| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-02-2026 | Revised BOQ | BOQ | 23-02-2026 |
| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of Concrete of any description andin any position not otherwise specifically provided complete all as specified and directed. |
| 4 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similarsuspended work |
| 5 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 6 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 7 | Dismantling stone slabs and tiles of any description or thickness in floors, apron etc including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed. |
| 8 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work. |
| 9 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing all as specified. |
| 10 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. |
| 11 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified. |
| 12 | Dismantling wall and ceilingboards (AC, fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 13 | Dismantling boarding any description fixed in any position with nails all as specified. |
| 14 | Dismantling asbestos cement/PVC pipe 75/100 mm dia including clampscomplete all as specified and directed. |
| 15 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 16 | Taking down chowkats or frames with shutters (without taking of shutters) from the frame n.exc 1.5 Sqm each complete all as specified directed. |
| 17 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified directed. |
| 18 | Taking up or down 15mm diaGI steel tubing and connections, including cleaning for refixingcomplete all as specified and as directed. |
| 19 | Taking up or down 20mm diaGI steel tubing and connections, including cleaning for refixing complete all as specified and as directed. |
| 20 | M&Lfor 75 mm thick plain cement concrete (1:4:8) type D-2 using (40mm graded crushed stone aggregates) for sub base in floor fair and rough for receiving tiles all as specified and directed. |
| 21 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed. |
| 22 | Material and labour for Plain Cement Concrete(1:3:6) type C1 using 20mm graded stoneaggregate as in surface channel and drainall as specified and directed. |
| 23 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends foretccomplete all as specified and directed. |
| 24 | Add or deduct for each 25 mm girth or part thereof over or under 30cm(For adjustment in girth of item No. mentioned above) |
| 25 | Material and labour for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating , includiong necessary formworks, complete all as specified and directed. |
| 26 | Use and waste of Form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concreteall as specified and directed. |
| 27 | Use and waste Formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 28 | Use and waste formwork to soffits of suspended slabs such as roof slabs, landings and similar work, not exceeding 200mm thick( Horizontal or Sloping ), for rough finished flat surface of concrete all as specified and as directed. |
| 29 | Use and waste formwork to edges of concrete flats,slabs etc incl fair finished surfaces exe 5cm but n.exe 10cm wide all as specified nd directed. |
| 30 | Material and labour for providing Reinforced Cement Concrete 1:1.5:3 (nominal mix design) type A1 using 20 mm graded aggregateas in beams, cantilever, lintels over 1.5 m complete all as specified and directed. |
| 31 | Material and labour for providing Reinforced Cement Concrete 1:1.5:3 (nominal mix design) type A1using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 32 | Material and labour for providing Reinforced Cement Concrete 1:1.5:3 (nominal mix design) type A1using 20mm aggregate as in slab supported on walls , beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc comlpete all as specified and directed. |
| 33 | Material and labour Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 34 | Material and labour Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 35 | Material and labour mild steelTMT bars 5mm dia and overup to and including 10mm dia as stirrups, spacers etc. , cut to length bend to shape required including cranking bending spirally for hooking ends and bindingwith and includingmild steel wire n.less than 0.90mm dia complete all as specified and directed. |
| 36 | M&L for Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 Complete all as specified and as directed. |
| 37 | M&L for half brick work with sub class \"B\" bricks straight or curved on plan to radious built in cement mortar 1:4 all as specified |
| 38 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on other rough faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer 5mm thick @ 3% finished fair and even without using extra cement complete all as specified and as directed.Note :- WPC measured and paid saperately. |
| 39 | Material and labour 10mm thick rendering in cement mortar (1:6) on other rough face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified. |
| 40 | Supply onlywater proofing compoundall as specified and as directed. |
| 41 | Material and labour light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm and not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including15 mm thick screed bed or bedding layers in cement mortar 1:6completeall as specified and directed. |
| 42 | Material and labour light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm and not exceeding 0.36 sqm as in skirting, dados and risers to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 10mm thick backing coat of rendering with CM 1:4 as specified. |
| 43 | M & L glazed ceramic coloured tiles450x350x7mm thick as in verticalsurfaces such as skirting/dado etc over 10 mm thick cement mortar (1:4) set & jointed in neat cement slurry & pointed in white or coloured cement to match the shade of tile complete completeall as specified and directed. |
| 44 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid over 20mm thick screed bed in cm 1 : 3 with cement slurry @ 4 kg/sqm jointed and pointed with grey cement slurry mixed with pigment to match the shade of slab including cutting and polishing to achieve mirror/granite finish complete all as specified and as directed. |
| 45 | M&L for Non skid ceramic paver tiles area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm floor set, jointed &pointed with neat cement slurry with white cement and pigment including 20mm thick screed bedding layer in cement mortar (1:6)all as specified and directed(make: endurajohnson,Paver Orient Bell or equivalent in somany ) |
| 46 | M&L for 20 mm thick granite (any type) work (table rounded and polished) in steps, jambs pillars, windows-cills cooking plateforms, urinal partitions, stand for WHB and like over 15 mm thick backing coat of cement mortar (1:4) set & jointed in neat cement slurry & pointed in white or coloured cement to match the shade of granite all as specified. |
| 47 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and rubber washer as specified. |
| 48 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and rubber washer as specified. |
| 49 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 50 | S&F of mild steel rolled sections (Fe-290, Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and other misc brackets; fixed with angle cleats for fixing of eaves board or other connecting plates complete all as specified. |
| 51 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one or more rebates includinghinges, lock strike plate, shock absorber, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 52 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates includinghinges, lock strike plate, shock absorber, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 53 | Material and labour Cement concrete (1:3:6), type C-0 using 12.5mm graded stone aggregate as in filling of pressed steel frameand concrete for fixing of holdfast including necessary form work complete all as specified. |
| 54 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 55 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete without glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 56 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified. |
| 57 | S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides , smooth finish with lipping of teak wood on edges all as specified and directed. |
| 58 | S&F 2nd class hard wood, 35 mm thick, plain framed panel shutter (any numbers of panel) with panels of timber flat on both sides (feather edged) or 12 mm thick veneered particle board medium density fitted to chowkats or frames complete all as specified and directed. |
| 59 | S&F 2nd class hard woodglazed andskeleton door shutters 35 mm thick open rebated and prepared to receive glass, guage etc (withoput sash bars), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.20(a) |
| 60 | Supply and fixStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.0mm and fixed with stainless steel wire staples complete all as specified. |
| 61 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified. |
| 62 | S&F300mm length of Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified. |
| 63 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section completeall as specified and directed. |
| 64 | Supply and fix aluminium anodised alloy handles fabricated type 150 mm size of handle complete all as specified & directed. |
| 65 | Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick high Pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI systtem duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid all as specified and directed. Make : Everest Industries Ltd or equivalent as per IS 14862 all as specified and directed. |
| 66 | S&F as in repairs 25 mm dia and 1mm thick MS chromium platedcurtain rods with fixing side fancy type brackets end knobs fixed with steel screws etc all as specified and directed . |
| 67 | Supply and fix in repair vitreous china wash basin, white, under counter, size 565 X 465 X 185 mm oval shape including waste coupling and excluding taps, waste ,chain and plug and porcelain stoppercomplete all as specified. (Parryware Catalouge No- C0483 and Equivalent) |
| 68 | Supply and fix in repair stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc.,overall size 495mm x 420 mm with bowl size 410mm x 330mm x 160mm etc complete all as specified and as directed. |
| 69 | Supply and fix, asin repairs, 32 mm dia and 800mm long PVC flexible corrugated waste pipe for wash basin/sink complete all as specified and as directed.Make: (Prayag CAT No. 327) or equivalent as per make approved list |
| 70 | S&F as in repairs,15 mm bore, Pillar taps, fancy type, cast copper alloy, withcapstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixedcomplete all as specified. |
| 71 | Supply and fix as in repair, 15 mm bore bib taps fancy type, chromium plated, castcopper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. |
| 72 | Supply and fix as in repair 15mm bore stop valve/angle valve, cast copper alloy cromium plated fancy type screwed down high pressure, with crutch or butterfly handle for 15 mm bore pipe or for unions all as specified. |
| 73 | S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 74 | S & F in repair Soap Dish chromium Plated complete all as specified& as directed. |
| 75 | Supply and fix in repair Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 76 | S&F as in repair bevelled edge mirror 5.50mm thickness complete all as specified and directed.Make : Modiguard, Saint Gobain or equivalent |
| 77 | Supply and fix 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.. |
| 78 | Supply and fix 75 mm bore PVC (SWR) bends and radius complete all as specified and directed. |
| 79 | Supply, lay and fix 15 mm bore galvanised iron water tubing medium grade including all fittings and fixed complete to wall and ceiling or laid in floors., all as specified and directed |
| 80 | Supply, lay and fix 20 mm bore galvanised iron water tubing medium grade including all fittings and fixed complete to wall and ceiling or laid in floors., all as specified and directed |
| 81 | Cuttinggrooves or rebates not exceeding 15 cm girth, and trimming with or without reinforced surfaces complete all as specified and directed. |
| 82 | Supply and fix as in repair 20 mm bore dia, Gun-metal, gate valves, with iron wheel head, screwed both ends on GI pipes with GI union fixed in existing/ new location including removing old unserviceable ones completeall as specified and directed. |
| 83 | M&L for preparation of new plastered surface of walls and applying three coats of white wash on wall complete all as specified. |
| 84 | Material and labourpreparation of new plastered surface of walls and applying two coat of oil emulsion distemper over one coat of primer on wall complete all as specified. |
| 85 | M&L for providing and applying wall care putty 1 mm thick in two layers over plastered surface to prepare the surface even and smooth. |
| 86 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm. complete all as specified and directed. |
| 87 | Material and labour preparation of new or previously untreated steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 88 | Material and labour preparation of old steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 89 | Material and labour for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 90 | E & M Division items |
| 91 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 92 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking in credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 93 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 94 | Taking out old U/s XLPE cable of any size/type taking out of olf bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 95 | Dismantling of U/s GI pipe of size 50 mm bore complete all as specified and directed. |
| 96 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 97 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 98 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 99 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 100 | All as per item above mentioned but with FRLSH stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated and unsheathed cable 1100 Volt grade ISI-694 markedfor 3 pin, 15 Amp socket outlet, independent, including FRLS PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly. |
| 101 | All as per item above mentioned but with FRLSH starnded copper conductor4 sqmm for one power point on independent board and including 4 sqmm earth continuity wire for AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 102 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 103 | S&F switch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 104 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 105 | S&F switch socket combination 5 in 1, 5/16 Amp flush type with all as specified and directed. |
| 106 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 107 | S&F lamp angular holder insulated body with back plate suitable for batten fittings all as specified and directed. |
| 108 | S&F 600 x 600 mm LED type down lighter 36 watt complete with drivers connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. |
| 109 | S&F wall mounted, compact LED batten including 20 watt LED tube rod and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Cat No: LDLL20-WW of Crompton or equivalent make of Havells/M/S Jaquar & Company Pvt Ltd. |
| 110 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp of suitable size complete all as specified and directed.. |
| 111 | S&F LED bulb 10 watt, 5 star rated and connecting to lamp holder complete all as specified and directed. Cat No: LED 10W 5 Star Lamp of Crompton or equivalent make of Havells/M/S Jaquar & Company Pvt Ltd. |
| 112 | S&F bldg security light, LEDluminaire 30 watt IP 66 LED lamp, driver etc with all accessories complete all asspecifiedand directed. Cat No. LSTS-25-CDL/NL-M of Crompton or equivalent make ofHavells/M/S Jaquar & Company Pvt Ltd. |
| 113 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated including taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed. |
| 114 | S&F steel body exhaust fan380mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 115 | S&F plastic body exhaust fan300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 116 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 117 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 118 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 119 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 120 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 121 | S&F MCB TPN of capacity 63 Amps 4 pole,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 122 | M&L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 123 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 124 | M&L PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate with 100mm thick for flooring complete all as specified and directed. |
| 125 | Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set (engine as per IS-10001/10002 and alternator as per IS-13364) of capacity 58.5 KVA, 415 Volts +/- 5% AC, 3 phase 4 wire, 50 Hz at 0.8 PF (lagging) at 1500 RPM complete with AMF panel with necessary protection & meters including sound proof canopy, including the following:-(A) ENGINE:- Engine shall be multicylinder four stroke (58.5 KVA), Radiator water/coolant turbo charged with mechanical governor with the following:-(i) Fuel level indicator.(ii) Fuel tank of capacity as per manufacturer\"s recommendation.(iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement.(iv) Exhaust manifold and residential type silencer.(v) Continuous 10% overload capacity in every 12 Hrs running.(vi) Self starting with and including maintenance free battery including charging circuit.(vii) Radiator with first fill of coolant.(viii) Turbocharger with continuous duty rating.(ix) First fill of lub oil.(x) Coolant temp gauge, Lub oil, Pressure gauge, Tacho-cum-hour-meter.(xi) Engine spare parts list and maintenance manual - 03 copies.(B) ALTERNATOR:- 58.5 KVA, 0.8 PF (lag), 415 Volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with self regulated brushless self excitation & automatic voltage regulator with band of voltage regulation + 2.5% of rated voltage.(C) BASE FRAME:- Sturdy robust MS frame duly bolted, coupled, aligned, tested and housed within acosutic enclosure with anti-vibration pad. |
| 126 | (D) ACOUSTIC ENCLOSURE:- It should be compact, modular construction and approved by ARAI (Nodal agency of CPRI) with the following:-(i) Overall noise level less than 75 dB measured at 1 mtr distance in free field condition. (ii) Inside illumination shall be suitable as per manufacturer\"s design.(E) AMF PANEL:- Inbuilt Gen set control & AMF Panel with microprocessor controller with engine safety protection & AMF Panel with suitable electrical & control fixture of auto start & stop, protection class IP-65, dust, weather proof and vermin proof duly powder coated after seven tank process, with electrolyte grade copper bus bar of 300 Amps capacity for three phase & neutral, with all standard switch gear such as power contactors of 250 Amps, relays etc. and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of the following:- |
| 127 | (i) MCCB 415 Volts, 250 Amps, rating 4 pole 25 KA rupturing capacity, microprocessor based release for incoming supply overload, short circuit abd earth fault protection - 02 No.(ii) Ammeter 0-500 Amps, 96 x 96 mm square dial flush type ISI marked with selector switch 3 way - 01 Set.(iii) Voltmeter 0-500 Amps, 96 x 96 mm square dial flush type ISI marked with rotary selector switch 3 way - 01 Set.(iv) Phase indicator lamp (RYB) - 01 set.(v) Frequency meter digital type 45 to 55 Hz - 01 No.(vi) KWH meter 3 phase unbalanced load 1200 Amps capacity including CT coil - 01 Set.(vii) Auxilliary contacts.(viii) All standard relays circuits and protection required for automatic operation of GEN Set.(ix) Battery Charger. |
| 128 | NOTE:- (a) Any other accessories shall be provided as per manufacturer\"s recommendation and cost of the same deemed to be included in the quoted rate.(b) Cost of testing including arrangement of artificialload upto 110% of rated capacity, temporary arrangement of connecting cables, decibel meter and cost of fuel & testing material shall be deemed to be included in the quoted rate.(c) Construction of PCC foundation as per OEM design for mounting the DG Set including cost of necessary excavation and earth work in any type of soil shall be deemed included in the quoted rate.(d)DG set shall be tested as type test, routine test as per IS in the presence of GE and rep as decided by the Accepting Officer.(e)The contractor shall submit QAP (Quality Assurance Programme) with in the 15 days from placement of order for DG set testing at factory premises. DG set shall be dispatched after inspection clearance by inspecting officer.(f)The contractor shall get the approval of GE for the make of the DG set as they plan to procure.(g) Prior to manufacturing the general arrangement drawing Design details of the DG setshall be got approved by GE. |
| 129 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.Note:Rate of under ground cable includes earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing where necessary,testing etc. |
| 130 | M&L for earthing with galvanised steel earth plate electrode600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level and connected to 32 x 6mm thick GI strip protected by 40 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternater layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of soil to a distance not exceeding 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed. |
| 131 | Taking out old existing earthing and M&L for new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 132 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 133 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 134 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 135 | Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqdcover after punning down complete all as specified and directed. Note:- Thickness of sand cushion after punning down will be measured and paid separately. |
| 136 | Supply and laying burnt bricks of sub-class \"B\" designation of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 137 | Material & labour GI tube light grade 50 mm bore for protection ofcable complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |