| 1 | Taking down Cement plaster on brick walls built in cement mortar including raking out joints,hacking for key, scrubbing down with water etc omplete all as specifiedand as directed. Engr-in-Charge . |
| 2 | M&L for 15 mm thick rendering in CM 1:4 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.by engr in charge, |
| 3 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paintover a coat of primer complete all as specifed as direted by Engr-in-charge. |
| 4 | M&L for complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescentsalts and treating oil and greasy spots as applicable and washing with water & applying two coat of cement based paintover one coat of primer complete all as specified and directed. |
| 5 | Demolation Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified . |
| 6 | M&L Brick work with subclass \"B\" bricks, straight or curved on plan exc 6m mean radius built in Cm 1:6 all as specified and directed. |
| 7 | Mechanically used water fitting Hydraulic pressure machine and water sucking hydraulic pressure machine jet press for cleaning of sewage line shall be used by the contractoras per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE. (Zone- B.) |
| 8 | M&L for cement concrete 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specifiedand as directed. |
| 9 | Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 10 | M&L for Cement concrete 1:3:6 typeC-2using 20mm graded stone agg as in foundations, filling and mass concrete complete all as specified and directed. |
| 11 | S&F Endura colours paving tiles 30cm X 30cm x 9-10mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6 all as specified and directed.make: Johnson |
| 12 | M&L Machine pressed precast concrete PU coated colourinterlocking paver block any shape and size, with grey cement and pigment confirming to IS 5658-2006 of 60 mm thicknessM-35 Gradecomplete all as specified and directed. |
| 13 | M&Lfor sand filling under floor or in foundations including watering and consolidation |
| 14 | Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt |
| 15 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 16 | Dismantling timber scantlings 40 Sqcm and over in section, in any position unframed work complete,all as specified anddirected . |
| 17 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed |
| 18 | M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified |
| 19 | Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. |
| 20 | M&L for 18-20 mm Granite (any type) work (table rubbed and polished) in steps,jambs,pillars window-cill,cooking platforms ,wall linning vetical face and incl 15mm thick screed bed using marble dust with admixturein CM (1:4) with pointing and white cement (1:2)of pigment to match with shade of granite all as spd. |
| 21 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 22 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor FRLS,drawn in and including rigid PVC conduit with conduit accessories concealed in wall/ceiling, medium grade ,ISI marked,terminal box of 1.6 mm thick including sheet cover/Modular cover plate of suitable module for fixing of switches/sockets and regulators etc. including provision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable green colour and connected to common earth dolly complete for the following :- |
| 23 | One light/fan/exhaust fan point controlled by oneway switch. |
| 24 | One bell/buzzer point controlled by one bell push |
| 25 | One light point controlled by two Nos two way switches |
| 26 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 27 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 28 | All as per item No 22 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge |
| 29 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet coverfor housing switches, socket out let and fan regulators etc, all as specified and as directed for the followings:- |
| 30 | One light/fan point controlled by oneway switch |
| 31 | One bell /buzzer point controlled by one bell push |
| 32 | One light point controlled by two Nos two way switches |
| 33 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 34 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 35 | All as per item No 24 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 36 | Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge. |
| 37 | Supply and fix white cover plate with frame 3 Module omplete all as specified and directed by Engineer in charge. |
| 38 | Supply and fix white cover plate with frame 4 Module omplete all as specified and directed by Engineer in charge. |
| 39 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 40 | M&Lin replacement switch modular type 6amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 41 | M&L in replacement Modular Bell pushbutton SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 42 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 43 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate 230V AC complete all as specified and directed by Engineer in charge. |
| 44 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 45 | M&L in replacement modular stepped type electronic fanregulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 46 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 47 | M&L in replacement switch piano flush button type single pole two way 6 Amps complete all as specified and directed by Engineer in charge. |
| 48 | M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge. |
| 49 | M&L in replacement switch piano flushbutton type single pole 16 Amps complete all as specified and directed by Engineer in charge. |
| 50 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 51 | M&L in replacement socket outlet6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 52 | M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. |
| 53 | M&L in replacement bell electric (dingdong) 230 volt, SPall complete all as specified and directed by Engineer in charge . |
| 54 | M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge. |
| 55 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge. |
| 56 | M&L in replacement sheet metalenclosure, single pole and neutralwith a two pin and earth plug and socket 240 Volts grade20Amps complete with onesingle poleMCB \"C\" series 10/20 A capacity complete all as specified and directed by Engineer in charge. |
| 57 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor > 0.90, THD< 10%, colour temperature-6500K, surge protection 2.5KV in CM, IP-20 protected, Class-1, short circuit and over circuit protection, voltage range-180 to 240 Volts AC, temperature range 0 to 50 Degree C andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting completeallas specified and directed. |
| 58 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD<10%, color temperature>6500 K, surge protection 2.5 KV in CM IP-20 protected meets LED IS specifications, voltage range-150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 59 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.90, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency>85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 60 | S&F in replacement of decorative type wall mounted luminaire (Comet)with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge . |
| 61 | Supply and fix surface ceiling mounted, LEDdown light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 70 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >70, Power Factor>0.90, Driverwithvoltage variation range-180 to 240 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 62 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge. |
| 63 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 64 | Supply and fix MCB DB SPN 12 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link completeall as directed by Engineer -in- Charge. |
| 65 | Supply and fixMCB DB SPN 8 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link completeall as directed by Engineer -in- Charge. |
| 66 | Supply and fixin repair MCB DP 63 Amps 240 volts 10 KA 50 HZ \"B\" curve complete all as specified and directed by Engineer in charge. |
| 67 | Supply and fixin repair MCB DP 40 Amps 240 volts 10 KA 50 HZ \"B\" curve complete all as specified and directed by Engineer in charge. |
| 68 | Supply and fixin repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"B\" curve complete all as specified and directed by Engineer in charge |
| 69 | Supply and fixing ventilating Fan250 mm sweep, 1200 RPM, non metallic resin body, single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 70 | Supply and fixingexhaust fan300 mm sweep (steel Body),1250 RPM, metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 71 | Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 72 | Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA, 4 pole, 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 73 | Supply & fix in repair factory made epoxy powder coated load line distribution board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing conforming to IS : 8623 complete all as specified. |
| 74 | S&F in replacement Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 75 | Supply and fix in replacement sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 76 | Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25mm dia non metalic rigid PVC conduit in walls all as specified and as directed. |
| 77 | Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25mm dia non metalic rigid PVC conduit in walls all as specified and as directed. |
| 78 | S&F plug top, 3 pin,20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge. |
| 79 | S&F socket 3 pin20 amp earth metal clad(ISImarked) complete all as specified and directed by Engineer in charge . |
| 80 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 81 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 82 | S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 83 | M & L forin replacement onlysingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 84 | M & Lin replacement foronlysingle core PVC insulated cable2.5Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 85 | M & Lin replacement foronlysingle core PVC insulated cable4Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 86 | M&L in replacement copper cable flexible 2 corePVC insulated of size 23/.0076 ll each roll should not be less than 90 mtr as specified and directed by Engr-in-Charge. |
| 87 | M&L for fan motor of ventilating fan 250/300mm sweep plastic body operated on single phase 230volts 50Hz electric supply as per sample complete including making necessary electrical connections and testing on site after replacement all as specified and directed by Engr-in-Charge at site. |
| 88 | S & F water heater storage type (Geyser) steel body vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warrant on product.Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating. |
| 89 | Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEEfive star rated voltage range 140 - 280 volts with brushess direct current motor (BLDC)all as specified and directed by Engr in Charge.(Against BLDC converson). Old fans shall be deposited to MES yard. |
| 90 | Supply and Fixing wall mounted angular Electric chimney black colour of suction power not less than not less than 1200Cum/Hr,Al casette with stainless steel outer layer ,touch control panel,3 speedmotor with 250 watt with decorative smart cooker hood SS and glass ,energy efficent Led light with digital display , including ducting not less than 12 feet as per site required complete all as specified and as directed by Engr-in-Charge. |
| 91 | M & Lin replacement foronlysingle core PVC insulated cable10Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 92 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60cm long with brass nuts and rubber washers complete all as specified and directed. |
| 93 | Supply only heating element of 2 KW for any type with nut bolt washercomplete all as directed. |
| 94 | Supply only replacement of capacitor 3.15 Mfd,240 V complete all as specified and directed. |
| 95 | S&F 35W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarieshould more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:65 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 170-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision ofsuitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 96 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge. |
| 97 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge. |
| 98 | S & F Gang box surface type heavy duty suitable for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 99 | S&F LED 2 X 2 ft backlite surface mounted fitting 36/40 Wattsnot less than 3600lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy>100 lm/W, CRI>70, color temperature >5700k, IP 20, Power factor<0.90, THD<10%, 25000 burning hours ,Ambient temperature 0 to 50 Deg C, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. |
| 100 | Schedule of Credit |