| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed. |
| 2 | M&L for Brick work with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, using bricks of size 230 mm x 115 mm x 75 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M&L for half brick thick wall with Fly ash brick designation 100 Kg / Sqcm using bricks of size 230 mm x 110 mm x 75 mm confirming to IS 12894, straight or curved of on plan to any radius built in CM 1:4 complete all as specified. |
| 4 | Taking down cement plaster of any description on brick or stone masonry wall , etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified. |
| 5 | M&L for Rendering 15 mm thick in cement and sand mortar 1:4 onbrick work or cement concrete wall surfaces, finishing the surface even and smooth without using extra cement including mixing only liquid water proofing compound as per manufacturers instruction complete all as specified. |
| 6 | M&L for Rendering 15 mm thick in cement and sand mortar 1:6 onbrick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cementcomplete all as specified. |
| 7 | M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement. |
| 8 | M&L for Preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of cement based primer complete all as specified and as directed. |
| 9 | M & L for preparation of new wall plastered surfaceand applied two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete over 1 mm thick cement based wall care puttycomplete all as per manufacturer\"s specification and directed. |
| 10 | M&L for preparation of new plastered surfaces of ceiling by washing, rubbing down & stopping etc, and applying two coat of oil bound distemper (first Quality) and one coat primer of any tint / shade complete all as specified and directed. |
| 11 | M&L for preparation of old painted surfaces of ceiling by washing, rubbing down & stopping etc, and applying one coat of oil bound distemper (first Quality) of any tint / shade complete all as specified and directed. |
| 12 | M&L for Preparation of old painted surfaces of wall and applying two coats of cement base paint complete all as specified and as directed. |
| 13 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping holes and applying one coat of synthetic enamel paint(first Quality) complete all as specified and directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 15 | S&F Framedwork such as grills, gratings, etc. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290, Gde-E-165 complete all as specified and directed. |
| 16 | M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint(first Quality) over one coat of red oxide primer completeall as specified. |
| 17 | Taking down Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs complete all as specified and directed. |
| 18 | S&F Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Note :- Each line wire to be measured) |
| 19 | Demolition of existing roof treatment of any type, including screed bed or bricks etc complete all as specified and directed. |
| 20 | M&L for plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate, (Avg 50 mm thickness) in roof for paddingto achieve the 1:40 slopecomplete all as specified and as directed. |
| 21 | M&L for 15 mm thick screed bed in cement mortar 1:3 over RCC roof slab including mixing only water proofing compound as per manufacturer instruction complete all as specified and directed.(WPC will be measured and paid separately) |
| 22 | Supply only water proofing compound of approved quality complete all as specified and directed. |
| 23 | M&L for cleaning of all loose dirt and dust from roof surfaces and applying roof treatment as under ;-(a) Applying a coat of fibre reinforced PU primer confirmeing to ASTM D412 @ 30% water dilution on prepaired surfaces and allow to dry.(b) Supply and applying 2 coats of Hybrid PU based elastomeric single component coating over primer surface @ 10 Kg /10.76 Sqm total comsumption having below properties :-1. Elongation-500%-600%2. Solid contents -80%3. Tensile strenth - 1.6 N/mm24. Adhesion to concrete-2.2N/mm25. Initial hardness shore strenth-60Min.6. Tear strenth -14Mpa7. Total thickness of layer shall be 1.2-1.5mmNote ;- The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates. |
| 24 | Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries from site. |
| 25 | M&L for non skid ceramic tiles 7-8 mm thick (square or rectangular) polished area of each tile exceeding 0.11 sqm but n.exc 0.16 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles laid over and including 15 mm thick screed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for for coloured glazed ceramic tiles premium / 1st Quality in vertical surfaces of size 300 x 450 x 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, laid over and including 10 mm thick backing coat in CM 1:3 complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for colour vitrified ceramic tiles 10 mm thick (square) polished, area of each tiles n.exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colouredcement and pigment to match the tiles over and including 15 mm thick scree bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 28 | Disconnecting existing tank of capacity 500 ltrs setting aside or lowering if required and reconnecting or refixing in same positing or other position,including cleaningand removing all scale and dirt etc from tanks and from the mouths of circulating pipes etc complete all as specified . |
| 29 | Hacking out old broken glass (any thickness size, quality or description) from wooden frames or stone, concrete or bricks round, glazed with putty or fixed with bedds complete all as specified and directed. |
| 30 | S&F 3 mm thick sheet glass, ordinary quality and glzing with oil putty / timber bedds in square n. exc. 0.50 sqm in each pane complete all as specified and directed. |
| 31 | S&F 4.8 mm thick sheet glass odinary qulity and glazing with neosprene beading n.exc 0.5 Sqm in each pane complete all as specified and directed.. |
| 32 | Taking down chowkats or frame, (wooden / aluminium / steel) not exceeding 1.5 sqm in each shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 33 | Taking down chowkats or frame, (wooden / aluminium / steel) exceeding 1.5 but n exc4 Sqm in each shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 34 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 35 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 36 | Supply & fix Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop at of primer erected in position as indicated complete push pull or manual type thickness of lath is 1.25mm including taking down old shutters complete all as specified and directed. |
| 37 | S&F 100 mm size butt hinges medium weight cold rolled stainless steel complete all as specified and directed. |
| 38 | S&F 150 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 39 | S&F 150 mmAluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 40 | S&F Aluminium anodised sliding door bolt 300m long,with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 41 | S&F in repairs 600 mm x 450 mm bevelled edge mirror 5.5 mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP Brass screws and cup washers complete. |
| 42 | S&F in repairs CP mild steel gratings suitable for 75 / 100 mm dia forNT/ FT complete all as specified and directed. |
| 43 | S&F in repair PVC low level flushing cistern, valveless, syphonic action type, double push botton, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and makingconnection complete complete all as specified. |
| 44 | S&F in repair PVC connection 15 mm size with PTMT nut, length 450 mm complete all as specified and directed. |
| 45 | S&F in repair PVC connection 15 mm size with PTMT nut, length 600 mm complete all as specified and directed. |
| 46 | S&F in repair Aluminium anodised sliding door bolt 300m long,with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 47 | S&F in repairs 15 mm size Bib taps, cast iron with crutch handle, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 48 | S&F in repairs 15 mm size long body bib tap, with wall glange, long body, cast copper alloy chromium plated, fancy type with capston head, screwed for 15 mm bore iron pipe or for brass ferrule and fixed complete all as specified. |
| 49 | Supply & fix in repair Double actionfloor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloysheet foundation box, main body with stainless steel cover, governing pivot made of mild steel heavy duty fixed, complete all as specified and directed. |
| 50 | S&F in repairs 15 mm size swan neckpillar taps, cast copper alloy, chromium plated, fancy type, with capstan heads, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge. |
| 51 | S & F in repairs 15 mm size wall mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, half turn type, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F in repair 15 mm size basin mixer cast copper alloy chromium plated with capstan heads, half turn type, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe with 450 mm braided connection pipe complete all as specified. |
