| 1 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation over areas n exc 1.5m deep and getting in soft/loose soil complete all as specified and as directed. |
| 3 | ,---ditto--- all as per item No. 2 above but depth exc 1.5m but not exc 3m complete all as specified and directed. |
| 4 | M&L for PCC 1:2:4, type B2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat with rough finished surfaces of concrete complete all as specified. |
| 6 | Use & waste of form work to sides of square, rectangular or polygon pillars, posts, struts, piers, columns and stanchions etc.and similar work with rough finished surface of concrete complete all as specified and directed. |
| 7 | Use & waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.and similar items with rough finished surface of concrete complete all as specified and directed. |
| 8 | Use and waste of formwork to sides and soffits of suspended slabs such as roof slab, floor slabs landing horizontal or sloppingand similar workks thikness n.exc 200mm including neccesarry sufficient supports etc for flat and rough finished surfaces of concrete etc complete all as specified and directed |
| 9 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for rough finished surfaces all as specified and directed. |
| 10 | M & L for RCC M-30 (Design Mix) (using 20mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and as directedNote : Reinforcement & formwork shall be measured and paid for separately. |
| 11 | M & L for RCC M-30 (Design Mix) (using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directedNote : Reinforcement & formwork shall be measured and paid for separately. |
| 12 | M&L for RCC M-30 (design mix) (using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts and the like complete all as specified and as directed.Note : Reinforcement & formwork shall be measured and paid for separately. |
| 13 | M & L for RCC M-30 (Design Mix) (using 20mm graded stone aggregate) as in slab supported on walls , beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.Note : Reinforcement & formwork shall be measured and paid for separately. |
| 14 | M&L Mild steel TMT bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed and specified. |
| 15 | ,--- ditto--- all as per srl item No. 14 above but TMT bar of 6 to 8mm dia complete all as directed and specified. |
| 16 | ,--- ditto--- all as per srl item No. 14 above but TMT bar of 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as directed and specified. |
| 17 | M&L for 100 mm thick PCC 1:4:8, type D-2(40mm graded aggregate) as in sub base finished and fair complete all as specified and as directed. |
| 18 | M&L hardcore of Broken stones or Boulders of gauge exc 63 mm but n exc 100mm, deposited spread and levelled in layers n exc 15 cm thick watered and rolled /rammed to a true surface complete all as specified and as directed. |
| 19 | M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over 15mm thick screed bed in CM 1:4 complete all as specified and directed |
| 20 | M&L for Rounding to edges of stones slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed. |
| 21 | M&L for creating grooves in granite slab as per site reqt complete all as specified and directed |
| 22 | M&L sand filling under floors or in foundations including watering, spreading and levelling in layers of 25 mm thick complete all as specified and as directed. |
| 23 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and as directed. |
| 24 | Removing excavated material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 25 | M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick masonry surfaces or concrete surface of wall finished even and fair including mixing of WPC as per manufacturers instruction complete all as specified and directed.Note : WPC shall be measured and paid seperately as supply only |
| 26 | M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick masonry surfaces or concrete surface of wall finished even and fair including mixing of WPC as per manufacturers instruction complete all as specified and directed.Note : WPC shall be measured and paid seperately as supply only |
| 27 | M&L rendering 10 mm thick in CM 1:3 as on concerete surface of ceilings finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | S&F 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors or fixed to walls etc with necessary fixing arrangements complete all as specified & directed. |
| 29 | M&L for brick work with sub-class \"B\" bricks (old size), straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 30 | M&L for firebrick work curved on plan exc 6m mean radius for fire places (other than in chimney shafts) set, jointed and pointed in fire clay complete all as specified and directed |
| 31 | M&L for cleaning the surface of roof slab top using wire brush and make it free from oil, grease, dust etc including cleaning with water complete all as specified and directed |
| 32 | M&L screed plaster 15mm thick in cement mortar (1:3) on concrete surfaces of roof to receive water proofing treatment finished even and fair incl mixing of WPC as per manufacturers instruction complete all as specified and directed.Noted : WPC shall be measured and paid seperately |
| 33 | Supply only integral water proofing compund ISI marked complete all as specified and directed. |
| 34 | M&L for applying fibre reinforced, single component, elastomeric liquid applied water proofing membrane in white colour,Excellent in UV having Solar Reflective Indexmore than 105, with PU hybrid polymers and reinforcing acrylic fibers, % elongation greater than 300 and applied in two layers including filling of cracks by crack seal complete all as specified and directed as follows :- (a) Surface shall be cleaned and moist that no loose particle is left on surface then apply first coat of liquid water proofinfg as a primer on the surface diluting as per manufacture instruction and allow the surface to dry for min 10-12 Hr time period. (b) Apply Second coat of Liquid water proofing without dilution on the primed surface and allow time to dry the surface for min 10-12 hr. (c) Apply Third coat of liquid water proofing without dilution over the second coat and Allow minimum 48 hours before subjecting the painted surface to service.Make:- Berger-HS Roof Kool & Seal, STP-ShaliUrethane® BTD Plus, Asian-SmartCare Damp Proof Ultra) |
| 35 | M&L for preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 36 | M&L pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws /J hook, L-type crancked hook complete all as specified and directed |
| 37 | S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways;drainage crossings, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed |
| 38 | M&L preparation of newly plastered surfaces of ceiling & applying two coat of white wash on ceiling complete all as specified and directed. |
| 39 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer over 1mm thick wall care putty complete all as specified & as directed. |
| 40 | M&L preparation of newly plastered surfaces of wall & applying applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of approved shade/tint complete all as specified & as directed. |
| 41 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth, for foundation etc or for shafts, wells n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in Soft/loose soil complete all as specified and directed. |
| 42 | M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 43 | M & L rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, with grey cement and coloured pigment laid over 25mm thick sand cushion layer complete all as specified and as directed.Note : Sand cushion shall be measured and paid seperately |
| 44 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 45 | M&L preparation of new concrete/ brick/stone surfaces of any description over 10cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of priming paint as in colour code directed by EIC complete all as specified and as directed. |
| 46 | M&L sand filling under floors or in foundations including watering, spreading and levelling in layers of 25 mm thick complete all as specified and as directed. |
| 47 | Supply, laying, jointing and testing 50mm bore galvanised steel tubes \"medium grade \"(ISI marked)with all necessary fitting (ISI marked) laid in trenches, floors and under roads complete all as specified and directed . |
| 48 | M&L for cutting, threading, drilling hole in existing CI/GI pipe line of size up to 80mm and making arrangement for tapping water connections complete incl GI socket, clamp, nipple and all other accessories reqd and making leak proof connection complete all as specified and directed. |
| 49 | S&F submersible horizontal openwell motor with pump of 5 HP, 3 phase, 20mtr head, discharge 10 to 22 LPS complete with 4sqmm, 3 core flat cable and cable connected from motor to starter, delivery pipe will be connected to main supply line complete all as specified and directed. |
| 50 | M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8m below normal ground level connected to and including galvanised iron or steel earth strip 32X6 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole/ test point.Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive ofexcavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed.Note 1 - following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labourfor connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 51 | Supply, installation, testing and commissioning of factory made powder coated, CPRI approved outdoor canopy type LT panel, fabricated out of min 3.15mm thick CRCA sheet suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit withstand capacity, IP 54 protection, fabricate in compartmentalized design totally enclosed, dust, weather & vermin proof with heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The copper bus bar RYBN having capacity 1.5 times of main incomer MCCBs. The panel board shall be mounted 60cm above ground level onform work of MS channel of section not less than 75mm X 40mm X 5mm thick grouted in PCC platfor. the sides of form work shall be covered with 3.15mm thick MS sheet complete, entire panel shall have a common copper earth bar of size 25mm X 5mm at the rear with 2 Nos earth stud, solid connection from main busbar to switchgeras with reqd size copper busbars and control wiring with minimum 1.5sqmm pvc insulated copper conductor cable, cable alleys, cable gland plates incl digital multi functional meter to measure voltage, current, PF comprising of the following :-(i) MCCB 100 Amps, 4 pole, 25 KA, AC, 415 Volts - 01 No (Incoming)(ii) MCCB 40 Amps, 4 pole, 16 KA, AC, 415 Volts - 01 No(iii)MCCB 25 Amps, 4 pole, 16 KA, AC, 415 Volts - 04 No(iii) MCB SPN 25 Amps, C curve, 10KA - 04 No(ii) Digital ammeter 0 to 300 amp with inbuilt selector switch and suitable No of CTs 200/5 amp - 01 Set(iii) Digital voltmeter 0 -500 volts 3 phase accuracy class 1 with inbuilt selector switch - 01 No(iv) LED indicating lamp RYB with backup protection rewireable fuse (Set of Three) - 01 Set(v) Soft starter of 5HP motor of make - LK model XD2000-09P3-4B1221 or equivalent in C&S / schinedier/ ABB - 02Nos |
| 52 | M & L Sand cushioning to under ground cable with screened and washed sand (non cohessive), 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge.Note : Punned thickness shall be considered for payment purpose. |
| 53 | Supply and laying factory made unreinforced pre-cast concrete cable protection cover LV class, type-I, flat of size 250mm X 150mm X 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection laid on the top of the sand cushioning complete all as specified and directed. |
| 54 | S&F steel tubular swaged pole complete with cast iron base plate, finial taper plug, bracket with clips, bolts, nuts & screws and one coat of red oxide primer, two coats of aluminium synthetic paint and alternate layer of yellow and white paint strip of 20cmabove 1m from ground as specified type 410 SP-22 (9m long) complete all as specified and directed. |
| 55 | S&F polycarbonate junction box of min size 300 X 200 X 105mm, IP 65 protection, rustproof, weatherproof, shockproof consisting of 01 No. 50A, 4 pole connector and 01 No 10Amp single pole MCB and fixing on the pole incl necessary fixing arrangement complete all as specified and directed by Engineer-in-Charge. |
| 56 | M&L PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 57 | Supply, laying, jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC sheathed, galvanised steel strips or wire armoured, heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade cross sectional area 35sqmm, 3.5core confirming to IS:7098 (part-I), laid in trenches, ducts, pipes or fixed on poles or walls including all necessary clamps, nut, bolt, washers, saddle etc complete all as specfied and directed.Note : The cost of AI thimbles / lugs and cable gland etc is included in quoted rates. |
| 58 | Supply, laying, jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC sheathed, galvanised steel strips or wire armoured, heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade cross sectional area 10sqmm, 3core confirming to IS:7098 (part-I), laid in trenches, ducts, pipes or fixed on poles or walls including all necessary clamps, nut, bolt, washers, saddle etc complete all as specfied and directed.Note : The cost of AI thimbles / lugs and cable gland etc is included in quoted rates. |
| 59 | S & F LED building street light fitting 45 watt 230V AC outdoor type comprising of pre wired driver, pressure die cast powder coated aluminium housing heat resistant glass, impact and corrosion resistance incl thermal management in multiple optics, clear acrylic cover and accessories with IP 65/66 protection complete all as specified and directed by Engineer-in-charge |
| 60 | S&F 2.5 Sqmm 3 core copper conductor cable, PVC insulated and PVC round sheathed, copper conductor (flexible), 1100 volt, confirming to IS : 694 including connecting the cable from street light to junction boxpassing through pole with and incl proper lugs and taking down of old unsv cable complete all as specified and directed.Note- (i) Cable is reqd to be connected from street light to junction box with and incl proper lugs. (ii) Cable will be fixed from inside of pole. |
| 61 | S & F 80 mm bore GI tubing \"light grade\" with all fittings, fixed to wall/ pole with suitable size MS clamp, nut, bolt, washer etc or laid under road crossing etc as reqd for protection of cable incl painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.Note : Cost of MS clamp, nut bolt, washer and GI fittings etc shall be inclusive in the quoted rates. |