| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 4 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing. |
| 5 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed. |
| 6 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 7 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 8 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in framed work complete all as specified and directed. |
| 9 | Dismantling of timber fillets rails, posts, rafters, pulins etc under 40 sqcm in setion in any position in unframed work complete all as specified and directed. |
| 10 | Dismantling wall and ceilingboards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 11 | Dismantling wooden boarding (eaves board, rafter etc) of any description fixed in any position with nails. |
| 12 | Dismantling asbestos cement/PVC pipe 50/75/100 mm dia including clampscomplete all as specified and directed. |
| 13 | Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water all as specified and directed. |
| 14 | Taking down chowkats or frames with shutters (without taking of shutters) from the frame n.exc 1.5 Sqm each all as directed |
| 15 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 16 | Taking up or down 15mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 17 | Taking up or down 20mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 18 | Surface dressing n exc 15 cm deep and gettingout in soft / lose soil complete all as specified |
| 19 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of column, wall etc, not exc 10 sqm on plan and getting out in soft/loose soil etc complete all as specified and directed. |
| 20 | Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as specified. |
| 21 | Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as specified. |
| 22 | M&L for earth filling under floor incl spreading levelling & well ramming including watering as required n exc. 25 cm thick. (Note: Earth obtained from item no02 & 03 is reused) |
| 23 | M&L for Hardcore broken stone of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 24 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified. |
| 25 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surfacecomplete all as specified. |
| 26 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 27 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified. |
| 28 | M&L for PCC (1:4:8), D2 using 40 mm graded stoneaggregate as in foundations, sub-base,filling and mass concrete. all as specified and dirceted |
| 29 | M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in sub-bases for floors, complete all as specified and as directed. |
| 30 | Material and labour for 75mm thickcement concrete 1:3:6 type C2 using 20mm graded stone aggregate as in plinth protection finished even and fair without using extra cement complete all as specified. |
| 31 | Material and labour for providing Plain Cement Concrete(1:3:6) type C1 using 20mm graded stoneaggregate as in surface channel and drainall as specified and directed. |
| 32 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends foretccomplete all as specified and directed. |
| 33 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 34 | Use and waste of Form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concretecomplete all as specified and directed. |
| 35 | Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide Where RCC/PCC band in walls, spanning and opening, the formwork soffit complete all as specified and directed |
| 36 | Use and waste ofFormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed |
| 37 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 38 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 39 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed. |
| 40 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) using 20mm aggregate as in slab supported on walls , beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc comlpete all as specified and directed. |
| 41 | Material and labour for 10mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 42 | Material and labour for 6mm to 8mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 43 | Material and labour for Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 44 | M & L for brickwork with subclass \"B\" or locally available best qualityold size bricks, straight or curved on plan exc 6 m mean raduis,built in CM (1:6) complete all as specified and directed. |
| 45 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 46 | M&L for 10 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and Smooth(with out using extra cement) fair all as specified. |
| 47 | M & L 10 mm thick rendering in cement mortar (1:6) on other side of lathing surface finished fair and even complete all as specified. |
| 48 | M&L rendering 15 mm thick cement plaster in two layer Each of 10+5 mm thick on other thanfair faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even. ( Note -W.P.C. shall be measured and paid separetly). |
| 49 | M & L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on one side of lathing in CM (1:4) & water proofing compound mixed with second layer (5mm thick) @ 3% finished fair and even complete all as specified.( Note -WPC shall be measured and paid separetly . ) |
| 50 | Material and labour for Rendering/plastering, 15 mm thick (10mm + 5mm)in two layers in cement mortar (1:4) on any face of brick walls or concrete surfaces, using WPC, surfaces finished finished even and smoothwithout using extra cement complete all as specified. (WPC measured separately). |
| 51 | Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 52 | M&L Non Skid ceramic tiles colour7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including15 mm thick screed bed or bedding layers in cement mortar 1:6 as specified . |
| 53 | Material and labour Non skid Ceramic tiles7 to 8 mm thick (square/ rectangular) , area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including15 mm thick screed bed or bedding layers in cement mortar 1:6completeall as specified and directed. |
| 54 | Material and labour Non skid Ceramic tiles7 to 8 mm thick (square/ rectangular) , area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 sqm as in skirting including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 55 | M&L of Glazed ceramic coloured tilesin vertical surface size 350 x 250 x 7mm/450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 56 | M&L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and incl screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6.complete all as spd and directed. |
| 57 | M&L machine cut kota stone slab flooring 20-25mm thick in riser / skirtingover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achive the mirror polishing on kota stone to give the high gloss finished over and incl screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6.complete all as spd and directed. |
| 58 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 59 | Supply and fix Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 60 | S&F Steel work in Roof trusses (framed), trussed,purlins, crane gantries, rails ,posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats nuts bolts plates (plain or chequered) etc. complete all as specified and directed. |
| 61 | Supply and fix Steel work in tubular trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-210 complete all as specified and directed. |
| 62 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 63 | S&F Bands, straps, supports or stays for frame of evaes board, rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 64 | S & F for GI wire netting 0.71 mm dia and 12 mm mesh lathing to wood or metal studding joints etc in walls ceiling stanchion,beams etc included all laps cutting and wastes |
| 65 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 66 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 2 Nos steel tower bolts 100mm long peg stay complete without glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 67 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified. |
| 68 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 105X60mm for door and window frames with one or more rebates includinghinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 69 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 125X60mm for door and window frames with one or more rebates includinghinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 70 | M & L for second class harwood in scantlings timber framed and fixed for wrought in section complete all as specified and directed. |
| 71 | Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue, pinned at joints. |
| 72 | Material and labour Cement concrete (1:3:6), type C-0 using 12.5mm graded stone aggregate as in filling of steel chowkhatsand concrete for fixing of holdfast including necessary form work complete all as specified. |
| 73 | M & L for second class harwood fillets square, rectangular or tringular in section wrought screwed with nails exc 6 sqcm and n. exc 13 sqcm complete all as specified and directed. |
| 74 | S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides , covered with decorative face laminate on edges all as specified and directed |
| 75 | S & F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges all as specified and directed |
| 76 | S&F 2nd class hard woodglazed andskeleton door shutters 35 mm thick open rebated and prepared to receive glass, guage etc (withoput sash bars), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.20(a) complete all as specified & directed. |
| 77 | Material and labour small article of 2nd class hardwood, such as hinge blocks, door and window stops, articles not exceeding 200 cubic centimeter each and fixed with steel screws complete all as specified. |
| 78 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron)for Door shutters with frame, Three track sliding windows ( 2 x glazed & 1 x Gauzed shutter), ventilator & cup boardincluding necessary jointing cleats, screws etc &Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws fixed complete all as specified & directed. |
| 79 | S & F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2020). |
| 80 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified. |
| 81 | Supply and fixStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.0mm and fixed with stainless steel wire staples complete all as specified. |
| 82 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified. |
| 83 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square exc 0.5 sqm in each pane complete all as specified and directed |
| 84 | Supply and fix 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified. |
| 85 | Supply and fix Aluminium anodised,200mmbarrel tower bolts of extruded section and fixed complete all as specified. |
| 86 | Supply and fix aluminium handles, fabricated type, anodised 125 mm long fixed with screws complete all as specified and directed. |
| 87 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 88 | S&F 150 mm extruded aluminum alloy handles, cast type, anodized complete all as specified and directed. |
| 89 | S&F 100mm MS Butt hinges, medium weight, cold rolledcomplete all as specified and directed. |
| 90 | S&F 25 mm dia and 1mm thick MS chromium platedcurtain rods including fancy type side brackets end knobs and fixed with PVC rawl plugs & steel screws as in repairs etc all as specified and directed . |
| 91 | S&F for in repair vitreous china wash basin, white, counter top, size 560 mm x 461 mm ovel shape including waste coupling but excluding taps, waste chain and plug and porcelain stopper complete all as specified and directed.Make: Hindware Cat Part No 10017 or equivalent as per make approved list. |
| 92 | Supply and fix in repair vitreous china Squatting pan, \"Orissa\" pattern, Size 580 X 440mm ,with integral foot rests (excluding flushing ciestern and flush pipe) incl necessary lime concrete and 100 mm bore cast iron \"P\" trap with 550 to 600mm long neck for connecting WC to branch piece with cement joints complete all as specified & as directed . |
| 93 | Supply & Fixed inrepairsVitreous china wash down water closet pan ( pedestal pattern ) , whitewith P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 94 | S & F in repairsPVC valveless,syphonic action type,low level flushing cistren 10 ltr capacity ISI Marked incl all acessories and 32mm dia PVC flush / discharge pipe incl float valve, inlet complete all as specified. |
| 95 | Supply and fix in repairVitreous China urinals, bowl type urinal flat back large size of 465mm x 355mm x 265mm white (minimum), with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 96 | Supply and fix PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 97 | Supply and fix Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 98 | Supply and fix 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass as in repair complete all as specified. |
| 99 | Supply and fix 15mm bore stop valves/angle valveof cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) fixed in repairs complete all as specified. |
| 100 | S&F in repairs 15mm bore bib taps fancy type, long neck, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule including accessories complete all as specified and directed. |
| 101 | S&F as in repairs,15 mm bore, Pillar taps, fancy type, cast copper alloy, withcapstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixedcomplete all as specified. |
| 102 | S&F of Corner /glass shelf complete all as specified and directed. |
| 103 | S&F 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 104 | Supply and fix 110mm diaPVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 105 | Supply and fix 75mm diaPVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified. |
| 106 | Supply and fix 110mm dia PVC (SWR) bend suitable for pipe complete all as specified. |
| 107 | Supply and fix 75mm bore PVC (SWR) bends any radius, fitted with oval access door complete all as specified. |
| 108 | Supply and fix 110mm bore PVC (SWR) junction, single T equal or unequal with or without door access complete all as specified. |
| 109 | Material and labour PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified. |
| 110 | Supply and fix in GI tube 15 mm dia (ISI Marked) medium grade galvanised with all fittings laid in floors /wall etc. complete all as specified and as directed. |
| 111 | Supply and fix in GI tube 20 mm dia (ISI Marked) medium grade galvanised with all fittings laid in floors /wall etc. complete all as specified and as directed. |
| 112 | Refixing of 15mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.Note: Old serviceable GI tube obtained vide respective item above mentioned shall be reused. |
| 113 | Refixing of 20mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.Note: Old serviceable GI tube obtained vide respctive item above mentionedshall be reused. |
| 114 | Cutting chases, pinning in, making good to facing where required and pointed in cement mortar 1:3 and making good cutting exceeding 10 cm girth complete all as specified and as directed. |
| 115 | Supply and fix in repairs gun metal gatevalves, with iron wheel head, screwed both ends for GI pipe 20 mm bore and fixedcomplete all as specified and directed. |
| 116 | Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick high Pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI systtem duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid all as specified and directed. Make : Everest Industries Ltd or equivalent as per IS 14862 all as specified and directed. |
| 117 | M&L preparation of new plastered surface of walls andapplying wall care putty of 1 mm thickness over prepare plastered surface with the surface even and smooth complete all as specified. |
| 118 | Material and labourpreparation of new plastered surface of walls and applying two coat of oil emulsion distemper over one coat of primer on wall complete all as specified. |
| 119 | M&L for prepration of new or priviously untreated surface and applying two coat of oil bound distemper over a coat of primer on wall complete all as specified and directed. |
| 120 | Material and labour for preparation of old decorated plastered or unplatered wall surface including brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss and efforescent salts, trading oil and greasy spots etc and applying one coat of oil bound istemper with use roller complete all as specified and directed. |
| 121 | Material and labour for preparation of new or previously untreated wall surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer aoolied @0.90 litre /10 Sqm over new surfacescomplete all as specified and directed. |
| 122 | Material & Labour for complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as specified. |
| 123 | Material and labour preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 124 | Material and labour for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 125 | E & M Division items |
| 126 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 127 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 128 | Taking out old U/s XLPE cable of any size/type taking out of olf bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 129 | Taking out old U/s GI PIPE of 25/32mm size/type including all GI fittings etc complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 130 | Dismantling of U/s GI pipe of size 40 mm bore complete all as specified and directed. |
| 131 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 132 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 133 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 134 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 135 | M&L for point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 136 | M&L for point wiring with FRLSH stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 137 | M&L for point wiring with FRLSH stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 138 | S&Fswitch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 139 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 140 | S&Fswitch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 141 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 142 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 143 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 144 | M&L for submain wiring with two single core 1.5 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSHH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed.Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 145 | M&L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSHH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 2.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 146 | M&L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSHH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 147 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 148 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 149 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 150 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook includingincluding taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed. |
| 151 | S&F plastic body exhaust fan300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 152 | S&F bldg security light, LEDluminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. |
| 153 | S&F bldg security light, LEDluminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements completeall as per directed by Engr- in – charge. |
| 154 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 155 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 156 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 157 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 158 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 4 way double door with 200 Amps rated bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 159 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 160 | S&F MCB TPN of capacity 63 Amps 4 pole,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 161 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 162 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 163 | Taking out old existing earthing and M&L for new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 164 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 165 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 166 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 6 sqmm 2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 167 | Material & labour GI tube light grade 25 mm bore for protection ofcable complete all as specified and directed. |
| 168 | Material & labour GI tube light grade 40 mm bore for protection ofcable complete all as specified and directed. |
| 169 | M&L 100mm thickPCC 1:3:6 type C2 using 40mm graded crushed stone aggregate for flooring complete all as specified and directed. |
| 170 | S&F gun metal gate valve 25mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 171 | M&L for steel water tubing 25mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 172 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 173 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 174 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 175 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 176 | M&L for bricks sub-class \"B\" laid in trenches for cable protection complete all as specified and directed. |
| 177 | M&L for cutting of existing GI pipe line 25mm dia for inserting Tee and reducer etc for taking 25mm dia branch pipe including fittings complete |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail