Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" PART-I [B/R Works]:Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] including mangalore tiles in flooring, roof, apron of any description and removing rubbish / debris to a distance exc 1.5 Km but not exc 5.0 Km complete all as specified and as directed. |
| 2 | M & L for 25mm thick, PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate as in sub base of floors / levelling course for tiling and finishing the surfaces complete all as specified and directed. |
| 3 | M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick of Premium quality area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:4 icomplete all as specified and directed.Notes: [a] The colour/ shade/ design of tiles shall be as approved by GE.[b] The tile joint shall be kept as 3mm using tile spacers and masking tape shall be provided before applying of the epoxy grout and the surplus grout materials shall be thoroughly cleaned immediately. |
| 4 | M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick of Premium quality area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:4 icomplete all as specified and directed.Notes: [a] The colour/ shade/ design of tiles shall be as approved by GE.[b] The tile joint shall be kept as 3mm using tile spacers and masking tape shall be provided before applying of the epoxy grout and the surplus grout materials shall be thoroughly cleaned immediately. |
| 5 | M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick of Premium quality area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in vertical surfaces such as skirtings, dados and risers of steps, etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles laid over and including 10mm thick backing coat in CM 1:3 complete all as specified and directed.Notes: [a] The colour/ shade/ design of tiles shall be as approved by GE. |
| 6 | M & L for coloured joint free Glazed Ceramic tiles 7 to 8 mm thick of Premium quality, Edge cut, Concept type of isze 300mm x 450mm, as in vertical surfaces such as skirtings, dados, etc. set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of tiles laid over and including 10mm thick backing coat in CM 1:3 complete all as specified and directed.Notes: [a] The colour/ shade/ design of tiles shall be as approved by GE. |
| 7 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc including removing rubbish / debris to a distance exc 1.5 Km but not exc 5.0 Km complete all as specified and as directed. |
| 8 | M & L for 18mm to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20mm thick screed bed or bedding layer in Cement Mortar 1:6 complete all as specified and directed. [Notes: [a] Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. [b] The edges of treads shall be bull nosed / half rounded.[c] The edges of the treads and landings shall also be provided with three numbers of grooves. |
| 9 | M & L for Machine cut kota stone slab flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 10 | M & L for Machine cut kota stone slab 20-25mm thick as in vertical surfaces such as skirtings, dados, etc. set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of tiles laid over and including 15mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 11 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, andother similar situations complete alla s directed |
| 12 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thickin cement mortar 1:4 on concrete surfaces finished even and smooth without using extra cement duly mixed with and including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth and laying Attatic Propelene Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight notless than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion over oil based bituminous primer @ 0.50 Kg/Sqm complete including taking down existing Roof Treatment of any description and rremoval of debris out side MD land complete all as specified and directed by the Engineer-in-Charge |
| 13 | M&L for providing roof cooling ceramic tiles of size 300 x 300 mm, 7 to 8 mm thick, SRI value more than 90 conforming to IS 15622, set and jointed in cement slurry and pointed flush with high performance polymer modified cementitious non slip tile adhesive and the grout shall be thoroughly cleaned immediately including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. [Notes: The colour/ shade/ design of tiles shall be as approved by GE.] |
| 14 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed. |
| 15 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed. |
| 16 | S & F factory made single rebated Wood Polymer Composite [WPC] solid door/ window / ceosetory windows & other Frames/ Chowkhats of size 65mm x 125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as specied and as directed. |
| 17 | S & F factory made single rebated Wood Polymer Composite [WPC] solid door/ window / ceosetory windows & other Frames/ Chowkhats of size 65mm x 100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as specied and as directed. |
| 18 | S & F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class \"A\" category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge. |
| 19 | S & F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class \"A\" category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge. |
| 20 | S & F35mm thick, factory made Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., without sash, edges of framing plain, chamfered or round ed, fitted with cut beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I and fitted to Chowkats complete all as specified and as directed. |
