volt, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, and including house service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.Make: Havells cat part No- Superb Street Light 35 W 6500 K IP65 or equivalent in Phillips/ Bajaj/ Crompton. |
| 41 | Ceiling fan, having metallic, sweeps size 1200mm, 5-star rating, copper winded motor, including fixing arrangement, electric connection with twin core flexible wire of 1.50 Sqmm and flexible conduit pipe of suitable dia, complete all as specified and as directed.Make: Havells ordering code-FHCHM5SBRN48 or equivalent in Oreint/ Polar/ Usha. |
| 42 | LED lamp, capacity 9 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, fixing in repairs, complete all as specified and as directed.Make: Havells ordering code-LHLDDDBEBI2R009 and cat part No-LED ADORE PLUS 9 W B22 WW 2 STAR LAMP or equivalent in Philips/ Bajaj/ Crompton. |
| 43 | Amount of Schedule of credit as mentioned here-in-after shall be deducted from quoted amount. |