| 1 | NOTE: Schedule ‘A’ Part Ito VIIIunder Ser No. 1.01to 1.08 are Prepriced by MES. |
| 2 | Lump sum price worked out by the Contractor for “BUILDING WORK” as listed in Schedule ‘A’Part-I |
| 3 | Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORKS” as listed in Schedule ‘A’Part-II |
| 4 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’Part-III |
| 5 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’Part-IV |
| 6 | Lump sum price worked out by the Contractor for “PLUMBING WORKS” as listed in Schedule ‘A’Part-V |
| 7 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’Part-VI |
| 8 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’Part-VII |
| 9 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY WORKS” as listed in Schedule ‘A’Part-VIII |
| 10 | SCHEDULE `A\" PART - IX MISCB/R & E/M ITEMSis not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 11 | INTERNAL ELECTRIFICATION WORKS |
| 12 | S & F of LED Bulb, B22type ,9 watt, complete all as specified and directed. |
| 13 | Supply & fix wall mounted 1x20 watt LED 6500Ktube light fittings (4 feet long),Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficientwith all accessories and making connection using 2 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed. |
| 14 | S&F prewired VTPN Distribution board with provision for & including MCCB as incommer 100 Amp, 04 pole IP 54, 04way (for incomming MCCB & outgoing MCBs), with copper busbar for each phase, withNeutral bar,Earth bar and cable ties for cable managemet, fully insulated busbar & shrouded Neutral bars, with 100 Amps MCCB, 16 KA, 4 pole, as incomer and SP MCB\"s of capacity 10-32amps as outgoing complete all as specified and as directed. Note: Cost of MCCBs and MCBs, cutting chases, grouting in wall shall be deemed included in unit quoted rate of this item. |
| 15 | SEWAGE DISPOSAL WORKS |
| 16 | Supply and layingDWCPE pipe (SN8) confirming to IS-16098, 150mm nominal bore (160mm OD) laid in trenches over PCC Bed to required slope, including all accessories/fitting/jointing and testing complete all as specified and directed.Note :- PCC shall be paid Seperately under respective prepriced Sch A Part VI (Sewage Disposal Work) . |
| 17 | Supply and layingDWCPE pipe (SN8) confirming to IS-16098, 200mm nominal bore (238mm OD) laid in trenches over PCC Bed to required slope, including all accessories/fitting/jointing and testing complete all as specified and directed.Note :- PCC shall be paid Seperately under respective prepriced Sch A Part VI (Sewage Disposal Work) . |
| 18 | M&L for RCC Septic tank designed for 50 Users to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation , RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including Beams etc with Vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 mtr and overall depth of 3 mtr complete all as specified and directed by Engineer-in-Charge and as per TD drawings of HQ CE PZ. |
| 19 | Soakage wells excavation of Size 2.4 M dia x 3.0M effective depth in any type soil, foundation in PCC 1:3:6 ,walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25 /SFRC cover, interconnecting pipes ofRCC /DWC complete filled with bats of size complete specified and directed by Engineer-in-Charge and as per TD drawings of HQ CE PZ. |
| 20 | SUMMER APPLIANCES WORKS |
| 21 | Supply, installation, testing and commissioning of desert cooler electric driven (single phase) having nominal air flow capacity of 6000 CuM per hour (or nearest size) steel body 18 guages, copper wounded motor 1450 RPM includingsubmersible water lifting pump head not less than 5 feet & water storage tank capacity not less than 60 ltrs, PVC pipe connection, rotary knob, on/off switch, having three side openable shutter with fixing of grass wool, suitable size of floot valve complete all as specified and directed. |
| 22 | EXTERNAL WATER SUPPLY WORKS |
| 23 | M&L Construction of brick masonary valve pit of size 90cm x 90cm x 105cm (internal dimensions) built in cement mortar 1:6, Plain cement concrete.M-10 (nominal Mix) type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and including 15mm thick plastering internally with cement mortar 1:5 and flush pointing externally as the work proceeds in same mortar and plain cement concrete. M-15(nominal mix). type B-1 (using 20mm graded crushed stone aggregates) as in coping 50mm complete including 3.15mm thick MS sheet cover, handle, locking arrangement including provision of angle iron frame 40mmx40mmx6 mm with 15 cm same angle four sides for grouting in PCC for cover and earth work in any type of soil including removal to a distance not exceeding 50 mtr and painting steel surface with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 24 | Cutting of existing pipe of any Size/Dia for inserting Tees for new connection of 25mm dia complete all as specified and directed by Engr-in-charge. |
| 25 | EXTERNAL ELECTRIC SUPPLY WORKS |
| 26 | S&F of bracketfor fixing of street light fittings bend to shape, made out of32 mm dia GI pipe medium grade upto 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primercomplete all as specified and directed by Engr-in-charge. |