| 1 | Surface dressing n exc 15 cm deep in soft/ loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 4 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundations, fillings, Mass concrete, footings etc complete all as specified and directed. |
| 6 | M&L Reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | M&L Reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 8 | M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 9 | M&L 100 mm thick PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in sub-floor, sub-base, floor and pavings, finishing cement concrete surface even and smooth without using extra cementetc. complete all as specified and directed. |
| 10 | Use & waste formwork for rough finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam and similar work; vertical or to batter complete all as specified and directed. |
| 11 | M&L Reinforcement TMT Steel bars of grade Fe-500/Fe-500 D of 10mm dia and over, cut to length, bent to shape required, incl cranking,bending , spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed. |
| 12 | M&L Reinforcement TMT Steel bars of grade Fe-500/Fe-500 D of 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, incl cranking,bending , spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed. |
| 13 | S&F mild steel bolts. dia of neck exc 12mm but not exc 20mm long purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square complete all as specified and directed. |
| 14 | S&F Rolled mild steel sections as in main and cross beams, hip and jack rafters; Purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates of Fe-410-W(Gde-E-250 quality-A) (framed)etc,complete all as specified. Note :- Height of bldg more than 10 meters. |
| 15 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. Note :- Height of bldg more than 10 meters. |
| 16 | S&F 1.25mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. Note :- Height of bldg more than 10 meters. |
| 17 | S&F Pre-painted galvalume aluminium zink coating GI based Plain steel sheet (AZ-150) 0.50 mmthick of an colour having tensile strength of 550 Mpa as in roof covering/ Clading to wall, Ridge and eaves board, fixed with self tapping screws complete all as specified and directed. Note :- Height of bldg more than 10 meters. |
| 18 | S&F plain FRP sheeting 4mm thickat north light curves, roofs, windows, duct covering or at any other location by coach screw and washer, nut & bolt, staple pins or any other sutiable means all asspecified and decided. Note:- Height of bldg more than 10 meters. |
| 19 | M&L for preparation of new steel surfaces of any description over 10cmin width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. Note :- Height of bldg more than 10 meters. |
| 20 | S&F GI snap grid of size 605X605mm forframe work for false ceiling including 1.5mm dia GI hangers complete all as specified and directed. Note :- Height of bldg more than 10 meters. |
| 21 | S&F 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping with screws complete all as specified and directed. Note :- Height of bldg more than 10 meters. |
| 22 | Earth filling under floors with excavated soil incl, spreeding levelling in layers n.exc 25cm thick each and well ramming including water as required and removal of the excavated materils complete all as specified and directed. |
| 23 | M&L brick work with fly ash old size bricks, straight or curved on plan exceeding6 cm mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 24 | M&L for 40mm thick Damp proof course in cement concrete 1:2:4, type B-0, horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 25 | M&L for reinforced cement concrete 1:2:4 type B0 (using 20mm graded stone aggregate) as in roof beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 26 | M&L for reinforced cement concrete 1:2:4 type B0 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 27 | Use & waste of formwork for rough finished surfaces to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc also splays between floors and beams, etc complete all as specified and directed. |
| 28 | Use & waste of formwork for rough finished surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work complete all as specified and directed. |
| 29 | Use & waste of form work for rough finished surface to edges of concrete flat, break in floor cills, railings etc. & similar works, exc 5cm but n exc 10cm wide complete all as specified and directed. |
| 30 | M&L for Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfacesfinished even and smooth without using extra cement complete all as specified and directed. |
| 31 | M&L for Rendering 15mm thick in CM 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement using water proofing treatmentcomplete all as specified and directed. Note:-Water proofing shall be measured & paid separately. |
| 32 | M&L for rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | Supply only integral water proofing compound only complete all as specified and directed. |
| 34 | M&L preparation of newly plaster surface of wall and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 35 | M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 36 | M&L for three coats of white wash on newly plastered surface or unplastered surfaces of ceiling including preparation surface complete all as specified and directed. |
| 37 | M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 38 | M&L 75mm thick PCC in plinth protection and paving in PCC 1:3:6 type C-1, (using 20mm gradded stone aggregate) finishing cement concrete evenand smooth in slope without using extra cement complete all as specified and directed. |
| 39 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm soft/loose soil complete all as specified and directed. |
| 40 | M&L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundations, fillings, Mass concrete, footings etc complete all as specified and directed. |
| 41 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 42 | M&L for preparation of steel and iron surface exceedding 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zink chrome primer complete all as specified and directed. |
| 43 | M&L for preparation of steel and iron surface not exceedding 10 cm width or girth and applying two coas of synthetic enamel paint over one coat of red oxide zink chrome primer complete all as specified and directed. |
| 44 | M&L Preparation of surfaces of any description wood/steel, iron etc exc 10cm in width or girth and applying one coat of black bituminous paint on embedded steel post portion complete all as specified and directed. |
| 45 | Supply only galvanised, medium zinc coating 135-150 GSM as per IS-2721-2003 Chain link fencing. Note :- In every 1 to 3 mtr original manufacturer logo printed chain link fencing wire and material test certificate and authentication should be provided by manufacturing company. |
| 46 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire complete all as specified and directed. |
| 47 | S&F MS bolts n exc 12 mm dia purpose made with hexagonal or square head one end with nut and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexogonal or square complete all as specified and directed. |
| 48 | S&F Mild steel roundbars 10 mm dia and over, cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and bindingwith and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. (Fe-410-W) (Gde.E-250) quality-A or Fe-290(Gde-E-165) complete all as specified and directed. |
| 49 | Supply and Fixing Galvanised, medium zinc coating 135-150 GSM as per IS-278-2003, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any of standard rails, straining bolts, including, securing or typing at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).Note :- In every 1 to 3 mtr original manufacturer logo printed barbed wire and material test certificate and authentication should be provided by manufacturing company. |
| 50 | Supply and Fixing Galvanised, medium zinc coating Min 120 GSM as per IS-4454-513, punch tap concertinal coil as per following specification :-(i) Coil Dia 610mm(ii) Wire dia - 2.59 mm with high tension tensile strength not less than 1500 N/Sqmm.(iii) Minimum 50 rounds in 6 Mtr opening length.(iv) Blade thickness 0.50 mm, 15 mm wide with 15 mm external pitch.(v) Min five clips per round. Note :- Material test certificate and authentication should be provided by manufacturing company. |
| 51 | Excavation over area n. exc 1.5M in depth and geting out in soft/loos soil complete all as specified and directed. |
| 52 | Rooling and consolidating formation surfaces for exc 8 tonne and not exc 12 tonne power roller in cutting complete all as specified and directed. |
| 53 | M&L for Laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course (GSB) grading as per GSB Grade II as per Table 900-1 o MaRTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with natura sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-1 00 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MaRTH specifications for Road and Bridge works, 2013. complete all as specified |
| 54 | M&L for Laying and compacting 150mm thick (compacted thickness ) WMM laid in two layers of 75 mm eachWet Mix Macadam (WMM) grading as pe table 400-13 of MaRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with wate to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradien and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MaRTH specifications for Road and Bridge works 2013 complete all as specified and as directed. |
| 55 | Preparing unsurfaced wet mix macadam surface by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and directed. |
| 56 | M&L Applying evenly a priming/tack coat with bituminous primer of paving bitumen VG-10/VG-30 @ 10Kg/10 Sqm over WMM surface complete all as specified and directed. |
| 57 | M&L Applying evenly a priming/tack coat with bituminous primer of paving bitumen VG-10/VG-30 @ 5Kg/10 Sqm over bituminous macadam surface complete all as specified and directed. |
| 58 | M&L for Premix bituminous macadam paving bitumen any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness n. exc 75mm) using 4% binder (Viscosity grade VG 30) with 8 to 12 tone power roller complete all as specified and directed. |
| 59 | M&L for Bituminous premix asphaltic semi dense concrete 40mm consolidated thickness with 5% binder (viscosity grade VG-30) content by weight of total mix, rolled and compacted to required camber and gradient, and laid with mechanical paver and rolled to a uniform smooth surface with 8 to 12 tonne power roller and compacted to required camber and gradient complete all as specified and directed. |
| 60 | M&L for cleaning the new road surface of dirt, oil/ grease spots and foreign material etc and applying 2.5mm thick road marking strips (retro reflective) of white colour using Hot Thermoplastic material by fully/semi automatic thermoplastic paint applicator machine complete all as specified and directed. |
| 61 | S&F cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions complete all as specified and directed. |
| 62 | S&F metal tubular dealineator made out of ABS round body fitted with 2 Nos 65mm dia highlyreflective reflectors made out of PAMA and mounted on 45/50mm dia mild steel pipe of 600mm height duly powder coated and thermo plastic elastomer 3 bands of green , red and yellow reflector radium tape of 25mm wide strps with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300) type B-1 complete all as specification and directed |
| 63 | M&L continuous brick edging; with width equal to the length of the brick; laid dry on edge vertically with burnt clay bricks of sub class B including necessary excavation and returning filling complete all as specification and directed |
| 64 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core,complete all as specifiedand directed. |
| 65 | Supply and laying GI tubes light grade, galvanised, 25 mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for mechanical protection of electric cable complete all as specifiedand directed. |
| 66 | M & L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying the cable and then punned. After punning thickness of sand cushioning shall be 18 cm complete all as specified and directed. Note:- Punned thickness of sand shall be measured. |
| 67 | Supply and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat,size 230mm x 115mmx 75mm, complete all as specified and directed. |
| 68 | M&L for point wiring with Single core pvc (FRLS) insulated, unsheathed, stranderd copper conductor of size 1.5 sqmm with 1.5 sqmm earth lead of same specification, concealed type, drawing in & including pvc conduit medium grade not less than 25 mm dia, having wall thickness not less than 2 mm with all fittings with MS/CI sunk box of wall thickness not less than 1.2 mm thick sheetincluding one coat of red oxide primer on internal and external surface covered with 3 mm thick IS-2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc.) all as specified for the following :- |
| 69 | One light / fan point controlled by one switch one way complete all as specified and directed. |
| 70 | M & L for switch piano flush type 5 amps SP one way 230 volts complete all as specified and directed. |
| 71 | M & L ceiling rose three terminals/PVC/polycarbonate,isolated body on PVC board complete all as specified and directed. |
| 72 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeand overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed. |
| 73 | Supply and fixing Lamp holder, insulated body PVC/Polycarbonate type with back plate suitable for batten/angular/pendent holder fittings complete all as specified and directed. |
| 74 | Supply and fixing LED lamp 9 W suitablefor item No:5, complete all as specifiedand directed. |
| 75 | Supply & fix sheet metal enclosure MCB distribution boardsingle pole & neutral 240 volts 2 way with single door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .(Note-MCBs will be measured separately.) |
| 76 | Supply and fixing Isolator SP 240 volt of rating 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed. |
| 77 | Supply and fixing MCBsingle pole 240 volt any rating from 5 to 40 amps , with rupturing capacity 10 KA ,inculding providing thimble for out going cable. |
| 78 | SSupply and fixingLED street light 30 Watt with pressure die-cast housing with individual LEDs as light source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK 07 complete with connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 1.0 sqmm complete all as specified & as directed by Engr in Charge. |
| 79 | Supply and fixingStreet light bracket made up of 40 mm bore light grade GI pipe 1.2 mtr long inclding necessary bending welding etc complete all as specified and directed. |
| 80 | M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010. |