| 1 | Excavation in decomposed or soft rock with or without blasting including disposal of the samelead upto 50 m and lift upto 1.50 m. |
| 2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 3 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 4 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:a) Foundations and plinth |
| 6 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 7 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild steel |
| 8 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Column, pillars, posts and struts etc. |
| 9 | b) Lintels, beams, girders, bressumers and cantilevers etc. |
| 10 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas |
| 11 | d) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 12 | Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 13 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 14 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 15 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 16 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 17 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 18 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 19 | Providing approved best available local wood (Class - B II) work in frames of doors,windows clerestory windows and other frames, wrought framed and fixed in position. |
| 20 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.a) 38mm thick best available local wood class - B I |
| 21 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. a) Ornamental grill. |
| 22 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 23 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 24 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 250 x 10 mm |
| 25 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm |
| 26 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 27 | Pre-cast terrazzo tiles 20 mm thick with marble chips of sizes upto 6 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry including rubbing and polishing complete with tiles of : a) Light shades using white cement |
| 28 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall. |
| 29 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 30 | Applying priming coat consisting of a mixture of red lead, white lead and double boiled linseed oil in the ratio of 0.7 Kg : 0.7 Kg : 1 Litre on wood work complete. |
| 31 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 32 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 33 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 34 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 35 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore |
| 36 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 15 mm nominal bore |
| 37 | b) 20 mm nominal bore |
| 38 | Providing and fixing brass bib cock of approved quality.a)15 mm nominal bore |
| 39 | Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore |
| 40 | Sintex |
| 41 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan |
| 42 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC.a) 250 x 130 x 30 mm |
| 43 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 44 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia |
| 45 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.a) Ordinary Soil |
| 46 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 47 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in a) Foundations and plinth |
| 48 | b) Walls including attached buttresses, pilasters and their caps andbases and string courses etc. up to floor two level. |
| 49 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 50 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 51 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel |
| 52 | Centring and shuttering including strutting proping etc. and removal of form work for: b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 53 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 54 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes |
| 55 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design. a) 100 mm dia SW pipes |
| 56 | Point wiring in PVC conduit, with modular type switch.Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm.FR PVC insulated copper conductor single core cable etc. as required.Group A |
| 57 | Circuit/sub-main wiring in PVC conduit :- Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug). |
| 58 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (for ckt wiring). |
| 59 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire(for power point). |
| 60 | S/F PVC conduit :-Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 61 | 32 mm |
| 62 | S/F modular type switch/socket :-Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 Amps Switch |
| 63 | 15/16 Amps Switch |
| 64 | 3 Pin 5/6 Amps Socket |
| 65 | 6 Pin 15/16 Amps socket outlet |
| 66 | S/F modular boxes, Base & Cover Plate:- Supplying and fixing following size/module GI box along with modular base and cover plate for modular switch in recess extr as required. 1 or 2 module (75 mm x 75 mm) |
| 67 | S/F modular type electronic fan regulator :-Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 68 | S/F modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate etc. as required. |
| 69 | S/F light plug point modular type accessories :-Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connection,painting etc. as required.(For light plugs to be used in non residential buildings). |
| 70 | S/F power plug point modular type accessories:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 71 | ITC fluorescent fitting directly on surface :- Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types,complete with all accessories and tube etc. directly on ceiling/wall,including connection with 1.5 sq. mm FR PVC insualted,copper conductor,single core cable and earthing etc. as required. |
| 72 | ITC ceiling fan :-Installation, testing and commissioning of ceiling fan including the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insualted,copper conductor,single core cable and earthing etc. as required. |
| 73 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required. Upto 450 mm sweep |
| 74 | S/F call bell/buzzer :-Supplying and fixing call bell/buzzer suitable for single phase , 230 volts, complete as required. |
| 75 | S/F steel conduit :- Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 76 | 25 mm |
| 77 | Wiring in existing conduit :-Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm |
| 78 | 2 x 1.5 sq. mm |