| 1 | Comprehensive monthly maintenance of automatic fire alarm system and fire suppression system, installed at LHS and RHS of Lion Gate, Naval Dockyard, including attending day-to-day complaints, complete all as specified and directed by the Engineer-in-Charge.(i) The scope of work shall include comprehensive maintenance of all equipment forming part of the fire detection and fire suppression systems installed in the above locations. The maintenance shall include attending day-to-day complaints related to false alarms, system faults, trouble signals and similar issues on an emergency basis, ensuring prompt response and restoration of the system to normal working condition.(ii) The work shall also include cleaning, inspection, checking and rectification/repair of defects such as faulty detectors, wiring problems, power supply failures, nuisance alarms and other operational issues, as required, for all equipment of the fire detection and fire suppression systems.(iii)Operational testing of all equipment of the fire detection system, including control panels and field devices, shall be carried out periodically and as required, in the presence of the User’s Representative and the Engineer-in-Charge to verify satisfactory performance.(iv)Emergency visits shall be carried out whenever called, in addition to routine monthly maintenance, in the event of any system failure due to any cause, without any additional cost to the department.(v) Materials required for replacement of defective components shall be measured and paid for separately under the respective items of this Schedule as SUPPLY ONLY.Note- Comprehensive monthly maintenance of the fire alarm detection system shall be carried out in accordance with the maintenance schedule specified in ANNEXURE-I, and detailed maintenance and test reports shall be submitted to the Engineer-in-Charge within the stipulated time, which shall be manditorily required before payment of RARs. |
| 2 | Supply and fix in replacement of photo-electric smoke cum thermal detector with compatible mounting base, suitable for the existing addressable / conventional system as applicable complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supplying, installing, testing and commissioning of analog addressable multi-criteria detector (optical + thermal) with integral LED indicator, suitable for above-ceiling and below-ceiling installation, complete as per system configuration complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply, installation, testing and commissioning of addressable Manual Call Point (MCP), pull-down / break-glass type, semi-flush mounting. Unit shall have LED blinking in normal state and steady during activation. Device shall be UL-listed and compatible with existing addressable loop complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply, installation, testing and commissioning of conventional Manual Call Point (MCP), pull-down / break-glass type, semi-flush mounting, with LED blinking in normal condition and steady on activation. Device shall be UL-listed.complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fix in replacement of intelligent addressable monitor module, suitable for interfacing third-party contact devices with the existing addressable loop complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and fix in repair of fault isolator module with automatic resetting arrangement for isolating short-circuit conditions on addressable loops, complete with necessary accessories complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supplying, installing, testing and commissioning of response indicator for above-ceiling and cabin detectors, complete with LED indicator and necessary accessories complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supplying, installing, testing and commissioning in repair of addressable control module suitable for AHU shutdown, access-control integration, staircase pressurization fan, hooters, sounders, strobes etc., including configuration as per existing system architecture complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply, fix, test and commission in repair of addressable electronic hooter with in-built amplifier and dual-tone generator, having minimum audible range of 100 metres, complete including all connections and configuration.Complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply only addressable or conventional type heat detector with base, rate-of-temperature-rise type, conforming to IS 2175, complete with necessary accessories Complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supplying, installing, testing and commissioning of conventional beam detector suitable for hall and indoor open areas, complete with transmitter, receiver, mounting hardware and alignment as per tender specifications.Complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supplying, installing, testing and commissioning in repair of UV + Triple IR (Radiant Energy) multi-spectrum flame detector, suitable for long-distance detection with high false-alarm immunity. The detector shall have:• Multi-spectrum UV & IR sensors• Clear line-of-sight detection• Adjustable sensitivity ensuring no zone cross-over• Fast response time for rapid and accurate flame detection• Multiple output relays (flame / fault / auxiliary)• RS-485 Modbus compatibility• User programmability via Bluetooth• Built-in self-test• Mobile alert & IoT connectivity• Date-time stamped event loggingComplete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply only addressable fire alarm control panel, single-loop type, complying with BS EN 54 / UL, suitable for a loop capacity supporting up to 126 detectors and 126 modules, complete with all standard features.Complete all as specified. |
| 15 | Supply only addressable fire alarm control panel, double-loop type, complying with BS EN 54 / UL, suitable for loop capacity supporting up to 126 detectors and 126 modules per loop, complete with standard system features complete all as specified. |
| 16 | Supply only addressable fire alarm control panel, four-loop type, complying with BS EN 54 / UL, suitable for loop capacity supporting up to 126 detectors and 126 modules per loop, complete with all accessories.Complete all as specified. |
| 17 | Supply only addressable fire alarm repeater panel, complete with display, control keys, communication interface and necessary accessories for integration with the main fire alarm control panel.Complete all as specified. |
| 18 | Material & Labour for taking out unserviceable repeater or fault control panel from existing fire detection system, carrying out repairs including replacement of defective components/PCBs/modules, and refixing the same at original location including testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fix in replacement of PCB loop cord suitable for self-addressable fire finder system, including all terminations and testing complete all as specified. |
| 20 | Supply and laying of PVC FRLS armoured cable, 1.5 sqmm, solid copper conductor, 2-core, XLPE insulated, extruded PVC sheathed, galvanized steel strip armoured, 1100V grade (heavy duty), laid in duct / along pole / wall including making termination connections and making good the disturbed surfaces to match with existing finish complete all as specified and directed by Engineer-in-Charge.Note: Cost of aluminium thimbles/lugs, cable glands etc. is deemed included in the quoted rate and no extra payment shall be made. |
| 21 | Supply and laying of PVC FRLS armoured cable, 1.5 sqmm, solid copper conductor, 4-core, XLPE insulated, extruded PVC sheathed, galvanized steel strip armoured, 1100V grade (heavy duty), laid in duct / along pole / wall including making termination connections and making good the disturbed surfaces to match with existing finish complete all as specified and directed by Engineer-in-Charge.Note: Cost of aluminium thimbles/lugs, cable glands etc. is deemed included in the quoted rate and no extra payment shall be made. |
| 22 | Supply and fixing of MS conduit, 20 mm diameter, including fixing accessories such as saddles, couplers, bends, tees and other necessary fittings, complete with all fixing arrangements complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and fix in replacement of UPS 1.0 KVA, suitable for 230 Volts, 50 Hz AC power supply, complete with all accessories and connections required for proper functioning.Complete all as specified. |
| 24 | Supply only 12V, 7AH sealed maintenance-free battery, suitable for UPS / fire alarm equipment backup, complete with all accessories as required Complete all as specified. |
| 25 | Supply and fixing of PVC DLP on-wall trunking, size 80mm × 50mm, complete with cover and all finishing accessories including partitions, joints, internal/external angles, end caps, lid joints, body joints, derivation pieces, supports, cable clips, cable ties etc., installed on wall surfaces as directed.Complete all as directed by Engineer-in-Charge. |
| 26 | Supply and fix of MS/GI hot-dip or powder-coated perforated cable tray, sheet thickness not less than 1.6 mm, tray height not less than 50 mm and tray width not less than 450 mm, installed vertically or horizontally on brick/stone wall, including 2.0 mm thick tray cover. Work includes all accessories such as bends, coupler plates, nuts, bolts, shaping, bending, drilling, welding, cutting and complete fixing arrangement Complete all as specified and directed by Engineer-in-Charge. |