| 1 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 2 | Dismantling of brick tiles, terracing tiles, single layer from roof laid, beddedand pointed in any mortar allas specified & directed. |
| 3 | Removalof Mud from top roof slab, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof). |
| 4 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases ,landing chajjas and similar suspended work(Reinforcement cut as required to facilitate demolition)of any description and in any position not otherwise specially provided |
| 5 | Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and as directed. |
| 6 | Roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 Kg of cement per sqm all as specified and directed |
| 7 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar. |
| 8 | M&L 20 to 25 mm thick prepolished machine cut Kota stone slab as in flooring over and including 15mm thick screed bed in cement mortar 1:6, laid over cement slurry @ 3 Kg/Sqm and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge of slabcomplete all as specified and as directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above). |
| 9 | M&L 20 to 25 mm thick prepolished machine cut Kota stone slab as in riser or vertical surface over or as in skirting and including 10 mm thick rendering in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge where as specified and as directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size as in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above). |
| 10 | M & L Brickwork with subclass \"B\" Brick straight or curved on plan exc 6m mean radius, built in, built in cement mortar 1:6 complete all as specified. |
| 11 | Ditto- item No.10 above but except brick complete. |
| 12 | M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces ofrequired thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessarychased to brick work or RCC members at any height upto four storey buildings incl removing of small trees shrubs etc all as specified(Note: steel welded mesh to be welded with the existing reinforcement.The cost of welded meshis to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed. |
| 13 | M&L for Reinforced Cement Concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in chajjas complete (reinforcement to be measured separately). |
| 14 | M&L for providing precast cement concrete in window or door cills, lintels, bressumers, steps quoin blocks ( for use with masonry) string coarse coping, post column boundary pillars set in cement mortar 1:4 complete with joint match used in RCC Jali frame in opening etc |
| 15 | M&L for Reinforcement cement concrete (design mix) in M-25 using 20mm graded stone aggregate as in columns pillars piers posts and struts etc. |
| 16 | M&L for Reinforcement cement concrete (design mix) in M-25 using 20mm graded stone aggregate as in beams, cantilevers bressummers, lintels over 1.5m span all as specified and directed. |
| 17 | Mild steel TMT bars 10 mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete. |
| 18 | Mild steel TMT bars 6 to 8 mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete. |
| 19 | Ditto item no 18 but 5 mm dia and over upto 10 mm dia in stirrups, spacers and binders. |
| 20 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lilntels, cantilevers, shelves inclusing supports, overhangs, etc, also splays between floors and beams, etc. |
| 21 | Use and waste of formwork to chullah hoods, chajjas, throughs and similar items including edges |
| 22 | Use and waste of formwork tosides of pillars, posts, struts, piers, columns and stanchions |
| 23 | Taking down existing cementplaster including racking out joints, hacking for key, scrubbing down with water etccomplete all asspecified and as directed. |
| 24 | M&L 15 mm thick Rendering in cement mortar 1:4 on faces of brick work or concrete external surfaces of wall finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge. |
| 25 | M&L 15 mm thick Rendering in cement mortar 1:6 on faces of brick work or concrete internal surfaces of wall, finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge. |
| 26 | M&L 5 mm thick rendering in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even and smooth complete. |
| 27 | M&L for Preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete. |
| 28 | M&L for Preparing new plastered surfaces of wall and applying two coats of oil bound distemper white or tinted over and including a coat of primer on plastered surfaces complete. |
| 29 | M&L for followings :-(i) Removing plaster & finishes all around the RCC memeber.(on all four sides of column to full height, three sidescription of beam to entire span & bottom of slab to area as directed)(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible)(iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference in case of coluns & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)(iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved.(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out. |
| 30 | M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. |
| 31 | M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM of 30 thickNote:-Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. |
| 32 | M&L for Drilling & chemical anchoring of new rebars/stirrups:-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-10-12 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete all as specified and directed. Note:- The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item |
| 33 | M&L for use & waste of form work using steel sheets, steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed.Note:-Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured. |
| 34 | M&L for Providing & Pouring Micro concreting M-40 grade :-(i) Dry concrete substrate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed.Note : The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item. |
| 35 | S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, includingcranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed. |
| 36 | S&FPVC (SWR) pipes single socketed in any lengthwith rubber ring joints fixed to walls 110 mm boreincluding demolition/taking down PVC/CI drain/Rain water pipe complete. |
| 37 | S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm boreincluding demolition/taking down PVC/CI drain/Rain water pipe complete. |
| 38 | S&F PVC (SWR) branch piece, double (double Y) equal or unequal with access door of 110mm bore complete. |
| 39 | M&L applying synthetic enamel paint on old steel surfaces of any description over 10cm width or girth including preparation of steel surfaces complete. |
| 40 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frame or stone,concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 41 | Supply and fixing 3mm thick obscured or frosted, on one side and glazing with oil putty completesie of each panenot exc 0.50 Sqm complete all as specified and directed. |
| 42 | M&L cutting crack to \"V\" groove section in existing roof cleaning out wetting grouting with cement and sand slurry of 1:3 complete all as specified and directed. |
| 43 | M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints. |
| 44 | M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed. (Rate of WPC shall be included in unit rate) |
| 45 | S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the samemanner incl 15 mm thick screed bed in 1:6. |
| 46 | M&L for preparing new plastered surfaces of wall and providing and applying plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New York ( Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified as directed by Engr-in-Charge. |
| 47 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing, complete all as specified and directed. |
| 48 | M&L for point wiring with 1.5 Sq.mm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable confirming to IS 694:2010 with and including continuous earth wire of size 1.5 Sqmm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353: 1985 drawan through and including rigid non-metallic PVC concealed conduit of 20mm dia (Nominal bore) or higher, medium grade confirming to IS 9537(Part 3): 1983 complete with and including all PVC conduit accessories and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM confirming to IS 14772 : 2000 having op, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732: 2019 and directed by Engr-in-Charge, for One light / bell point controlled by one, one way switch 06 Amps, complete all as specified and directed. |
| 49 | All as per item No 48 here-in-before but one Ceiling / exhaust fan point controlled by one, one way switch 5/6 Amps |
| 50 | All as per item No 48 here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch |
| 51 | All as per item No 48 here-in-before but with point wiring 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 5/6 Amps switch but not below the switch board of light points in the same vertical plane. |
| 52 | All as per item Srl item No.48 here-in-before but point wiring with 4 Sqmm (Nominal size) single core FRLSH cables and earth continuity wire of 4 Sq mm (Nominal size) single core FRLSH cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete |
| 53 | S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed |
| 54 | S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete |
| 55 | S&F modular socket outlet 03 Pin, 06 Amps, 02 module with shutter complete |
| 56 | S&F modular socket outlet 02 in 01, 03 pin, 6/16 Amps, 02 module with shutter complete |
| 57 | S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm sizecomplete |
| 58 | S&F surface/wall mounting LED batten luminaire with System Power : 20W, Length : 4ft,Housing : Epoxy powder coated white extruded aluminium channel, Diffuser : Milky white Polycarbonate, Rated Voltage : 240V, Safe operating Voltage : 140V to 270V,Rated Frequecy : 50 Hz,Power Factor : ≥ 0.95,THD : ≤ 10,Operating Temp : - 10 deg C to + 45 deg C, Lumen Efficacy of LED : ≥ 120 Lm/W,System Luminous Efficacy :≥ 100 Lm/W, CRI : ≥ 80, CCT : 5700K, Driver : Integral SMPS based constant current type with short circuit , surge voltage protection upto 2.5 KV, IP rating : 20 and IK rating : 03 complete all as specified and as directed. |
| 59 | S&F decorative wall mounting lightSS finish fixture with extruded glass difuser suitable for up to 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb having minimum efficiacy at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@ operating voltage 170V-240V for fixing in decorative wall mounting light and all accessories pre-wired including connecting upincluding taking down of existing u/s light fitting complete |
| 60 | S&F surface mounted LED building security light fitting in high pressure die cast aluminium housingpolycarbonate deffuser not less than 35 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 2.5 KV, CCT 6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V including light grade GI tube mounting size 40MM bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc completeand one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core including T/D of old UNSV and depositing in MES store yard complete all as specified and as directed. |
| 61 | S&Fof Ventilating fan, PVC body of size 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frame/all required arrangement for mounting of fan including making good of disturbed surface and taking down old fan and depositing in MES Store etc complete. |
| 62 | S & F 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose and taking down old ceiling fan depositing in MES store complete all as specified and directed. |
| 63 | M&L for sub main wiring with 4 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of suitable dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing including taking down old sub main wiring complete. (Note : 3 Run of single core wire and 1 run of conduit shall be measured and paid as 1 unit), complete all as specified and directed. |
| 64 | S&F in replacement sheet metal enclosure distribution board confirming to IEC- 61439-3, single pole and neutral, AC, 240 volts,12 way, with 100 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete. ( Note :- MCB and DB shall be of same make), complete all as specified and directed. |
| 65 | S&F in replacement sheet metal enclosure distribution board Vertical triple pole and neutral (VTPN), AC, 440 volts, 04 ways with minimum 200 Amps rated copper bus bar for each phase, 2 neutral bar, 2 earth bar and cable ties metal door with IP 43 & IK 09 protection confirming to IEC 61439-3, along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed suitable for 4-pole MCCB as incomer & MCB SP as outgoing having rating as per load requirement |
| 66 | S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete |
| 67 | S&F in replacement MCB confirming to ISI/IEC- 60898-1(2002), SP, AC, 240 volts of 06 to 32 Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs , complete all as specified and directed. |
| 68 | S&F in replacement MCB confirming to ISI/IEC- 60898-1(2002), SP, AC, 240 volts of 40 to 63 Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs , complete all as specified and directed. |
| 69 | S&Fin replacement MCB confirming to ISI/IEC- 60898-1(2002), SPN, AC, 240 volts of 40 to 63Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs, complete all as specified and directed. |
| 70 | S&F of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 32 Amps, \"C\" curve 10 KA breaking capacity and flush to wall/ surface as per site conditions including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing, complete all as specified and directed. |
| 71 | Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 50 sqmm 31/2 core nominal cross section complete |
| 72 | Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out in loose/soft soil for laying of cable complete all as specified & directed |
| 73 | Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting pointcomplete all as specified and directed |
| 74 | Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed |
| 75 | Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed |
| 76 | Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed. |
| 77 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI wire 4 mmdia by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing strip, 20 mm bore light grade GI pipe for watering, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20 mm bore light grade,funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point / equipment and testing complete (Note :- Testing will be carried out in presence Engr-in-Charge) |