| 21 | M & L for 18 mm thick factory made ready to install, non toxic, lead & cadmium free, single extruded, water proof, fire retardent and with excellent screw holding capacity , solid WPC board, one side decorative choice lamination and other side balancing white as in cupboard shutter, fixed to door frame with stainless steel screws including liping the cut edges with same material finish including dismantling old boarding with frmae of any description complete all asspecified and directed. |
| 22 | M & L for 18 mm thick factory made ready to install, non toxic, lead & cadmium free, single extruded, water proof, fire retardent and with excellent screw holding capacity , solid WPC board, one side decorative choice lamination and other side balancing white as in cupboard Shelve, fixed to and including WPC guide rail and stainless steel screws including liping the cut edges with same material finish including dismantling old boarding with frmae of any description complete all asspecified and directed. |
| 23 | M & L for factory made ready to install, non toxic, lead & cadmium free, single extruded, 3 side prelam, solid (non hollow), WPC door frame of size 75mm x 50mm and having water proof, fire retardent, termite proof with excellent screw holding capacity, mitred cut at two corners and joined with MS screws on each side and fixed to the existing wall using (10x100mm) long MS screws through the frame by using WPC fasteners, minimum 4 Nos MS screws to be provided for each vertical post and minimum 02 Nos MS screws to be provided on horizontal members complete all as specied and as directed. |
| 24 | S & F Magnetic catch with striking plate, 40mm size superior quality for cup board shutters complete all as directed |
| 25 | S & F stainless steel 304 grade \"O\" crank / Outer cabinet Auto Soft close hinges for cupboard shutters with 8mm spring for good pull complete all as directed |
| 26 | S & F Hasp and staple, safety type 100mm size aluminium anodised, including bolt to hinge plate and fixed with screws complete all as directed |
| 27 | M & L for Powder coated aluminium sections of approved colour for doors, windows, ventilators, partitions with frames and shutters fully or partly glazed, sliding / openable with extruded aluminium sections not less than 1.5mm thick and powder coating not less than 60 micron thick including necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, aluminium butt hinges, tower bolts, SS friction hinges, locking arrangement, etc complete all as specified and directed:-Notes:[a] The size of aluminium sections shall confirm to Designation 63400 all shall be as specified in relevant IS Code and as specified in MES Schedule Part-I, 2009.[b] S & F of Panel inserts such as Glass / Particle board / Gauze shall be measured and paid seperately.[c] Weight of aluminium sections shall only be accounted for payment purpose. Cost of aluminium fittings such as handles, hinges, tower bolts, etc is deemed to be included in the quoted rate. [d] The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, aluminium snap beading, screws, aluminium fittings, locking arrangement, etc complete |
| 28 | S & F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane fixed in aluminium door, windows and ventilators complete all as specified and directed. |
| 29 | S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed. |
| 30 | S & F anodised aluminium grill (anodised transperant or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing window frame with CP brass / stainless ateel screws @ 200mm c/c including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as directed by the Engineer-in-Charge. |
| 31 | S & F Stainless steel Butt hinges, 100mm size medium weight complete all as specified and directed. |
| 32 | S & F extruded aluminium alloy handles fabricated type anodised of size 150mm complete all as directed. |
| 33 | S & F extruded aluminium alloy handles fabricated type anodised of size 100mm complete all as directed. |
| 34 | S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed. |
| 35 | S & F floor door stopper of aluminium body and tongue anodised with hand drawn steel spring fixed in flooroverall length of cover plate 150mmcomplete all as specified and as directed. |
| 36 | S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as directed. |
| 37 | S & F 300mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as directed |
| 38 | S & F in repairs Chromium plated cast copper alloy, mixer valve for Hot and Cold water connections with an arrangement for shower and one tap complete all as directed. [Make shall be JAQUAR of model No. KUP35117 or its equivalent] |
| 39 | S & F in repairs 15mm dia fancy type, CP Stop valve, screwed down, high pressure, with crutch or butterfly handle, concealed type with long shank and cup screwed both ends for iron pipe or for unions and fixed complete all as directed. |
| 40 | S & F in repairs 15mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. [Make shall be Jaquar of Cat Part No. KUP-35053PM or its equivalent] |
| 41 | S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as directed. [Make shall be JAQUAR of Cat No. CON-011 KN or its equivalent] |
| 42 | S & F in repairs 15mm bore fancy type Chromium plated two way bib taps, screwed down for iron pipe or for brass ferrule with flanges complete all as specified and directed. [Make shall be Jaquar of Cat Part No. OPP-15041PM or its equivalent] |
| 43 | S & F in repairs Stainless steel kitchen plate rack of size 600x900x250mm made of 1.5mm thick (SS-304) stainless steel sheet complete all as directed |
| 44 | S & F in repairs 15mm bore bib tap fancy type Chromium plated capstan head, screwed down, screwed for 15mm dia bore iron pipe complete all as specified and directed. [Make shall be Jaquar of Cat Part No. ACN-CHR-5041N or its equivalent] |
| 45 | S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern] of size 560x440x395mm or nearest size, White, including flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMTcheck nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and \"P\" or \"S\" trap including 10 Ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 46 | S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550mm X 400mm, 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed. |
| 47 | S & F in repairs Health faucet, (ABS Body) with 8mm dia, 1.2m long Spirochrome flex & wall Hook complete all as directed. [Make shall be Jaquar of Cat No. ALD-CHR-577 or its equivalent] |
| 48 | S & F in repairs bevelled edge looking mirror of selected quality glass, of size 600 x 450 x 5.5mm thick fixed with chromium plated brass screws and cup washers complete all as specified and directed. |
| 49 | S & F in repairs Sink with drainage board made of stainless steel 1 mm thick (SS-304) kitchen or laboratorywith plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or includingfixingcantilever brackets and connecting union to pipe overall size 915 mm x 460 mmbowl size 410 mmx 330 mm x 160 mm complete all specified and directed |
| 50 | S & F in repairs Towel Rack 600mm long without lower hanger complete all as directed. [Make shall be Jaquar of Cat No. AKP-35781P or its equivalent] |
| 51 | S & F in repairs Towel Ring square with round flange complete all as directed. [Make shall be Jaquar of Cat No. ACN-1121N or its equivalent] |
| 52 | S & F Corner Glass shelf of size 300mm with chromium plated support brackets complete as directed by Engineer-in-Charge. [Make shall be Jaquar of Cat No. ACN-CHR-1173 or its equivalent] |
| 53 | S & F transparent Glass shelf of size 600mm long with chromium plated support brackets complete as directed by Engineer-in-Charge. [Make shall be Jaquar of Cat No. AKP-CHR-35771P or its equivalent] |
| 54 | S & F in repairs Brass Chromium plated shower rose 125mm with or without swivel joints, including fixing to steel pipe or union complete all as directed |
| 55 | S & F 110mm stainless steel Floor Trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 56 | S & F 75mm stainless steel Floor Trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 57 | S & F in repairs Decorative type Stainless Steel Curtain Rod of 25 mm dia including PVC rings @ 100 mm centre to centre with suitable decorative type SS globe type brackets to match with curtain rod complete all as specified and as directed. |
| 58 | S & F 75mm outlet PVC [SWR] Floor Trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 59 | S & F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litres capacity, triple layered, hoisted and fixed in position including provision of25mm dia PTMT ball valve, spouts of suitable size for connecting inlet, outlet, over flow and washout pipes including taking down old tank complete all as specified and directed. |
| 60 | M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in plinth protection and providing necessary joints 12mm wide to the full depth of concrete at every 3m intervals and every change of directioons and the joints duly filled with mastic filling comprising of one part of heated bitumen blown grade any penetration and three parts of sand (all be weight) and finishing the surfaces even and smooth without using extra cement including demolition of existing concrete complete all as specified and directed. |
| 61 | M & L for providing Precast RCC 1:1.5:3, Type A-1, using 20mm graded stone aggregate as in Fins, facias, louvers, chajjas, cooking platform, shelves, parapets and railings exc 60cm in height and the like including demolition of existing concrete complete all as specified and as directed. |
| 62 | M & L for providing Precast RCC 1:1.5:3, Type A-1, using 20mm graded stone aggregate as in columns, pillars, posts, piers and struts, etc including demolition of existing concrete complete all as specified and as directed. |
| 63 | M & L for providing Precast RCC 1:1.5:3, Type A-1, using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, etc and in shelves including demolition of existing concrete complete all as specified and as directed. |
| 64 | Use and waste of steel formwork to Fins, facias, louvers, chajjas, cooking platform, shelves, parapets, railings and similar work for fair finished surfaces of concrete flat complete all as specified and directed. |
| 65 | Use and waste of steel formwork to sides of pillars, posts, columns and similar work for fair finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed. |
| 66 | Use and waste of steel formwork to soffits of suspended slabs fair finished surfaces of concrete flat complete all as specified and directed. |
| 67 | M & L for High Strength Corrosion Resistant Deformed TMT Bars of 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 68 | M & L for High Strength Corrosion Resistant Deformed TMT Bars of 6 to 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 69 | M & L for High Strength Corrosion Resistant Deformed TMT Bars of 6 to 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded as in stirrups, spacers and binders, etc complete all as specified and as directed. |
| 70 | M & L for providing and injecting emulsion for post construction anti-termite treatment under existing floors using emulsion CHLOROPHYRIFOS 20 EC at 1% concentration at the rate of one litre per each hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floor complete all as specified and directed by Engineer-in-Charge. |
| 71 | M & L for providing and injecting chemical emulsion for post construction anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at 2.25 litres per linear running metre including drilling and plugging holes with cement mortar (1:2) to match with the existing surface complete all as specified and directed by Engineer-in-Charge. |
| 72 | M & L for providing and injecting chemical emulsion for post construction anti-termite treatment at points of contact of wood work by chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at the rate of 0.5 litre per each hole by drilling 6mm dia holes at a downward angle of 45 Degree at 150mm centre to centre complete all as specified and directed by Engineer-in-Charge. |
| 73 | Supplying and fixing of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed in walls / ceiling or laying in floors including taking down old GI tubing of 20mm dia complete all as specified and directed. [Note: Quoted rate is deemed to include for cutting chases, pinning in. making good to facings and pointing in cement mortar 1:3 wherever required as per site condition] |
| 74 | Supplying and fixing of 25mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed in walls / ceiling or laying in floors including taking down old GI tubing of 25/32mm dia complete all as specified and directed. [Note: Quoted rate is deemed to include for cutting chases, pinning in. making good to facings and pointing in cement mortar 1:3 wherever required as per site condition] |
| 75 | S & F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls/ceiling including taking down old eaves gutters / SWR pipe with fittings complete all as specified and directed. |
| 76 | S & F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls/ceiling including taking down old eaves gutters / SWR pipe with fittings complete all as specified and directed. |
| 77 | M & L for 110mm bore PVC (SWR) bends any radius with access door including jointing with solvent cement complete all as specified. |
| 78 | M & L for 110mm bore PVC (SWR) bends any radius including jointing with solvent cement complete all as specified. |
| 79 | M & L for 75mm bore PVC (SWR) bends any radius with access door including jointing with solvent cement complete all as specified. |
| 80 | M & L for 110mm bore PVC (SWR) branch piece double, (Double Y) equal or unequal with access door including jointing with solvent cement complete all as specified. |
| 81 | M & L for 75mm bore PVC (SWR) branch piece double, (Double Y) equal or unequal with access door including jointing with solvent cement complete all as specified. |
| 82 | M & L for 110mm bore PVC (SWR) Vent cowl including jointing with solvent cement complete all as specified. |
| 83 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precastconcrete articles complete all as directed |
| 84 | M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks complete all as specified and directed. |
| 85 | M & L for brick work in half brick thick walls using fly ash straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 8mm dia bars at every fourth course of brick work complete all as specified and directed. |
| 86 | Taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed. |
| 87 | M & L for rendering in two layers comprises of 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished with 5mm thick in CM 1:4 duly mixed with and including cement water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement complete all as specified and directed. |
| 88 | M & L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed. |
| 89 | M & L for rendering 5mm thick in CM 1:3 on fair faces of ceiling / Chajja surfaces, finished even and smooth with out using extra cement complete all as specified and directed. |
| 90 | Dismantling mild steel structural steel work of any description from any position complete all as specified and as directed |
| 91 | M & L for preparation of old decorated surfaces of ceiling by brooming down, brushing and applying One coat of white wash complete all as spcified and directed. |
| 92 | M & L for preparation of old decorated surfaces of Walls by brooming down, brushing and applying One coat of white wash complete all as spcified and directed. |
| 93 | M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directetd. |
| 94 | M & L for preparation of newly plastered surfaces of Walls and applying three coats of white wash complete all as specified and directetd. |
| 95 | M & L complete removal of existing treatment of any description on wall surfaces by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces over Cement based Wall Care Putty of suitable thickness by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfacescomplete all as specified and as directed.(Note: The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 96 | M & L for newly plastered surfaces of wall surfaces by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces over Cement based Wall Care Putty of suitable thickness by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfacescomplete all as specified and as directed.(Note: The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval.) |
| 97 | M & L for complete removal of existing treatment on old decorated surfaces and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as directed. (Note: The contractor shall carryout Painting work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out the work through their authorised applicatorsbefore commencement of the work to GE for approval.) |
| 98 | M & L for preparation of newly plastered surfaces of walls/ceiling and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as directed. (Note: The contractor shall carryout Painting work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out the work through their authorised applicatorsbefore commencement of the work to GE for approval.) |
| 99 | M & L complete removal of existing treatment of any description on ceiling surfaces by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer complete all as specified and as directed.(Note: The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 100 | M & L for newly plastered surfaces of ceiling surfaces by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer complete all as specified and as directed.(Note: The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval.) |
| 101 | M & L for preparation old decorated wall surfaces of any description by using vaccume based sanding machine with 1500-2700 RPM with internal dust extraction system for a clean environment as certified by the manufacturer of paint, and applying injection sealer by providing holes of 6mm dia and 50mm deep at an angle of 450 and apply a coat of advanced damp proof protective wall sealer and applying suitable thickness of water proof putty to form a smooth surface and then applying two coats of Acrylic Washable Distemper over one coat of alkali resistant primer complete all as specified and as directed.(Note: The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 102 | M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed. |
| 103 | M & L for preparation of old painted steel surfaces of any description, not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as directed. |
| 104 | M & L for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint complete all as specified |
| 105 | M & L for Writing Stops, commas, short lines, dashes, hyphens, brackets, etc. with synthetic enamel paint complete all as specified |
| 106 | S & F Aluminium anodised snap grid frame Work for false ceiling of size 600x600mm including fixing Gypsum board of 12mm thick conforming to IS – 2095, fixed with screws as per manufacturers instructions, including 6 mm dia GI hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including applying Two Coats of Acrylic Washable Distemper over a coat of Alkali Resistant Primer over suitable thickness of putty complete all as specified and as directed. |
| 107 | M & L for providing Two components acrylic polymer cementitious elastomeric water proof coating, minimum 1.5mm thick [DFT] with nominal coverage of 2.2 Kg/Sqm including thourough preparation of surfaces by mechanical means to obtain a plain and level surface including sprinkling of clean and washed sand on final coat when wet complete all as per manufacturers instructions and as directed by Engr-in-charge. Notes:[a] The coating shall have minimum 1 N/Sqmm tensile strength, elongation of a minimum 80% when tested as per ASTM D 412, resisting 5 bar hydrostatic presuure as per DIN 1048 and having crack bridging ability of upto 2mm.[b] The coating shall cover all the wet areas of floor and the vertical walls for a height of minimum 4 feet above the floor.[c] The rate quoted shall be deemed to include for the following:- [i] Filling of all cracks crevices with approved epoxy based mortar and made good to receive waterproofing coating treatment. [ii] Providing additional coat reinforced with a fibre band sandwiched between 1st and2nd coat along the periphery of the toilet floors, around protrusions and around pipes. |
| 108 | M & L for filling Polymer modified non shrinking slurry with CEBEX 100 of Fosroc or equivalent chemical for sunken floors for toilets by drilling holes to a depth of 60mm and 20mm dia at 1m interval and applying 2mm thick brush bond over the concrete surfaces by mixing acrylic emulsion NITO BOND BB of Fosroc or equivalent with brush bond powder and water and testing the same for 48 hours with complete filling within the sunken floor as per manufacturers technical specifications complete all as directed. |
| 109 | M & L for surface prepartion on concrete shall be free from dust, loose materials, surface contamination and materials which reduce bond or prevent suction or wettting by repair materials. Delaminated, weak, damaged and deteriorated concrete adhere necessary sound concrete shall be removed by suitable means. Substrate shall be saturated surface dry (SSD) with no standing water. Rusting, scales, motor concrete, dust and other loose materials on Steel reinforcement shall be removed by blast cleaning or other means of mechanical abrasion and the reinforcement shall be fully exposed and then apply a single coat of Alkaline rust converting primer on alround the reinforcement bars and two coats of Epoxy phenolic anti corrosive protective coat on bars alround complete all as directed. [Anticorrosive treatment shall be continuous especially in the regions where pitting, imperfections, etc were present on the surface of the bars.] |
