| 1 | BOQ Dated 30 Jan 2026 |
| 2 | GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XII are prepriced by MES under Ser No. 1 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 3 | Lumpsum price worked out by the contractor for “Building or Works” as listed in Schedule ‘A’Part–I |
| 4 | Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II |
| 5 | Lumpsum price worked out by the contractor for “Internal Electric Supply\" as listed in Schedule ‘A’Part–III |
| 6 | Lumpsum price worked out by the contractor for “Road / Path\" as listed in Schedule ‘A’ Part - IV . |
| 7 | Lumpsum price worked out by the contractor for \"Area Drainage\" as listed in Schedule ‘A’ Part - V . |
| 8 | Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI. |
| 9 | Lumpsum price worked out by the contractor for “External Water Supply/Hot Water Supply” as listed in Schedule ‘A’ Part – VII |
| 10 | Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part –VIII |
| 11 | Lumpsum price worked out by the contractor for “Lift” as listed in Schedule ‘A’ Part – IX |
| 12 | Lumpsum price worked out by the contractor for \"Lightning Protection” as listed in Schedule ‘A’ Part – X |
| 13 | Lumpsum price worked out by the contractor for \"AC Wiring” as listed in Schedule ‘A’ Part – XI |
| 14 | Lumpsum price worked out by the contractor for \"Fire Fighting” as listed in Schedule ‘A’ Part – XII |
| 15 | Sch \"A\" Part - XIII : BUILDINGS OR WORKSDesign and Construction of (G+2 ) Md Accn for 5 JWO and above Building with car /scooter parking construction with permanent specifications in RCC M- 30 grade (Design Mix) framed structure, AAC block masonry walls, ATT, PU based WPT,including RCC over head tank for domestic and fire fighting of 10000 litre capacity, earthquake resistance as per latest IS and Green building norms with GRIHA 3 star ratingsetc complete all as specified and as shown on drawings. |
| 16 | Design and Construction of Multi storey(S+5 )Md Accn for 20 Sgt and below Building with car / scooter parking construction with permanent specifications in RCC M-30(Design Mix) grade framed structure, AAC block masonry walls, ATT, PU based WPT, including RCC over head tank for domestic and fire fighting,earthquake resistance as per latest IS and Green building norms with GRIHA 3 star ratingsetc complete all as specified and as shown on drawings. |
| 17 | Design and Construction of Pump house Building construction with permanent specifications in RCC M-30(Design Mix) grade framed structure, PCC block masonry walls, ATT, PU based WPT, earthquake resistance as per latest IS and Green building norms with GRIHA 3 star ratingsetc complete all as specified and as shown on drawings. |
| 18 | SCHEDULE \"A\" Part- XIV (FITTINGS AND FIXTURES & MISC ITEMS) |
| 19 | INTERNAL WATER SUPPLYSupply and fix 15mm bore kitchen sink tap, brass chrome finish dual flow pattern with silicon black flexible hose swivel pipe complete all as specified and as directed. |
| 20 | Supply and fix 15mm bore washing machine tap, brass chrome for galvanised iron pipe complete all as specified and as directed. |
| 21 | INTERNAL ELECTRIC SUPPLY Supply and fix exhaust fan, AC, single phase, 240 V, 250 mm sweep,PVC body with louvers, including connected with 3 core 1.5 sq mm copper conductor cable from ceiling rose to exhaust fan all as specified and as directed. |
| 22 | Supply and fixMCB 3 pole, 415 volts, 125Ampere, rupturing capacity 16 KA, in the DB complete all as specified and as directed. |
| 23 | Supply and fix MCB 3pole, 415 volts, 100Ampere, rupturing capacity 16 KA, in the DB complete all as specified and as directed. |
| 24 | Earthing complete with galvanized iron earth plate electrode of size 600mmx600mm x 6.3 mm thick buried directly under ground vertically to depth not less than 2.25 meter below ground levelwith top edge of plate at a depth not less than 1.5 m below ground level connected to and including GIwire 4mm dia andGI protection pipe 15mm dia and light grade connectedto and including by means of bolts nuts check nutsand washers made of copper as shown plate no 3 of SSR part 1 to the extent applicable to this item including necessary excavation earth work , PCC 1;3;6 chamber RCC 1;2;4 cover 50mm tick with 6mm TMT bar 100mm center to center watering pipe medium grade 20mm boe funnel wire mesh etc. and testing on completion all as specified and as directed. |
| 25 | Supply and fix modular telephone socket RJ-11 one module all as specified and directed. |
| 26 | M&L for Mild steel box of telephone wiring including blocks, suitable for 30 pair all as specified and directed. |
| 27 | M&L for Telephone wiring with unarmoured solid annealed bare copper industrial cable in concealed of size 0.5 mm, 3 pair with PVC conduit 25 mm dia all as specified and directed. |
| 28 | Supply and fix modular TV socket one module all as specified and directed. |
