| 1 | Surface Excavation n. exc. 30cm deep& avg 15 cmdeep & getting out in hard dense soil. |
| 2 | Roughearth workexcavationinordinarysoiluptoadepth1.5mtr.Fromthestartingpoint |
| 3 | Excavating intrenches n .exc 1.50 m depth and getting out in hard dense soil |
| 4 | Excavating intrenches n .exc 1.50 m to 3.0 m depth and getting out in hard dense soil |
| 5 | Plain Cement concrete 1:4:8 type C1 using 40mm graded aggregate in surface channels and drains |
| 6 | R.c.c. footing withcementmortar 1:2:4,using 20mmgradedstoneaggregate as infoundation |
| 7 | R.C.C 1:2:4 using 20mm graded aggregate columns |
| 8 | R.C.C 1:2:4 using 20mm graded aggregate beams |
| 9 | Reinforced Cement concrete in roof slab |
| 10 | Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hopping ends and binding with and including MS wire not less than 0.9mm dia. |
| 11 | Formworksidesof concrete surfacesinfoundationfootings |
| 12 | Formworksidesof concrete surfacesinColumns |
| 13 | Formworksidesof concrete surfacesinBeams |
| 14 | Formworkto soffits of suspended slab such as roof slab not exceeding 250mm thick |
| 15 | Returning and filling including spreading levelling watering and well ramming in layer n exc 25cm |
| 16 | Removing excavated soil to a distance of 50 mtrs |
| 17 | Rendering in cement mortar 1:6, 15mm thick on fair faces of walls |
| 18 | Ceiling plastering with cm 1:3, 15mm thick of roof slab |
| 19 | Plain cement concrete 1:2:4 type C1 using 20mm graded stone aggregate as in bed block |
| 20 | Screed bed or bedding layer of 1:4 motor 15mm thick for laying floor finishes |
| 21 | Steel doors complete including protection type hings etc., with glazing bars |
| 22 | White washing on wall surface three coats including preparation of surface |
| 23 | White washing on Ceiling surface three coats including preparation of surface |
| 24 | Preparing newly plastered wall surface and applying two coats of cement based paint over a coat of primer |
| 25 | Preparing steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer |
| 26 | M& L for complete with GI earth plate electrode 600 x600x6 mm thick buried directly in ground earth plate not less than 2.25 m deep below ground level with top edge of the earth plate not less than 1.5 meter below normal groundlevel connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts, washers and GI earth wire protected by 15 mm dia GI pipe for watering funnel, Earth work PCC chamber with 40 mm thick RCC 1:2:4 type \"B\" for cover slab with 6 mm dia MS bar and 100 mm both ways with MS Hook 8 mm dia all as shown in electrical plate No. 5 all as specified and as directed. |
| 27 | M & L for sub main wiring with 2 runs of single core stranded copper copper conductor 6 sqmm PVC inculated and unsheathed drawn through and including suitable size non metalic regid PVC conduit with all acessories fixed to walls, ceiling including 1 run of 4.00sqmm copper ( Insulated) cableas earth contiunity xonductor including taking down existing unserviceable sub main wiring all as specified and as directed. Note: Two runs of conductor and one run of earth wire and one run of PVC conduitshall be measured as one unit. |
| 28 | Supply and fixing double door MCB distribution board in sheet metalenclosureSPN 8 way with 200 Amps, 240 Volt rated bus bar neutral andearth connected bars for use of MCB’s fixed properly at directed place by using suitable required fixing arrangement |
| 29 | Supply and fixing double door MCB distribution board in sheet metalenclosure TPN 4 way with 200 Amps, 415 Volt rated bus bar neutral andearth connected bars for use of MCB’s fixed properly at directed place by using suitable required fixing arrangement |
| 30 | Supply and fixingRCB SPN 16Amps, 30mA breakingcapacity, 240Volt ACall as specified and as directed. |
| 31 | Supply and fixingRCCB TPN 40Amps, 30mA breakingcapacity, 415Volt ACall as specified and as directed. |
| 32 | Supply and fixingMCB SP 6/ 32Amps, 10KA rupturing capacity, 240Volt ACall as specified and as directed. |
| 33 | Supply & Connecting Tamper proof Electronic Energy Meters three phase 240 V, AC , 50 HZ, ISI marked Class I, LCD type30 to 60 Amps capcity,including making seal of MES afater removing the old unserviceable meters all as specified and as directed. (Make : L & T or Equivalent) |
| 34 | M & L for sub main wiring with 2 runs of single core stranded copper copper conductor 6 sqmm PVC inculated and unsheathed drawn through and including suitable size non metalic regid PVC conduit with all acessories fixed to walls, ceiling including 1 run of 4.00sqmm copper ( Insulated) cableas earth contiunity xonductor including taking down existing unserviceable sub main wiring all as specified and as directed. Note: Two runs of conductor and one run of earth wire and one run of PVC conduitshall be measured as one unit. |
| 35 | Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 36 | Supply and fixing LED light fitting 1x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 37 | Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |