| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. SI.No.15.7.4/2023/DSR, (2060.20x.7281=1500.03) |
| 2 | Cartage of Ballast, Kankar, Coal, Grit or Sand etc. including loading & unloading but excluding stackings on pucca roads (SI No. 231a/2022) up to 2 km Distance |
| 3 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.(2.8.1/DSR/2023) (260.30 x .7281=189.52) |
| 4 | 1:5:10 (1 cement: 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources). SI.No.4.1.10/2023/DSR (6518.60 x.7281=4746.19) |
| 5 | Concrete of M25 grade with minimum cement content of 330 kg/cum. SI.No.5.33.1.1/2023/DSR (9504.75 x.7281=6920.40) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 7 | Cement mortar 1:4 (1 cement: 4 coarse sand). SI.No.6.1.1/2023/DSR (7370.65 x .7281=5366.57) |
| 8 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5 mm nominal size derived from natural sources).(SI.No.4.10/2023)/DSR (410.85 x .7281=299.13) |
| 9 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS: 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, including preparation of surface but excluding grading complete with:SI.No.22.8/2023/DSR |
| 10 | Bitumen felt (hessian base) type 3 grade I conforming to:SI.No.22.8.1/2023/DSR (515.05 x .7281=375.07) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: SI.No.5.2.2/2023/DSR (10852.95 x .7281=7902.03) |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 20%).SI.No.5.3A/2023/DSR (11334.70 x .7281=8252.79) |
| 13 | M.S. (tor steel or plain) in Plain work such as R.C.C. or R.B. work including bending for proper shape and including supply of steel & its wastage, bend, hooks, and authorised overlapping shall be measured and including cost of binding wire. (A.R.) |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: |
| 15 | Cement mortar 1:4 (1 cement: 4 coarse sand). SI.No.6.4.1/2023/DSR (9344.25 x .7281=6803.54) |
| 16 | 12MM thick plaster in 1:4 with cement and fine sand of 1.25 fineness modules mortor. (S.I. No.13.1.1/2023)/DSR (347.05 x .7281=272.34) |
| 17 | 12MM thick plaster in 1:4 with cement and fine sand of 1.25 fineness modules mortor rough face. (S.I. No.13.2.1/2023)/DSR (399.45 x .7281=290.83) |
| 18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.(SI.No.9.48.1/2023)/DSR (219.10 x .7281=159.52) |
| 19 | Providing and fixing PVC chicken wire mesh including supply of all materials, labour, Tools & plants etc.required for proper completion of the work. |
| 20 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable Reparately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 21 | All works above plinth and upto floor V level |
| 22 | Concrete of M15 grade with minimum cement content of 240 kg/cum.(SI.No.4.20.2.2/2023) (9341.80 x .7281=6801.76) |
| 23 | S/F of hexagonal/round GP fan box of approved make made up of 1.0 mm thick ISI marked GP sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box . |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.SI.No.13.80/2023/DSR (156.05 x .7281=113.62) |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :SI.No.13.41/2023/DSR |
| 26 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.SI.No.13.41.1/2023/DSR (185.65 x .7281=135.17) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:SI.No.13.62/2023 |
| 28 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture:SI.No.13.62.1/2023/DSR (226.25 x .7281=164.73) |
| 29 | 2.5 cm (1\") thick 1:2:4 plain cement concrete floor with cement, approved coarse sand 2 cm.(1\") graded approved stone grit, laid in panels finished with 3mm. (1/8\") floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and including 8 cm(3\").(SI.No.601/2022) |
| 30 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. SI.No.27.7.1/2023/DSR (1684.60 x .7281=1226.55 |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.....................5.9.2/DSR/2023 (842.50x.7281=613.42) |
| 32 | wiring for light point/fan point/exhaust fan point/call bell point with 1.5 s.q.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit , with modular switch , modular plate ,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required (S.I.NO. 1.3.3/DSR 2022) |
| 33 | S/F of power plug with 15A/250 volt.(M.R.) |
| 34 | Supply and wiring of 2 nos 2.5 sq.mm. FR but in but in 25 mm dia heavy duty (2 mm thick) PVC conduit FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable partly concealed in wall & partly laid in slab along with reinforcement before concreting, with two number 14 SWG copperearth continuity wire including matching colour wash etc, complete in all respect. (SI.No.1.7.2/2022) Elec. DSR |
| 35 | supply and fixing of 6AMP to 32 AMP MCB (10KA) CAT B |
| 36 | S/F surface/Flush mounting & ways SPN distribution board without additional metal door without MCB complete in all respect, as direct by engineer in charge. Cat B (SI.No.302/2018) Elec. SOR |
| 37 | S/F of Amp. S.P. Isolator CAT B |
| 38 | S/F of PVC conduit pipe 25 mm dia 2mm thick in Roof and walls.SI.No.149(A)/2018 SOR Elec. Please Enable Macros to View BoQ information |