| 53 | S&F in repair white vitreous China wash down water closet pan (padestal pattern), fixed in position with fixing bolts,connection to drain pipe and to flushing pipe, etc., complete. |
| 54 | Supply and fixing in repairsPlastic water closet seat, white, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 55 | S&F in repairsBrass chromium plated shower rose 80 mm size without swivel joints, including fixing to steel pipe or union complete all as specified and directed. |
| 56 | S&F in repairs Aluminium body (extruded section) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters 701 to 850 mm in width and ofweight between 36 to 60 Kg and fixed, complete all as specified and directed. |
| 57 | S&F in repair 100 mm size mild steel mortice lock,for aluminium door, with 4 brass levers and duplicate key complete all as specified and directed. |
| 58 | S&F in repair ABS plastic chromium plated Health faucet fixed with spring action and lever along with Flexible hose with brass nut of length 1 m to 1.2 m fitted in the existing water connection in the toilets,Complete all as specified and directed. |
| 59 | S&F in repair brass chromium plated Jet Spray of Standard size for EWC alongwith CP connection and all fittings as fixed, complete all as specified and directed by Engineer-in-Charge. |
| 60 | S&F in repair for brass chromium plated toilet paper holder fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 61 | S&F in repairs 6 mm thick bevelled edge mirror of selected quality glass, fixedto wall with stainless steel Bolt flat head mirror screw (minimum 4 Nos per piece) with spacerscomplete all as specified and directed. |
| 62 | Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 580 x 450 mm fixed on and including new brackets complete, 32 mm size brass chromium plated waste coupling complete all as specified and directed. |
| 63 | S&F in repair 32 mm size flexible pipe of PVCfixed to WHB / urinals as waste pipe (not less than 600mm long) including PVC coupling complete all as specified and directed. |
| 64 | S&F in repair 15 mm size two way Angle cock / valve, cast copper alloy, chromium plated, fancy type with capstan head, with screwed down, screwed both end for iron pipes complete all as specified and directed. |
| 65 | S&F in repair 15 mm size two way stop cock cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified and directed. |
| 66 | S&F in repair cast iron floor trap with chromium plated grating including jointing to waste pipe wih cement mortar (75 mm bore of pipe), complete all as specified and directed. |
| 67 | S&F in repair brass Chromium plated, tubular towel rail, 20 mm dia, D type, 60 cm long between flanges, complete all as specified. |
| 68 | Dismantling sign board of any shape, type, sections including taking out embedded portion in PCC / natural ground and making good complete all as specified and directed. |
| 69 | Excavating in post holes (or similar holes) in soft/lose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engineer -in- Charge |
| 70 | M&L for PCC 1:3:6,type C2, using 40 mm graded stoneaggregate, as in foundation, filling and mass concrete complete all as specified and directed. |
| 71 | S&F for stainless steel post ornamental design 65mm nominal bore (Grade-304), minimum thickness 1.58mm (16 BS gauge), as in frame of sign boards fixed on groung/column/wall including bending, cutting, welding, jointing complete all as specified and directed. |
| 72 | S&F for stainless steel tube 40mm nominal bore (Grade-304), minimum thickness 1.58mm (16 BS gauge), as in frame of sign boards fixed on groung/column/wall or SS tube frame including bending, cutting, welding, jointing complete all as specified and directed. |
| 73 | S&F for stainless steel tube 25mm nominal bore (Grade-304), minimum thickness 1.58mm (16 BS gauge), as in frame of sign boards fixed on groung/column/wall or SS tube frame including bending, cutting, welding, jointing complete all as specified and directed. |
| 74 | Supply, installation, hoisting and fixing in position ACP (aluminium composite panels)board made up of ACP (aluminium composite panels ) sheet 3 mm thick of size, shape as required, colour as approved by GE, with cleat including necessary handling arrangement of stainless steel flat of suitable size all around, sealing with silicon joint sealantandcomplete all as specified and directed. |
| 75 | S&F High Intensity Prismatic retro-Reflective Sheeting of approved colour / shade fixed on aluminium sheet fully covered including lattered, writing information / logo with both side same sheeting by computerised cutting in white colour / shade. The letters approximately covering upto 60% area of the board complete all as specified and directed. |
| 76 | S& F in repairsprecast cement concrete1:2:4 type BO for louvres and jallies, 25mm thick (mea sured solid), in cluding all mould- ings set in C:M 1:4 including taking down old jallies all as specified and directed. (up to 25 mtrs height including necessary scaffolding) |
| 77 | M&L forSuper heavy series PVC Wall panelling consisting of 5-8 mm thick Plain / wood colour PVC sheet ofapproved coloured & pattern, fixed on walls as per manufacturesinstruction including dismantling of existing panelling complete all as specified & directed. |
| 78 | Taking down PVC pipes of (any sizes) including all fittings complete all as specified & directed. |
| 79 | Temporarily blocking of inlet of septic tanks / manhole of depth0.50 to 1.5 metre with suitable wooden plugs / gunny bags and pumping / bailing out effluent and taking out / removing the accumulated sludge soil sewage / any other foreign / foul materials etc (solid / semisolid) from the septic tanks / manholes, complete and cleaning the septic tank / manholes with fresh water by mechanically / manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by Enginee-in-Charge. |
| 80 | Temporarily blocking of inlet of septic tanks / manhole of depth1.50 to 4.50 metre with suitable wooden plugs / gunny bags and pumping / bailing out effluent and taking out / removing the accumulated sludge soil sewage / any other foreign / foul materials etc (solid / semisolid) from the septic tanks / manholes, complete and cleaning the septic tank / manholes with fresh water by mechanically / manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by Enginee-in-Charge. |
| 81 | Temporarily blocking of 150 mm bore sewage line with suitable wooden plugs / gunny bags and cleaning the same by rodding and removing the sludge alongwith brick bats / stones / broken bottles / any other foreign materials etc complete and cleaning the sewage line with fresh water by mannually / mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed. |
| 82 | Temporarily blocking of 200 mm bore sewage line with suitable wooden plugs / gunny bags and cleaning the same by rodding and removing the sludge alongwith brick bats / stones / broken bottles / any other foreign materials etc complete and cleaning the sewage line with fresh water by mannually / mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed. |
| 83 | Demolition and breaking 150 mm bore drain pipes of any descreption including demolition of PCC packing uner and haunching against the sides of pipes including removal of debries to a distance exc 1.5 km but n.exc 5 Km complete. |
| 84 | M&L for 150 mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed. |
| 85 | M&L for PCC 1:3:6, type C2 using 40 mm graded stone aggregate as in bed to drain pipes of 150 mmbore dia including packing uner and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 86 | Dimolition of stone slab of any description / thickness in floors, aprons etc including cement mortar bedding laid bedded and pointed in any mortar, including removal of debries to a distance exc 1.5 km but n.exc 5 Km complete all as specified and directed. |
| 87 | M&L for 75 mm thick plain cement concrete 1:4:8, type D- 2,using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 88 | M&L for 60 mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade, in gray cement with approved design & pattern / shape laid as in foot path, / hard standing / drive ways or parking etc., made by table vibratory method using PU mould, laid over and including 20 mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks over the the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 89 | M&L for chequered cement concrete tiles of size 30 cm x 30 cm x 20 mm thick, with grey cement and pigment set & jointed with gray cement slurry and pointed with gray cement & pigment laid over and including 20 mm thick screed bed in CM 1:4 as in floors complete all as specified. |
| 90 | Deployment of manpower / tools / machinery etc for Boring / Drilling bore well of 300 mm dia & upto 20 metre depth below ground level, in any type of soil, for casing strainer pipe by sutable method prescribed in IS 2800 (Part I), Inculding collecting samples from different strata, preparing and submitting strata chart / bore log, Including hire& running charges of all equipments, tools , plants& machineries required for the job, all complete as per directionof Engineer-in- charge. |
| 91 | Excavating over areas, n exc 1.5 m deep and getting out in Soft / loose soil all as specified and directed by Engineer-in charge. |
| 92 | Extra over item above for each additional 1.5 m depth or part there of in depth beyond the first 1.5 m. all as specified and directed by Engineer-in charge. |
| 93 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m indepth and getting out in soft/loose soilfor foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipes/cable etc. n exc 10 sq m on plan and not exc 1.5 m in depth complete all as specified and directed. |
| 94 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, using excavated soil all as specified and directed by Engineer-in charge. |
| 95 | Removing excavated soil to a distance exc 250 m but n exc 500 m and depositing where directed at a level n\"exc. 1.5 m above the starting point . |
| 96 | M&L for pea Gravel brought direct from river bed, packing in tube well construction in accordance with IS 4097, including providing graval of size 3 to 6 mm), in required grading as per actual requirement , all completeas per direction all as specified and directed by Engineer-in charge. |
| 97 | Material & Labour for filling of dry rever sand (course aggregate), in any location all as specified and directed by Engineer-in charge. |
| 98 | M&L for Rendering 15 mm thick in cement and sand mortar 1:4 onbrick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cementcomplete all as specified.. |
| 99 | M&L for Plain Cement concrete 1:3:6 type C-2 using 40mm graded stone agg as in drains complete all as specified and directed by Engineer-in charge. |
| 100 | M&L for PCC 1:2:4 type -B0 using 12.5mm graded stone aggregate in surface channel and drain all as specified and directed by Engineer-in charge. |
| 101 | M&L for Extra for forming fair finished drain orchannel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc all as specified and directed by Engineer-in charge. |
| 102 | M&L for Add or deduct to item above for each 25 mm girth or part thereof over or under 30 cm complete all as specified and directed by Engineer-in-charge. |
| 103 | M&L for cutting of existing bituminous / concrete road / pavement for 200 mm deep and make good with 200 mm thick PCC 1:2:4 Type B1 (using 20mm graded aggregate) complete all as specified and directed by Engineer-in charge. |
| 104 | S&F 160 mm dia PVC ( SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including fixing clips, bends, elbow, shoes bends etc. complete all as specified and directed by Engineer-in charge. |
| 105 | M&L for PCC 1:2:4 type -B0 using 12.5 mm graded stone aggregate as incills, steps, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork complete all as specified and directed. |
| 106 | M&L for precast cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in, cover slabs for man holes etc., manhole covers, drain covers, and similar articles including necessary form work (reinforcement measured and paid seperately) complete all as specified and directed. |
| 107 | M&L for RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified |
| 108 | M&Lfor formworkto soffits of suspended slabs, such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizontal or sloping) for fair finished faces complete |
| 109 | M&L for Mild steel TMT bars 10 mm dia and over, cut to length bent to shape required including crancking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 110 | Supplying, assembling, lowering and fixing in vertical postion in bore well, unplasticized PVC medium well casing (CM) pipe of 200 mm dia, conformaning to IS 12818, including required hire and labour charges, fitting& accessories etc.all complete for all depths as per direction of Engineer-in-charge. |
| 111 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well, screen (RMS) pipes 200 mm dia, with ribs, conformaing to IS. 12818, including hire & labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer-in-Charge. |
| 112 | S&F UPVC Bail plug / Bottom plug sutaible for 200 mm dia pipe, fixed to the bottom of pipe assembly of tubewell as per IS:2800 (Part-I) all as specified and directed by Engineer-in charge. |
| 113 | S&F 200 mm size threaded mild steel cap or spot welded plate to the top of bore well housing / casing pipe, removable as per requirement, all complete for borewell of 200 mm dia all as specified and directed by Engineer-in charge. |
| 114 | M&L for PVC bend for 200 mm bore pipe with nylon wiremesh for to covering one endcomplete all as specified and directed. |
| 115 | S&F 200 mm bore PVC air vent bend U type complete all as specified and directed. |
| 116 | Supply, filling, spreading & levelling stone aggregate 40 to 80 mm nominal size, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction all as specified and directed by Engineer-in charge. Note:- Measurment shall be carried out for net finished volume of work and void will not be deducted, for payment. |
| 117 | M&L for pea Gravel brought direct from river bed, packing in tube well construction in accordance with IS 4097, including providing graval of size 6 to 12 mm), in required grading as per actual requirement , all completeas per direction all as specified and directed by Engineer-in charge. |
| 118 | Deployment of refrigerent mechanic for Attending the Complaints of Split AC / Window AC for rectification of minor defects etc at any location of Cantt area complete all as directed by EIC. |
| 119 | M&L for dismantling of burnt contactor and Supply & fix power contactor 1ph suitbale for Tower AC/ split AC/ Window AC of any make , model and capacity complete all as specified and directed by Engineer-in- Charge. |
| 120 | M&L for dismantling of defective outdoor stand of split ACand supply & fixing outdoor stand of split AC at suitable location complete all as specified and directed by EIC. |
| 121 | M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 36 Mfd in plastic/ metal container complete all as directed by EIC. |
| 122 | M&L for dismantling of burnt capacitor and Supply & Fix capacitor ofcapacity 50+5Mfdin plastic/ metal container complete all as directed by EIC. |
| 123 | M&L for dismantling of burnt capacitor and Supply & Fix capacitor ofcapacity 45 Mfdin plastic/ metal container complete all as directed by EIC. |
| 124 | M&L for dismantling of burnt Indoor unit Censor and Supply & Fix Censor (in each set) of Indoor unitSplit ACInverter type (Cooling / Hot and cold type)of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC. |
| 125 | M&L for dismantling of burnt Outdoor unit Censor and Supply & Fix Censor (in each set) of Outdoor unitSplit ACInverter type (Cooling / Hot and cold type)of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC |
| 126 | M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC all as directed by EIC. |
| 127 | M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC Inverter type (cooling only / hot & cold type) all as directed by EIC. |
| 128 | M&L for dismantling of burnt Swing motor and Supply & FixSwing motor for 1.5 TR / 2 TR window AC all as directed by EIC. |
| 129 | M&L for dismantling of defected brass suction valve and Supply & fix brass suction valve size 3/8\" complete all as specified and directed |
| 130 | M&L fordismantling of defected Discharge valve and Supply & fix Discharge valve size 1/2\" complete all as specified and directed . |
| 131 | M&L for dismantling of defectedcharging valve and Supply & fix charging valve size 1/4\" complete all as per directed by EIC |
| 132 | M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 3/8\" complete all as specified and directed |
| 133 | M&L fordismantling of defected flare nuts and Supply & fix flare nuts size 1/4\"complete all as specified and directed |
| 134 | M&L fordismantling of defected flare nuts and Supply & fix flare nuts size 1/2\" complete all as specified and directed |
| 135 | M&L fordismantling of defected flare nuts and Supply & fix flare nuts size 5/8\" complete all as specified and directed |
| 136 | M&L fordismantling of defected copper gas filter and Supply & fix copper Gas filter for AC 1.5 TR / 2 TR capacity all as specified and directed |
| 137 | M&L for dismantling of burnt connector and Supply & fix connector suitbale for Tower AC/ split AC/ Window AC of any make , model and capacity complete all as specified and directed by Engineer-in- Charge. |
| 138 | M&L for renew PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm)all as specified and directed . |
| 139 | M&L for renew MCB SP-6 to 32 Amps ratingto be housed in DBs catered here in after complete all as specified and directed :-(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating):- |
| 140 | M&L for renew Mettalic Plugs ( top) of AC box 20A, specified make , 2P+Eand connectingall as specified and directed |
| 141 | M&L for repair/ renew copper capillary of size 0.60 mm complete all as specified and directed |
| 142 | S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified |
| 143 | Supply only of puff insulation of size1/2\" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC |
| 144 | Supply only of puff insulation of size1/4\" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC |
| 145 | Supply only of puff insulation of size5/8\" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC |
| 146 | Supply and fix PVC pipe nylon imbraided 15 mm dia forcondensed waterdrain fitted with clamps/concealed in wall all as specified and directed. |
| 147 | Supply and fix in repairof copper tubing 3/8\"diawith puff insulation complete all as specified and directed . |
| 148 | Supply and fix in repairof copper tubing 1/2\" dia with puff insulation complete all as specified and directed . |
| 149 | Supply and fix in repairof copper tubing 1/4\" dia with puff insulation complete all as specified and directed . |
| 150 | Supply and fix remote hand set of window type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar) |
| 151 | Supply and fixremote hand set of Split type air conditioner of cap 1.5/2.0 TR of existing make with and includingpencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar) |
| 152 | Supply and fixremote hand set of Inverter type Split air conditioner of cap 1.5/2.0 TR of existing make with and includingpencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar) |
| 153 | Supply and fix in repair Air Censor for temperature control for 1.5 TR/ 2.0 TR Split AC/ Tower AC/ Window AC complete all as specified and directed. |
| 154 | Supply and fix PVC fan blade with gun metal bush of blower , Screw complete as per complete all as directed by EIC |
| 155 | Supply and fixPVC blower for window A.C. as per sample complete all as specified and directed |
| 156 | M&L for taking down of Split type AC (Indoor & outdoor complete) of any capacity or model and transporting and refixing at New Location to make it fully functional again at new location withall as specified and directed by Engr-In -Charge. |
| 157 | M&L for taking down of Window AC any capacity or model, transporting and refixing at New Location to make it fully functional again all as specified and directed by Engr-In -Charge. |
| 158 | Taking out defective blower motor from window type AC of cap 1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HPblower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed. |
| 159 | Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit)and supply & fixing new blower motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed. |
| 160 | Dismantling of burnt outdoor fan motor of 1.5 TR/2.0TR split AC (outdoor unit)and supply & fixing new outdoor fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample completeall as specified and directed. |
| 161 | Dismantling of existing window type AC. from its location andrefixingafter doing by Servicingby oiling & cleaning with liquid soap , cleaning of fins by means of air blower and water with pressure jet and changing of air filtercomplete with cleaning of Cooling & Condensing coil all as directed by EIC. |
| 162 | M&Lfor Water dropping leaked repaired ofSplit AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC |
| 163 | M&Lfor convert to heating/ cooling mode (only reverse cycle connection) in Split AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC |
| 164 | Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing new indoor unit Inverter type (hot & cold) type of the same capacitywith blower motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted all as specified and directed.( Make :- Bluestar/ Voltas//LG/ Hitachi) |
| 165 | Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacityand supply & fixing new condensing unit (outdoor unit) Inverter type (hot & cold) of the same capacitycomplete with compressor,copper condensing coil, coil frame, wiring kit and running capacitor, relay,condensing motorwith blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed . ( Make :- Bluestar/ Voltas//LG/ Hitachi) |
| 166 | Dismantling of defective cooling coil of 1.5 TR/2.0 TR window type AC of any make and S&Fcooling coil in copper by brazing, leak proove and vaccumination complete all as specified and directed |
| 167 | Dismantling of defective condencing coil of 1.5 TR/2.0 TR window type AC of any make and S&Fcondencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed |
| 168 | Dismantling of defective cooling coil of 1.5 TR/2.0TR Split AC of any make and S&Fcooling coil in copper by brazing, leak proove and vaccuminationcomplete all as specified and directed |
| 169 | Dismantling of defective condencing coil of 1.5 TR/2.0TR Split AC of any make and S&F condencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed |
| 170 | Dismantling of burntfan motor of 1.5 TR/2.0TR window AC double shaft and supply & fixing newfan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample completeall as specified and directed. |
| 171 | Supply and fixing in repairs front grill quality for window AC of 1.5 TR/ 2 TRof Make National/ Casmo/LG/Carrier / Blue Star/Samsung/ Voltas all as specified and directed |
| 172 | M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation andcharging/ topup of refrigerant gas R-22/R-32/R-410 into the system for 1.5 TR/2.0 TR capacity split type AC all as specified and directed. (The refrigerant gas will be providedby Contractor) |
| 173 | M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation andcharging of refrigerant gas R-22/R-32/R-410 into the system for 1.5/2.0 TR capacity window type AC all as specified and directed. (The refrigerant gas will be providedby Contractor) |
| 174 | Supply & Charging in full or Top up the AC unit of 1.5 TR / 2 TR split AC/window AC unit with refrigerant gas R-22/R-32/R-410 in required Qty complete all as specified and directed (The refrigerant gas will be providedby Contractor) |
| 175 | Supply & fix in repair/ renew of New display suitable for Split AC/ window AC/ Tower AC of any make/ model & capacity complete all as directed by EIC |
| 176 | Supply & fix in repair/ renew of New display suitable for Inverter Split AC (cooling or Hot & cold type) of any make/ model & capacity complete all as directed by EIC |
| 177 | M&L for dismantling of defective display of 1.5/2.0 TR capacity Split AC/ Window AC of any make and transporting to contractors workshop for repair of the same,transporting back to site & refixing to ensure proper functioning of the AC complete all as specified and directed. |
| 178 | Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit) Inverter Split AC and supply & fixing new blower motor of Inverter Split AC (Cooling or hot & cold type) Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed. |
| 179 | Dismantling of burnt outdoor fan motor of 1.5 TR/2.0 TR split AC ( outdoor unit) Inverter Split AC and supply & fixing new outdoor fan motor of Inverter Split AC (Cooling or hot & cold type) Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed. |
| 180 | S&F reverse cycle solenoid valve in splittype AC 1.5 / 2 TR capacitywithnecessaryextension to suction/ discharge copper tubing & toggle switch complete all as specified and directed by Engineer-in- Charge. |
| 181 | S&F in replacement New PCB for indoor unit of (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5/2.0 TR Split ACcomplete all as specified and directed. |
| 182 | M&L for dismantling of defective PCB of 1.5/2.0 TR capacity Split AC of any make from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed. |
| 183 | M&L for dismantling of defective PCB of 1.5/2.0 TR capacity window AC of any make from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed. |
| 184 | S&F in replacement New PCB for window AC of Cap 1.5/2.0 TR of any make/ modelcomplete all as specified and directed. |
| 185 | S&F in replacement New PCB for indoor unit of (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5 / 2.0 TR Split AC Inverter type ( cooling only/ hot & cold) complete all as specified and directed. |
| 186 | S&F in replacement New PCB for Outdoor unit (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5 / 2.0 TR Split AC Inverter type ( cooling only/ hot & cold) complete all as specified and directed. |
| 187 | M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC inverter type (cooling only/ hot & cold) of any make from indoor or outdoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed. |
| 188 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc for taking credit and making good disturbed surfaces of walls, floors,etc.as directed. |
| 189 | Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including surface type caping & casing not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete. |
| 190 | All as per Item No 189 above but for one 5 pin 5 Amp socket outlet point on an independent board. |
| 191 | All as per Item No 189 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch. |
| 192 | All as per Item No 189 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm. |
| 193 | Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through existing concealed PVC conduit.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete. |
| 194 | All as per Item No 193 above but for one 5 pin 5 Amp socket outlet point on an independent board. |
| 195 | All as per Item No 193 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch. |
| 196 | All as per Item No 193 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm. |
| 197 | Material & Labour for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn existing concealed PVC conduit, including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel sunken type terminal box up to 8 module suitable for modular switch complete.Note:- Modular type cover plate & frame will be measured & paid separately. |
| 198 | All as per Item No 197 above but for one 5 Amp socket outlet point on an independent board. |
| 199 | All as per Item No 197 above but for one 5 Amp socket outlet point on the same board with other switch. |
| 200 | All as item no 197 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board. |
| 201 | S & F switch piano flush button single pole one way 5 Amp 240 volt complete all as directed. |
| 202 | S & F switch piano flush button single pole one way 15 Amp 240 volt complete all as directed. |
| 203 | S&F socket outlet flush type multipurpose 2 in1, 3 pin 5 and 16 Amp, 230 volts complete as directed. |
| 204 | S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6 Amp, 230 volts complete as directed. |
| 205 | S&F fan regulator electronic,step up socket type,230 volt,125 W and conection complete all as directed. |
| 206 | S&F modular type one way switch, 6 Amp 240 volt in one moduel including connecting complete as specified and directed. |
| 207 | S&F modular type one way switch, 16 Amp 240 volt in one moduel including connecting complete as specified and directed. |
| 208 | S&F modular type 6 Amp 5 pin universal socket in two moduel , 240 volts including connecting complete all as specified and directed. |
| 209 | S&F modular type 6 / 16 Amp 5 pin universal socket suitable in two moduel , 240 volts including connecting complete all as specified and directed. |
| 210 | S&F Modular white cover plate with frame 2 module. |
| 211 | S&F Modular white cover plate with frame 3 module. |
| 212 | S&F Modular white cover plate with frame 4 module. |
| 213 | S&F Modular white cover plate with frame 6 module. |
| 214 | S&F Modular white cover plate with frame 8 module. |
| 215 | Supply & fix modular fan regulator 100 / 100 W, in 2 Module for ceiling fan and connecting as directed. |
| 216 | S&F ceiling rose polycarbonate body surface type three terminal complete as directed. |
| 217 | Supply and fix in repairs recess type 36 watt LEDllight fittings ofsize 600 mm x 600 mm, made of CRCA powder quoted housing, fully covered by PMMA acrylic Lumio Diffuser, LED Used shall be SMD type, fixed in 15 feet hight false ceiling of any pattern / material by cutting opening of sutable size, including electrical connection all as specified and directed. |
| 218 | Supply and fix in repairs recess type 30 watt LEDllight fittings ofsize 1200 mm x 300 mm, made of CRCA powder quoted housing, fully covered by PMMA acrylic Lumio Diffuser, LED Used shall be SMD type, fixed in 15 feet hight false ceiling of any pattern / material by cutting opening of sutable size, including electrical connection all as specified and directed. |
| 219 | S&F 18 watt LEDlamp 4 pin type, fixed in existing lightfittings complete all as secified and directed. |
| 220 | S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed. |
| 221 | S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed. |
| 222 | S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed. |
| 223 | S&F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, TPN 4 way with 200 Amps rated copper busbar, 415 Volts earth bar IP 43 protection, fixed flush to wall complete all as specified and directed. |
| 224 | S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, \"C\" curve complete all as specified and directed |
| 225 | S&F MCB, single pole & neutral 40 Amp, 240 volts, 10 KA breaking capacity, \"C\" curve complete all as specified and directed. |
| 226 | S&F MCB, triple pole & neutral 63-100 Amp, 415 volts, 10 KA breaking capacity, \"C\" curve complete all as specified and directed. |
| 227 | S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with including one single pole MCB 20 AmpsC curve complete all as per specified and directed . |
| 228 | S&F in repairs VTPN distribution board, 4 way double door suitable for incommer 4 pole MCCB, 415 V & SP / TP MCB as outgoing, 200 Amps rated Busbar, inter connection link, cable ties, earth bar etc incl necessary civil works and electrical connections with suitable lugs / spreader links complete all as specified and directed by Engr-in-charge. Note: MCCB & MCB to be measured and paid seprately. |
| 229 | S&F MCCB 63 -100 Amps 415 volts, 4 pole 16 KA breaking capacity fixed in DB and connecting complete as directed. |
| 230 | S&Finreplacement modular switches 1 way 6 / 10A,1 module, |
| 231 | S&Finreplacement modular switches 1 way 16A,1 module, |
| 232 | S&Finreplacement modular 6 A sockets-2/3 pin combine 2 module, |
| 233 | S&Finreplacement modular 6A/16A sockets-2/3 pin combine 2 module, |
| 234 | S&Finreplacement fan step regulator modular 100/120W, 2 module, |
| 235 | S&Finreplacementmodular white cover plate with frame, 2 module, |
| 236 | S&Finreplacementmodular white cover plate with frame, 3 module, |
| 237 | S&Finreplacementmodular white cover plate with frame, 4 module, |
| 238 | S&Finreplacementmodular white cover plate with frame, 6 module, |
| 239 | S&F in replacement switch piano flush button single pole one way 5 / 6 Amp 240 volt complete all as directed. |
| 240 | S&F in replacement of switch piano flush button single pole one way 15 / 16 Amp 240 volt complete all as directed. |
| 241 | S&F in replacement of socket outlet flush type multipurpose 2 in1, 3 pin 5 / 6 and 15 / 16 Amp, 230 volts complete as directed. |
| 242 | S&F in replacement of socket outlet flush type multipurpose 2 in1, 5 pin 5 Amp, 230 volts complete as directed. |
| 243 | S&F in replacement of switch socket outlet combination flush type multipurpose 2 in1, 3 pin 5 and 15 Amp, 230 volts complete as directed. |
| 244 | S&F in replacement call bell AC single pole 240 volt ding dong type. |
| 245 | S&F in replacement high range up to 40 mtr, cordless call bell with wireless remote including batteries all as specified and directed. |
| 246 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring, concealed in wall including cutting chases in wall and making good disturbed surface to match of walls / ceiling complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 247 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 10.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 10.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring, concealed in wall including cutting chases in wall and making good disturbed surface to match of walls / ceiling complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 248 | Material & Labour for sub main wiring with 4 run single core multistranded copper conductor cable, of size 10.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 10.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring, concealed in wall including cutting chases in wall and making good disturbed surface to match of walls / ceiling complete.Note: (i) 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 249 | Dismantling desert cooler of any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts & motor, reassembling andinstallation of the same on same location and making electric connection required to make fully functional etc. complete all as specified and directed.(Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
| 250 | Supply only of PVC front grill complete all as specified and directed. |
| 251 | Supply only of sprinkle pipe, PVC heavy duty 15 mm dia with tee, elbow etc. for 24\"/18\" sweep desert cooler complete all as specified and directed. |
| 252 | Supply onlyofPVC distributor suitable for 15 mm dia PVC Pipe, PVCelbow & connection of PVC pipe from pump to distributor suitable for 18\"/24\" sweep desert cooler complete all as specified and directed. |
| 253 | Supply Onlyof PVC connection 15 mm dia with brass ferule both and length 600 mm complete all as specified and directed. |
| 254 | Supply only of PTMT float valve , 15 mm dia complete all as specified and directed(Make Prayaga) |
| 255 | Supply only of copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed. |
| 256 | Supply only of copper conductor three core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed. |
| 257 | Supply only of PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor complete all as specified and directed. |
| 258 | Supply only of replacement submersible pump for desert cooler single phase, 1/40 HP,230volts complete all as specified and directed. |
| 259 | Supply only of Exhaust fan blades 18\"/20\" sweep heavy duty(as per sample) complete all as specified and directed. |
| 260 | Supply only of wood wool pad (As per sample) including wiremesh (jali) suitable for desert cooler325 mm to 500mm sweep complete all as specified and directed. |
| 261 | Supply only kit fan, motor, minimum 1 inch core, copper winding, less consumption of electricity, more durable, heavy duty, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18\"sweep size suitable for desert cooler complete all as specified and directed. |
| 262 | Supply only exhaust fan motor, single phase, 230 volt AC, 1/3 HP, copper winding less consumtion of electricity, more durable heavy duty complete with blade arm 18\"/20\"sweep size suitable for desert cooler complete all as specified and directed. |
| 263 | Renewal of set of 3 panels made out of PGI sheet24 gauge thick with wood wool pads and wiremesh, in required quantity duly filled complete all as specified and directed. |
| 264 | Taking out defective burnt exhaust fan offollowing sweep and of any makeand transporting tocontactor\"s workshop, opening of exhaust fan/taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position 18\"/24\" size (exhaust fan) complete all as specified and directed. |
| 265 | Taking out carefully 325 to 500/600 mm sweep desert cooler from its existing position from stand or pillar, removing the side panels, taking out cut wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) including one coat of black japan paint in side the base of tank tank after preparation of old painted surfaces and reassembling and fixing in positioncomplete all as specified and directed. |
| 266 | M&L for repairing of leakage of tank by brazing/solderingof any size of desert cooler, testing the leakage water complete all as specified and directed. |
| 267 | Renewal of desert cooler body, suitable for 450 mm/500 mm sweep exhaust fan made out of 24 gauge PGI sheet with front grill, side panel include wood wool pad/ wiremesh set, switch, regulator, flexible cable include plug top complete all as specified and directed. |
| 268 | Design, procure, erection, installation, testing and commissioning including connecting to local utility grid, Roof top On-grid Solar Photovoltaic Plant of 20 KWcapacity at RTC Building including Solar Photovoltaic Modules, DC and AC Cabling, Module Mounting Structures, Array Combining Boxes, Lightning Protection of SPV modules and other accessories, Central Inverter and Power Conditioning Unit, Weather Station and Data Monitoring System all as per detailed specifications given in Particular Specification, latest MNRE guidelines and directions, consisting of all requisite accessories (BOS-Balance of System) and incuding the following main componenets:-Make :1Make of Module / Solar PV Panel shall be as per MNRE approved list of manufacture and modules having IEC / BIS certificate. Authorized testing laboratories /centre |
| 269 | 2.The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction & Part 2 – requirements for testing, for safety qualification or equivalent IS. PV modules must be tested and approved by one of the IEC authorized test centers. ALMM certification is required and compulsory for solar PV moduel. |
| 270 | 3.Inverter / PCU- shall have BIS certification and 10 years warrenty. Balance of system (BOS)items / components: The BOS items / components of the SPV power plants / systems deployed under this project must conform to the latest edition of IEC or equivalent BIS Standards / MNRE specifications / as specified at Para 2.1 of minimal technical requirements / standards for SPV system / plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. |
| 271 | (A) Crystaline Silicon Solar Photovolaic ModulesBifacial technology (efficiency will have higher module conversion) ofminimum 550 to 590 Wp or more (module power and number of modules to be selected according to available roof top area & adequate walkway), having cell efficiencyunder standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have thefeatures as per detail in PS speciffied.- |
| 272 | (a)The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under:-(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to -4°C to +60 °C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warrented for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. |
| 273 | (e) Each module shall have RFID tag encapsulated with solar cell bearing following details :- (i)Name of Manufacturer of SPV Module(ii) Name of Manufacturer of Solar Cell(iii)Month and year of Manufacturing (seperately for cell and module)(iv) Country of Origin (both cell and module) (Make in INDIA only)(v)Peak wattage, Im, Vm and fill factor of the module(vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate.(vii)Unique serial no and model no of module(viii)IV curve of module |
| 274 | (f)The temperature coefficient of power for the module shall not be more than 0.50% per degree Celcius.(g) Every module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID or the latest relevant International Electrotechnical Commission (IEC).(j) It shall also be in confirmity to latest minimum technical specification issued by MNRE & IREDA from time to time. Modulesshould be of MNRE & IREDA approved companies and as per latest IEC/IS standards. |
| 275 | (l)RFID reader is to be provided by contractor. (m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be adjusted or as per IEC guideline until the plant meets the specified performance ratio requirements.(n)Any damage to the existing roof treatment of any type due to the Installation of Solar Power System shall be Re-done/made good as per existing treatment. Cost of the same shall be included in the unit rate quoted. Nothing extra shall be admissible on this Account. |
| 276 | (B)Junction Boxes : Supply and fix jucntion boxes of suitable Nos (as per design) / OEM recommendations inputs and suitably rated output having separate DC fuses for both (+) & (-) on input and isolator on output terminal for each string. Each junction box must have a spare input terminal. The junction boxes shall be dust and vermin proof and water proof made of FRP / Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relecant standard. The junction box shall have suitable arrangement of the following :- |
| 277 | (a)The strings are required to be connected to the copper bus bar through individual fuses.(b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB.(c)Provide a test point for each sub group for quick fault location and to provide group array isolation.(d)Each array box shall be of relevant IEC standard.(e) Each array junction box shall have suitable bypass & reverse blocking diodes for maximum DC blocking voltage of 1000 V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperaturesand shall have efficiency of 99.98% confirmed by appropriate IEC standard.Make : As per OEM |
| 278 | (C)DC Cables : Suitable size of XLPE insulated tinned Copper cable as per latest IEC/IS speciffication and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II) and shall be as under :-(i) Solar Cable -From Module to DCDB & Inverter- 1Cx6 Sqmm tinned copper cables,UV resistant,Solar Cable,TUV certified1800Vdc.(ii) AC Cables(Inverter to AC distribution Box):-4Cx25 Sqmm power cables Cu conductor,XLPE insulation,unarmoured PVC outer sheath 1100V(Flexible Type) |
| 279 | (a) All cables and connectors for use of installation shall be of Solar grade which can withstand harsh enviromnetal conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/ IS.(b) All the cables / wires shall be provided with UV resistant printed ferrules for DC side.(c) The size of the cable shall be such that avarage voltage drop at full power from PV module to inverter shall be less than 1.5%.(e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable sizeor as per OEM recommendation. (f) The cost of interconnecting DC Copper cable (not less than 6 sqmm of size) , MS cable trays, and earth work for trenches/ MS cable trays suitable to accommodate Solar grade cables from SPV module upto inverters are included in the item. |
| 280 | (D) Module Mounting Structure (MMS) : Design, procure, fixing, support structure made of hot dipped galvanised C section fabricated with min not less than 3 mm thick sheet, including necessary PCC (1:2:4) foundation and associated work (cutting, grouting, PCC filling, dispoing waste material, etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 200 km per hour. The mounting structure is to be installed over RCC Roofs. It shall also occupy minimum space without sacrificing the output of SPV panels & adequate space between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, mounting structure including module mounting structure shall have to be adequately protected from the atmosphere and weather prevailing in the area. All the fastners shall be of Stainless Steel of grade SS316. |
| 281 | Notes : (a) Anti theft fastners of Stainless Steel on MMS be provided for each module. (b) The module mounting structure shall be fixed to provide maximum generation. (c) MMS design shall bevetted by Govt engg college / Institute and approval be accorded by GE. (d) The height of Roof top MMS shall be as per latest MNRE & IREDA guidelines. (e) MMS to be made available by Bidder at site. All bolts, nuts, panel mounting clamps fasteners shall be of stainless steel of grade SS 304 and must sustain the adverse climatic condition. |
| 282 | (f) Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts (SS-304). (g) Necessary protection towards rusting need to be provided either by coating or anodization.The prospective Installer shall specify installation details of the solar PV modules and the support structures with layout drawings and array connection diagrams. The work shall be carried out as per the designs approved by the Engineer Incharge. |
| 283 | The frames and leg assemblies of the array structures shall be made of MS hot dip galvanized.Minimum thickness of galvanization should be at least 600 gsm. |
| 284 | All fasteners shall be of Stainless steel-SS 304 Nut & bolts, supporting structures including module Mounting Structures shall have to be adequately protected against all climatic condition. |
| 285 | (E) Lightning Protection for PV Array : Design, procure and fix lighting arrestor system cofirming to IS15086 / IEC-62305 (Part 1 - 4) on the roofs. The air terminalshall be fixed at the top of GI elevation pole with base so as per IEC speciffication / IS, the structure to be protected. Its height above roof level shall be depend upon the level of protection and protection radii required as per IEC speciffication. |
| 286 | Notes : (a) The cost of all equipments, Copper strip upto earth test point, LA, etc., shall be deemed to be included in this item. (b)The cost of sufficient earthing for lightning protection is also included in this item as directed by engr-in-charge and no extra payement will be made to the contractor on this account.(c) Provision of earthing, numbers of earthing and earth strip / cable etc for earth of solar PV module, arra, inverter, dc & ac boxes and for LAetc as per latest IS / MNRE & IREDA norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account in case of any dispute decision of AO will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). |
| 287 | (F) Power Conditioning Unit : Procure, fixing, testing and commissioning of 20 KW AC (nominal power), Solar power inverter suitable to convert DC power of Solar PV module/ array to AC for further feeding to grid confirming to IEC : 61683 for efficiency, IEC : 62109-1 or equivalent for safety and IEC : 62093 for reliability. The input DC & output AC technical specification of Inverter as speciffication in PS.Input (DC) and Output AC |
| 288 | Solar Grid Tie Inverter (Output AC)all parameter for output of Inverter specified in PS(p)Operating temperature upto 85 degree centigrade(q)The inverter shall have minimum IP-67 protection, ground fault monitoring, grid monitoring, protection for anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature.(r) The inverter shall adjust voltage and frequency levels to suit the grid.(s)The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. |
| 289 | (t) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array.(u)Monolithic design of inverter is not permitted.(v)The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by suitable capacity of MCCB.(w) The Inverter monitoring portal should be on company\"s website and mobile based application with their logo on portal. Remote Monitoring system (RMS) should be provided free of cost for a period of 25 years. |
| 290 | (x)The inverter should have MODBUS, PROFIBUS, ETHERNET common ports.(y) The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of inverter componant failure or from parameters beyond the inverters safe operating due to internal and / or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, SPD & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. |
| 291 | (z)The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741 or equivant IS) and lightening.(aa) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (bb)Inverter generated harmonics, flicker, DC injection limits, Volt range, frequency range and antiislanding measures should follow latest IEC 62116 / BIS Code. |
| 292 | Protection features- Inverter should have following protections:-(i) Anti islanding.(ii) Over voltage Protection(iii) Over Current Protection(iv) Over temperature protection(v) Reverse polarity Preotection(vi) Surge Protection(vii) Short Circuit (vii) Frequency Variations. |
| 293 | (G) Net Metering : Quoted rates inclusive ofinstalltion of Net meter of approved make. |
| 294 | (H) Balance of System (BOS) Items / Components :- The BOS items /components of the SPV power plants / systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/ MNRE specifications/ as specified in Para 1.01 of \"Minimal Technical Requirements\"/ \"Standards for SPV System / Plants\" to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. |
| 295 | Notes : (a)The contractor must visit the site before quoting the rates for this item to asses the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete.(b) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work,etc., complete as per IREDA latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. |
| 296 | (c) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed by Engr-in-charge.d) Make of PV module,cable,Inverter,PCU,AC-DC-DB,SPD shall be all as per list of make enclosed with this tender / approved list of HQCECC / HQCELZ / MNRE and make of all items shall be same. |
| 297 | (d) contractor to be provide cable of suitable size for connection to panel through upto ACDB(minimum distance 110mtr ). |
| 298 | (e) Bidder will be provide Trg to MES staff for operation/upkeep of RTS. |
| 299 | (f) Remote Monitoring system shall be provide by the OEM / Bidder and shall be accessible for mobile app (IOS/Android) for each monitoring, SIM charge for the period of compherensive maint deemed to be included in the quoted rate. |
| 300 | (g).The supplier shal provide easy -to-use illustrated installation and operation manual for easy installation and trouble free usage.Manual shall contain complete system details such as array layout,schmatic of the system,working princpal,clear instruction on regular maintenance,trouble shooting of the solar generating system & emergency shutdown procedure.(h) Inverter & PV Panel supplier / OEM shall have an authorized service center / service franchise in the location of installation. |
| 301 | Reduction plant down time:- The contractor shall ensure the plant availability upto 99%.However,the plant availability due to grid outage will be considered only if the same are certified by the competent authority/CE/CWE.Any other outage which are not attributable to the contractor and are certified by department may also be considered. |
| 302 | k)Record shall be maintained by contractorin concultation with deptt for enery generation on daily basis. |
| 303 | Taking down water heaters / Geysers of any capacity for overhauling / serviceing / repairing by opening of base plate, descaling of water taknk, heating element, cleaning of entire geyser, checking & tighting of all internal electric connection, replacement of nut bolt etc, reassembling, refixing, re-installation of water heaters / Geysers to their original position, making all necessary water & electric connections and testing complete all as specified and directed.Note :- (i) Labour for assembling of all old/ serviceable and new parts to make the geyser in serviceable conditionshall include in this items.(ii)Spears parts renewed shall be measured and paid spearately as supply only. |
| 304 | Supply only heating element 1.5 KW (ISI marked) suitable for geyser of 25 litres capacity, horizontal or vertical type any make all as specified and directed. |
| 305 | Supply only heating element 2 KW (ISI marked) suitable for geyser of 50 litres capacity, horizontal or vertical type any make all as specified and directed. |
| 306 | Supply only thermostat, minimum 300 mm long, suitable for any make & type of geyser 25 / 50 litres capacity horizontal or vertical type all as specified and directed. |
| 307 | Supply only indicating lamp LED type for geysers of any type make & capacity all as specified and directed . |
| 308 | S&F in repair PVC connection 15 mm dia with 2 Nos brass coupling, nuts from geyser inlet / outlet, 45 cm length suitable for 15 mm bore GI pipe all as specified and directed. |
| 309 | M&L for preparation of old painted surface of exhaust fan 300 to 450 mm sweep AC 230 volts single phase and applying one coat synthetic enamelled gray / matching coloure with spray machine and rerewriting of MES Nos as approved size of letter all as specified and directed. |
| 310 | Taking down old detiorated, rusted out lived and unsv ceiling fan, supply & fix new ceiling fan 1200 mm sweep, BLDC copper wound motor, AC single phase, 230 volts, white colour complete with fan blade, down rod, canopy and provn of connection with three core flexible copper wire cable of size 1.50 sqmm from ceiling rose to fan, writing of MES Nos as approved size of letter complete all as specified and directed. |
| 311 | M&L for cutting of 80 mm bore CI / DI pipes of following dia sizes in position for insertion of Tees, branches etc. Incl dewatering due to residual water in pipes complete all as specified and directed. |
| 312 | M&L for cutting of 100 mm bore CI / DI pipes of following dia sizes in position for insertion of Tees, branches etc. Incl dewatering due to residual water in pipes complete all as specified and directed. |
| 313 | M&L for cutting of 150 mm bore CI / DI pipes of following dia sizes in position for insertion of Tees, branches etc. Incl dewatering due to residual water in pipes complete all as specified and directed. |
| 314 | Taking up or down 15 mm bore steel water tubing with all fittings / connections, fromwall, ceiling etc complete allas specified and directed by Engr-in-Charge |
| 315 | Taking up or down 20 mm bore steel water tubing with all fittings / connections, fromwall, ceiling etc complete allas specified and directed by Engr-in-Charge |
| 316 | Taking up or down 25 mm bore steel water tubing with all fittings / connections, fromtrenches etc complete allas specified and directed by Engr-in-Charge |
| 317 | Taking up or down 40 mm bore steel water tubing with all fittings / connections, fromtrenches etc complete allas specified and directed by Engr-in-Charge |
| 318 | Taking up or down 50 mm bore steel water tubing with all fittings / connections, fromtrenches etc complete allas specified and directed by Engr-in-Charge |
| 319 | Taking up or down 80 mm bore steel water tubing with all fittings / connections, fromtrenches etc complete allas specified and directed by Engr-in-Charge |
| 320 | S&F 15 mm bore mild steel galvanised iron pipe medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc, fixed to wall / ceiling or laid in floor complete all as specified anddirected by Engineer-in-Charge. |
| 321 | S&F 20 mm bore mild steel galvanised iron pipe medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc, fixed to wall / ceiling or laid in floor complete all as specified anddirected by Engineer-in-Charge. |
| 322 | S&F 25 mm bore mild steel galvanised iron pipe medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc, laid in trenches or laid in floor complete all as specified anddirected by Engineer-in-Charge.Note : Excavation and earth work will be measured and paid for separately. |
| 323 | S&F 40 mm bore mild steel galvanised iron pipe medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc, laid in trenches or laid in floor complete all as specified anddirected by Engineer-in-Charge.Note : Excavation and earth work will be measured and paid for separately. |
| 324 | S&F 50 mm bore mild steel galvanised iron pipe medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc, laid in trenches or laid in floor complete all as specified anddirected by Engineer-in-Charge.Note : Excavation and earth work will be measured and paid for separately. |
| 325 | S&F 80 mm bore mild steel galvanised iron pipe medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc, laid in trenches or laid in floor complete all as specified anddirected by Engineer-in-Charge.Note : Excavation and earth work will be measured and paid for separately. |
| 326 | Deployment of manpower & tools for Drilling & tapping cast iron / ductile iron water mains in position for 15 mm size branch connection complete all as specified & directed by Engineer-in-Charge. |
| 327 | Deployment of manpower & tools for Drilling & tapping cast iron / ductile iron water mains in position for 20 mm size branch connection complete all as specified & directed by Engineer-in-Charge. |
| 328 | S&F 20 mm size Gun metal gate or globe valve \"ISI marked\"with iron wheel head screwed both end for iron pipe all as per latest IS specifications including taking down old valvecomplete all as specified and directed by Engineer-in-Charge. |
| 329 | S&F 25 mm size Gun metal gate or globe valve \"ISI marked\"with iron wheel head screwed both end for iron pipe all as per latest IS specifications including taking down old valvecomplete all as specified and directed by Engineer-in-Charge. |
| 330 | S&F 40 mm size Gun metal gate or globe valve \"ISI marked\"with iron wheel head screwed both end for iron pipe all as per latest IS specifications including taking down old valvecomplete all as specified and directed by Engineer-in-Charge. |
| 331 | S&F 50 mm size Gun metal gate or globe valve \"ISI marked\"with iron wheel head screwed both end for iron pipe all as per latest IS specifications including taking down old valvecomplete all as specified and directed by Engineer-in-Charge. |
| 332 | M&L for Cutting of road (in hard/ dense soil ) for laying of pipe line or repair to pipes / lead joints etc of any size of pipe,depth exe 0.7 metre but not exceeding 01 metre and width 0.6 metre, getting out including forming bottom surface to required level and making good the road by returning filling with excavated material and top 250 mm thick filled with PCC 1:3:6 type C2, including removal of surplus excavated material to a distance n. exc 50 metre complete all as specified and directed. |
| 333 | Drilling/boaring (horizontally) 150 mm to 200 mm bore by penumatic tool or horizontal boaring / drilling machine under the existing road (max. 10 mtr. In width) suitable for passing GI / CI / DI tubing complete all as specified and directed. |
| 334 | S&F DWC Pipe 50 mm, incl taking down complete all as specified and directed. |
| 335 | M&L for Cleaning of HDPE service water tank ofcapacity exceeding 1000 litre, and the connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out the water from the tank and washing internally with water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water) and again draining out the water from the tank and writing the date of cleaning with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge. |
| 336 | Labour only removal of air lock from GI pipe 15 / 20 / 25 mm bore by removing Flot valve and priming with fresh water and reconnecting all connections complete all as specified and directed. |
| 337 | M&L for repairing of leakage of sluice valve of 80 mm to 150 mm Dia, by taking out sluice valve, supply and fix new packing with nut bolts of required size and refixing the same sluice valve in position to make it leak proof all as specified and directed. |
| 338 | Material & labour for replacement of Brocken elbow / tee from 15 mm bore GI water pipe line, by removing old pipe line up to 2.00 metre length, S&F new elbow / tee, including full threaded screw nipple with check nut & socket, refixing GI pipe in same position complete all as specified & directed by Engineer-in-Charge. |
| 339 | Material & labour for replacement of Brocken elbow / tee from 20 mm bore GI water pipe line, by removing old pipe line up to 2.00 metre length, S&F new elbow / tee, including full threaded screw nipple with check nut & socket, refixing GI pipe in same position complete all as specified & directed by Engineer-in-Charge. |
| 340 | Material & labour for replacement of Brocken elbow / tee from 40 mm bore GI water pipe line, by removing old pipe line up to 5.00 metre length, S&F new elbow / tee, including full threaded screw nipple with check nut & socket, refixing GI pipe in same position complete all as specified & directed by Engineer-in-Charge. |
| 341 | Material & labour for replacement of Brocken elbow / tee from 50 mm bore GI water pipe line, by removing old pipe line up to 5.00 metre length, S&F new elbow / tee, including full threaded screw nipple with check nut & socket, refixing GI pipe in same position complete all as specified & directed by Engineer-in-Charge. |
| 342 | Material & labour for replacement of Brocken elbow / tee from 80 mm bore GI water pipe line, by removing old pipe line up to 5.00 metre length, S&F new elbow / tee, including full threaded screw nipple with check nut & socket, refixing GI pipe in same position complete all as specified & directed by Engineer-in-Charge. |
| 343 | Supply & fix new3 HP, 3 phase centrifugal pump has horizontal structure, single stage centrifugal pump featuring 4kW motor power. Centrfugal water pump has wide optional input voltage from AC 220V to 480V, optional input frequency 50Hz and same diameter of inlet and outlet 50mm (2 inches). Horizontal centrifugal pump has advantages of low noise, simple structure and long service life. all as specified and directed by Engr-in-charge. |
| 344 | Supply & fixing a new Compact Air Curtain Door Fresh Fan for Gate EntranceMetal cover with powder coated, compact design easy clean. Remote control or manual switch. Cross flow type air flow. Installation height: 2-3m, size:1.2m. Switch or Remote control andTwo speeds with Metal cabinet & cover,Cross flow type airflow, size 1,200mm/1,500mm and operating voltage 220 Volts, 50Hz, maximum input power 110 W, air Volume 1250 (m3/h), air velocity 8-10.5 (m/s) and noise level 53/54 dB. Product should be certified by OEM all as specified and directed by Engr-in-Charge.Note:- All connected items should be provided by contractor. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |