|
| 1 | Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) |
| 2 | Taking down shutters of any description not exc 2 Sqm each. |
| 3 | M&L Mild steel frame work as in door chowkhats with angle ironwelded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size,and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as spd. |
| 4 | S&F 35 mm thick 2nd class hard wood glazed and skelton shutter devided into square with plain, chamferred or rounded sash bar and fitted with cut and mitred beads for securing glass, size of members as per SSS Part - I section 8 clause 8.24 (b). |
| 5 | S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and non toxic additives ( max toxicityindex of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr incharge.Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. |
| 6 | S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed. |
| 7 | M&L aluminium alloy powder coated door including frame and channel of section (Door frame single grove 101.6mm x44.45 mm x2.1,shutter top section 47.62mm x44.45x1.95mm thick shutter bottem vertical section85 mm x44.45 mm x1.80mm yhick ,shutter middle section 83.50mm x 44.45 mm x1.80mm thick shutter glazing clips weighing not less than 0.097 kg/Rm as directed and approved by GE and as per IS specification including provn of 5.5mm thick tinted glass/12mm thick thick prelaminated particle board as required includingalu handle 150 mm ,tower bolt 150 mm,floor spring heavy duty \"SAMRAT\" ,looking arrangement \"GODREJ\" rubber gasket and door stopper complete all as specified and directed. |
| 8 | M&L aluminium alloy powder coated windows including aluminium coated frames, silding track frame and bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double revated and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter silding type with aluminium sectins as per series-A (15mm) 3 track of jindal section number for silding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrngement spring action and glazingclips joint cleats rubber gaskets etc inclding provision of 5.5 mm thick tinted frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed |
| 9 | S & F in repairmild steel framed work such as grillsn gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders freamed balusters, walk ways, railings, framework of watertanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165. |
| 10 | Cutting holes in Cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4complete,all as specified anddirected. |
| 11 | S&F aluminium bodyhydraulically Door closer regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as in repairscomplete,all as specified anddirected. |
| 12 | S&F MSbutt hinges medium weight 100 mm size fixed with MS screws. |
| 13 | S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws. |
| 14 | S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws. |
| 15 | S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut. |
| 16 | M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer |
| 17 | S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed. |
| 18 | Complete removal of existing treatment by scraping, rubbing , brooming down,washing with water etc of old decorated surfaces plastered or unplastered surface of wall and applying two coat of oil bond distemper over one coat of putty on wall complete all as spcefied and as directed by Engr-in-charge. |
| 19 | Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt |
| 20 | Dismantling timber scantlings 40 Sqcm and over in section, in any position unframed work complete,all as specified anddirected . |
| 21 | S & F in Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 22 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed |
| 23 | M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type and also taking down cement plaster on brick/concrete surfaces, including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed. Make: Asian Paints or equivalent in Sikka, Fosroc and STP Ltd.Note: The application shall be executed on any type of surface and on horizontal/Vertical areas. |
| 24 | M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile/fibre, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.Notes: For items ser No 23 & 24(1) The work shall be executed through authorised applicator of manufacturer only.(2) Authrised Applicator shall be approved by GE before starting of work.(3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Ten (10) years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor\"s dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer. |
| 25 | M & L for PCC 40 mm thick (Avg thickness) type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in roof complete all as specified and directed. |
| 26 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premiseof stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. |
| 27 | M & L for coloured non skid ceramic tiles of size 300x300x 7-8mm as in floors, set and jointed in neat cement slurryas per manufacturers instructions and pointed in white/ coloured cement, laid over and including cement screed bed 15mm thick in cement mortar 1:6, complete all as specified. |
| 28 | M & L for coloured ceremic tiles of size 600 x 600 x 9-10mm thick as in floor over 15mm thick screed bed 1:6 in cement mortar, set and jointed in white cement with pigment to match all as specified and directed. |
| 29 | M & L ceremic tiles coloured of size 600 x 100 mm x 9-10 mm thick on vertical surfaces as in skirting etc over 10mm thick backing coat in CM 1:4, set and jointed in white cement with pigment to match all as specified and directed. |
| 30 | M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed. |
| 31 | Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. |
| 32 | S&F Endura colours paving tiles 300mm X 300mm x 9-10mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6 all as specified and directed.make: Johnson |
| 33 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 34 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box/M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate/3 mm thick laminated top sheet coverfor housing switches , socket out let and fan regulators etc, all as specified and as directed for the followings:- |
| 35 | One light/fan point controlled by oneway switch |
| 36 | One bell/buzzer point controlled by one bell push |
| 37 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 38 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 39 | All as per item No 34 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 40 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall& including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover/Modular cover for terminal boxes also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following : |
| 41 | One light/fan point controlled by oneway switch |
| 42 | One bell/buzzer point controlled by one bell push |
| 43 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 44 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 45 | All as per item No 36 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge |
| 46 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 47 | M&Lin replacement switch modular type 6amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 48 | M&L in replacement Modular Bell pushbutton SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 49 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 50 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 51 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 52 | M&L in replacement modular stepped type electronic fanregulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 53 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 54 | M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge. |
| 55 | M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge. |
| 56 | M&L in replacement switch piano flushbutton type single pole 16 Amps complete all as specified and directed by Engineer in charge. |
| 57 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 58 | M&L in replacement socket outlet5 pin 6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 59 | M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. |
| 60 | M&L in replacement bell electric (dingdong) 230 volt, SPall complete all as specified and directed by Engineer in charge . |
| 61 | M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge. |
| 62 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge . |
| 63 | M&L in replacement sheet metalenclosure, single pole and neutralwith a two pin and earth plug and socket 240 Volts grade20Amps complete with onesingle poleMCB \"B\" series 10/20 A capacity complete all as specified and directed by Engineer in charge. |
| 64 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor > 0.90, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected,Class - 1,Short circuit and over circuit protection, voltage range - 180 to 270 Volts AC, temperature range 0 to 50 DegreeC andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 65 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 70, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected ,voltage range - 180 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 66 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP 65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.90, driver with Voltage range 180-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 67 | S&F in replacement of decorative type wall mounted luminaire (Comet)with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge . |
| 68 | Supply and fix surface ceiling mounted, LEDdown light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driverwithvoltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 69 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 70 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 71 | Supply and fix MCB DB SPN 12 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link completeall as directed by Engineer -in- Charge. |
| 72 | Supply and fixMCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link completeall as directed by Engineer -in- Charge. |
| 73 | Supply and fixin repair MCB SPN 63 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge . |
| 74 | Supply and fixin repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 75 | Supply and fixin repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge |
| 76 | Supply and fixing Ventilating Fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 77 | Supply and fixing Exhaust fan300 mm sweep(steel Body) , 1250 RPM, metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 78 | Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 79 | S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warrant on product.Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating. |
| 80 | Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEEfive star rated voltage range 140 - 280 volts with brushess direct current motor (BLDC)all as specified and directed by Engr in Charge. (Against BLDC converson). Old fan deposited to MES yard. |
| 81 | Supply and fix in repair MCCB 125 Amps, FP 415 volts 16KA , 4 Pole, 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 82 | Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. |
| 83 | S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 84 | Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 85 | Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through drawn through and including 25 mm dia non metallic rigid PVC conduitin walls all as specified and as directed. |
| 86 | Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduitin walls all as specified and as directed. |
| 87 | S&F plug top, 3 pin,20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge. |
| 88 | S&F socket 3 pin20 amp earth metal clad(ISImarked) complete all as specified and directed by Engineer in charge . |
| 89 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 90 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 91 | S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 92 | M & L forin replacement onlysingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 93 | M & Lin replacement foronlysingle core PVC insulated cable2.5Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 94 | M & Lin replacement foronlysingle core PVC insulated cable4Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 95 | M&L in replacement copper cable flexible 2 corePVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. Length of wire of each roll is not less than 90 mtr. |
| 96 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. |
| 97 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 150 cm long with brass nuts and rubber washers complete all as specified and directed. |
| 98 | Supply only heating element of 2 KW any type with nut bolt washercomplete all as directed. |
| 99 | Supply only replacement of capacitor 3.15 Mfd,240 V complete all as specified and directed. |
| 100 | M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out /unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge. |
| 101 | Supply only replacement of capacitor 2.5 Mfd,240 V complete all as specified and directed. |
| 102 | S&F LED 2 X 2 ft backlite surface mounted fitting 36 Wattsnot less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>70, color temperature >5700k, IP 20, Power factor<0.90, THD<10%, 25000 burning hours ,Ambient temperature 0 to 500 DegC, Voltage variation range of 180-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. |
| 103 | S&F not less than 35 Watt High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarieshould more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP-66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision ofsuitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wallcomplete as specified and directed. |
| 104 | Schedule of Credit |