| 110 | M & L for providing Micro concreting M-40 grade as specified below:-[a] Dry the substrate surface and clean it free of debris and dust.[b] Apply epoxy bond coat on the sound sub strate using approved spary machine & ensuring that no pin holes are visible (in case pin hole are still visible, a second coat shall be applied to ensure absence of pin holes.[c] Immediately after application of epoxy bond coat as above,pour Micro concrete M-40 grade using approved mixing machines / pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns, etc. Adding of aggregates will be permitted only as per manufacturers recommendations without compromising the strength. [Note: Quoted rate deemed to include for cost of form work as required at site in addition to micro concrete and epoxy bond coat] |
| 111 | M & L for providing the Polymer modified cementitious mortar [PMM] as specified below:-[a] Dry the substrate surface and clean it free of debris and dust.[b] Apply epoxy bond coat on the sound sub strate using approved spary machine & ensuring that no pin holes are visible (in case pin hole are still visible, a second coat shall be applied to ensure absence of pin holes.[c] Immediately after application of epoxy bond coat as above apply Polymer modified cementitious mortar [PMM] of 30mm thickness. Application of PMM shall be preferably be in coats of approximately 10mm thickness.[d] PMM work shall be executed in fairly rapid successions so as entire work is completed within 30 minutes.[e] PMM surface to be moist cured for three days followed by air cutting in temperature as recommended by manufacturers. |
| 112 | M & L for providing the Polymer modified cementitious mortar [PMM] as specified below:-[a] Dry the substrate surface and clean it free of debris and dust.[b] Apply epoxy bond coat on the sound sub strate using approved spary machine & ensuring that no pin holes are visible (in case pin hole are still visible, a second coat shall be applied to ensure absence of pin holes.[c] Immediately after application of epoxy bond coat as above apply Polymer modified cementitious mortar [PMM] of 40mm thickness. Application of PMM shall be preferably be in coats of approximately 10mm thickness.[d] PMM work shall be executed in fairly rapid successions so as entire work is completed within 30 minutes.[e] PMM surface to be moist cured for three days followed by air cutting in temperature as recommended by manufacturers. |
| 113 | M & L for Drilling into the sound RCC members for anchoring of rebars / stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling for 8mm dia bar for drilling length of 80mm to 100mm complete all as directed by the Engineer-in-Charge. [Anchoring of new re-bars of any dia as directed in to the sound RCC members using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent) with appropriate dia of drilling holes as mentioned above for proper bonding into the concrete etc, complete all as directed [The cost of drilling hole & chemical anchoring with epoxy resin and welding in repairs exc 2.5cm but not exc 5cm length is included in this item] |
| 114 | Impregnating cream for injection into masonry or concrete wall 230mm thick against capillary rising humidity. Rising bar super strong (Product No. 201) of chowgale building chemicals or equivalent of pidilite / Dr fixit/Sika all as specified and directed by the Engineer-in-Charge by adopting following methodology:-[a] The surface must be sound, absorbent, clean, free of dust, oil, paint, curing agents, loose cement or lime plaster & concrete, debris or any seperation layers.[b] The plaster must be knocked off at least 50cm beyond the visibility penetrated area.[c] Damaged mortar joints are to be scraped out to a depth of approximately 2-3cm. All sharp edges / joints need to be levelled, loose concrete to be removed.[d] Drill boreholes of ground level horizontally into the masonry[e] The holes shall be drilled until a depth of approximately 5cm (for 6cm thick wall) before the end of the wall is reached. The boreholes shall be 12mm to 15mm dia and should be spaced at 100 to 120mm apart and the vertical offset is 6cm maximum.[f] Before inserting rising bar Super strong or equivalent the boreholes must be cleaned from boring dust by using air pressure. [g] For applying of rising bar Super strong or equivalent the dosing system inserted as far as possible into the borerhole. While dosing the product uniformly, the injection nozzle is pulled out leading to a completely filled borehole.[h] Treatment of highly absorbent masonry might require repeated filling of the borehole. Depending upon extent of damage, Rising Bar Super Strong or equivalent can be reinjected into the same hole after 24 hours. |
| 115 | S & F Rectangular polyethylene [HDPE] water storage tank, Lofttype 100 litres capacity, hoisted and fixed in position including provision of 25mm dia PTMT ball valve, spouts of suitable size for connecting inlet, outlet, over flow and washout pipes including taking down old tank complete all as specified and directed. |
| 116 | Material & Labour for providing and fixing stainless steel (Grade 316L) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling existing SS railing complete all as directed |
| 117 | M & L for 100mm thick, PCC 1:4:8, type D-2, using 40mm graded stone aggregate as in sub base of floors, hard standing including demolition of existing concrete complete all as specified and directed. |
| 118 | M & L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS: 15658-2006 of 60mm thick, M-35 Grade including providing 50mm thick sand filling including taking down existing paver blocks of any description and size complete all as specified and directed. |
| 119 | M & L for RCC 1:2:4, type B-1, using 20mm graded stone aggregate as in cast in lintels upto 1.5m span, copings, bed blocks for hold fasts, bed plates, roof kerbs and similar work including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed. |
| 120 | M & L for providing Precast RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 including demolition of existing concrete complete all as specified and directed. |
| 121 | M & L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concreteincluding demolition of existing concrete complete all as specified and directed. |
| 122 | M & L for PCC 1:3:6, type C-2 using 40mm graded stone aggregate as in surface channels and drains including demolition of existing concrete complete all as specified and directed. |
| 123 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc. Complete all as directed |
| 124 | M & L for PCC 1:3:6, type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concreteincluding demolition of existing concrete complete all as specified and directed. |
| 125 | M & L for Reinforced concrete pipes, 200mm bore, class NP3, laid and jointed complete with collars and all necessary fittings including demolition and breaking up of old drain pipes complete all as directed |
| 126 | M & L for Reinforced concrete pipes, 1500mm bore, class NP3, laid and jointed complete with collars and all necessary fittings including demolition and breaking up of old drain pipes complete all as directed |
| 127 | M & L for concrete bed to drain pipes of size 200mm bore packing under and haunching against the sides of pipes after they are laid and tested in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed. |
| 128 | M & L for concrete bed to drain pipes of size 150mm bore packing under and haunching against the sides of pipes after they are laid and tested in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed. |
| 129 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 200mm dia of pipe complete all as specified and as directed. |
| 130 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150mm dia of pipe complete all as specified and as directed. |
| 131 | SCHEDULE \"A\" PART-II [E/M Works]:M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area)1100V grade drawn through and including PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of flush type metal GI boxes with modular cover plates, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old point wiring with fixtures and fittings complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for cutting through wall, chasing, pinning in making good to the disturbed surfaces whrever required] |
| 132 | All as per item No. 131 above but suitable for one light point controlled by two 02 way switches |
| 133 | All as per item No. 131 above but suitable for one 5/6 Amps socket outlet point controlled by one switch on the same board |
| 134 | All as per item No. 131 above but suitable for one 5/6 Amps socket outlet point controlled by one switch on independent board |
| 135 | All as per item No. 131 above but point wiring with PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 2.5 Sqmm (nominal area) suitable for one 15 Amps power point on independent board complete all as specified and directed. |
| 136 | All as per item No. 131 above but point wiring with PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 4.0 Sqmm (nominal area) suitable for power point on independent board complete all as specified and directed. [For AC & Cooler points] |
| 137 | S & F TV Socket outlet with metal box |
| 138 | S & F modular switch single pole, 1 way, 6 Amps, 1 module |
| 139 | S & F modular switch single pole, 2 way, 6 Amps, 1 module |
| 140 | S & F modular bell push flush type 6 Amps, one way, 1 module |
| 141 | S & F modular switch 1 way, 16 Amps, 1 module single pole |
| 142 | S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module |
| 143 | S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module |
| 144 | S & F modular electronic fan regulator, socket type, 2 module complete all as specified and directed. |
| 145 | S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed |
| 146 | S & F Calling bell, ding dong AC, 230 Volts, single pole |
| 147 | S & F in repairs 4 module PVC SRCD with two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed. |
| 148 | M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 2.5 Sqmm, drawn through and including 20mm dia concealed PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 2.5 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.] |
| 149 | M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 6.0 Sqmm, drawn through and including 20mm dia concealed PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.] |
| 150 | S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wallcomplete all as specified and as directed. |
| 151 | S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wallcomplete all as specified and as directed. |
| 152 | S & F in repairs MCB, SPN, 32 Amps, 240 Volts, 10 KA, C series |
| 153 | S & F in repairs MCB, SP 6 to 32 Amps, 240 Volts, 10 KA, C series |
| 154 | S & F in repairs LED tube light fittings, retro bar professional WH 5700K to 6200K, 1x20 W of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge. |
| 155 | Taking existing LED tube light fitting of any type and capacity and refixing the same in new or same location with all accessories including prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge. |
| 156 | S & F in repairs LED tube light fittings, mirror type with high out put diffuser 2 feet long of 10 Watts of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge. |
| 157 | S & F in repairs Building Security light LED type of 35 Watts new generation energy saving & environmental friendly long life made up of Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 32mm dia GI light grade pipe of 1.5m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge. |
| 158 | Supply and fixing in repairs round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed |
| 159 | S & F in repairs LED bulb, 9 Watts, not less than 900 lumens, Luminous efficacy > 100 Lum/Watt, CCT: WW/NW/CW, CRI > 80 Ra including Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as directed |
| 160 | S & F in repairs stationary louvers for exhaust fans of 300mm sweep made out of powder coated aluminium anodised sheet of minimum 1mm thick with non removable blades fixed permanently at 450 angle for protection from rain including providing aluminium wire mesh forr bird protection complete all as directed |
| 161 | Taking down existing Ceiling Fan of any description and capacity from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning, greasing including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of suitable size, replacement of minor spares such as capacitor, canopy, cotter pin, rubber bushes, nuts & bolts, washers and spray painting with one coat of synthetic enamel paint of approved colour duly filling the cavities with filler complete all as specified and as directed. |
| 162 | Taking down existing Exhaust Fan of any description and capacity from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning, greasing including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of suitable size, replacement of minor spares and spray painting with one coat of synthetic enamel paint of approved colour duly filling the cavities with filler complete all as specified and as directed. |
| 163 | Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected with galvanised earth wire 4.0mm dia as earth lead by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including taking out old perished earth pits complete all as directed.[Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, RCC 1:2:4 type B-1 cover 40mm thick with 8mm dia steel reinforcement bars at 150mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m including taking down old earrthing sets complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.] |
| 164 | S & F in repairs 20mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Complete all as directed |
| 165 | M & L for repairs to Panel board indoor type of approximate size (5.0x1.5x1.5 feet) sheet metal parts tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover, etc with appropriate gauge MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all the nuts & bolts in MCBs and proper legging in cable and control wire sheet metal screws and painting the complete panel board with two coats of synthetic enamel paint over a coat of red oxide primer and marking the Qr No. of panel board in front side complete all as directed by the Engineer-in-Charge. |
| 166 | S & F empty box having dimensions 600mm(W)x600(H)x170mm(D) made of polycarbonate with IP-65 degree of protection (EN60529), dust proof, water tight, acid resistant, corrosion resistant insulated & shock proof, fire retardant, Self extinguishing, halogen & silica free non-toxic materia, UV resistant with internally embedded gasketfitted with required terminals should have to be type test certificate and verified by glow wire in accordance with IEC60695-2-11 suitable for mounting of 8 Nos of Single phase energy meter including all fixing arrangemnents complete all as directed. [Make shall be HENSEL of Cat No. Mi0800 or its equivalent as specified] |
| 167 | M & L for Overhauling of Geysers of 25 Lit capacity of any make by dismantling geyser by removing from its original position by disconnecting electric connection, inlet & outlet water supply connections, detecting the leakage by removing the copper vessel and rectifying by soldering, testing, refixing in position including spray painting with two coats of synthetic enamel paint over a coat of zinc chrome primer after filling cavities with filler and replacement of minor spares such as heating element, thermostat, Plug top, indication lamp, PVC connection for Hot & Cold water, etc complete all as directed |
| 168 | Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected with GI earth strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including taking out old perished earth pits complete all as directed.[Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, RCC 1:2:4 type B-1 cover 40mm thick with 8mm dia steel reinforcement bars at 150mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the electrode complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.] |
| 169 | S & F in repairs Aluminium strip 25 x 3.15mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed |
| 170 | Taking down and refixing Aluminium strip 25 x 3.15mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed |
| 171 | S & F in repairs GI strip of size 32x6mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed |
| 172 | S & F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 173 | Taking down existing Air termination, single pointed aluminium rod 12mm dia and 300mm long and refixing the same complete all as specified and directed. |
| 174 | S & F Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 Nos 25mm long hexagonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail