Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-02-2026 | BOQ | BOQ | 21-02-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings any thickness, complete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws asspecified. |
| 3 | S&F Pre-painted galvalumealuminum zinc coating GIbased Plain steel sheet0.50mm thick of anycolour having tensilestrength of 550 Mpa as inroof covering/cladding towall, fixed with selftapping screws asspecified. |
| 4 | S&F 0.71mm thick plain, aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length andgirth as fixed)all as directed. |
| 5 | Taking down chowkhats or frames with shutter (without taking off shutter from the frame)exe 1.50but n. exc. 4sqm in each complete all as specified & directed. |
| 6 | Taking down chowkhats or frames with shutter (without taking off shutter from the frame) n. exe 1.50 sqm in each complete all as specified & directed. |
| 7 | S&F pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm x 60 mm, profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers including PCC (1:2:4) type B-1 for filling of hollow section complete all as specified and as directed. |
| 8 | S&F pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm x 60 mm, profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers including PCC (1:2:4) type B-1 for filling of hollow section complete all as specified and as directed. |
| 9 | S&F 35mm thick 2nd class hard wood Glazed andskeletonshutters, open rebated and preparedto receive glass, stainless steel gauze, etc. (withoutsash bars), edges offraming plain, chamfered orrounded. fitted withcut and mitred beadsfor securing glass, etc.; sizes of me-mbersof shutters asspecified inSSR PartI, Section 8, clause8.24(a); supplied andfitted to chowkats complete all as specified and directed. |
| 10 | S&F 35 mm thick, 2nd class hardwood plain, Flush shutters,solid core construction, with blockboard core and plywoodface panels, commercialtype on both sides complete as specified and directed. |
| 11 | S&F mild steel work as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 12 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed. |
| 13 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing, complete all as specified and directed. |
| 14 | S&F Anodised aluminum section powder coated (minimum thickness of powder coating 50 micron) in partition / frame for door, shutters, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco).Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment.Cost of other consumables required for the item shall be deemed to be included in the quoted rate.However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper will be measured and paid separately under respective items. |
| 15 | M&L for anodised aluminium window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre (minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws etc complete all as specified and as directed. |
| 16 | S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m (minimum thickness of powder coating 50 micron) including necessary joining cleat glazing clips, rubber neoprene packing handle 2 Nos in each door, hinges, anodised aluminium snap beading screw etc. including powder coating of minimum 50 micron thickness complete all as specified and as directed.. |
| 17 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 18 | S&F 12mm Prelaminated particle board, interior grade, prelaminated both sideswith decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed. |
| 19 | S&F 100 mm size, butt hinges, extruded medium weight cold rolled mild steeletc complete all as specified and as directed. |
| 20 | S&F 150mm size, aluminium anodised handle,fabricated type complete all as specified and as directed.. |
| 21 | S&F 100mm size, aluminium anodised handle,fabricated type complete all as specified and as directed.. |
| 22 | M&L 150 mm long mild steel, barrel tower bolts of extruded section etc complete all as specified and as directed. |
| 23 | S&F 100 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic filmcomplete all as specified and as directed. |
| 24 | S&F Mild steel sliding door bolts,250mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed. |
| 25 | S&F in repairs MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete |
| 26 | Dismantling water tanks and removing to store exc 500 & n.exc 1000 Ltrs |
| 27 | S&F 500 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe incl 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minimum weight 20 mm - 210 gms) complete all as specified and as directed. |
| 28 | S&F 1000 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minimum weight 20 mm - 210 gms )complete all as specified and as directed.S&F in repair 1000 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minimum weight 20 mm - 210 gms )complete all as specified and as directed. |
| 29 | S&F 15mm bore ball brass valves high pressure, with polythene float & fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 30 | S&F 15mm bore ball brass valves high pressure, with polythene float & fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 31 | S&F 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 32 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15cm thickness (below or above ground level) removing rubbish off the premises etc complete all as directed. |
| 33 | M&L for PCC 75mm thick 1:3:6 type C-2thick ( 40mm graded aggregate) thick as in plinth protectionfinishing cement concrete surface even & fair whthout using extra cementcomplete all as specified and directed. |
| 34 | S&F in repairs curtain rails, mild steel, aluminium alloy chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed. |
| 35 | M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 36 | M&L for TMT bars 6 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 37 | S&F3 mm thick sheet glass ordinary quality and glazing with oil putty in squareexc 0.5 sq.m. each pane complete all as specified and directed. . |
| 38 | S&F 4.8 mm thick sheet glass ordinary quality and glazing with oil putty in squareexc 0.5 sq.m. each pane complete all as specified and directed. |
| 39 | S&Fstainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 40 | S&F 150 mm Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed to door complete all as specified and as directed |
| 41 | Demolition and breaking up to 150mm bore drain pipes (SGSW/AC/RCC) set in cement mortar including cement concrete bedding and removal of debris/rubbles etc to a distance not exceeding 50m complete all as specified and as directed. Note : Necessary excavation and earth work shall be measured and paid seperately. |
| 42 | S&F 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete as specified and directed. |
| 43 | S&F 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in trenches complete as specified and directed. |
| 44 | S&F 110mm bore PVC (SWR) bends of any radius complete as specified and directed. |
| 45 | S&F 75mm bore PVC (SWR) bends of any radius complete as specified and directed. |
| 46 | S&F 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete as specified and directed. |
| 47 | S&F 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in trenches complete as specified and directed. |
| 48 | S&F PVC (SWR)junction single, (Single T) equal or unequal, 110 mm bore complete all as specified and directed. |
| 49 | S&F PVC (SWR)junction single, (Single T) equal or unequal, 110 mm bore complete all as specified and directed. |
| 50 | S&F PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 51 | S&F 110 mm bore, PVC (SWR) vent cowlfixed with solvent cement complete all as specified and as directed. |
| 52 | Demolition of reinforced concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, removing rubbish off the premises etc complete all as directed. |
| 53 | M&L for PCC (1:3:6), type C2 (using 40mm graded stone aggregates) as in surfaces channels and drains incl necessary formwork complete all as specified and directed. |
| 54 | M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 55 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed. |
| 56 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. |
| 57 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 58 | M&L for brick work with old size flyash bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 59 | M&L for brick work with old size flyash bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 60 | M&L for RCC (nominal mix) Type B1 (1:2:4) (20 mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.(Note: Reinforcement shall be measured & paid separately) . |
| 61 | M&L for RCC (1:2:4) (nominal mix) Type B1 (20 mm graded agg) in column, pillars, piers, post and struts complete all as specified and as directed. |
| 62 | Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surface of concrete complete all as specified and as directed. |
| 63 | Use and waste of form work to sides of concrete foundations, footings bases of columns below GL and similar work, rough finished surfaces of concrete complete all as specified and directed. |
| 64 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions etc rough finished flat surface of concrete complete all as specified and as directed. |
| 65 | Taking down cement plaster or cement lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris as directed including necessary scaffoldings etc complete all as directed. |
| 66 | M&L for rendering 10 mm thick wall on other than fair faces of brick work or concrete surfaces in cement mortar in (1:6) andfinished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 67 | M&L for 40 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in sub base finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 68 | M&L for 100 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in sub base finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 69 | M&L for 38 mm wide aluminium dividing strips, 1.5mm thick, inserted inposition, conform to design complete all as specified and directed. |
| 70 | M&L for rendering 15mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound weight of cementas per manufacturer\"s instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. ( Note : WPC shall be measured and paid separately) |
| 71 | Supply only water proofing compound for external plaster complete all as specified and directed. |
| 72 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of cement primer on wall complete all specified and directed. |
| 73 | M&L for preparation newly plaster surfaces of wall, chajja facia etc with putty 1-2mm thick and applying two coats of 100%premium Acrylic emulsion paint having VOC less than 50 gm/litre and UV resistant as per IS-15489=2004 alkali and fungal resistant exterior paint of required shed (company depot limited)with silicon additives 1/43 litres/10 Sqm over and including primer applied 0.90 litres/.10 sqm over new surfaces using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 Mtr, the spray machine whould be of reputed manufacturer with pro guaeds technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and acessories complete all as specified and directed. |
| 74 | M&L for Complete removal of existing treatment and treating from walls and applying 1-2mm thick wall putty and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surface even and smooth complete all as specified and directed |
| 75 | M&L for preparing of new plastered surfaces of walls &applying plaster of paris puttyof 1 -2 mm thickness over plastered surface toprepare the surface even and smooth etc and applying two coats of oil bound distemper etc complete all as specified and directed. |
| 76 | M&L for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 77 | M&Lfor 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 78 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 79 | M&L for PCC (1:2:4),type B0 ( using 12.5 mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 80 | M&L for precast RCC (1:2:4), type B1 (using 20 mm graded stone aggregates) as in landings, cover slabs of manhole, septic tank etc, and similar articles with plain faces set in cement mortar 1:4 including necessary formwork, moulds etc and incl taking out/removal of existing unserviceable cover slab from manhole /septic tank complete all as specified and as directed.Note : Reinforcement shall be measured and paid separately. |
| 81 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed. |
| 82 | M&L for 15 mm thick, screed bed or bedding layer of cement mortar 1:6,for laying floor finishes as directed. |
| 83 | M&L for 20 mm thick, screed bed or bedding layer of cement mortar 1:6,for laying floor finishes as directed. |
| 84 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding0.18 sqm but notexceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and directed. |
| 85 | M&L for non skid ceramic colouredtiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed. |
| 86 | M&L for rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces as in vertical surfaces for laying tiles as directed. |
| 87 | M&L for coloured 450x350x7-8 mm thick glazed ceramic tileson vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thickbacking coat in cement mortar (1:4) , complete all as specified and directed. |
| 88 | M&L for Machine cut kota stone slab flooring 20-25 mm thick over 15mm thick cement screed bed in CM 1:6laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 89 | M&L for Machine cut Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick cement screed in CM 1:4 and jointed with j grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 90 | Dismantling wall and celling board (fibre, pulp, insulation etc) any thickness including cover fillets as directed. |
| 91 | S&F aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frameincluding providing two coats of white wash complete all as specified and as directed. |
| 92 | Taking up or down 15 mm bore steel tubing and connections, including removal to store complete all as specified and directed. |
| 93 | Re-fixing 15mm bore old steeltubes,with all fittrings and fixed, to walls and ceilings or laying in floors |
| 94 | S&F steel tubes, galvanised 15 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete as specified and directed including taking down old one. |
| 95 | Taking up or down 20 mm bore steel tubing and connections, including removal to store complete all as specified and directed. |
| 96 | Re-fixing 20mm bore old steeltubes,with all fittrings and fixed, to walls and ceilings or laying in floors |
| 97 | S&Fsteel tubes, galvanised 20 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete as specified and directed . |
| 98 | S&Fsteel tubes, galvanised 15 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete as specified and directed . |
| 99 | S&F in repairs Vitreous china wash basin, white flat back, size 550mm x 400mm with brackets, excluding pillars cock 15mm bore CP, PVC connection of 450mm long including PVC (HDPE) 32mm bore waste pipe, brass couplings 32mm CP etc complete all as specified and directed. |
| 100 | S&F in repairs cromium plated Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks & fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 101 | S&F cromium plated Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks & fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 102 | S&F repairs 15mm bore dia Stop cock cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 103 | S&F 15mm bore dia Stop valves fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 104 | S&F grating doom 125mm dia of PTMT (Minimum weight 40gms) complete all as specified and as directed. |
| 105 | S&F 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed. |
| 106 | M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:-(a)Taking down existing old tarfelt, bituminous compoundincluding cleaning & removing debris to a distance exc 100 m n.exc.250m.(b) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) finished even and smooth.(c) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (d) M&L for 20 mm thick screed bed in cement mortar 1:4 finished even and smooth.(e) Preparing & cleaning of fully dried cement plastered surface.(f) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384.(g) A layer of APP based polymeric membrane3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric(weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.(h) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:-Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab. |
| 107 | S&F in repairs 600 x 450mm beveled edged mirror or selected quality glass mounted on 6mm thick AC building board or commercisl plywood and fixed to wooden plugs with chromium plated brass screws and cup and washers. |
| 108 | S&F 600 x 450mm beveled edged mirror or selected quality glass mounted on 6mm thick AC building board or commercisl plywood and fixed to wooden plugs with chromium plated brass screws and cup and washers. |
| 109 | S&F in repairs, stop valves, 15mm bore cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed bhoth ends for iron pipe or for unions as specified and directed. |
| 110 | S&F in repairs 15mm bore PVC connection pipe 450mm longh with PTMT nuts at both ends. |
| 111 | S&F in repairs, 10 Litres capacity PVC valveless syphonic action type, flushing cistern (ISI marked), low level with inlet. Ball valve, float bracket & flush pipe complete all as specified& directed. |
| 112 | S&F in repairs 15mm bore Bib Taps, Chromium plated cast copper alloy with crutch or butterfly handle, screwex for iron pipeor for brass ferrule and fixed. |
| 113 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 114 | S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) with seat cover white with \"P\" or \"S\" trap, including and flushing pipe etc complete including making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with existing specifications as specified (excluding fixing bolts, flushing cistern and flush pipe) |
| 115 | S&F Vitreous China squatting pan, `Orrisa\" pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern & flush pipe) incl setting the trap and pan in cement mortar (1:3:6) all round and \"P\" or \"S\" Trap, complete all as specified and directed. |
| 116 | S&F curved shape urinal partition with 8mm thick frosted glass (Size 900mm x 450mm) Jaguar Cate Part No : 1110-UC, JSE-CHR-110UC450X or equivalent model in Make : Parryware, Cera, Prayag. |
| 117 | S&F counter top WHB vitreous china oval type coloured with brackets fitted on granite counter top size 560x400x205mm Cera Cate Part No : S2030103or equivalent model in Make : Parryware, Jaguar, Prayag. |
| 118 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 119 | S&F 15mm dia two way bib cock CP Parryware Cate Part No : G3034A1or equivalent model in Make : Parryware, Jaguar, Kohler. |
| 120 | S&F 15mm dia angular stop cock cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 121 | S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) |
| 122 | S&F corner shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) |
| 123 | S&F urinal port flow with integrated sensor size 295x325x575mm including spreader hindware Cat Part No 60021or equivalent model in Make : Parryware, Cera, Prayag. |
| 124 | S&F parryware single peace white colour EWC size 620x350x725mm Parryware Cate PartNo : C8852or equivalent model in Make : Cera, Prayag, Hindware. |
| 125 | S&F parryware standard towel rack Cat Part No T6008A1 or equivalent model in Make : Plywood, Prayag, Jaguar. |
| 126 | S&F in repairs Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern omplete all as specified and as directed. |
| 127 | S&F in repairs 32mm diaWaste coupling of PTMT (half or full threaded) (Minimum weight 32mm45gms/40mm-60 gms) complete all as specified and directed. |
| 128 | S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm |
| 129 | S&F in repairs, Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) |
| 130 | S&F rolled mild steel work in roof trusses (framed), trussed, purlins crane gantries , rafts and fastening and heavy brackets framming (beams tee,angle channel and or flat sections) including distance pieces, cleat nut bolts etc quality confirmingto Fe-290 (Gde E-165)as specified and as directed. |
| 131 | S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, steel conforming to Fe 410-W (Gde-E-250) Quality Acomplete all as specified and as directed. |
| 132 | S&F Mild steel screw bolts 5mm to 10mm dia (machine made) with hexagonal or square heads at one end screwed the other, or screwed both to be fitted with washers and one hexagonal or square nut, not exc 5 cm long coomplete all as specified and directed. |
| 133 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying twocoatsof synthetic enamel paint over acoat of red oxide primer complete all as specified and directed by Engr-in- charge. |
| 134 | Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and as directed. |
| 135 | Dismantling of framed timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 136 | Dismantling of timber boarding of any description, fixed in any position with nails complete all as directed. |
| 137 | M&L for 2nd class hardwood, scantlings, wrought, timber fixed, complete as specified and directed. |
| 138 | S&F 25 mm thick 2nd class HW Boarding, supplied & fixed with nails in any situation (except flooring and skirting) Planed one side and edges tongued and grooved or rebated |
| 139 | S&F Second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails, cross sectional area exc 6and n.exc 13 Sqcm as specified and directed. |
| 140 | M&L for preparing of new wooden surfaces of any description , over 10 cm width or girthand applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 141 | M&L for preparing new wood & wood based surfaces of any descriptions but not exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete as specified. |
| 142 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 143 | Taking down old unserviceableMCB DB any type complete all as specified and directed. |
| 144 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store for safe custody. |
| 145 | M&Lfor concealed point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core FRLSH PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers including cutting chases and making good by using cement mortar 1:4 complete for one light / fan point / call bell complete. |
| 146 | All as per Item No.145here in above but for One 2/3 pin socket outlet 5/6Amps on independent board |
| 147 | All as per Item No.145here in above but forOne 2/3 pin socket outlet 5/6 Amps on the same board with other switches. |
| 148 | All as per Item No.145here in above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm |
| 149 | All as per Item No.145here in above but for one switch socket combination 15/16 Amps on independent board with cable 4 sq mm size and earth wire 4 sqmm |
| 150 | S&F modular switch 1 way 6 A, 1 Module ISI marked complete all as specified and as directed. |
| 151 | S&F modular socket 6-A, 2/3 Pin combined 2 module ISI marked complete all as specified and as directed. |
| 152 | S&F modular socket 6 A/16 A, 2/3 Pin combined 2 module in existing location, complete all as specified and as directed. |
| 153 | S&F modular switch 1 way 16 A, 1 Module ISI marked complete all as specified and as directed. |
| 154 | S&F surface mounting LED edgelit slim round downlighter made of PDC AL with huge efficient LED s and glare free opal diffuser, IP20 including all the accessories needed for its installation complete all as specified and directed. |
| 155 | S&F MCB Distribution board TPN 4 Way for mountingSPN/ SP/TPN/TP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed. |
| 156 | S&F MCB Distribution board TPN 8 Way for mountingSPN/ SP/TPN/TP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed. |
| 157 | S&F in repair of MCB Distribution board SPN 12 Way for mountingSPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed. |
| 158 | S&F in repair miniature circuit breaker (MCB) 415 Volts, 10KA \"C\" curveTPN 63 AMP in the DB complete with connection, testing and commissioning all as specified and directed. |
| 159 | S&F in repair 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 40 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 160 | S&F in repair miniature circuit breaker (MCB) SP, 240 Volts,6 to 32 Amps, \"C\" Series, 10KA capacity complete all as specified and directed. |
| 161 | S&F miniature circuit breaker (MCB)SPN 6 to 32 Amps\"C\" Series 10 KA 240 volts complete all as specified and directed. |
| 162 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground levelwith the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed. |
| 163 | S&F modular fan regulator, 120 W, 2 modules complete all as specified and as directed. |
| 164 | S&F angular/batten holderPVC/Polycarbonate suitable for batten fittings including oneLED Lamp of 9W of complete all as specified and directed. |
| 165 | S&F LED light fitting mirror type with high ouput diffuser 2 feet, 10 watts 220 volts AC decorative type with aliminium housing with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable of suitable size complete all as specified and directed. . |
| 166 | S&F inverter type LED batten (1.2M) made of extruded aluminum housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 18/20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. |
| 167 | S&F Recess mounted 2x2 ceiling light 42 Watt deep drawn CRCA housing with higher power LED Seamless front frame with flat white hight transmission acrylic cover all as specified and directed. (Make : Havells Cat No PLANO2X2PLR42WLED865S or equivalent model in make Crompton/Phillips/Bajaj) |
| 168 | S&F Ceiling rose surface PVC, 3 terminals 65x50mm ISI marked complete all as specified and as directed. |
| 169 | S&F 35 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed. |
| 170 | S&F Bldg light bracket fabricated out of GI Tubing light grade 32 mm bore Bend to the shape as directed and of length 1.5 mtrcomplete with mounting MS clamp of flat iron size 40X5mm of suitable length 02 pairs incl nut bolts etc of suitable size, including taking down old corroded one all as specified and directed. |
| 171 | M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size,fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor(FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed.Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets. |
| 172 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 35 Sqmm, 3.5 core stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 173 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 174 | Returning filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 175 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level n. exc. 1.5 metre above the starting point complete all as specified and directed. |
| 176 | M&L for clear sand cushioningfor protection of cable complete all as specified and directed. (only punned down thickness to be measured) |
| 177 | Supply and laying well burnt bricks, sub class \"B\" bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed. |
| 178 | Boring of holes horizontal for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed.Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate. |
| 179 | S&F 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 180 | M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLHSPVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size ofbrass screws suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed. |
| 181 | All as per Item No.180here in above but for One 2/3 pin socket outlet 5/6Amps on independent board |
| 182 | All as per Item No.180here in above but forOne 2/3 pin socket outlet 5/6 Amps on the same board with other switches. |
| 183 | All as per Item No.180here in above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm |
| 184 | S&FSwitch piano, flush type, single pole, one way switch5 Amps ISI marked complete all as specified and as directed. |
| 185 | S&F Switch socketcombination 2 in 1,5 Amps flush type, ISI marked complete all as specified and as directed. |
| 186 | S&F socket outlet, 2 in 1, 3 pin, 5 Amps, 240V bearing ISI marked complete all as specified and as directed. |
| 187 | S&F switch socket out let combination multipurpose 3/5 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed. |
| 188 | S&F LED fitting 1x18 watts, 220volts AC decorative box type with driver and of aluminium housing, holder LED tube light conncting up to 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 189 | M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing caping of suitable size,fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor(FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed.Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets. |
| 190 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. |
| 191 | Supply and layingun-reinforced precast concrete cable cover , class LV, type -1, flat of size 250x150x40mm, used for power cables upto and including 11 KV with minimum breaking load capacity upto 200kg as per IS: 5820:1970, complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail