| 1 | Taking up or down steel tubing and connections including cleaning for refixing of 15 mm bore complete all as specified and directed. |
| 2 | Supplying and laying of 16mm outerdia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors etc including all necessary fittings etccomplete all as specified.Note:- The cost of Brass threaded Elbow/Tea/Reducer ets shall be included in unit quoted rate no extra shall be paid for fittings/fixtures |
| 3 | Ditto all as per item No 1 above but 20mm bore of pipes. |
| 4 | Supplying and laying of 20mm outerdia of CPVC pipes SDR-11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors etc including all necessary fittings etccomplete all as specified.Note:- The cost of Brass threaded Elbow/Tea/Reducer ets shall be included in unit quoted rate no extra shall be paid for fittings/fixtures |
| 5 | Cutting chases pining in brick wall built in cement mortar for concealed water tubing and making good with CM (1:3), cutting depth not exc 10 cm girth complete all as specified and directed. |
| 6 | M & L for preparation of old decorated surfaces of walls, pillars & cornices including brooming down and cleaning the surfaces & applying onecoatwhitewash up to 4th storey building complete all as specified and directed. |
| 7 | Ditto all as per item No 6here-in-before buton ceiling surfaces. |
| 8 | S&F in repairs LDPE/Fire Retardant (FR Grade ), UV resisitnat, water proof, anti-faded 4mm thick Aluminium Coposite Panle (ACP) of exterior grade special finiesh with aluminium skin thickness not less than 0.25mm to 0.30mm with metalic/PVDF coated finish with denisity 5.50-6.00 Kg /Sqmtr including aluminium framing with cleats and frames (1\"x1.5\"x16 guage) and fixing with SS Rivets/ssScrews and sealing the joints/gaps with waterproof silicon complete all as specified and directed by Engr-in-Charge Note :- The cost of scaffolding shall be included in unit quoted rate by the contractor. The design/Pattern. colour of ACP sheet shall be apporoved by the GE in written prior the the installation. |
| 9 | Providing and Laying 12-15 mm thick heavy duty Parking Tiles ant-skid,Interlocking/Chequered design approved colour & Makefor foothpath/parking/lawn tiles of size 300x300 of choice colour fixing over and 20mm thick screed bed in CM 1:6 complete including taking down old one all as specified and directed |
| 10 | S&F in repairs fibre glass reinforced translucent Plain sheeting 2 mm thick with side lap not less than 10cm fixed with coach screw and washer in roof, wall,iron frame/wooden frame etc at any position and direction , all as specified and directed. |
| 11 | Taking down chowkats or frames not exceeding 1.5 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 12 | ditto as per item No 11 here-in- before but exceeding 1.5 sqm each but not exceeding 4.00 Sqm but with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 13 | S&F Solid PVC door frame of size 50mmx 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube all as per specification and drawing. |
| 14 | S&F Factory made solid panel PVC door shutter 30 mm thick( stile), consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixingin the frame at site as per specification & drawing, all as specified and as directed. |
| 15 | S & F PVC butt hinges medium weight for PVC doors complete all as specified and as directed. |
| 16 | S & F 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed. |
| 17 | S & F 150 mm long Aluminum anodised bow handle fabricated type extruded section complete all as specified and directed. |
| 18 | M & L for complete removal of existing treatment of old internal/external wall/ceiling/chajja surfaces by means of scraping machine including filling the cracks, remove the nails, vegetations etc complete all as specified and directed |
| 19 | M & L for applying two coats of exterior weather proof antialgae 100% acrylic smooth emulsion with silicon additives tthat offers anti algae high peroformance exterior wall finish with five years of peroformance warranty by manufacturere applied by using air less techonology with max working pressure of 3300 PSI and capable of operationg single spray gun with a maximum materialhose length 30 Mtr the spary should beof reputed make as specified bythe manufacturersand as mentioned in PS and accessories for applying the exterior emulsion should be able to spary in hard to reach areas and achive the good wounding and penetration of paints on the surface to achive exelent application using limited manpower including 2.00mm thick wall care putty over a coat of primer complete all as specified and directed (upto 12 th storey). |
| 20 | M & L for applying two or morecoat of exterior weather proof antialgae 100% acrylic smooth emulsion with silicon additives tthat offers anti algae high peroformance exterior wall finish including a coat of primer with five years of peroformance warranty by manufacturere applied by using air less techonology with max working pressure of 3300 PSI and capable of operationg single spray gun with a maximum materialhose length 30 Mtr the spary should beof reputed make as specified bythe manufacturersand as mentioned in PS and accessories for applying the exterior emulsion should be able to spary in hard to reach areas and achive the good wounding and penetration of paints on the surface to achive exelent application using limited manpower complete all as specified and directed (upto 12 th storey). |
| 21 | M&L Complete removal of existing treatment of brick or concrete surfaces putty complete all as specfied and directed |
| 22 | M&L2.00 mm thick (Avg thickness) water proof cement based wall care putty on wall and ceiling and putty applied with blade or steel patti to maintain homogeneous complete all as specified and directed. |
| 23 | M&L for preparing newsurfaceof wall and applying twocoatofacrylicdistemper oil emulsionovercoatof primer forsmoothfinishes of surfaces complete all as specified and directed. |
| 24 | M&L for preparing old plastered or unplasteredsurface of wall and applying onecoatofacrylicdistemper oil emulsion,complete all as specified and directed by the Engr -in-Charge |
| 25 | Taking down/removing of existing water proofing treatment on roof surfaces and wall surfaces complete, including screed bed, mud phuska, PCC, etc racking out joints, hacking for key scrubbing down with water etc, and removing rubbish out of MD land complete all as specified and directed. |
| 26 | M & L for 15 mm thick screed bed(average) plaster on concrete surfaces in CM 1:4on roof, mixed with water proofing compound(@200 ml per bag of cement) and finishing the surface even and smooth without using extra cement complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid separately under relevant item of Sch \"A; given here-in-after) |
| 27 | M & L for spreading / brushing neat cement slurry with 3.00 Kg/ Sqm on old concrete surface complete all as specified and directed. |
| 28 | M & L PCC (1:2;4) type B-0 using 12.5 mm graded stone aggregate thickness as required at site) for padding concrete as on roof, mixed with water proofing compound (@200 ml per bag of cement) complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately. |
| 29 | M & L for water proofing treatment on horizontal or vertical surfaces with provision of oil bound bitumen primer @ 0.50 Kg/ Sqm and providing 3 mm thick, APP modified water proofing membrane weighing not less than 3.50 Kg/Sqm reinforced with non-oven polyester fabric weighing not less than 160 gm /Sqm all as per detailed specifications, sealed with overlaps shall be with torch application and applying two coats of aluminium reflective paints complete all as specified and directed. |
| 30 | S & F in repairs18 mm thick 100% Lead free both side plain laminated PVC/WPC sheet of any colour with using sunmica of choice colour on both sidefor kitchen cabinet shutters, shelves and shutters for cup board or similar use and required bracket etc. The panels shall be fabricated using adhesive and screws where ever required. All edges shall be covered with 2 mm thick edge bending tape or 90 degree edge bent finish as per manufacterer’s instruction and make approved by GEcomplete all as specified and directed. Note : All fittings and fixtures such as Soft closer, handles, piano hinges etc for shutter should be included rated quoated by the contractor. |
| 31 | M & L for preparing old decorated plastered or un-plastered surfaces of wall, pillasters, cornices etc bybroomingdownor steel wire brushing, scrapping down smoke,roots,moulds ,moss andefforehance,saltand trading oil and greasy spot and applying two coatscement base paint complete all as specified and directed. (upto 4tth storey) |
| 32 | M & L forpreparationof old painted wooden /wood based surface of any descriptionexceeding10 cm width or girth bywashingdownwith solutionof alkaline soapto remove all loose dirtand oily& greasespotsand applyingone coatof syntheticenamelpaintcomplete all as specified and directed . |
| 33 | Ditto all as per item No.32 here-in-beforebut on steel surfaces |
| 34 | Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water etc complete all as specifiedand directed. |
| 35 | M & L for rendering 15 mm thick in CM ( 1:6 )on wall/ concrete surfaces finish even and smooth without using extra cement including two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 36 | M & L for rendering 10 mm thick in CM ( 1:6 )on wall/ concrete surfaces finish even and smooth without using extra cement including two coats of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 37 | M & L for 10 mm thick plasterinCM (1:3) on ceiling surfaces finished even and smooth without using extra cement and applying three coats of white wash after preparation of surfaces complete all as specified and directed . |
| 38 | M& L re-writingletters or figures (Block roman italic or Indian ) by using synthetic enamel paintnot exceeding30 cm height completeall as specified and directed. |
| 39 | M & L for repairing of damaged portion of mouth at tarrace / roof surface of rain water pipe by cleaning and repairingto mouth of RWP by usingCM (1:3) with mix with liquid WPC @ 3% weight of cement & sealedwith 85/25 hot blown grade bitumencomplete to make joint of rain water pipe and roof suface fully leak proofcomplete all as specified and directed. |
| 40 | M & L forrepair to chajja area not exceeding 1 sqm each including plaster in CM(1:3) or PCC type B0 (1:2:4) (using 12.5 mm stone aggregate) on top with WPC@ 3% weight of cement,benching/haunching, repair to broken plaster with dubbing coat complete all as specified and directed. |
| 41 | M & L for repair to chajja area exceeding2 Sqm and not exceeding4 sqm each including dismentling of upward facia,cutting of reinforcement , plaster in CM(1:3) or PCC (1:2:4)type B 0 (using 12.5 mm stone aggregate) on top with WPC@ 3% weight of cement , benching/haunching,repair to broken plaster with dubbing coatupto 11th floor of building. The cost of scofolding inclusive in the unit quoted rate by the bidders. |
| 42 | M& Lfor repair to chajja area exceeding 1 Sqm and not exceeding 2 sqm each including dismentling of upward facia,cutting of reinforcement , plaster in CM (1:3) or PCC(1:2:4)type B0using 12.5 mm stone aggregate on top with WPC@ 3% weight of cement ,benching/ haunching,repair to broken plaster with dubbing coatupto 11th floor of building. The cost of scofolding inclusive in the unit quoted rate by the bidders. |
| 43 | Suppply only Liquid water proofing compound complete all as per manufacturer\"s instruction complete all as specified and directed. |