| 29 | M&L for TV wiring with unarmoured coaxial cable RG-11 in concealed with PVC conduit 25 mm dia all as specified and directed. |
| 30 | Supply, installation, testing and commissioning ofsmartmeters with pre-paid metering facility,AC singleintergradation phase, two wire, 240 volts, 50Hz, 10 to 60 Amps all as per BIS16444:2015 (Reaffirmed 2020) with plug-in type bi-directional communicationModule ( The plug-In Module shall be field swappable/replaceable) suitable forintegration with approved communication technology GPRS / RF /Hybrid(GPRS+RF) /any other advanced technology as per CEA / TRAIregulations etc. easily adaptablefor network interface and integration withAdvanced MeteringInfrastructure(AMI)complete in all respect all as specified and as directed by Engineer-in-charge. |
| 31 | SEWAGE DISPOSALMaterial and labour for 150 user LLDPE Septic Tank Designed to carry sewage and sullage water, Excavation in any type of Soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete all as specified and as directed. |
| 32 | EXTERNAL WATER SUPPLYSupply, install, testing & commissioning of Monoblock pump set having capacity 15 HP, discharge 17.5 LPS, head 34 meter, 415 V, 3 phase, 50 Hz, with cast iron impeller and gland packingincluding base frame, foundation, fixing accessories complete all as specified and as directed. |
| 33 | Supply, install, testing & commissioning of high pressure single head chemical dosing system, power input 230V, 50 Hz, 1/30 fractional HP, pressure 5kg/Sqcm, Max output 6.5 ltr/hr with accessories like lead tubing, connecting ferrule, check valves etc included as following: (i) Preparation tank of capacity 170 Ltrs FRP tank consisting of water inlet line, outlet with Y strainer, Drain overflow, conical bottom of sludge deposition, pot hole with cover, level guage. (ii) Agitator 120 watt 900 RPM single phase flange mounted mtr with plastic shaft and impeller. (iii) Service tank of capacity 100 ltrs of FRP dosing tank consisting of water inlet line, dosing pump inlet arrangement, drain over flow, level guage, Inspection port. |
| 34 | Supply and laying DI pipe spigot and socket type class \" K-9\", 100 mm (4\") dia suitable for tyton ring joint complete all as specified and as directed. |
| 35 | Construction of Masonry valve chamber 1500mm x 1500mm x 750mmincluding excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6), plastering internal surface 15 mm tick in CM (1:4), PCC (1:3:6) type C1 coping 50mm x50mmx6 mm angle iron, 6 mm thick MS plate cover complete with locking arrangement, painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed. |
| 36 | Supply, installation, commissioning and testing of LT Feeder Pillar Box indoordoor, double door type made out of CRCA Sheet of 2.00 mm thick with powder coated painting frame suitable size for fixing the I/C & O/G MCCB mentioned below made out of angle iron 45 x 45 x 6 mm and four numbers of 300 Amps aluminum strips / bars duly insulated on insulators - 4 Nos / suitable size Bakelite sheet, free space between MCCBs / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size and comprising and including the following (for PH) |
| 37 | (A) Main Incoming(i) MCCB TPN (4 pole), 160 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA - 01 No.(ii) LED Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs \"(iii) Onload changeover 4 pole 100 Amp capacity- 01 No(iv)LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set(B) Main Outgoing(i) MCCB TPN (4 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 01 No.(ii) Star Delta Starter 15.0 HP- 02 Nos(iii) MCB TPN 6-32 Amps, 10 kA, C Curve - 01 Nos ( Spare) |
| 38 | EXTERNAL ELECTRIC SUPPLYSupply, installation, testing & commissioning of HT 11 KV 3 Phase, rated voltage 12 Kv, 630A, 21kA/3sec, 50 Hz Outdoor type, extensible type, floor mounted with copper bus bars, SF6 gas Insulated, completely Manual operated, 1 Way consisting of 1 No Switch fuse unit and earth fault protection Relay with 250MVA rupturing capacity totally enclosed metal clad switchgear. The unit shall have front cable entry (Suitable for termination of 1R x 3C x 95 Sqmm Cable). The unit shouldbe complete with all accessories such as Terminal boots, mechanical indications for Load break switch ON/OFF, Manometer etc including foundation as per OEM all as specified. Note: Contractor shall submit the detailed OEM drawing for approval of Engr-in-Charge. |
| 39 | Supply, installation, testing & commissioning of HT 11 KV 3 Phase, rated voltage 12 Kv, 630A, 21kA/3sec, 50 Hz Outdoor type, extensible type, floor mounted with internal copper bus bars, SF6 gas Insulated, completely Manual operated, 2 Way RMU consisting of 1 NoLoad Break Switch as Incomer & 1 No 630A VCB as Outgoing for Transformer withOverload and earth fault protection Relay with 250 MVA rupturing capacity. The unit shall have front cable entry (Suitable for termination of 1R x 3C x 95 Sqmm Cable ). RMU shouldbe complete with all accessories such as Terminal boots, mechanical indications for Load break switch ON/OFF, Manometer etc including foundation as per OEM all as specified.Note: Contractor shall submit the detailed OEM drawing for approval of Engr-in-Charge. |
| 40 | Supply, installation, testing and commissioning of Silent DG set 82.5 KVA, 3 phase 4 wire , 415 volts , 1500 RPM, 50 Hz power supply with power factor 0.8, coupled directly to alternator mounted on a common base frame plate complete with integral acoustic enclosure having silent features to withstand all weather conditions and for outdoor application with AMF Panel. The design of the DG set shall confirm the CPCB IV+ norm/ regulation with fuel tank, battery and standard accessories, PCC foundation siutable to mount DG set as per size recommended by OEM and the height of the plinth shall be 45cm above the ground level all as specified and directed with the following specifications. Note: Contractor shall submit the detailed OEM drawing for approval of Engr-in-Charge. |
| 41 | (a) ENGINE: Diesel engine of suitable capacity to match the 82.5 KVA alternator under NTP conditions with provision of 10% overload for 1 hour in every 12 hours running. The engine shall consist of following: (i) Fly wheel (ii) Radiator, Air to Air after cooler, pusher fan & fan drive arrangement. (iii) Dry type air cleaner with restriction indicator (iv) Fuel injection system (v) Radiator fan (blower type) with guard (vi) Gear driven water pump (vii) Fuel filter (viii) 12 V DC electrical starting system (ix) Exhaust silencer heavy duty residential type (x) First fill of lubricating oil (xi) Sensors for oil pressure, coolant temperature & level.(b) Control panel: The control panel with microprocessor based DG Set controller for engine and alternator parameter in one console including complete internal wiring and shall confirm dust proof & vemin proof. The control panel consists of the following parts: (a) Auto start control module with Auto Mains Failure control module as per latest version. (b) MCCB of adequate rating. (c) Indicating lamps for DG ON, Mains ON, Load on DG, Load on Mains etc.(d) Key switch (e) Set of current transformers and MCBs (f) Controller shall monitor and display the engine speed, oil pressure, coolant temperature, frequency, voltage, current, power factor and fuel level, battery voltage and modules for comprehensive engine and alternator protection, display the array of warning, electrical trip and shutdown alarm. The controller shall provide a record of most recent fault conditions. Fault history stored in the control non volatile memory. (g) Emergency stop : Annuciated whenever an emergency stop signal is received.(c) Alternator: Alternator self excited, self regulated brushless single bearing alternator 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz coupled to engine with consisting of following parameters. (i) Type : Self excited self regulated with automatic voltage regulator (ii) Rating 82.5 KVA at 0.8 PF lagging. (iii) Speed : 1500 RPM (iv) Connection: Star conenction (v) Ventilation: Self Ventilated. (vi) Insulation: Class \"H\"(d) AMF Panel : The AMF Panel outdoor type suitable for 82.5 KVA DG set factory fabricated, floor mounted, front operated, totally enclosed dust and vermin proof with suitable Incomer and Outgoing MCCBs 4 pole type, CTs, Indicating lamps LED(RYB) for Incoming/Outgoing, Illuminating push buttons with elements LED type with NO/NC, Digital MFM3 phase 415 V AC - 01 Each, battery charger of suitable capacity, AMF controller 12V DC - 01 Each, Aux relay/coil voltage of suitable capacity complete. |
| 42 | Note:- The cost of PCC platform as recommended by the OEM and the expenses for cost of testing of DG Sets shall deemed to be inclusive of quoted rate. Make: KirloskarGreen/ Jackson / Powerica / Greaves Cotton or any other make specified in particular specifications |
| 43 | Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting frame suitable size for fixing the I/C & O/G MCCB mentioned below made out of angle iron 45 x 45 x 6 mm and four numbers of 600 Amps aluminum strips / bars duly insulated on insulators - 4 Nos / suitable size Bakelite sheet, free space between MCCBs / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel as required, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size and comprising and including the following (for Transformer): |
| 44 | (A) Main Incoming(i) MCCB TPN (4 pole), 400 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA - 01 No.(ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii)LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set(iv) 5 Step APFC Relay with ultra hevay duty capacitor of rating 20 kVAR-01 No., 05 kVAR-03 Nos along with necesaary harmonic filters, Duty Contactors, control switch gears etc - 1 Set(B) Main Outgoing(i) MCCB TP (3 pole), 200 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 01 No. (ORs )(ii) MCCB TP (3 pole), 160 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 02 No. ( PH & Spare -1)(iii) MCCB TP (4 pole), 125 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 02 No. (Jcos , & Spare -1)(iv) MCB TPN 6-32 Amps, 10 kA, C Curve - 03 Nos(street light)(v)Street light timer with contacts 3 Ph - 01 Nos (Digital) |
| 45 | Supply, installation, commissioning and testing of LT Feeder Pillar Box indoordoor, double door type made out of CRCA Sheet of 2.00 mm thick with powder coated painting framesuitable size for fixing the I/C & O/G MCCB mentioned below made out of angle iron 45 x 45 x 6 mm and four numbers of 300 Amps aluminum strips / bars duly insulated on insulators - 4 Nos / suitable size Bakelite sheet, free space between MCCBs / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size and comprising and including the following (for NCOS) |
| 46 | (A) Main Incoming(i) MCCB TPN (4 pole), 160 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA - 01 No.(ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii)LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set(B) Main Outgoing(i) MCCB TPN (4 pole), 100 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 01 No. (GF )(ii) MCCB TPN (4 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 05 No. (first to fifth)(iii) MCB TPN 6-32 Amps, 10 kA, C Curve - 01 Nos ( Spare) |
| 47 | Supply, installation, commissioning and testing of LT Feeder Pillar Box indoordoor, double door type made out of CRCA Sheet of 2.00 mm thick with powder coated painting framesuitable size for fixing the I/C & O/G MCCB mentioned below made out of angle iron 45 x 45 x 6 mm and four numbers of 300 Amps aluminum strips / bars duly insulated on insulators - 4 Nos / suitable size Bakelite sheet, free space between MCCBs / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size and comprising and including the following (for JCOS) |
| 48 | (A) Main Incoming(i) MCCB TPN (4 pole), 160 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA - 01 No.(ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii)LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set(B) Main Outgoing(i) MCCB TPN (4 pole), 100 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 01 No. (GF )(ii) MCCB TPN (4 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA - 03 No. (first to Third)(iii) MCB TPN 6-32 Amps, 10 kA, C Curve - 01 Nos ( Spare) |
| 49 | Supply and fix smart intergrated all in one solar street light of 24 Watt, 5700 K with High efficiency Mono crystalline solar PV Module, Lithium Ferro Phosphate battery with in build BMS technology, High Efficacy LED, MPPT solar charge controller and Aluminium Extruded body & is specially programmed to automatically contrtol the dimming and brightness of light, which increases the backup time including street light brackets made of 25 mm dia G.I. Pipe light grade in shape and including suitable size of reducer to fix the LED street light of capacity 24W and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. flat iron clamps, 2 Nos, M.S nut & bolt with cup washers complete all as specified and as directed. |
| 50 | Material and labour for Octagonal pole of 5 mtr height of bottom size 130 mm and top 70 mm dia with base plate size 220 x 220x12 mm, foundation bolts, Hot dip galvanized, single Arm suitable for fixing of All in one Solar Street light fitting of 24 Watt including necessary clamps, nuts, bolts and earth work, foundation suitable for wind pressure of 100 Km/Hour complete all as specified and as directed. |
| 51 | Supply and fix loop in-out junction box with non mettalic FRP junction box suitable of size (Appx 350 x 250 x 150) with connector 4 way and including one MCB SP 6 A, 230V alongwith 2 Nos \"C\" Clamps and back clamp made up of 20x3 flat iron and fixing on pole with necessary nuts bolts, washers, 2 Nos PVC cable glands of size not exc 4 core 25 sqmm, Cable lugs as required complete all as specified and as directed. |
| 52 | Material and labour for Dry Sand filling in cable trenches for protection of cables with two layers below and above cable and punned down to specified thickness complete all as specified and as directed. Note: Punned down thickness shall only be measured for payment. |
| 53 | FIRE FIGHTING EQUIPMENTS:-Supply and fix Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 : 1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 36m head, 450 LPM discharge including provision of PCC foundation, Pressure switch and pressure gauge etc including suitable weather proof MS enclosure as specified and as directed. |
| 54 | Supply and fix wall mounted motor control panel with following accessories for Booster pump complete all as specified and as directed.(i) MCCB 4 pole,440V, 50HZ and 36KA(ii) Automatic star delta starter(iii) Digital type volt meter and ammeter(iv) On/Off indication lamps |
| 55 | Schedule \"A\" Part - XV (Outsourcing services for operation of lifts)Out sourcing man power for maint and operation of (01 x 13 passenger lift and 01 x 08 passenger lift) including taking care of installed machineries, speed 1.5m/s in three shifts of calender month by deploying one lift operator for both lifts (semi skilled) in three shifts at NCOs bldg deploying for their operation including material for maintenance like cotton waste, grease, petroleum jelly, CRC, distilled water etc complete all as specified and as directed by Engineer in charge. (a) Location NCOs Bldg(b) each shift shall be 08 hours timing to 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs including sundays and holidays complete all as specified and directed. First year after completion of Phase-IIINotes:-(i) Lift operator shall have ITI certificate in the trade fitter/ mechanic / Electrician / 10+2 with minimum 3 years experience in relevant trade(ii) Necessary daily log sheet in respect of the lift shall be maintained by the operator on printed log sheet shall be provided by the contractor as approved by Engineer in charge. The cost of stationary and printed log sheet is deemed to be included in the quoted rate.(iii) To ensure working on all the days of week, relief for individuals to be provided to ensure adequate periodical breaks as required under labour laws for which cost is deemed to be included in the quoted rate.(iv) The contractor is advised to ensure all safety measures to prevent any mishaps to the labour employed in the lifts.(v) A penalty of Rs 2000/per day will be imposed on the contractor if the lift operator is found absent from duty on any day. |
| 56 | All as per serial item No.46 but for second year after completion of main project (Phase-III) |
| 57 | Schedule \"A\" Part - XVI (Comprehensive maintenance of lifts and outsourcing of services for operation of Lifts)All as per serial item No.46 but for Third year after completion of main project (Phase-III) |
| 58 | All as per serial item No.46 but for Fourth year after completion of main project (Phase-III) |
| 59 | All as per serial item No.46 but for Fifth year after completion of main project (Phase-III) |
| 60 | Comprehensive AMC for the lift through OEM during first year after completion of Phase-IV i.e first year post defects liability period(01 x 08 passenger lift and 01 x 13 passenger lift) this includes regular inspection servicing and maint of the lift components, lubrication of all moving parts and cleaning of lift shaft and pits.Schedule preventive maintenance of as per OEMs recommendations replacement of worn out parts including batteries and other moving parts prevent breakdowns.Testing and calibration of safety devices to ensure function correctly 24x7 emergency call out services to attend lift breakdowns are malfunctions |
| 61 | Notes: (i) Incase of lift breakdown or malfunctions the contractor must response within two hours of receiving the notifications failure to respond within the specific time will resulting a penalty of Rs 1000/hour of delay.(ii)Routine maintenance visit must carried out and any missed routine maintenance visit will incur a penalty of Rs 500/- for missed visit.(iii) Detail logs of all maintenance activities must be maintain and made available to the JE/Eng-In-Charge.Log must include date and time of maint activities performed and parts replaced.(iv) Detail of reports of any breakdowns, malfunctions or safety incidents in the logs as well as submit the same to JE/Eng-In-Charge within the two hours of occurrence.The report must include date and time of maint activities performed and parts replaced.(v)The comprehensive AMC contractor starts after the post defective period i.e., after the two years post defects liability period.(vi)The comprehensive AMC contractor is for both passenger lifts and quoted rates included for both the lifts.Payment may be taken monthly depending upon the fund availability penalty if any will be deducted from RAR/Final bills. (vii) After completion of the comprehensive AMC period the lift will be inspected by the nominated officer/IEM before taking over the department.The contractor will be liable for replacement of any damages/worn-out parts noticed during inspections.the lift will be handed over the full working conditions including ARD with the satisfaction of inspecting officer.(viii)The MoU for the post defect liability period between contractor and OEM shall be at least 06 months prior to issue of completion certificate of the main contract. (ix) The testing and commissioning of lift to be carried out by IEM before entry into service. |
| 62 | All as per serial item 51 for but Second year after completion of Phase-IV i.e After the expiry of Defects Liability Period. |
| 63 | All as per serial item 51 for but Third year after completion of Phase-IV i.e After the expiry of Defects Liability Period. |