| 1 | Providingand fixingaluminiumdie cast body tubular typeuniversal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 2 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 3 | 250x16 mm |
| 4 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 5 | 200x10 mm |
| 6 | 150x10 mm |
| 7 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 8 | 125 mm |
| 9 | 100 mm |
| 10 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 11 | Twin rubber stopper |
| 12 | Providing and fixing factory made uPVC door frame made of uPVC extrudedsectionshavinganoveralldimensionasbelow(tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer\"s specification and direction of Engineer- in-charge |
| 13 | Extruded section profile size 42x50 mm |
| 14 | Providing and fixing to existing door frames. |
| 15 | 24 mm thick factory made PVC door shutters made of styles cleats. The shutter frame filled and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mmhavingwallthickness1.0mmandstainlesssteel screws. The styles of the shutter reinforcedby inserting galvanised M.S. tube of size 20x20 mm and 1mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer- in-charge. (For W.C. and bathroom door shutter). |
| 16 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 17 | 40 mm thick with 20 mm nominal size stone aggregate |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 19 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 20 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 21 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 22 | Old work (one or more coats) |
| 23 | Removing white or colour wash by scrapping and sandpapering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 25 | One or more coats on old work |
| 26 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 27 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 28 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 29 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 30 | Renewing glass panes, with wooden fillets wherever necessary: |
| 31 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 32 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 33 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 34 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 35 | Of area 3 sq. metres and below |
| 36 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 37 | 15 mm nominal bore |
| 38 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 39 | 15 mm nominal bore |
| 40 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 41 | For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 42 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 43 | Pre-laminated particle board with decorative lamination on both sides |
| 44 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 45 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 46 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 47 | Superior hard wood category-II (A) (Black chuglum, Thingam, Toungpeing, Pylinma, Koko and Mahawa) |
| 48 | Providing and laying cement concrete surface drain in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate of 40 mm nominal size), including floating coat of neat cement on the inside and exposed surfaces of the drain, with earthwork in excavation and disposal of surplus earth within a lead of 50 m. |
| 49 | 15cm x 15cm |
| 50 | Providing 25x5 mm flat iron hold fast 15 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 15 x 15 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 51 | Making plinth protection 50 mm thick with cement concrete 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over a 75 mm thick bed of stone aggregate of 40 mm nominal size, well rammed, consolidated, and grouted with fine sand, including necessary excavation, leveling, dressing, and finishing the top surface smooth, complete as per direction of the Engineer-in-Charge |
| 52 | Providing and fixing Anodized aluminium hooks and eyes : |
| 53 | 100 mm |
| 54 | Providing and fixing panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked stainless steel butt hinges of size 100x58x1.90 mm, IS:12817 marked (Grade 304), with necessary screws, excluding panelling which shall be paid for separately |
| 55 | Superior hardwood Category–II (A) (Black Chuglum, Thingam, Toungpeing, Pylinma, Koko and Mahawa) 35 mm thick shutters |
| 56 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked SS (304). pressed butt hinges bright finished of required size with necessary screws. |
| 57 | Superior hardwood Category–II (A) (Black Chuglum, Thingam, Toungpeing, Pylinma, Koko and Mahawa). 35 mm thick shutter |
| 58 | Providing and fixing in position facias and eaves board with: |
| 59 | With 18 mm thick and 30cm wide wooden plastic component (WPC) board including fixing with nuts and bolts etc. complete. |